Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Prosthet Dent ; 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38797573

RESUMO

STATEMENT OF PROBLEM: Interest is growing in immediately loading definitive implant-supported prostheses. However, it appears that implant protocols are evolving faster than their scientific validation. PURPOSE: The purpose of this scoping review was to identify the current trends, feasibility, and clinical outcomes of a specific clinical loading scenario (type A), where a single definitive implant-retained restoration is delivered within 3 days. The focus question was "In partially edentulous patients requiring an implant-retained prosthesis (population), is immediate loading with a definitive restoration (concept) a viable treatment option (context)?" MATERIAL AND METHODS: An electronic search was conducted in the PubMed, CENTRAL, Scopus, Embase, and Web of Science databases. Two authors independently reviewed the studies, screened titles and abstracts, and performed full-text analysis. Cross-reference checks within the bibliography of included studies, relevant reviews, and guideline were conducted. Bibliometric information and study details were extracted. RESULTS: The search identified 2568 titles after removing duplicates. Four studies involving 91 participant and 100 implant-retained restorations were included in this scoping review. The selected articles were a randomized controlled trial (RCT), a prospective clinical study, and the remaining 2 were case series. The follow-up periods investigated ranged from 6 to 26 months. All studies evaluated marginal bone loss as a primary outcome, and only 1 implant failure was reported. Patient-reported outcome measures were favorable, and no major biological or technical complications were reported in any study. CONCLUSIONS: Immediate loading with a definitive restoration within 3 days appears to be a suitable approach in specific clinical situations.

2.
Sensors (Basel) ; 22(24)2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36560143

RESUMO

Federated learning is a type of distributed machine learning in which models learn by using large-scale decentralized data between servers and devices. In a short-range wireless communication environment, it can be difficult to apply federated learning because the number of devices in one access point (AP) is small, which can be small enough to perform federated learning. Therefore, it means that the minimum number of devices required to perform federated learning cannot be matched by the devices included in one AP environment. To do this, we propose to obtain a uniform global model regardless of data distribution by considering the multi-AP coordination characteristics of IEEE 802.11be in a decentralized federated learning environment. The proposed method can solve the imbalance in data transmission due to the non-independent and identically distributed (non-IID) environment in a decentralized federated learning environment. In addition, we can also ensure the fairness of multi-APs and determine the update criteria for newly elected primary-APs by considering the learning training time of multi-APs and energy consumption of grouped devices performing federated learning. Thus, our proposed method can determine the primary-AP according to the number of devices participating in the federated learning in each AP during the initial federated learning to consider the communication efficiency. After the initial federated learning, fairness can be guaranteed by determining the primary-AP through the training time of each AP. As a result of performing decentralized federated learning using the MNIST and FMNIST dataset, the proposed method showed up to a 97.6% prediction accuracy. In other words, it can be seen that, even in a non-IID multi-AP environment, the update of the global model for federated learning is performed fairly.

3.
Clin Oral Implants Res ; 31(12): 1187-1198, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32905643

RESUMO

OBJECTIVE: To determine the positional accuracy of implants placed with a three-dimensionally printed template having nonmetal sleeves and to determine the contributing factors to observed deviations. MATERIALS AND METHODS: One hundred and eighty-seven implants placed in 72 patients were analyzed. Presurgical intraoral scans and cone-beam computed tomography images obtained before and after surgery were superimposed, and vertical, angular, platform, and apex deviations were measured between the virtually planned and actually placed positions. A multiple linear regression model was designed for identifying the contributing factors. Statistical significance was set at p < .05, with Bonferroni correction if necessary (p < .0167). RESULTS: A total of 187 implants demonstrated deviations of 0.65 [0.56, 0.75] mm (mean [95% confidence interval]) vertically, 3.59° [3.30°, 3.89°] angularly, 1.16 [1.04, 1.28] mm at platform, and 1.50 [1.36, 1.65] mm at apex. Implants placed in the mandible showed larger angular, platform, and apex deviations compared with those in the maxilla (p = .049, p = .014 and p = .003, respectively). Implants placed at the third or fourth nearest sites from the most-distal tooth had larger deviations than those placed at the first or second nearest sites, in vertical, platform, and apical aspects (p = .015, p = .011 andp = .018, respectively). This was only applicable to free-ending-supported templates (p < .0167), and anchor pin-supported free-ending templates (p < .0167). CONCLUSION: Using a three-dimensionally printed surgical template with a nonmetal sleeve in the partial edentulous ridge resulted in larger deviations in implants placed in the mandible or distal free-end third or fourth nearest site.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Humanos , Imageamento Tridimensional , Estudos Prospectivos , Análise de Regressão
4.
Sensors (Basel) ; 20(14)2020 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-32679715

RESUMO

The communication and connectivity functions of vehicles increase their vulnerability to hackers. The unintended failure and malfunction of in-vehicle systems caused by external factors threaten the security and safety of passengers. As the controller area network alone cannot protect vehicles from external attacks, techniques to analyze and detect external attacks are required. Therefore, we propose a multi-labeled hierarchical classification (MLHC) intrusion detection model that analyzes and detects external attacks caused by message injection. This model quickly determines the occurrence of attacks and classifies the attack using only existing classified attack data. We evaluated the performance of the model by analyzing its learning space. We further verified the model by comparing its accuracy, F1 score and data learning and evaluation times with the two layers multi-class detection (TLMD) and single-layer multi-class classification (SLMC) models. The simulation results show that the MLHC model has the highest F1 score of 0.9995 and is 87.30% and 99.92% faster than the SLMC and TLMD models in terms of detection time, respectively. Consequently, the proposed model can classify both the type and existence or absence of attacks with high accuracy and can be used in interior communication environments of high-speed vehicles with a high throughput.

5.
Plant Physiol ; 173(1): 825-835, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27899534

RESUMO

Gibberellin (GA) is a major plant hormone that regulates plant growth and development and is widely used as a plant growth regulator in agricultural production. There is an increasing demand for function-limited GA mimics due to the limitations on the agronomical application of GA to crops, including GA's high cost of producing and its leading to the crops' lodging. AC94377, a substituted phthalimide, is a chemical that mimics the growth-regulating activity of GAs in various plants, despite its structural difference. Although AC94377 is widely studied in many weeds and crops, its mode of action as a GA mimic is largely unknown. In this study, we confirmed that AC94377 displays GA-like activities in Arabidopsis (Arabidopsis thaliana) and demonstrated that AC94377 binds to the Arabidopsis GIBBERELLIN INSENSITIVE DWARF1 (GID1) receptor (AtGID1), forms the AtGID1-AC94377-DELLA complex, and induces the degradation of DELLA protein. Our results also indicated that AC94377 is selective for a specific subtype among three AtGID1s and that the selectivity of AC94377 is attributable to a single residue at the entrance to the hydrophobic pocket of GID1. We conclude that AC94377 is a GID1 agonist with selectivity for a specific subtype of GID1, which could be further developed and used as a function-limited regulator of plant growth in both basic study and agriculture.


Assuntos
Proteínas de Arabidopsis/agonistas , Arabidopsis/efeitos dos fármacos , Ftalimidas/química , Ftalimidas/farmacologia , Receptores de Superfície Celular/agonistas , Arabidopsis/metabolismo , Proteínas de Arabidopsis/química , Proteínas de Arabidopsis/genética , Proteínas de Arabidopsis/metabolismo , Germinação/efeitos dos fármacos , Giberelinas/metabolismo , Hipocótilo/efeitos dos fármacos , Ftalimidas/metabolismo , Plantas Geneticamente Modificadas , Receptores de Superfície Celular/química , Receptores de Superfície Celular/genética , Receptores de Superfície Celular/metabolismo , Transdução de Sinais/efeitos dos fármacos , Nicotiana/genética
6.
Methods ; 129: 33-40, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-28323040

RESUMO

A "miRNA sponge" is an artificial oligonucleotide-based miRNA inhibitor containing multiple binding sites for a specific miRNA. Each miRNA sponge can bind and sequester several miRNA copies, thereby decreasing the cellular levels of the target miRNA. In addition to developing artificial miRNA sponges, scientists have sought endogenous RNA transcripts and found that long non-coding RNAs, competing endogenous RNAs, pseudogenes, circular RNAs, and coding RNAs could act as miRNA sponges under precise conditions. Here we present a computational approach for the prediction of endogenous human miRNA sponge candidates targeting viral miRNAs derived from pathogenic human viruses. Viral miRNA binding sites were predicted using a newly-developed machine learning-based method, and candidate interactions between miRNAs and sponge RNAs were experimentally validated using luciferase reporter assay, western blot analysis, and flow cytometry. We found that BX649188.1 functions as a potential natural miRNA sponge against kshv-miR-K12-7-3p.


Assuntos
MicroRNAs/genética , RNA Longo não Codificante/genética , RNA Viral/genética , RNA/genética , Sítios de Ligação , Humanos , Aprendizado de Máquina , MicroRNAs/isolamento & purificação , Oligonucleotídeos/genética , RNA/isolamento & purificação , RNA Circular , RNA Viral/isolamento & purificação
7.
Biosci Biotechnol Biochem ; 80(6): 1029-36, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26927225

RESUMO

The researches on the identification of gibberellin receptor are reviewed from the early attempts in 1960s to the identification of GIBBERELLIN INSENSITIVE DWARF1 (GID1) as the receptor in 2005. Unpublished data of the gibberellin-binding protein in the seedlings of adzuki bean (Vigna angularis) are also included, suggesting that the active principle of the gibberellin-binding protein was a GID1 homolog.


Assuntos
Proteínas de Arabidopsis/metabolismo , Arabidopsis/metabolismo , Proteínas de Transporte/metabolismo , Regulação da Expressão Gênica de Plantas , Giberelinas/metabolismo , Fosfoproteínas/metabolismo , Reguladores de Crescimento de Plantas/metabolismo , Proteínas de Plantas/metabolismo , Receptores de Superfície Celular/metabolismo , Vigna/metabolismo , Arabidopsis/genética , Proteínas de Arabidopsis/genética , Proteínas de Transporte/genética , Membrana Celular/metabolismo , Fosfoproteínas/genética , Células Vegetais/metabolismo , Proteínas de Plantas/genética , Ligação Proteica , Receptores de Superfície Celular/genética , Plântula/genética , Plântula/metabolismo , Transdução de Sinais , Vigna/genética
8.
Biosci Biotechnol Biochem ; 78(11): 1839-49, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25351332

RESUMO

Brassinosteroid (BR) and auxin co-regulate plant growth in a process termed cross-talking. Based on the assumption that their signal transductions are partially shared, inhibitory chemicals for both signal transductions were screened from a commercially available library. A chemical designated as NJ15 (ethyl 2-[5-(3,5-dichlorophenyl)-1,2,3,4-tetrazole-2-yl]acetate) diminished the growth promotion of both adzuki bean epicotyls and Arabidopsis seedlings, by the application of either BR or auxin. To understand its target site(s), bioassays with a high dependence on the signal transduction of either BR (BR-signaling) or auxin (AX-signaling) were performed. NJ15 inhibited the photomorphogenesis of Arabidopsis seedlings grown in the dark, which mainly depends on BR-signaling, while NJ15 also inhibited their gravitropic responses mainly depending on AX-signaling. On the study for the structure-activity relationships of NJ15 analogs, they showed strong correlations on the inhibitory profiles between BR- and AX-signalings. These correlations imply that NJ15 targets the downstream pathway after the integration of BR- and AX-signals.


Assuntos
Acetatos/farmacologia , Arabidopsis/efeitos dos fármacos , Escuridão , Fabaceae/efeitos dos fármacos , Ácidos Indolacéticos/farmacologia , Luz , Bibliotecas de Moléculas Pequenas/farmacologia , Tetrazóis/farmacologia , Acetatos/química , Acetatos/isolamento & purificação , Arabidopsis/crescimento & desenvolvimento , Proteínas de Arabidopsis/genética , Brassinosteroides/metabolismo , Brassinosteroides/farmacologia , Fabaceae/crescimento & desenvolvimento , Regulação da Expressão Gênica de Plantas/efeitos dos fármacos , Ácidos Indolacéticos/metabolismo , Mutação , Fotoperíodo , Transdução de Sinais/efeitos dos fármacos , Tetrazóis/química , Tetrazóis/isolamento & purificação
9.
Sci Rep ; 14(1): 7787, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565933

RESUMO

This retrospective study aimed to determine risk factors associated with post-operative bleeding after dentoalveolar surgery in patients taking anticoagulants. Patients taking anticoagulants who were planned to undergo periodontal flap operation, tooth extraction or implant surgery were included. Patients were divided into two subgroups according to the maintenance of anticoagulants following medical consultation: (1) maintenance group and (2) discontinuation group. The analysed patient-related factors included systemic diseases, maintenance of anticoagulants and types of anticoagulant. Intra- and post-operative treatment-related factors, haemostatic methods and post-operative bleeding were collected for statistical analyses. There were 35 post-operative bleeding complications (6.5%) in the 537 included patients: 21 (8.6%) in maintenance group and 14 (4.8%) in discontinuation group. The type of anticoagulant (p = 0.037), tooth extraction combined with bone grafting (p = 0.016) and type of implant surgery (p = 0.032) were significantly related to the post-operative bleeding rate. In the maintenance group, atrial fibrillation [odds ratio (OR) = 6.051] and vitamin K inhibitors (OR = 3.679) were associated with a significantly higher bleeding risk. From this result, it can be inferred that the decision to continue anticoagulants should be made carefully based on the types of anticoagulant and the characteristics of dentoalveolar surgeries performed: extraction with bone grafting, multiple implantations and involvement of maxillary arch.


Assuntos
Anticoagulantes , Fibrilação Atrial , Humanos , Anticoagulantes/efeitos adversos , Estudos de Coortes , Estudos Retrospectivos , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/induzido quimicamente , Extração Dentária/efeitos adversos , Fibrilação Atrial/complicações , Administração Oral
10.
Bioorg Med Chem Lett ; 23(4): 1096-8, 2013 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23298808

RESUMO

We applied a yeast two-hybrid (Y2H) system to the high-throughput monitoring of two proteins' interaction, a receptor for phytohormone gibberellin (GA) and its direct signal transducer DELLA. With this system, we screened inhibitors to the interaction. As a result, we discovered a chemical, 3-(2-thienylsulfonyl)pyrazine-2-carbonitrile (TSPC), and we confirmed that TSPC is an inhibitor for GA perception by in vitro and in planta evaluations.


Assuntos
Giberelinas/antagonistas & inibidores , Receptores de Superfície Celular/antagonistas & inibidores , Giberelinas/química , Giberelinas/metabolismo , Ensaios de Triagem em Larga Escala , Reguladores de Crescimento de Plantas/antagonistas & inibidores , Reguladores de Crescimento de Plantas/química , Reguladores de Crescimento de Plantas/metabolismo , Plantas Geneticamente Modificadas , Receptores de Superfície Celular/química , Receptores de Superfície Celular/metabolismo , Transdução de Sinais , Técnicas do Sistema de Duplo-Híbrido
11.
Biosens Bioelectron ; 220: 114912, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36413912

RESUMO

Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 µM in both the skin-mimicked gelatin phantom and porcine skin.


Assuntos
Técnicas Biossensoriais , Doença de Parkinson , Suínos , Animais , Levodopa , Agulhas , Líquido Extracelular
12.
ACS Appl Mater Interfaces ; 15(14): 17653-17663, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37010291

RESUMO

Atherosclerosis is one of the severe cardiovascular diseases in which blood vessels lose elasticity and the lumen narrows. If atherosclerosis worsens, it commonly leads to acute coronary syndrome (ACS) due to the rupture of vulnerable plaque or aortic aneurysm. As the mechanical properties of vascular tissues vary from their conditions, measuring the vascular stiffness of an inner blood vessel wall may be applied to the accurate diagnosis of atherosclerotic symptoms. Therefore, early mechanical detection of vascular stiffness is highly needed for immediate medical attention for ACS. Even with conventional examination methods such as intravascular ultrasonography and optical coherence tomography, several limitations still remain that make it difficult to directly determine the mechanical properties of the vascular tissue. As piezoelectric materials convert mechanical energy to electricity without an external power source, a piezoelectric nanocomposite could be utilized as a balloon catheter-integrated mechanical sensor on its surface. Here, we present piezoelectric nanocomposite micropyramid balloon catheter (p-MPB) arrays for measuring vascular stiffness. We study the structural characterization and feasibility of p-MPB as endovascular sensors by conducting finite element method analyses. Also, multifaceted piezoelectric voltages are measured by compression/release tests, in vitro vascular phantom tests, and ex vivo porcine heart tests to confirm that the p-MPB sensor properly operates in blood vessels.


Assuntos
Aterosclerose , Placa Aterosclerótica , Rigidez Vascular , Animais , Suínos , Ultrassonografia de Intervenção/métodos , Cateteres Urinários
13.
ACS Appl Mater Interfaces ; 15(39): 46513-46519, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37729007

RESUMO

The realization of next-generation gate-all-around field-effect transistors (FETs) using two-dimensional transition metal dichalcogenide (TMDC) semiconductors necessitates the exploration of a three-dimensional (3D) and damage-free surface treatment method to achieve uniform atomic layer-deposition (ALD) of a high-k dielectric film on the inert surface of a TMDC channel. This study developed a BCl3 plasma-derived radical treatment for MoS2 to functionalize MoS2 surfaces for the subsequent ALD of an ultrathin Al2O3 film. Microstructural verification demonstrated a complete coverage of an approximately 2 nm-thick Al2O3 film on a planar MoS2 surface, and the applicability of the technique to 3D structures was confirmed using a suspended MoS2 channel floating from the substrate. Density functional theory calculations supported by optical emission spectroscopy and X-ray photoelectron spectroscopy measurements revealed that BCl radicals, predominantly generated by the BCl3 plasma, adsorbed on MoS2 and facilitated the uniform nucleation of ultrathin ALD-Al2O3 films. Raman and photoluminescence measurements of monolayer MoS2 and electrical measurements of a bottom-gated FET confirmed negligible damage caused by the BCl3 plasma-derived radical treatment. Finally, the successful operation of a top-gated FET with an ultrathin ALD-Al2O3 (∼5 nm) gate dielectric film was demonstrated, indicating the effectiveness of the pretreatment.

14.
Bioinformatics ; 27(13): 1798-805, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21561922

RESUMO

MOTIVATION: Capillary electrophoresis (CE) of nucleic acids is a workhorse technology underlying high-throughput genome analysis and large-scale chemical mapping for nucleic acid structural inference. Despite the wide availability of CE-based instruments, there remain challenges in leveraging their full power for quantitative analysis of RNA and DNA structure, thermodynamics and kinetics. In particular, the slow rate and poor automation of available analysis tools have bottlenecked a new generation of studies involving hundreds of CE profiles per experiment. RESULTS: We propose a computational method called high-throughput robust analysis for capillary electrophoresis (HiTRACE) to automate the key tasks in large-scale nucleic acid CE analysis, including the profile alignment that has heretofore been a rate-limiting step in the highest throughput experiments. We illustrate the application of HiTRACE on 13 datasets representing 4 different RNAs, 3 chemical modification strategies and up to 480 single mutant variants; the largest datasets each include 87 360 bands. By applying a series of robust dynamic programming algorithms, HiTRACE outperforms prior tools in terms of alignment and fitting quality, as assessed by measures including the correlation between quantified band intensities between replicate datasets. Furthermore, while the smallest of these datasets required 7-10 h of manual intervention using prior approaches, HiTRACE quantitation of even the largest datasets herein was achieved in 3-12 min. The HiTRACE method, therefore, resolves a critical barrier to the efficient and accurate analysis of nucleic acid structure in experiments involving tens of thousands of electrophoretic bands.


Assuntos
Algoritmos , Eletroforese Capilar/métodos , Ácidos Nucleicos/química , Conformação de Ácido Nucleico , Análise de Sequência de DNA , Análise de Sequência de RNA
15.
Arch Virol ; 157(3): 497-501, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22160653

RESUMO

Some viruses have been reported to transcribe microRNAs, implying complex relationships between the host and the pathogen at the post-transcriptional level through microRNAs in virus-infected cells. Although many computational algorithms have been developed for microRNA target prediction, few have been designed exclusively to find cellular or viral mRNA targets of viral microRNAs in a user-friendly manner. To address this, we introduce the viral microRNA host target (vHoT) database for predicting interspecies interactions between viral microRNA and host genomes. vHoT supports target prediction of 271 viral microRNAs from human, mouse, rat, rhesus monkey, cow, and virus genomes. vHoT is freely available at http://dna.korea.ac.kr/vhot.


Assuntos
Bases de Dados Genéticas , Interações Hospedeiro-Patógeno , MicroRNAs/genética , RNA Mensageiro/genética , RNA Viral/genética , Vírus/genética , Vírus/patogenicidade , Animais , Regulação da Expressão Gênica , Humanos , MicroRNAs/metabolismo , RNA Mensageiro/metabolismo , RNA Viral/metabolismo
16.
Expert Opin Drug Deliv ; 19(9): 1115-1131, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36062366

RESUMO

INTRODUCTION: Microneedles (MNs) have undergone great advances in transdermal drug delivery, and commercialized MN applications are currently available in vaccination and cosmetic products. Despite the development of MN technologies, common limitations of MN products still exist. Typical MN patches are applied to target tissues, where the substrate of an MN patch must remain until the drug is delivered, which reduces patients' compliance and hinders the applicability of the MN technique to many diseases in various tissues. MN research is ongoing to solve this issue. AREAS COVERED: Most recent MNs developed by combining various biomaterials with appropriate fabrication processes are detachable MNs (DeMNs). Because of advances in biomaterials and fabrication techniques, various DeMNs have been rapidly developed. In this review, we discuss four types of DeMN: substrate-separable, multi-layered, crack-inducing, and shell DeMN. These DeMNs deliver various therapeutic agents ranging from small- and large-molecular-weight drugs to proteins and even stem cells for regeneration therapy. Furthermore, DeMNs are applied to skin as well as non-transdermal tissues. EXPERT OPINION: It has become increasingly evident that novel MN technologies can be expected in terms of designs, fabrication methods, materials, and even possible application sites given the recent advances in DeMNs.


Assuntos
Sistemas de Liberação de Medicamentos , Agulhas , Administração Cutânea , Materiais Biocompatíveis , Sistemas de Liberação de Medicamentos/métodos , Humanos , Microinjeções , Preparações Farmacêuticas
17.
Adv Healthc Mater ; 11(12): e2102599, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35192734

RESUMO

Intravitreal injection (IVI) is a common technology which is used to treat ophthalmic diseases inside eyeballs by delivering various drugs into the vitreous cavity using hypodermic needles. However, in some cases, there are possible side effects such as ocular tissue damage due to repeated injection or eyeball infection through the hole created during the needle retraction process. The best scenario of IVI is a one-time injection of drugs without needle retraction, keeping the system of the eyeball closed. Microneedles (MNs) have been applied to ocular tissues over 10 years, and no serious side effects on ocular tissue due to MN injection have been reported. Therefore, a self-plugging MN (SPM) is developed to perform intraocular drug delivery and to seal the scleral puncture simultaneously. The SPMs are fabricated by a thermal drawing process and then coated with a polymeric carrier of drugs and a hydrogel-based scleral plugging component. Each coated functional layer is characterized and demonstrated by in vitro and ex vivo experiments. Finally, in vivo tests using a porcine model confirms prompt sealing of SPM and sustained intraocular drug delivery.


Assuntos
Sistemas de Liberação de Medicamentos , Agulhas , Administração Cutânea , Animais , Excipientes , Olho , Hidrogéis/farmacologia , Microinjeções , Suínos
18.
Saf Health Work ; 12(2): 238-243, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34178402

RESUMO

OBJECTIVES: The aim of this study was to provide baseline data for the assessment of exposure to indium and to prevent adverse health effects among workers engaged in the electronics and related industries in Republic of Korea. METHODS: Total (n = 369) and respirable (n = 384) indium concentrations were monitored using personal air sampling in workers at the following 19 workplaces: six sputtering target manufacturing companies, four manufacturing companies of panel displays, two companies engaged in cleaning of sputtering components, two companies dedicated to the cleaning of sputtering target, and five indium recycling companies. RESULTS: The level of exposure to total indium ranged from 0.9 to 609.3 µg/m3 for the sputtering target companies; from 0.2 to 2,782.0 µg/m3 for the panel display companies and from 0.5 to 2,089.9 µg/m3 for the indium recycling companies. The level of exposure to respirable indium was in the range of 0.02 to 448.6 µg/m3 for the sputtering target companies; 0.01 to 419.5 µg/m3 for the panel display companies; and 0.5 to 436.3 µg/m3 for the indium recycling companies. The indium recycling companies had the most samples exceeding the exposure standard for indium, followed by sputtering target companies and panel display companies. CONCLUSIONS: The main finding from this exposure assessment is that many workers who handle indium compounds in the electronics industry are exposed to indium levels that exceed the exposure standards for indium. Hence, it is necessary to continuously monitor the indium exposure of this workforce and take measures to reduce its exposure levels.

19.
Korean J Intern Med ; 36(5): 1242-1250, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34503320

RESUMO

BACKGROUND/AIMS: We aimed to assess the validity of the Korean translated version of the Clinical Frailty Scale (CFS) in determining the frailty status in geriatric outpatients. METHODS: The records of 123 ambulatory outpatients who had undergone CFS and comprehensive geriatric assessments (CGAs) including measurements for the Cardiovascular Health Study (CHS) frailty scale and the frailty index (CGA-FI) were analyzed. Correlations between CFS, CHS frailty scale, and CGA-FI were assessed. The ability of CFS to classify frailty status was calculated using the CHS frailty scale and CGA-FI as references. RESULTS: The mean CFS score was 3.2 in the study population, with a mean age of 77.49 years (45.5% men). Individuals with higher CFS scores were older, had a greater burden of chronic diseases, and worse daily functions and cognitive performance. CFS scores positively correlated with CGA-FI (B = 0.78, p < 0.001) and CHS frailty scale (B = 0.67, p < 0.001) scores. For CFS, C-statistics to classify frailty by CGA-FI and CHS scale were 0.905 and 0.826, respectively. The cut-off value of CFS ≥ 4 maximized Youden's J to classify frailty by both the CHS scale and CGAFI. CONCLUSION: The CFS is a valid screening tool to assess the frailty status in outpatients of a geriatric clinic in Korea. As a simple and quick measure, the CFS may facilitate frailty assessments in real-world clinical practice.


Assuntos
Fragilidade , Idoso , Instituições de Assistência Ambulatorial , Feminino , Idoso Fragilizado , Fragilidade/diagnóstico , Avaliação Geriátrica , Humanos , Masculino , República da Coreia
20.
Adv Healthc Mater ; 10(11): e2002287, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33930253

RESUMO

Infectious keratitis is mainly treated with topical antibiotics. To achieve and maintain the required therapeutic concentration in the cornea where the tear fluid continuously rinses the surface, the antibiotics must be frequently applied, even while the patient is sleeping, and oral medication is sometimes required. However, the inevitably poor compliance and avascular nature of the cornea decrease drug bioavailability. In this study, a single microneedle (MN) is injected into the cornea to substitute for the repeated application of eyedrops in the treatment of infectious keratitis. After comparing the mechanical integrity and drug release profiles of three different drug-tips, the drug-tip with the "high" drug concentration that releases 12.5 ng drug within 3 days is applied to a cornea to evaluate the transferability and in vivo drug release. In the treatment of infectious keratitis with repeated application of eyedrops for six consecutive days, a single MN injection is substituted for the initial 3 days of eyedrop applications. The progression remains similarly attenuated after 3 days without eyedrops, and comparable efficacy is achieved on day 6 when combined with delayed eyedrop treatment from day 3. Thus, the single administration of a biodegradable MN can substitute for the repeated application of eyedrops in the treatment of infectious keratitis.


Assuntos
Ceratite , Administração Tópica , Córnea , Humanos , Ceratite/tratamento farmacológico , Agulhas , Soluções Oftálmicas/uso terapêutico , Lágrimas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA