Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 310(1): e230614, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38289213

RESUMO

Background Patients have the highest risk of subsequent fractures in the first few years after an initial fracture, yet models to predict short-term subsequent risk have not been developed. Purpose To develop and validate a deep learning prediction model for subsequent fracture risk using digitally reconstructed radiographs from hip CT in patients with recent hip fractures. Materials and Methods This retrospective study included adult patients who underwent three-dimensional hip CT due to a fracture from January 2004 to December 2020. Two-dimensional frontal, lateral, and axial digitally reconstructed radiographs were generated and assembled to construct an ensemble model. DenseNet modules were used to calculate risk probability based on extracted image features and fracture-free probability plots were output. Model performance was assessed using the C index and area under the receiver operating characteristic curve (AUC) and compared with other models using the paired t test. Results The training and validation set included 1012 patients (mean age, 74.5 years ± 13.3 [SD]; 706 female, 113 subsequent fracture) and the test set included 468 patients (mean age, 75.9 years ± 14.0; 335 female, 22 subsequent fractures). In the test set, the ensemble model had a higher C index (0.73) for predicting subsequent fractures than that of other image-based models (C index range, 0.59-0.70 for five of six models; P value range, < .001 to < .05). The ensemble model achieved AUCs of 0.74, 0.74, and 0.73 at the 2-, 3-, and 5-year follow-ups, respectively; higher than that of most other image-based models at 2 years (AUC range, 0.57-0.71 for five of six models; P value range, < .001 to < .05) and 3 years (AUC range, 0.55-0.72 for four of six models; P value range, < .001 to < .05). Moreover, the AUCs achieved by the ensemble model were higher than that of a clinical model that included known risk factors (2-, 3-, and 5-year AUCs of 0.58, 0.64, and 0.70, respectively; P < .001 for all). Conclusion In patients with recent hip fractures, the ensemble deep learning model using digital reconstructed radiographs from hip CT showed good performance for predicting subsequent fractures in the short term. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Li and Jaremko in this issue.


Assuntos
Aprendizado Profundo , Fraturas do Quadril , Adulto , Humanos , Feminino , Idoso , Estudos Retrospectivos , Fraturas do Quadril/diagnóstico por imagem , Área Sob a Curva , Tomografia Computadorizada por Raios X
2.
Medicina (Kaunas) ; 60(5)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38792863

RESUMO

Introduction: Basicervical femoral neck fracture (FNF) is an uncommon type of femoral neck fracture and is associated with an increased risk of fixation failure due to its inherent instability. The purpose of this study was to compare the surgical parameters and reoperation rate between the use of a multiple cannulated screw (MCS) and fixed angle device (FAD) in treating basicervical FNFs. Methods: We retrospectively reviewed the records of 885 patients who underwent internal fixation between May 2004 and August 2019 to determine basicervical FNF with at least 12 months of follow-up. Among the identified 77 patients with basicervical FNF, 17 patients who underwent multiple cannulated screw (MCS) fixation and 36 patients who underwent fixed angle device (FAD) fixation were included. We compared the rates of fracture-site collapse and reoperations according to the fixation device. Results: Among the 53 patients with basicervical FNF, 13 patients (24.5%) sustained surgical complications (8 collapses of fracture site and 5 reoperations). The reoperation rate in the MCS group was significantly higher than that in the FAD group (23.5% vs. 2.8%, p = 0.016), without any significant difference in the collapse of the fracture site (11.8% vs. 16.7%, p = 0.642). Conclusions: Although basicervical FNF was rare among hip fractures, fracture site collapse was prevalent and prone to fixation failure. Surgeons should keep this in mind, and consider FAD for basicervical FNF.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Fixação Interna de Fraturas , Humanos , Fraturas do Colo Femoral/cirurgia , Feminino , Masculino , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/estatística & dados numéricos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Reoperação/estatística & dados numéricos , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia
3.
Gastric Cancer ; 26(5): 814-822, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37209225

RESUMO

PURPOSES: Previous studies have suggested that there is an increased risk of osteoporotic fracture in gastric cancer survivors. However, the data was not classified according to surgery type. This study investigated the cumulative incidence osteoporotic fracture (OF) in gastric cancer survivors according to treatment modality. METHODS: A total of 85,124 gastric cancer survivors during 2008-2016 were included. The type of surgery was classified as total gastrectomy (TG, n = 14,428)/subtotal gastrectomy (SG, n = 52,572)/endoscopic mucosal dissection and endoscopic mucosal resection (ESD/EMR, n = 18,125). The site of osteoporotic fractures included the spine, hip, wrist, and humerus. We examined cumulative incidence using Kaplan-Meier survivor analysis and cox proportional hazards regression analysis to determine the risk factor of OF. RESULTS: The incidence of OF per 100,000 patient year was 2.6, 2.1, 1.8 in TG, SG, ESD/EMR group. The cumulative incidence rate was 2.3% at 3 years, 4.0% at 5 years, and 5.8% at 7 years in gastrectomy group, and 1.8% at 3 years, 3.3% at 5 years in the SG group, and 4.9% at 7 years postoperatively in ESD/EMR group. TG increased the risk of OF compared to patients who underwent SG (HR 1.75, 95% confidence interval [CI] 1.57-1.94), and ESD/EMR (hazard ratio [HR] 2.23, 95% CI 2.14-2.32). CONCLUSION: Gastric cancer survivors who underwent TG had an increased osteoporotic fracture risk than did SG or ESD/EMR in these patients. The amount of gastric resection and accompanying metabolic changes seemed to mediate such risk. Additional research is needed to establish an optimal strategy for each type of surgery.


Assuntos
Sobreviventes de Câncer , Ressecção Endoscópica de Mucosa , Fraturas por Osteoporose , Neoplasias Gástricas , Humanos , Fraturas por Osteoporose/epidemiologia , Fraturas por Osteoporose/etiologia , Fraturas por Osteoporose/cirurgia , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/etiologia , Gastrectomia/efeitos adversos , Endoscopia , Mucosa Gástrica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
4.
BMC Musculoskelet Disord ; 24(1): 878, 2023 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-37951880

RESUMO

BACKGROUNDS: The humeral head is the second most common site of osteonecrosis, after the femoral head. However, compared to osteonecrosis of the femoral head (ONFH), epidemiological information on osteonecrosis of the humeral head (ONHH) is scarce. We hypothesised that different biomechanical properties of the shoulder from the hip joint might present different epidemiological characteristics of ONHH from those of the ONFH. To evaluate epidemiological differences, we compared trends in the surgical treatment of ONHH and ONFH using the nationwide medical claims database of the Republic of Korea (ROK). METHODS: We analysed epidemiological data from the Health Insurance Review and Assessment (HIRA) database of the ROK between 2008 and 2018. HIRA database contains almost all medical information in an anonymised form, including demographics, diagnoses, and types of surgical procedures, generated through healthcare practices in ROK. The annual incidence rates of ONHH and ONFH were calculated based on the total number of the general population. Demographics, annual incidence, and the proportion of post-traumatic osteonecrosis and surgical procedures were compared according to the anatomical site and the affected year. RESULTS: The total number of patients treated for ONHH and ONFH during the study period was 1,028 and 66,260, respectively. Although the incidence of ONHH increased, it is a relatively rare disease compared to ONFH. ONHH occurred more frequently in females, while ONFH occurred predominantly in male patients (p < 0.001). Surgical treatment for ONHH was most frequently performed in older patients (63.7%), whereas middle-aged patients had the largest proportion of ONFH (48.9%, p < 0.001). The proportion of post-traumatic osteonecrosis was significantly higher in the ONHH (5.1%) than in the ONFH (1.9%, p < 0.001). Arthroplasty was performed more frequently in the ONHH (96.0%) than in the ONFH (92.9%, p < 0.001). CONCLUSION: Despite the anatomical similarities between the hip and shoulder joints, the different biomechanical properties, such as weight-bearing functions, might cause epidemiological differences between ONHH and ONFH.


Assuntos
Necrose da Cabeça do Fêmur , Cabeça do Fêmur , Pessoa de Meia-Idade , Feminino , Humanos , Masculino , Idoso , Articulação do Quadril , Necrose da Cabeça do Fêmur/cirurgia , Cabeça do Úmero/cirurgia , República da Coreia/epidemiologia
5.
BMC Musculoskelet Disord ; 24(1): 449, 2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37268896

RESUMO

BACKGROUND: The purpose of the Korean Hip Fracture Registry (KHFR) Study is to establish a nationwide, hospital-based prospective cohort study of adults with hip fracture to explore the incidence and risk factors of second osteoporotic fractures for a Fracture Liaison Service (FLS) model. METHODS: The KHFR, a prospective multicenter longitudinal study, was launched in 2014. Sixteen centers recruited participants who were treated for hip fracture. The inclusion criteria were patients, who were treated for proximal femur fracture due to low-energy trauma and aged 50 or more at the time of injury. Until 2018, 5,841 patients were enrolled in this study. Follow-up surveys were conducted annually to determine occurrence of second osteoporotic fracture, and 4,803 participants completed at least one follow-up survey. DISCUSSION: KHFR is a unique resource of individual level on osteoporotic hip fracture with radiological, medical, and laboratory information including DXA (dual energy x-ray absorptiometry), bone turnover marker, body composition, and hand grip strength for future analyses for FLS model. Modifiable factors for mortality after hip surgery is planned to be identified with nutritional assessment and multi-disciplinary interventions from hospitalization to follow-ups. The proportions of femoral neck, intertrochanteric, and subtrochanteric fractures were 517 (42.0%), 730 (53.6%), and 60 (4.4%), respectively, from 2014 to 2016, which was similar in other studies. Radiologic definition of atypical subtrochanteric fracture was adopted and 17 (1.2%) fractures among 1,361 proximal femoral fractures were identified. Internal fixation showed higher reoperation rate compared to arthroplasty in unstable intertrochanteric fractures (6.1% vs. 2.4%, p = 0.046) with no significant difference in mortality. The KHFR plans to identify outcomes and risk factors associated with second fracture by conducting a 10-year cohort study, with a follow-up every year, using 5,841 baseline participants. TRIAL REGISTRATION: Present study was registered on Internet-based Clinical Research and Trial management system (iCReaT) as multicenter prospective observational cohort study (Project number: C160022, Date of registration: 22th, Apr, 2016).


Assuntos
Fraturas do Quadril , Fraturas por Osteoporose , Adulto , Humanos , Estudos Prospectivos , Estudos de Coortes , Força da Mão , Estudos Longitudinais , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/cirurgia , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/epidemiologia , Fraturas por Osteoporose/cirurgia , Sistema de Registros , República da Coreia/epidemiologia
6.
J Korean Med Sci ; 38(20): e148, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37218351

RESUMO

BACKGROUND: This study aimed to 1) assess the effect of total hip arthroplasty (THA) on coronal limb alignment, namely, the hip-knee-ankle angle (HKA), 2) identify factors that determine changes in the HKA, and 3) determine whether alignment changes influence the knee joint space width. METHODS: We retrospectively evaluated 266 limbs of patients who underwent THA. Three types of prostheses with neck shaft angles (NSAs) of 132°, 135°, and 138° were used. Several radiographic parameters were measured in the preoperative and final radiographs (at least 5 years after THA). A paired t-test was used to confirm the effect of THA on HKA change. Multiple regression analysis was performed to identify radiographic parameters related to HKA changes following THA and changes in knee joint space width. Subgroup analyses were performed to reveal the effect of NSA change on the HKA change, and the proportion of total knee arthroplasty usage and changes in radiographic parameters between maintained joint space and narrowed joint space groups were compared. RESULTS: The preoperative mean HKA was 1.4° varus and increased to 2.7° varus after THA. This change was related to changes in the NSA, lateral distal femoral angle, and femoral bowing angle. In particular, in the group with a decrease in NSA of > 5°, the preoperative mean HKA was largely changed from 1.4° varus to 4.6° varus after THA. The prostheses with NSA of 132° and 135° also led to greater varus HKA changes than those with an NSA of 138°. Narrowing of the medial knee joint space was related to changes in the varus direction of the HKA, decrease in NSA, increase in femoral offset. CONCLUSION: A large reduction in NSA can lead to considerable varus limb alignment after THA, which can have adverse effects on the medial compartment of the ipsilateral knee.


Assuntos
Artroplastia de Quadril , Osteoartrite do Joelho , Humanos , Seguimentos , Estudos Retrospectivos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Extremidade Inferior/cirurgia , Tíbia
7.
Arthroscopy ; 39(9): 2012-2022.e1, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36965541

RESUMO

PURPOSE: To develop a radiographic measurement to evaluate the femoroacetabular space using 3-dimensional (3D) hip models in asymptomatic hips, and to evaluate the reliability and validity of the femoroacetabular excursion angle (FAEA) in symptomatic patients. METHODS: From January 2020 to December 2020, we recruited patients with healthy hips to establish 3D models. Through the simulation of 14 activities of daily living (ADLs), anterior and lateral impingement-free FAEAs were measured. Another cross-sectional cohort was formed from consecutive symptomatic subjects with impingement signs during the same period. In the validation cohort, anterior and lateral FAEAs were assessed on modified Dunn's and anteroposterior views of the hip, respectively. We evaluated the reliability and clinical implications of the FAEAs. RESULTS: In the discovery cohort (n = 33), hips with collisions tended to have smaller computed tomography-based FAEAs than collision-free hips, although alpha and lateral center-edge (CE) angles were comparable. Additionally, hips with a lower quartile of FAEAs had a significantly higher number of ADLs with collisions. In the validation cohort (n = 411), the FAEA measurement was highly reliable (kappa statistics >0.95 for both interobserver and intraobserver reliabilities). The femoroacetabular impingement syndrome (FAIS) group (n = 165) showed significantly smaller anterior and lateral FAEAs than the non-FAIS group (all P < .001, Cramer V = .420). The optimal cut-off values for anterior and lateral FAEAs were 32.6° and 48.9°, respectively. In univariate regression, anterior (odds ratio [OR] = 0.91; 95% confidence interval [CI] = 0.89-0.94) and lateral (OR = 0.91; 95% CI = 0.89-0.93) FAEAs were significantly associated with FAIS. Moreover, in multivariate regression adjusted for alpha and lateral CE angles, anterior FAEA remained a significant predictor (OR = 0.96; 95% CI = 0.93-0.99), and small FAEA was an independent risk factor for FAIS (OR = 1.99; 95% CI = 1.06-3.71) for any small FAEA (OR = 2.88; 95% CI = 1.32-6.31) for both small FAEAs. CONCLUSION: The FAEA is a valid measurement for FAIS with high reliability. Small FAEA was an independent risk factor for FAIS in the multivariate regression model, even after adjusting for alpha and lateral CE angles. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Impacto Femoroacetabular , Humanos , Impacto Femoroacetabular/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Estudos Transversais , Reprodutibilidade dos Testes , Atividades Cotidianas , Estudos de Coortes , Estudos Retrospectivos
8.
Arch Orthop Trauma Surg ; 143(8): 5385-5394, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36595032

RESUMO

BACKGROUND: We previously reported five-to-seven-year results of total hip arthroplasty (THA) with the use of delta ceramic-on-ceramic (CoC) bearing. We conducted an extension study with a CT scan at a minimum of 10 years after surgery. METHODS: From March 2009 to March 2011, 273 patients (310 hips) received cementless THA with delta CoC bearing, porous-coated cup and hydroxyapatite-coated stem. In this extended study, 252 patients (144 men and 108 women) (288 hips) with a mean age of 49.7 years (16-83) at surgery were followed for a mean of 10.4 years (10-12) with CT scans in 133 hips (46.2%, 133/288). Clinical and radiographic evaluations were made at each follow-up and Kaplan-Meier survival analysis was performed with revision and reoperation as endpoints. RESULTS: There were no more ceramic fractures. Compared to mid-term results, the incidence of squeaking and RLLs increased to 3.1% (9/288) and 19.4% (56/288), respectively. The RLL progressed to focal osteolysis in 3 hips (5.4%, 3/56). No hip had detectable wear or prosthetic loosening. Two hips were reoperated due to periprosthetic joint infection and periprosthetic femoral fracture in each. The survivorship decreased to 98.3% (96.7-99.9%) at 12 years. CONCLUSION: During the extended follow-up, no additional ceramic fracture occurred, and the incidence of squeak increased by 0.7%. The long-term survivorship of Delta CoC THA was encouraging. However, focal osteolysis occurred around the hydroxyapatite-coated stem in 1% (3/288). LEVEL OF EVIDENCE: II (Prospective cohort study).


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Fraturas Periprotéticas , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Seguimentos , Prótese de Quadril/efeitos adversos , Osteólise/etiologia , Estudos Prospectivos , Falha de Prótese , Fraturas Periprotéticas/cirurgia , Cerâmica , Desenho de Prótese , Hidroxiapatitas , Resultado do Tratamento , Articulação do Quadril/cirurgia
9.
J Bone Miner Metab ; 40(4): 688-695, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35639177

RESUMO

INTRODUCTION: Sarcopenia, loss of muscle mass and strength, leads to functional dependence and disability. To date, no study reported the postoperative change of sarcopenia prevalence after hip fractures. Thus, we assessed postoperative changes in the prevalence of osteoporosis and sarcopenia in hip fracture patients. MATERIALS AND METHODS: Among 1159 patients, who underwent surgery for low-energy hip fractures between May 2012 and December 2019, 224 patients (38 men and 186 women with a mean age of 76.8 ± 8.7 years) were studied with preoperative and follow-up dual-energy X-ray absorptiometry (DXA). Bone mineral density (BMD) and skeletal muscle mass were measured on DXA scans. The postoperative changes in the prevalence of osteoporosis and that of the sarcopenia were evaluated as well as Koval grade of the hip fracture patients. RESULTS: While there was no significant change in BMD, SMI significantly decreased postoperatively. Mean decrease of the SMI was 0.53 kg/m2 in men and 0.38 kg/m2 in women. Prevalence of sarcopenia increased from 63 to 89% (p = 0.014) in men and from 45 to 57% (p = 0.006) in women. Lower BMI (Odds ratio (OR) 0.85 (95% confidence interval (CI) 0.76-0.96), p = 0.008) and prior sarcopenia (OR 14.47 (95% CI 5.29-35.39), p < 0.001) were the risk factors for the decrease of SMI after hip fracture. CONCLUSIONS: After hip fracture, osteoporosis seemed to be well managed and the prevalence of osteoporosis did not increase. However, SMI decreased and the prevalence of sarcopenia increased. More active measures are warranted to prevent sarcopenia in elderly hip fracture patients.


Assuntos
Fraturas do Quadril , Osteoporose , Sarcopenia , Absorciometria de Fóton , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea/fisiologia , Feminino , Fraturas do Quadril/complicações , Fraturas do Quadril/epidemiologia , Humanos , Masculino , Osteoporose/epidemiologia , Sarcopenia/epidemiologia , Sarcopenia/etiologia
10.
Clin Orthop Relat Res ; 480(4): 690-699, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34699410

RESUMO

BACKGROUND: Recently, impingement between the femoral stem and ceramic liner, which appears as a notch in the stem neck on radiographs, has emerged as a new complication. However, the proportion of impingement, potential risk factors, and related complications are poorly elucidated. QUESTION/PURPOSES: In patients who underwent ceramic-on-ceramic (CoC) THA and had at least 10 years of follow-up, we asked: (1) What proportion had radiographic evidence of stem neck-ceramic liner impingement (notching of the stem), and what implant design, implantation factors, or complications such as ceramic fracture or metallosis are associated with impingement? (2) How common are the complications of noise and ceramic fracture? (3) What are the radiologic changes (including fixation of femoral and acetabular components, osteolysis, and heterotopic ossification) and clinical outcomes as determined by the modified Harris hip score (mHHS) for this cohort? (4) What is the survivorship with implant revision as the endpoint and with reoperation for any reason as the endpoint after CoC THA using a thick-neck stem design? METHODS: Between May 2003 and April 2010, 643 patients underwent primary THA at a tertiary referral hospital. After excluding patients with metal-on-polyethylene and with ceramic-on-polyethylene implants, 621 patients were considered eligible for this study. All patients received the same hemispherical titanium cup, a standard-length tapered titanium stem, and a CoC bearing. Of those, 19% (115) were lost to follow-up before 10 years, and 8% (50) were excluded because they died before the minimum follow-up duration of 10 years, leaving 73% (456) for analysis. Patients had a mean age of 50 ± 14 years and were followed for a median (range) of 13 years (10 to 17). The mean cup abduction was 38° ± 5°, and the mean cup anteversion was 26° ± 7°. To determine the proportion of patients with the neck-liner impingement, we analyzed the plain radiographs of every patient during follow-up to detect notches around the stem. The detection of stem neck notches on the radiographs was reliable (intraobserver reliability: κ = 0.963; p < 0.001 and interobserver reliability: κ = 0.975; p < 0.001). To evaluate factors related to notching, we compared the possible confounding factors including gender, age, BMI, implant position, neck length, and head diameter. Complications such as ceramic fracture, noise, dislocation, and periprosthetic joint infection were recorded. Noise was evaluated via interview and with the Hip Noise Assessment Questionnaire, which assessed the noise qualitatively. For clinical outcome, we assessed the mHHS, which includes pain and function scales (0 [worst] to 100 [best]), every visit. Tilting of at least 4° or migration of at least 4 mm was the criteria for cup loosening; subsidence more than 3 mm, any change in position, or a continuous radiolucent line greater than 2 mm was the criteria for stem loosening. To evaluate osteolysis, we performed CT scans in 57% (262 of 456) of patients. Kaplan-Meier survivorship analysis was performed using the endpoints of survivorship free from implant revision and survivorship free from reoperation for any cause. RESULTS: The proportion of stem neck notching was 11% (49 of 456). There were no differences in cup abduction and anteversion between hips with notches and those without notches. Notched hips were more likely to have 28-mm than 32-mm heads (90% [44 of 49] versus 70% [285 of 407]; odds ratio 3.77 [95% CI 1.46 to 9.73]; p = 0.004). None of the 49 notched hips had a ceramic head or liner fracture or evidence of metallosis. A ceramic head fracture was reported in 2% (9 of 456); all fractures occurred in 28-mm short neck heads. A ceramic liner fracture occurred in 0.2% (1 of 456), and noise was noted in 6% (27 of 456). Acetabular osteolysis developed in 2% (7 of 456). The mHHS was 91 ± 12 points at the final follow-up. The survivorship free from implant revision was 97% (95% CI 96% to 99%), and the survivorship free from reoperation for any cause was 96% (95% CI 95% to 98%) at 13 years. CONCLUSION: The proportion of stems with neck-ceramic liner impingement and ceramic component fracture were unacceptably high after the use of a thick-neck stem design, especially when a 28-mm head was used. We have discontinued the use of this stem design and we recommend that such stems should not be used when CoC bearings are used. As these findings might be generalized to other bearing couples, further studies focused on polyethylene liner wear and local metallosis due to thick stem neck are warranted. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Adulto , Artroplastia de Quadril/efeitos adversos , Cerâmica , Colo do Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Pessoa de Meia-Idade , Osteólise/etiologia , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Titânio , Resultado do Tratamento
11.
J Korean Med Sci ; 37(2): e7, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35014223

RESUMO

BACKGROUND: At the end of 2014, we implemented an online video to inform patients of the entire process from admission to rehabilitation after total hip arthroplasty (THA). In this study, we investigated the effectiveness of online video instruction in THA patients. METHODS: Electronic medical records of 184 patients undergoing THA in 2014 (pre-video group) and 182 patients in 2015 (post-video group) were reviewed. We compared 1) the time to start wheelchair ambulation, 2) walker or crutch ambulation, 3) the length of hospital stay, 4) postoperative satisfaction using visual analogue scale (0-10 points), and 5) modified Harris Hip Score (mHHS) at postoperative 6 weeks. RESULTS: In the post-video group, the time to start wheelchair ambulation (1.8 ± 0.6 vs. 2.4 ± 3.2 days, P = 0.021) and walker/crutch ambulation were faster (2.9 ± 1.2 vs. 3.8 ± 1.0 days, P = 0.016), and the hospital stay was shorter (8.2 ± 4.7 vs. 9.9 ± 7.8 days, P = 0.001) compared to the pre-video group. The visual analogue scale for satisfaction (7.84 ± 1.62 vs. 7.68 ± 1.85 points) and mHHS (89.59 ± 9.47 vs. 89.58 ± 8.59) were similar. CONCLUSION: Online video instruction is an effective tool to expedite ambulation and reduce the hospital stay without compromising the clinical outcome and postoperative complications after THA.


Assuntos
Artroplastia de Quadril , Deambulação Precoce , Educação a Distância , Tempo de Internação , Educação de Pacientes como Assunto/métodos , Satisfação do Paciente , Recuperação de Função Fisiológica , Gravação em Vídeo , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
12.
J Arthroplasty ; 37(11): 2308-2315.e2, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35568139

RESUMO

BACKGROUND: Highly cross-linked polyethylene (HXLPE) liners have been developed to address the wear-related problems associated with conventional polyethylene (CPE) such as osteolysis or aseptic loosening in total hip arthroplasty (THA). In this systematic meta-analysis, we compared the long-term efficacy in preventing radiological osteolysis and revision surgery between HXLPE and CPE. METHODS: We included 14 studies that compared HXLPE and CPE reporting the incidence of wear-related complications with a minimum follow-up of 10 years. We investigated 5 wear-related complications: osteolysis, excessive wear, linear wear rate, revision surgery due to wear, and progress of osteolysis/aseptic loosening. We conducted a pair-wise meta-analysis to estimate odds ratio (OR) and a proportional meta-analysis to estimate the incidence of each complication. RESULTS: Among 1,175 THAs, 220 osteolysis and 78 wear-related revisions were detected. The use of HXLPE reduced the risk of overall osteolysis (OR 0.30; P = .001), excessive wear (OR 0.10; P < .001), linear wear rate (weighted mean difference 0.09; P < .001), the risk of overall wear-related revisions (OR 0.06; P < .001), and revisions due to aseptic loosening (OR 0.23; P = .015). As per the proportional meta-analysis, the pooled prevalence of osteolysis, excessive wear, and the overall wear-related revision rate were 14%, 8%, and 3% in HXLPE and 25%, 33%, and 20% in CPE, respectively. CONCLUSION: The current evidence shows that HXLPE dramatically reduced the rate of osteolysis and wear-related revision surgery. However, as polyethylene wear and osteolysis still lead to revision surgery, ongoing clinical and retrieval studies are required to analyze long-term outcomes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Artroplastia de Quadril/efeitos adversos , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Osteólise/epidemiologia , Osteólise/etiologia , Osteólise/prevenção & controle , Polietileno , Desenho de Prótese , Falha de Prótese
13.
J Pediatr Orthop ; 42(3): e295-e300, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35051955

RESUMO

BACKGROUND: In patients with leg length discrepancy (LLD) and consequent pelvic obliquity, either the longitudinal axis of the pelvis or a line perpendicular to the ground may be used as the longitudinal reference line for measuring the lateral center-edge angle (LCEA). We aimed to (1) systematically inspect which longitudinal reference line has been used for measuring the LCEA in previous studies; (2) evaluate the frequency of change in the radiographical classification of acetabular overcoverage or undercoverage per the longitudinal reference line; and (3) validate the trigonometric method, predicting the change in the LCEA according to the LLD. METHODS: Studies investigating the LCEA published between January 1976 and July 2019 in the MEDLINE database were categorized according to the longitudinal reference line used. Further, in a retrospective analysis of 238 patients surgically treated for LLD, the LCEA was first measured on standing pelvic radiographs using the longitudinal axis of the pelvis (pLCEA) and measured again using a line perpendicular to the ground (gLCEA). Femoral head coverage was categorized as undercoverage, normal, or overcoverage based on the pLCEA and gLCEA. The theoretically calculated difference between the pLCEA and gLCEA (dLCEA) as determined using a trigonometric method was compared with the dLCEA measured on radiographs. RESULTS: Of 229 previous studies, 188 did not specify the longitudinal reference line. The number of patients who were diagnosed with acetabular overcoverage using the pLCEA and gLCEA was one and fourteen, respectively (P<0.001). The number of patients who were diagnosed with acetabular undercoverage using the pLCEA and gLCEA was one and zero, respectively (P=1.000). There was no difference (P=0.433) between the theoretically calculated (9±5 degrees) and measured (9±5 degrees) dLCEAs. CONCLUSIONS: The definition of the longitudinal reference line should be clarified when measuring the LCEA. The trigonometric method can accurately predict the change in the LCEA according to LLD in concentric hips without proximal femoral and pelvic deformities. LEVEL OF EVIDENCE: Level IV-diagnostic study.


Assuntos
Articulação do Quadril , Perna (Membro) , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cabeça do Fêmur , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Estudos Retrospectivos
14.
J Arthroplasty ; 37(6): 1074-1082, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35151809

RESUMO

BACKGROUND: The Association Research Circulation Osseous developed a novel classification for early-stage (precollapse) osteonecrosis of the femoral head (ONFH). We hypothesized that the novel classification is more reliable and valid when compared to previous 3 classifications: Steinberg, modified Kerboul, and Japanese Investigation Committee classifications. METHODS: In the novel classification, necrotic lesions were classified into 3 types: type 1 is a small lesion, where the lateral necrotic margin is medial to the femoral head apex; type 2 is a medium-sized lesion, with the lateral necrotic margin being between the femoral head apex and the lateral acetabular edge; and type 3 is a large lesion, which extends outside the lateral acetabular edge. In a derivation cohort of 40 early-stage osteonecrotic hips based on computed tomography imaging, reliabilities were evaluated using kappa coefficients, and validities to predict future femoral head collapse by chi-squared tests and receiver operating characteristic curve analyses. The predictability for future collapse was also evaluated in a validation cohort of 104 early-stage ONFH. RESULTS: In the derivation cohort, interobserver reliability (k = 0.545) and intraobserver agreement (63%-100%) of the novel method were higher than the other 3 classifications. The novel classification system was best able to predict future collapse (P < .05) and had the best discrimination between non-progressors and progressors in both the derivation cohort (area under the curve = 0.692 [0.522-0.863], P < .05) and the validation cohort (area under the curve = 0.742 [0.644-0.841], P = 2.46 × 10-5). CONCLUSION: This novel classification is a highly reliable and valid method of those examined. Association Research Circulation Osseous recommends using this method as a unified classification for early-stage ONFH. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Necrose da Cabeça do Fêmur , Cabeça do Fêmur , Acetábulo/patologia , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/patologia , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
15.
Int Orthop ; 46(4): 725-732, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34799778

RESUMO

INTRODUCTION: Inadequate stem version might lead to impingement and instability after cementless total hip arthroplasty (THA). We evaluated (1) the distribution of short-stem anteversion, (2) the proportion of stems with an anteversion less than 5° or larger than 25°, (3) combined cup and stem anteversion, and (4) dislocation rate. MATERIALS AND METHODS: We evaluated the native femoral anteversion and stem anteversion in 340 patients (340 THAs): 144 men and 196 women. Their mean age was 56.2 (22-87) years and mean body mass index was 25.1 (15.2-40.7) kg/m2. The femoral neck anteversion was measured on pre-operative CT scan and the stem anteversion was obtained during the operation. The safe zone of the stem anteversion was defined as 5 to 25°. RESULTS: The femoral neck anteversion ranged from -15 to 61° (mean, 15.0°; SD, ±10.6°). The stem anteversion ranged -7 to 50° (mean, 15.7°; SD, ±9.5°). It was optimal (5-25°) in 71.2% (242/340), insufficient (<5°) in 13.3% (45/340), and excessive (>25°) in 15.6% (53/340). The stem anteversion had a medium correlation with the femoral neck anteversion (correlation coefficient = 0.449). The combined anteversion was 42.0° (range, 35.2-52.3°; SD, ±2.8°). During two to four year follow-up, no hip dislocated. CONCLUSIONS: Short-length stem had a great variability in the anteversion and considerable portion (28.9%, 98/340) of stems had an anteversion outside the safe zone. Surgeons should be aware of this variability of stem anteversion to compensate for abnormal stem anteversion, which might lead to impingement and instability after THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Artroplastia de Quadril/efeitos adversos , Feminino , Fêmur/cirurgia , Humanos , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
16.
J Bone Miner Metab ; 39(2): 193-200, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32683499

RESUMO

INTRODUCTION: The purpose of our study was to evaluate the incidence and to identify risk factors of subsequent vertebral fractures after hip fractures, and to determine whether the subsequent vertebral fracture increases the mortality rate of elderly hip fracture patients. MATERIALS AND METHODS: From January 2009 to July 2016, 1,554 patients were diagnosed as having a hip fracture and were treated surgically at our institution. Among them, 1121 patients age > 50 years at the time of injury and were followed up for 1 year or longer after the hip fracture surgery. In these patients, radiographs of the hip and spine were taken at each follow-up. We reviewed medical records and radiographs of these patients. Among the 1121 patients, 107 patients (9.5%) had subsequent vertebral fractures after the hip fracture during entire follow-up periods. RESULTS: In multivariable analysis, previous history of vertebral fracture [odds ratio (OR), 2.62; p < 0.001], medication possession rate (MPR) of osteoporosis treatment < 80% (OR, 1.92; p = 0.014), and a lower lumbar bone mineral density (BMD) (OR, 2.58; p = 0.001) appeared as risk factors for subsequent vertebral fractures. CONCLUSION: However, the subsequent vertebral fractures did not affect the mortality after the hip fractures. Age ≥ 70 years [hazard ration (HR) 2.70; p = .039], body mass index < 18.5 kg/m2 (HR, 2.57; p =0 .048), and Charlson comorbidity index ≥ 2 (HR, 2.04; p =0.036) were risk factors of the death. Timely management is warranted to prevent subsequent vertebral fractures in hip fracture patients with risk factors.


Assuntos
Fraturas do Quadril/complicações , Fraturas da Coluna Vertebral/epidemiologia , Fraturas da Coluna Vertebral/etiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas do Quadril/mortalidade , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Radiografia , Fatores de Risco
17.
Clin Orthop Relat Res ; 479(4): 767-777, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33009239

RESUMO

BACKGROUND: Short-length stems were developed to reduce bone loss of the proximal femur and potentially decrease the incidence of thigh pain after cementless THA. However, it remains unknown whether short stems indeed reduce bone loss or the frequency of thigh pain. QUESTIONS/PURPOSES: Is there a difference between short- and standard-length stems in terms of: (1) the frequency or severity of thigh pain, (2) modified Harris hip scores, (3) implant loosening, or (4) bone mineral density as measured by dual-energy x-ray absorptiometry? METHODS: Between March 2013 and January 2014, three surgeons performed 205 primary THAs. To be eligible, patients needed to be at least 20 years of age, have not undergone previous history of hip surgery, and have no metabolic bone disease. A total of 100 patients were randomized to receive THA either with a short stem (n = 56) or with a standard-length stem (n = 44). Both stems were proximally coated, tapered, cementless stems. Compared with standard stems, short stems typically were 30- to 35-mm shorter. A total of 73% (41 of 56) and 77% (34 of 44) of those groups, respectively, were accounted for at a minimum of 5 years and were analyzed. The presence of thigh pain during activity was evaluated using a 10-point VAS, and the modified Harris hip score was calculated by research assistants who were blinded to the treatment groups. Plain radiographs were taken at 6 weeks, 6 months, and 12 months postoperatively, and every 1 year thereafter; loosening was defined as subsidence > 3 mm or a position change > 3° on serial radiographs. Radiological assessment was performed by two researchers who did not participate in the surgery and follow-up evaluations. Bone mineral density of the proximal femur was measured using dual-energy x-ray absorptiometry at 4 days, 1 year, 2 years, and 5 years postoperatively. The primary endpoint of our study was the incidence of thigh pain during 5-year follow-up. Our study was powered at 80% to detect a 10% difference in the proportion of patients reporting thigh pain at the level of 0.05. RESULTS: With the numbers available, we found no difference between the groups in the proportion of patients with thigh pain; 16% (9 of 56) of patients in the short-stem group and 14% (6 of 44) of patients in the standard-stem group experienced thigh pain during the follow-up period (p = 0.79). In all patients, the pain was mild or moderate (VAS score of 4 or 6 points). Among the 15 available patients who reported thigh pain, there was no difference between the implant groups in mean severity of thigh pain (4.3 ± 0.8 versus 4.2 ± 0.7; p = 0.78). There were no between-group differences in the short versus standard-length stem groups in terms of mean modified Harris hip score by 5 years after surgery (89 ± 13 versus 95 ± 7 points; p = 0.06). No implant was loose and no hip underwent revision in either group. Patients in the short-stem group showed a slightly smaller decrease in bone mineral density in Gruen Zones 2, 3, and 5 than those in the standard-stem group did; the magnitude of the difference seems unlikely to be clinically important. CONCLUSION: We found no clinically important differences (and few differences overall) between short and standard-length THA stems 5 years after surgery in a randomized trial. Consequently, we recommend that clinicians use standard-length stems in general practice because standard-length stems have a much longer published track record in other studies, and short stems can expose patients to the uncertainty associated with novelty, without any apparent offsetting benefit. LEVEL OF EVIDENCE: Level I, therapeutic study.


Assuntos
Artralgia/prevenção & controle , Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Osteoporose/prevenção & controle , Dor Pós-Operatória/prevenção & controle , Absorciometria de Fóton , Adulto , Artralgia/diagnóstico , Artralgia/etiologia , Artralgia/fisiopatologia , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Densidade Óssea , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/diagnóstico por imagem , Osteoporose/etiologia , Osteoporose/fisiopatologia , Medição da Dor , Limiar da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/fisiopatologia , Desenho de Prótese , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , República da Coreia , Fatores de Tempo , Resultado do Tratamento
18.
BMC Musculoskelet Disord ; 22(1): 375, 2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33888097

RESUMO

BACKGROUND: The annual number of hip arthroplasties is increasing combined with the aging population worldwide. In accordance with the increasing number of primary hip arthroplasties, the number of revision total hip arthroplasties (THAs) is expected to increase. The incidence and burden of revision THAs in the United States and have been reported by registry studies. To identify potential differences according to ethnics and regional practice, it is important to obtain data from East Asia. Nevertheless, there has been a lack of studies on the burden and future projection of revision THA based on a large-scale database in East Asia. The purpose of this study was to evaluate annual incidence and burden of revision THAs and to project the future burden in South Korea. METHODS: We identified primary THAs, primary hemiarthroplasties (HAs) and revision THAs, which were performed from 2010 to 2018, using database of Health Insurance and Review and Assessment (HIRA); nation-wide medical claim system of South Korea. The annual incidence rates (per 100,000) of primary THA, primary HA and revision THA, and the annual burden of revision THA; the number of revision THAs divided by the sum of primary hip arthroplasties and revision THAs, were calculated. The future burden of revision THAs were projected through 2030 using generalized linear model with Quasi-poisson regression. RESULTS: During the 9-year period, the annual incidences of primary THA, primary HA and revision THA increased by 47, 29 and 3%, respectively, while the revision burden decreased from 0.13 to 0.10. Compared to 2018, the annual incidences of primary THA, HA, and revision THA were projected to increase by 7.2, 2.3 and 1.1% per year, respectively, whereas the burden of revision THA was projected to decrease to 0.07 in 2030. CONCLUSION: Trends of revision THA in South Korea were similar with those of national registry studies from the United States. The annual incidence of revision THA has steadily increased, whereas its burden has decreased. Findings of our study could be used for epidemiological comparison between Western countries and East Asia as well as for the establishment of medical policies of revision THA in East Asian countries.


Assuntos
Artroplastia de Quadril , Hemiartroplastia , Prótese de Quadril , Idoso , Artroplastia de Quadril/efeitos adversos , Previsões , Prótese de Quadril/efeitos adversos , Humanos , Reoperação , República da Coreia/epidemiologia , Estados Unidos
19.
J Korean Med Sci ; 36(24): e177, 2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34155839

RESUMO

Non-traumatic osteonecrosis of the femoral head (ONFH) usually affects adults younger than 50 years and frequently leads to femoral head collapse and subsequent arthritis of the hip. It is becoming more prevalent along with increasing use of corticosteroids for the adjuvant therapy of leukemia and other myelogenous diseases as well as management of organ transplantation. This review updated knowledge on the pathogenesis, classification criteria, staging system, and treatment of ONFH.


Assuntos
Necrose da Cabeça do Fêmur/classificação , Necrose da Cabeça do Fêmur/patologia , Cabeça do Fêmur/patologia , Glucocorticoides/efeitos adversos , Quadril/patologia , Osteonecrose/terapia , Humanos , Osteonecrose/patologia , Prednisolona/efeitos adversos
20.
J Hand Surg Am ; 46(11): 1026.e1-1026.e7, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33867200

RESUMO

PURPOSE: To develop and validate identification criteria for distal radius fractures (DRFs) and their treatment using a national health insurance database. METHODS: Patients who had at least 1 wrist radiograph taken in 2018 were recruited from a single academic referral hospital. After excluding patients who lacked immobilization code for wrist pathology, we collected data on the overall population. Because some patients might have undergone wrist radiography at another institution or had DRFs without an immobilization code, we additionally included patients who had a DRF diagnosis code at our institution. Reviews of medical records and wrist radiographs were considered for the diagnosis of DRF. We evaluated the sensitivity, specificity, and positive predictive value (PPV) of 3 operational definitions of fractures that were based on a single primary or secondary diagnosis code; all diagnosis codes, including primary and secondary codes; and all diagnosis and procedure codes. RESULTS: Among 768 patients included in the study, true DRFs were confirmed in 305. The sensitivity, specificity, and PPV for definition 1 were 91.5% (95% CI, 88.3%-94.6%), 97.5% (95% CI, 95.9%-99.1%), and 96.9% (95% CI, 94.9%-98.9%), respectively. Although the sensitivity of definition 2 was higher (92.1%; 95% CI, 89.1%-95.2%), its specificity and PPV were lower (96.4% [95% CI, 94.4%-98.3%] and 95.6% [95% CI, 93.2%-97.9%], respectively). The sensitivity of definition 3 was the lowest (88.2%; 95% CI, 84.6%-91.8%), but its specificity and PPV were the highest among the 3 definitions (98.6% [95% CI, 97.4%-98.8%] and 98.2% [95% CI, 96.6%-99.8%], respectively). CONCLUSIONS: Patients with DRFs can be identified from claims databases with high accuracy using an operational definition based on DRF diagnosis and procedure codes, including codes for surgical and nonoperative methods. CLINICAL RELEVANCE: Verified operational definitions will increase the consistency of results in future national health insurance database studies related to DRFs.


Assuntos
Fraturas do Rádio , Bases de Dados Factuais , Humanos , Programas Nacionais de Saúde , Valor Preditivo dos Testes , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/epidemiologia , Projetos de Pesquisa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA