Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-17141561

RESUMO

Acrolein and 1,3-butadiene in cigarette smoke generally are measured using two separate analytical methods, a carbonyl derivative HPLC method for acrolein and a volatile organic compound (VOC) GC/MS method for 1,3-butadiene. However, a single analytical method having improved sensitivity and real-time per puff measurement will offer more specific information for evaluating experimental carbon filtered cigarettes designed to reduce the smoke deliveries of these constituents. This paper describes an infrared technique using two lead-salt tunable diode lasers (TDLs) operating with liquid nitrogen cooling with emissions at 958.8 cm(-1) and 891.0 cm(-1) respectively for the simultaneous measurement of acrolein and 1,3-butadiene, respectively, in each puff of mainstream cigarette smoke in real time. The dual TDL system uses a 3.1l volume, 100 m astigmatic multiple pass absorption gas cell. Quantitation is based on a spectral fit that uses previously determined infrared molecular line parameters generated in our laboratory, including line positions, line strengths and nitrogen-broadened half-widths for these species. Since acrolein and ethylene absorption lines overlap and 1,3-butadiene, ethylene and propylene absorption lines overlap, the per puff deliveries of ethylene and propylene were determined since their overlapping absorption lines must be taken into account by the spectral fit. The acrolein and 1,3-butadiene total cigarette deliveries for the 1R5F Kentucky Reference cigarette were in agreement with the HPLC and GC/MS methods, respectively. The limit of detection (LOD) for 1,3-butadiene and acrolein was 4 ng/puff and 24 ng/puff, respectively, which is more than adequate to determine at which puff they break through the carbon filter. The retention and breakthrough behavior for the two primary smoke constituents depend on the cigarette design and characteristics of the carbon filter being evaluated.


Assuntos
Acroleína/análise , Butadienos/análise , Fumaça/análise , Fumar , Humanos , Lasers , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-17142096

RESUMO

The objective of this research was to apply Fourier transform infrared spectroscopy (FTIR) and tunable infrared laser differential absorption spectroscopy (TILDAS) for measuring selected gaseous constituents in mainstream (MS) and sidestream (SS) smoke for experimental cigarettes designed to reduce MS CO using iron oxide cigarette papers. These two complimentary analytical techniques are well suited for providing per puff smoke deliveries and intra-puff evolution profiles in cigarette smoke respectively. The quad quantum cascade (QC) laser high resolution infrared spectroscopy system has the necessary temporal and spectral resolution and whole smoke analysis capabilities to provide detailed information for CO and CO(2) as they are being formed in both MS and SS smoke. The QC laser system has an optimal data rate of 20 Hz and a unique puffing system, with a square wave shaped puff, that allows whole smoke to enter an 18 m, 0.3 L multi-pass gas cell in real time (0.1s cell response time) requiring no syringe or Cambridge filter pad. Another similar multi-pass gas cell with a 36 m pathlength simultaneously monitors the sidestream cigarette smoke. The smoke from experimental cigarettes manufactured with two types of iron oxide papers were compared to the smoke from cigarettes manufactured similarly without iron oxide in the paper using both instrument systems. The delivery per puff determined by the QC laser method agreed with FTIR results. MS CO intra-puff evolution profiles for iron oxide prototype cigarettes demonstrated CO reduction when compared to cigarettes without iron oxide paper. Additionally, both CO and CO(2) intra-puff evolution profiles of the cigarettes with iron oxide paper showed a significant reduction at the initial portion of the 2 s puff not observed in the non-iron oxide prototype cigarettes. This effect also was observed for ammonia and ethylene, suggesting that physical parameters such as paper porosity and burn rate are important. The SS CO and CO(2) deliveries for the experimental cigarettes evaluated remained unaffected. The iron oxide paper technology remains under development and continues to be evaluated.


Assuntos
Dióxido de Carbono/análise , Monóxido de Carbono/análise , Compostos Férricos , Papel , Fumar , Análise Espectral/métodos , Lasers , Teoria Quântica , Análise Espectral/instrumentação
3.
Artigo em Inglês | MEDLINE | ID: mdl-16500137

RESUMO

Acrolein (C(3)H(4)O) molecular line parameters, including infrared (IR) absorption positions, strengths, and nitrogen broadened half-widths, must be determined since they are not included in the high resolution transmission (HITRAN) molecular absorption database of spectral lines. These parameters are required for developing a quantitative analytical method for measuring acrolein in a single puff of cigarette smoke using tunable diode laser absorption spectroscopy (TDLAS). The task is complex since acrolein has many highly overlapping infrared absorption lines in the room temperature spectrum and the cigarette smoke matrix contains thousands of compounds. This work describes the procedure for estimating the molecular line parameters for these overlapping absorption lines in the wavenumber range (958.7-958.9 cm(-1)) using quantitative reference spectra taken with the infrared lead-salt TDLAS instrument at different pressures and concentrations. The nitrogen broadened half-width for acrolein is 0.0937 cm(-1)atm(-1) and to our knowledge, is the first time it has been reported in the literature.


Assuntos
Acroleína/análise , Lasers , Nicotiana/química , Fumaça/análise , Espectrofotometria Infravermelho , Etilenos/química , Humanos , Análise Espectral
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 63(5): 994-1001, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16490384

RESUMO

Although nitrogen dioxide (NO(2)) has been previously reported to be present in cigarette smoke, the concentration estimates were derived from kinetic calculations or from measurements of aged smoke, where NO(2) was formed some time after the puff was taken. The objective of this work was to use tunable infrared laser differential absorption spectroscopy (TILDAS) equipped with a quantum cascade (QC) laser to determine if NO(2) could be detected and quantified in a fresh puff of cigarette smoke. A temporal resolution of approximately 0.16s allowed measurements to be taken directly as the NO(2) was formed during the puff. Sidestream cigarette smoke was sampled to determine if NO(2) could be detected using TILDAS. Experiments were conducted using 2R4F Kentucky Reference cigarettes with and without a Cambridge filter pad. NO(2) was detected only in the lighting puff of whole mainstream smoke (without a Cambridge filter pad), with no NO(2) detected in the subsequent puffs. The measurement precision was approximately 1.0 ppbVHz(-1/2), which allows a detection limit of approximately 0.2 ng in a 35 ml puff volume. More NO(2) was generated in the lighting puff using a match or blue flame lighter (29+/-21 ng) than when using an electric lighter (9+/-3 ng). In the presence of a Cambridge filter pad, NO(2) was observed in the gas phase mainstream smoke for every puff (total of 200+/-30 ng/cigarette) and is most likely due to smoke chemistry taking place on the Cambridge filter pad during the smoke collection process. Nitrogen dioxide was observed continuously in the sidestream smoke starting with the lighting puff.


Assuntos
Técnicas de Química Analítica/instrumentação , Lasers , Nicotiana/química , Dióxido de Nitrogênio/análise , Fumaça/análise , Espectrofotometria Infravermelho , Técnicas de Química Analítica/métodos , Humanos , Teoria Quântica , Espectrofotometria Infravermelho/instrumentação , Espectrofotometria Infravermelho/métodos
5.
Spectrochim Acta A Mol Biomol Spectrosc ; 62(1-3): 226-32, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16257718

RESUMO

Endogenous metals present in tobacco from agricultural practices have been purported to generate metal carbonyls in cigarette smoke. Transition metal catalysts, such as iron oxide, have been investigated for the reduction of carbon monoxide (CO) in cigarette smoke. These studies motivated the development of an analytical method to determine if iron pentacarbonyl [Fe(CO)(5)] is present in mainstream smoke from cigarette models having cigarette paper made with iron oxide. An FT-IR puff-by-puff method was developed and the detection limit was determined using two primary reference spectra from different sources to estimate the amount of Fe(CO)(5) present in a high-pressure steel cylinder of CO. We do not detect Fe(CO)(5) in a single 35 mL puff from reference cigarettes or from those cigarette models having cigarette paper made with iron oxide, with a 30-ppbV limit of detection (LOD). Also, it was shown that a filter containing activated carbon would remove Fe(CO)(5).


Assuntos
Poluentes Atmosféricos/análise , Compostos Organometálicos/análise , Fumaça/análise , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Compostos Carbonílicos de Ferro , Sensibilidade e Especificidade , Fumar
6.
Spectrochim Acta A Mol Biomol Spectrosc ; 60(14): 3421-9, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15561628

RESUMO

A technique has been developed for the determination of molecular parameters, including infrared absorption line positions, strengths, and nitrogen-broadened half-widths for 1,3-butadiene (C(4)H(6)) and propylene (C(3)H(6)). The parameters for these two molecules are required for quantitation using Tunable Diode Laser Absorption Spectroscopy (TDLAS). These molecules have populations of highly overlapping infrared absorption lines in their room temperature spectra. The technique reported here provides a procedure for estimating the molecular parameters for these overlapping absorption lines from quantitative reference spectra taken with the TDLAS instrument at different pressures and concentrations. The system was developed for the quantitation of gaseous constituents in a single puff of cigarette smoke and this paper will describe the procedure and some of the factors that influence the accuracy of quantitation for 1,3-butadiene, including the approach taken to minimize the adverse effects of the absorption due to propylene in the same spectral region.


Assuntos
Alcenos/química , Butadienos/química , Lasers , Fumaça/análise , Espectrofotometria Infravermelho , Nicotiana/química
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 60(14): 3437-47, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15561630

RESUMO

A compact, fast response, infrared spectrometer using four pulsed quantum cascade (QC) lasers has been applied to the analysis of gases in mainstream (MS) and sidestream (SS) cigarette smoke. QC lasers have many advantages over the traditional lead-salt tunable diode lasers, including near room temperature operation with thermoelectric cooling and single mode operation with improved long-term stability. The new instrument uses two 36 m, 0.3 l multiple pass absorption gas cells to obtain a time response of 0.1s for the MS smoke system and 0.4s for the SS smoke system. The concentrations of ammonia, ethylene, nitric oxide, and carbon dioxide for three different reference cigarettes were measured simultaneously in MS and SS smoke. A data rate of 20Hz provides sufficient resolution to determine the concentration profiles during each 2s puff in the MS smoke. Concentration profiles before, during and after the puffs also have been observed for these smoke constituents in SS smoke. Also, simultaneous measurements of CO(2) from a non-dispersive infrared (NDIR) analyzer are obtained for both MS and SS smoke. In addition, during this work, nitrous oxide was detected in both the MS and SS smoke for all reference cigarettes studied.


Assuntos
Técnicas de Química Analítica/instrumentação , Nicotiana/química , Fumaça/análise , Amônia/análise , Dióxido de Carbono/análise , Técnicas de Química Analítica/métodos , Etilenos/análise , Lasers , Óxido Nítrico/análise , Óxido Nitroso/análise , Espectrofotometria Infravermelho/instrumentação , Espectrofotometria Infravermelho/métodos
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 58(11): 2505-17, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12353701

RESUMO

Infrared absorption lines of hydrazine are broad and typically not baseline resolved, with line strengths approximately 100 times weaker than the more widely studied compound ammonia. Hardware and software improvements have been made to a two-color infrared tunable diode laser (IR-TDL) spectrometer in order to improve the limit of detection (LOD) of hydrazine (N2H4) in the cigarette smoke matrix. The detection limit in the smoke matrix was improved from 25 parts-per-million-by-volume (ppmv) to 4.2 ppmv using a 100 m pathlength cell with acquisition of background spectra immediately prior to each sample and 100 ms temporal resolution. This study did not detect hydrazine in cigarette smoke in the 964.4-964.9 cm(-1) spectral region, after mathematically subtracting the spectral contributions of ethylene, ammonia, carbon dioxide, methanol, acrolein, and acetaldehyde. These compounds are found in cigarette smoke and absorb in this spectral region. The LOD is limited by remaining spectral structure from unidentified smoke species. The pseudo random noise (root mean square) in the improved instrument was 2 x 10(-4) absorbance units (base e) which is equivalent to a 0.09 ppmv hydrazine gas sample in the multipass cell. This would correspond to a detection limit of 0.44 ppmv of hydrazine, given the dilution of the smoke by a factor of 5 by the sampling system. This is a factor of 10 less than the 4.2 ppmv detection limit for hydrazine in the smoke matrix, and indicates that the detection limit is primarily a result of the complexity of the matrix rather than the random noise of the TDL instrument.


Assuntos
Hidrazinas/análise , Nicotiana/química , Fumaça/análise , Espectrofotometria Infravermelho/instrumentação , Espectrofotometria Infravermelho/métodos
9.
Anal Chem ; 74(22): 5871-81, 2002 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-12463375

RESUMO

Cellulose acetate (CA) filters have been investigated to determine their hydrazine (N2H4) breakthrough characteristics using a system based on tunable diode laser absorption spectroscopy (TDIAS). The breakthrough mass loading sorption curves for hydrazine were dependent on both the flow rate and the concentration. In experiments using a 4.5 ppmv hydrazine standard, the amounts of hydrazine retained by the CA filter were 4.25 microg at a flow rate of 2.82 L/min and 65 microg at a flow rate of 0.28 L/min. These loadings are much greater than the 31.5 ng/cigarette of hydrazine reported in smoke for unfiltered cigarettes. Further, CA filters exposed to four and eight puffs of smoke actually made the filter more efficient in retaining hydrazine compared to CA filters that had not been exposed to smoke. Therefore, if hydrazine is present in smoke at the levels reported in unfiltered cigarettes, all of the hydrazine would be trapped by the CA filter, and would be unable to break through during smoking. A unique feature of this analytical method is that the instrument does not require calibration after molecular parameters have been determined, in this case from previously acquired quantitative hydrazine FT-IR reference spectra.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA