Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Acta Radiol ; 64(10): 2812-2819, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37545176

RESUMO

BACKGROUND: A higher incidence of late adverse events (LAEs) to iodinated contrast media in interleukin-2 (IL-2)-treated patients has been reported. PURPOSE: To assess the incidence of LAEs after administration of iodinated contrast media in patients with metastatic renal cell carcinoma (mRCC) treated with IL-2. MATERIAL AND METHODS: Patients were randomized to treatment with IL-2 and interferon-α with/without bevacizumab in the Danish Renal Carcinoma Group study - 1. Patients underwent a computed tomography (CT) scan at baseline, at one month, at three months, and every third month until RECIST 1.1 defined progression. LAEs due to iodinated contrast media were systematically registered according to the Common Terminology Criteria for Adverse Events classification. RESULTS: In total, 89 patients were included and underwent a total of 507 contrast-enhanced CT scans. An overall incidence of 46 (9.1%) LAEs was observed in 38 of 89 (42.7%) patients; 3 LAEs at baseline (3.4% of all baseline scans), 39 (13.9%) LAEs during IL-2-based therapies, and 4 (2.9%) LAEs after termination of IL-based therapies. There was no difference in progression-free survival, overall survival, and treatment response in patients experiencing LAEs compared to patients without LAEs (P = 0.2, P = 0.5, and P = 0.6, respectively). CONCLUSION: Patients with mRCC demonstrated a higher incidence of LAEs after administration of iodinated contrast during ongoing IL-2 therapy, indicating that iodinated contrast media may cause a recall phenomenon of IL-2 toxicities in patients with mRCC. Treatment with IL-2 should not be a contraindication for contrast-enhanced scans in patients with mRCC but expertise and vigilance are required.

2.
J Magn Reson Imaging ; 51(3): 904-911, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31313407

RESUMO

CONTRACT GRANT SPONSOR: Health Research Fund of Central Denmark Region. BACKGROUND: Diffusion gradient nonlinearity (DGNL) bias causes apparent diffusion coefficient (ADC) values to drop with increasing superior-inferior (SI) isocenter offset. This is a concern when performing quantitative diffusion-weighted imaging (DWI). PURPOSE/HYPOTHESIS: To investigate if DGNL ADC bias can be corrected in breast cancer bone metastases using a clinical DWI protocol and an online correction algorithm. STUDY TYPE: Prospective. SUBJECTS/PHANTOM: A diffusion phantom (Model 128, High Precision Devices, Boulder, CO) was used for in vitro validation. Twenty-three women with bone-metastasizing breast cancer were enrolled to assess DGNL correction in vivo. FIELD STRENGTH/SEQUENCE: DWI was performed on a 1.5T MRI system as single-shot, spin-echo, echo-planar imaging with short-tau inversion recovery (STIR) fat-saturation. ADC maps with and without DGNL correction were created from the b50 and b800 images. ASSESSMENT: Uncorrected and DGNL-corrected ADC values were measured in phantom and bone metastases by placing regions of interest on b800 images and copying them to the ADC map. The SI offset was recorded. STATISTICAL TESTS: In all, 79 bone metastases were assessed. ADC values with and without DGNL correction were compared at 14 cm SI offset using a two-tailed t-test. RESULTS: In the diffusion phantom, DGNL correction increased SI offset, where ADC bias was lower than 5%, from 7.3-13.8 cm. Of the 23 patients examined, six had no metastases in the covered regions. In the remaining patients, bias of uncorrected bone metastasis ADC values was 19.1% (95% confidence interval [CI]: 15.4-22.9%) at 14 cm SI offset. After DGNL correction, ADC bias was significantly reduced to 3.5% (95% CI: 0.7-6.3%, P < 0.001), thus reducing bias due to DGNL by 82%. DATA CONCLUSION: Online DGNL correction corrects DGNL ADC value bias and allows increased station lengths in the SI direction. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:904-911.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Estudos Prospectivos , Reprodutibilidade dos Testes
3.
Acta Anaesthesiol Scand ; 64(3): 368-377, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31650529

RESUMO

BACKGROUND: A femoral nerve block relieves pain after total hip arthroplasty, but its use is controversial due to motor paralysis accompanied by an increased risk of fall. Assumedly, the iliopsoas plane block (IPB) targets the hip articular branches of the femoral nerve without motor blockade. However, this has only been indicated in a cadaver study. Therefore, we designed this volunteer study. METHODS: Twenty healthy volunteers were randomly allocated to blinded paired active vs. sham IPB (5 mL lidocaine 18 mg/mL with epinephrine vs saline). The primary outcome was reduction of maximal force of knee extension after IPB compared to baseline. Secondary outcomes included reduction of maximal force of hip adduction, and the pattern of injectate spread assessed with magnetic resonance imaging. RESULTS: Mean (confidence interval) change of maximal force of knee extension from baseline to after IPB was -9.7 N (-22, 3.0) (P = .12) (n = 14). The injectate was consistently observed in an anatomically well-defined closed fascial compartment between the intra- and extra-pelvic components of the iliopsoas muscle anterior to the hip joint. CONCLUSION: We observed no significant reduction of maximal force of knee extension after an IPB. The injectate was contained in a fascial compartment previously shown to contain all sensory branches from the femoral nerve to the hip joint. The clinical consequence of selective anesthesia of all sensory femoral nerve branches from the hip could be a reduced risk of fall compared to a traditional femoral nerve block. Registration of Trial: The trial was prospectively registered in EudraCT (Reference: 2018-000089-12, https://www.clinicaltrialsregister.eu/ctr-search/search?query=2018-000089-12).


Assuntos
Anestésicos Locais/administração & dosagem , Nervo Femoral/efeitos dos fármacos , Lidocaína/administração & dosagem , Bloqueio Nervoso/métodos , Paresia/prevenção & controle , Adulto , Método Duplo-Cego , Epinefrina/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Psoas , Valores de Referência , Solução Salina/administração & dosagem , Adulto Jovem
4.
Eur Radiol ; 29(3): 1221-1230, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30132104

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of 68gallium prostate-specific membrane antigen (PSMA)-based positron emission tomography/computed tomography (PET/CT) in comparison with 18F-fluoride-based PET/CT (NaF-PET/CT) and whole-body magnetic resonance imaging (WB-MRI) for the detection of bone metastases in patients with prostate cancer. METHODS: Sixty patients with prostate cancer were included in the period May 2016 to June 2017. The participants underwent three scans (index tests) within 30 days: a NaF-PET/CT, a WB-MRI and a PSMA-PET/CT. Experienced specialists assessed the scans. In the absence of a histological reference standard, the final diagnosis was determined as a panel diagnosis. Measures of the diagnostic performances of the index tests were calculated from patient-based dichotomous outcomes (0 or ≥ 1 bone metastasis) and pairwise compared (McNemar test). For each index test, the agreement with the final diagnosis with regard to the number of bone metastases detected (0, 1-5, > 5) and the inter-reader agreement was calculated (kappa coefficients). RESULTS: Fifty-five patients constituted the final study population; 20 patients (36%) were classified as having bone metastatic disease as their final diagnosis. The patient-based diagnostic performances were (sensitivity, specificity, overall accuracy) PSMA-PET/CT (100%, 100%, 100%), NaF-PET/CT (95%, 97%, 96%) and WB-MRI (80%, 83%, 82%). The overall accuracy of PSMA-PET/CT was significantly more favourable compared to WB-MRI (p = 0.004), but not to NaF-PET/CT (p = 0.48). PSMA-PET/CT classified the number of bone metastases reliably compared to the final diagnosis (kappa coefficient 0.97) and with an "almost perfect" inter-reader agreement (kappa coefficient 0.93). CONCLUSIONS: The overall accuracy of PSMA-PET/CT was significantly more advantageous compared to WB-MRI, but not to NaF-PET/CT. KEY POINTS: • PSMA-PET/CT assessed the presence of bone metastases correctly in all 55 patients • PSMA-PET/CT was more advantageous compared to WB-MRI • No difference was found between PSMA-PET/CT and NaF-PET/CT.


Assuntos
Antígenos de Superfície/farmacologia , Neoplasias Ósseas/secundário , Radioisótopos de Gálio/farmacologia , Glutamato Carboxipeptidase II/farmacologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/patologia , Imagem Corporal Total/métodos , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
Acta Oncol ; 54(9): 1461-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26313410

RESUMO

BACKGROUND: The bladder is a tumour site well suited for adaptive radiotherapy (ART) due to large inter-fractional changes, but it also displays considerable intra-fractional motion. The aim of this study was to assess target coverage with a clinically applied method for plan selection ART and to estimate population-based and patient-specific intra-fractional margins, also relevant for a future re-optimisation strategy. MATERIAL AND METHODS: Nine patients treated in a clinical phase II ART trial of daily plan selection for bladder cancer were included. In the library plans, 5 mm isotropic margins were added to account for intra-fractional changes. Pre-treatment and weekly repeat magnetic resonance imaging (MRI) series were acquired in which a full three-dimensional (3D) volume was scanned every second min for 10 min (a total of 366 scans in 61 series). Initially, the bladder clinical target volume (CTV) was delineated in all scans. The t = 0 min scan was then rigidly registered to the planning computed tomography (CT) and plan selections were simulated using the CTV_0 (at t = 0 min). To assess intra-fractional motion, coverage of the CTV_10 (at t = 10 min) was quantified using the applied PTV. Population-based margins were calculated using the van Herk margin recipe while patient-specific margins were calculated using a linear model. RESULTS: For 49% of the cases, the CTV_10 extended more than 5 mm outside the CTV_0. However, in 58 of the 61 cases (97%) CTV_10 was covered by the selected PTV. Population-based margins of 14 mm Sup/Ant, 9 mm Post and 5 mm Inf/Lat were sufficient to cover the bladder. Using patient-specific margins, the overlap between PTV and bowel-cavity was reduced from 137 cm(3) with the plan selection strategy to 24 cm(3). CONCLUSION: In this phase II ART trial, 5 mm isotropic margin for intra-fractional motion was sufficient even though considerable intra-fractional motion was observed. In online re-optimised ART, population-based margin can be applied although patient-specific margins are preferable.


Assuntos
Imageamento por Ressonância Magnética , Movimento , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/radioterapia , Humanos , Imageamento Tridimensional , Radioterapia Guiada por Imagem
7.
Acta Oncol ; 53(8): 1073-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25017378

RESUMO

BACKGROUND: Geometrical distortion is a major obstacle for the use of echo planar diffusion-weighted magnetic resonance imaging (DW-MRI) in planning of radiotherapy. This study compares geometrical distortion correction methods of DW-MRI at time of brachytherapy (BT) in locally advanced cervical cancer patients. MATERIAL AND METHODS: In total 21 examinations comprising DW-MRI, dual gradient echo (GRE) for B0 field map calculation and T2-weighted (T2W) fat-saturated MRI of eight patients with locally advanced cervical cancer were acquired during BT with a plastic tandem and ring applicator in situ. The ability of B0 field map correction (B0M) and deformable image registration (DIR) to correct DW-MRI geometric image distortion was compared to the non-corrected DW-MRI including evaluation of apparent diffusion coefficient (ADC) for the gross tumor volume (GTV). RESULTS: Geometrical distortion correction decreased tandem displacement from 3.3 ± 0.9 mm (non-corrected) to 2.9 ± 1.0 mm (B0M) and 1.9 ± 0.6 mm (DIR), increased mean normalized cross-correlation from 0.69 ± 0.1 (non- corrected) to 0.70 ± 0.10 (B0M) and 0.77 ± 0.1 (DIR), and increased the Jaccard similarity coefficient from 0.72 ± 0.1 (non-corrected) to 0.73 ± 0.06 (B0M) and 0.77 ± 0.1 (DIR). For all parameters only DIR corrections were significant (p < 0.05). ADC of the GTV did not change significantly with either correction method. CONCLUSION: DIR significantly improved geometrical accuracy of DW-MRI, with remaining residual uncertainties of less than 2 mm, while no significant improvement was seen using B0 field map correction.


Assuntos
Braquiterapia/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Colo do Útero/radioterapia , Braquiterapia/instrumentação , Campos Eletromagnéticos , Feminino , Humanos , Reprodutibilidade dos Testes , Neoplasias do Colo do Útero/patologia
8.
J Cardiovasc Magn Reson ; 13: 24, 2011 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-21527014

RESUMO

BACKGROUND: The risk of aortic dissection is 100-fold increased in Turner syndrome (TS). Unfortunately, risk stratification is inadequate due to a lack of insight into the natural course of the syndrome-associated aortopathy. Therefore, this study aimed to prospectively assess aortic dimensions in TS. METHODS: Eighty adult TS patients were examined twice with a mean follow-up of 2.4 ± 0.4 years, and 67 healthy age and gender-matched controls were examined once. Aortic dimensions were measured at nine predefined positions using 3D, non-contrast and free-breathing cardiovascular magnetic resonance. Transthoracic echocardiography and 24-hour ambulatory blood pressure were also performed. RESULTS: At baseline, aortic diameters (body surface area indexed) were larger at all positions in TS. Aortic dilation was more prevalent at all positions excluding the distal transverse aortic arch. Aortic diameter increased in the aortic sinus, at the sinotubular junction and in the mid-ascending aorta with growth rates of 0.1 - 0.4 mm/year. Aortic diameters at all other positions were unchanged. The bicuspid aortic valve conferred higher aortic sinus growth rates (p < 0.05). No other predictors of aortic growth were identified. CONCLUSION: A general aortopathy is present in TS with enlargement of the ascending aorta, which is accelerated in the presence of a bicuspid aortic valve.


Assuntos
Aorta/patologia , Aneurisma Aórtico/diagnóstico , Imageamento por Ressonância Magnética , Síndrome de Turner/complicações , Adolescente , Adulto , Aneurisma Aórtico/etiologia , Aneurisma Aórtico/patologia , Valva Aórtica/anormalidades , Pressão Sanguínea , Monitorização Ambulatorial da Pressão Arterial , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Dinamarca , Dilatação Patológica , Progressão da Doença , Ecocardiografia , Feminino , Cardiopatias Congênitas/complicações , Frequência Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Lineares , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Adulto Jovem
9.
J Cardiovasc Magn Reson ; 12: 12, 2010 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-20222980

RESUMO

BACKGROUND: To investigate aortic dimensions in women with Turner syndrome (TS) in relation to aortic valve morphology, blood pressure, karyotype, and clinical characteristics. METHODS AND RESULTS: A cross sectional study of 102 women with TS (mean age 37.7; 18-62 years) examined by cardiovascular magnetic resonance (CMR- successful in 95), echocardiography, and 24-hour ambulatory blood pressure. Aortic diameters were measured by CMR at 8 positions along the thoracic aorta. Twenty-four healthy females were recruited as controls. In TS, aortic dilatation was present at one or more positions in 22 (23%). Aortic diameter in women with TS and bicuspid aortic valve was significantly larger than in TS with tricuspid valves in both the ascending (32.4 +/- 6.7 vs. 26.0 +/- 4.4 mm; p < 0.001) and descending (21.4 +/- 3.5 vs. 18.8 +/- 2.4 mm; p < 0.001) aorta. Aortic diameter correlated to age (R = 0.2 - 0.5; p < 0.01), blood pressure (R = 0.4; p < 0.05), a history of coarctation (R = 0.3; p = 0.01) and bicuspid aortic valve (R = 0.2-0.5; p < 0.05). Body surface area only correlated with descending aortic diameter (R = 0.23; p = 0.024). CONCLUSIONS: Aortic dilatation was present in 23% of adult TS women, where aortic valve morphology, age and blood pressure were major determinants of the aortic diameter.


Assuntos
Aorta Torácica/patologia , Doenças da Aorta/diagnóstico , Valva Aórtica/anormalidades , Pressão Sanguínea , Cardiopatias Congênitas/complicações , Imageamento por Ressonância Magnética , Síndrome de Turner/complicações , Adolescente , Adulto , Fatores Etários , Aorta Torácica/fisiopatologia , Coartação Aórtica/complicações , Doenças da Aorta/etiologia , Doenças da Aorta/fisiopatologia , Valva Aórtica/fisiopatologia , Monitorização Ambulatorial da Pressão Arterial , Superfície Corporal , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Estudos Transversais , Dilatação Patológica , Ecocardiografia , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Modelos Lineares , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Síndrome de Turner/fisiopatologia , Adulto Jovem
10.
Radiother Oncol ; 145: 117-124, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31931290

RESUMO

INTRODUCTION: Research in radiation-induced urinary morbidity is limited by lack of guidelines for contouring and dose assessment of the lower urinary tract. Based on literature regarding anatomy, physiology and imaging of the lower urinary tract, this study aimed to provide advice on contouring of relevant sub-structures, reference points and reference dimensions for gynaecological radiotherapy. MATERIAL AND METHODS: 210 MRIs for Image-Guided Adaptive Brachytherapy (IGABT) were analysed in 105 locally advanced cervical cancer patients treated with radio(chemo)therapy. Sub-structures (trigone, bladder neck and urethra) were contoured and trigone height (TH) and width (TW) were measured. Internal urethral ostium (IUO) and Posterior inferior border of pubic symphysis-urethra (PIBS-U) points were used to identify proximal and middle/low urethra, respectively. Urethra reference length (URL) was defined as IUO and PIBS-U distance. TH, TW and URL were also quantified on 54 MRIs acquired for External Beam Radiotherapy (EBRT). RESULTS: Median absolute differences in volumes and dimensions between first and second IGABT fraction were 0.7 cm3, 4.3 cm3, 0.2 cm, 0.3 cm and 0.2 cm for trigone, bladder neck, TH, TW and URL, respectively. Mean(±SD) TH and TW were 2.7(±0.4)cm and 4.4(±0.4)cm, respectively, with no significant difference (p = 0.15 and p = 0.06, respectively) between IGABT and EBRT. URL was significantly shorter in EBRT than in IGABT MRIs (p < 0.001). CONCLUSIONS: This study proposed relevant urinary sub-structures and dose points and showed that standardized contouring is reproducible. Trigone reference dimensions are robust despite different bladder filling and treatment conditions. Standardized contouring and reference points may improve understanding of urinary morbidity.


Assuntos
Braquiterapia , Radioterapia Guiada por Imagem , Sistema Urinário , Neoplasias do Colo do Útero , Feminino , Humanos , Imageamento por Ressonância Magnética , Dosagem Radioterapêutica , Bexiga Urinária/diagnóstico por imagem , Sistema Urinário/diagnóstico por imagem , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia
11.
Radiology ; 246(1): 249-57, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17951351

RESUMO

The study was approved by the local ethical committees, and informed consent from each participant was obtained. The purpose of the study was to compare accelerated magnetic resonance (MR) Fourier velocity encoding (FVE), MR phase-contrast velocity mapping, and echocardiography with respect to peak velocity determination in vascular or valvular stenoses. FVE data collection was accelerated by using the k-space and time sensitivity encoding, or k-t SENSE, technique. Peak velocities were evaluated in five healthy volunteers (one woman, four men; mean age, 28 years; range, 23-34 years), three patients with stenotic aortic valves (two women, one man; mean age, 67 years; range, 39-82 years), two patients with pulmonary valvular stenosis (a 14-year-old girl and a 36-year-old man), and two patients with aortic stenosis (two women aged 18 and 27 years). In volunteers, peak velocity determined by the different methods agreed well. In patients, similar peak velocities were obtained by using accelerated MR FVE and echocardiography, while phase-contrast MR imaging results tended to underestimate these values.


Assuntos
Aorta Torácica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Imageamento por Ressonância Magnética , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Arteriopatias Oclusivas/diagnóstico , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Pulmonar/diagnóstico , Ultrassonografia
12.
Brachytherapy ; 17(1): 50-58, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28935450

RESUMO

PURPOSE: To quantify needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer and propose a threshold for needle migration. METHODS AND MATERIALS: Twenty-four high-risk prostate cancer patients treated with an HDR boost of 2 × 8.5 Gy were included. Patients received an MRI for planning (MRI1), before (MRI2), and after treatment (MRI3). Time from needle insertion to MRI3 was ∼3 hours. Needle migration was evaluated from coregistered images: MRI1-MRI2 and MRI1-MRI3. Dose volume histogram parameters from the treatment plan based on MRI1 were related to parameters based on needle positions in MRI2 or MRI3. Regression was used to model the average needle migration per implant and change in D90 clinical target volume, CTVprostate+3mm. The model fit was used for estimating the dosimetric impact in equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy. RESULTS: Needle migration was on average 2.2 ± 1.8 mm SD from MRI1-MRI2 and 5.0 ± 3.0 mm SD from MRI1-MRI3. D90 CTVprostate+3mm was robust toward average needle migration ≤3 mm, whereas for migration >3 mm D90 decreased by 4.5% per mm. A 3 mm of needle migration resulted in a decrease of 0.9, 1.7, 2.3, 4.8, and 7.6 equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy, respectively. CONCLUSIONS: Substantial needle migration in high-dose-rate brachytherapy occurs frequently in 1-3 hours following needle insertion. A 3-mm threshold of needle migration is proposed, but 2 mm may be considered for dose levels ≥15 Gy.


Assuntos
Braquiterapia/instrumentação , Migração de Corpo Estranho/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Idoso , Braquiterapia/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Agulhas , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
13.
Radiother Oncol ; 123(1): 125-132, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28284493

RESUMO

BACKGROUND AND PURPOSE: The purpose was to evaluate the dosimetric impact of target contouring and needle reconstruction uncertainties in an US-, CT- and MRI-based HDR prostate BT treatment planning. MATERIAL AND METHODS: US, CT, and MR images were acquired post-needle insertion in 22 HDR-BT procedures for 11 consecutive patients. Dose plans were simulated for an US-, CT- and MRI-based HDR-BT treatment planning procedure. Planning uncertainties in US- and CT-based plans were evaluated using MRI-based planning as reference. Target (CTVProstate) was re-contoured on MRI. Dose results were expressed in total equivalent dose given in 2Gy fractionation dose for EBRT (46Gy) plus 2 HDR-BT fractions. RESULTS: Uncertainties in US- and CT-based planning caused the planned CTVProstate-D90% to decrease with a mean of 2.9±5.0Gy (p=0.03) and 2.9±2.9Gy (p=0.001), respectively. The intra-observer contouring variation on MRI resulted in a mean variation of 1.6±1.5Gy in CTVProstate-D90%. Reconstruction uncertainties on US resulted in a dose variation of±3Gy to the urethra, whereas data for CT were not available for this. CONCLUSIONS: Uncertainties related to contouring and reconstruction in US- and CT-based HDR-BT treatment plans resulted in a systematic overestimation of the prescribed target dose. Inter-modality uncertainties (US and CT versus MR) were larger than MR intra-observer uncertainties.


Assuntos
Braquiterapia/métodos , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Fracionamento da Dose de Radiação , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Incerteza
14.
Radiother Oncol ; 118(1): 154-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26631646

RESUMO

BACKGROUND AND PURPOSE: Adaptive radiotherapy (ART) using plan selection is being introduced clinically for bladder cancer, but the challenge of how to compensate for intra-fractional motion remains. The purpose of this study was to assess target coverage with respect to intra-fractional motion and the potential for normal tissue sparing in MRI-guided ART (MRIGART) using isotropic (MRIGARTiso), an-isotropic (MRIGARTanIso) and population-based margins (MRIGARTpop). MATERIALS AND METHODS: Nine bladder cancer patients treated in a phase II trial of plan selection underwent 6-7 weekly repeat MRI series, each with volumetric scans acquired over a 10 min period. Adaptive re-planning on the 0 min MRI scans was performed using density override, simulating a hypo-fractionated schedule. Target coverage was evaluated on the 10 min scan to quantify the impact of intra-fractional motion. RESULTS: MRIGARTanIso reduced the course-averaged PTV by median 304 cc compared to plan selection. Bladder shifts affected target coverage in individual fractions for all strategies. Two patients had a v95% of the bladder below 98% for MRIGARTiso. MRIGARTiso decreased the bowel V25 with 15-46 cc compared to MRIGARTpop. CONCLUSION: Online re-optimised ART has a considerable normal tissue sparing potential. MRIGART with online corrections for target shift during a treatment fraction should be considered in ART for bladder cancer.


Assuntos
Imageamento por Ressonância Magnética/métodos , Radioterapia Guiada por Imagem , Neoplasias da Bexiga Urinária/radioterapia , Feminino , Humanos , Masculino , Planejamento da Radioterapia Assistida por Computador/métodos
15.
Brachytherapy ; 14(1): 56-61, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25176182

RESUMO

PURPOSE: This study evaluated the dose delivered to lymph nodes (LNs) by brachytherapy (BT) and the effect of BT image-guided optimization on the LN dose. METHODS AND MATERIALS: Twenty-five patients with locally advanced cervical cancer were retrospectively analyzed, 16 patients of them had LN involvement. The patients received whole pelvis intensity-modulated radiation therapy (45-50 Gy/25-30 fx) to whole pelvis and two fractions of MRI pulsed-dose-rate BT. The delineated LN groups were para-aortic, inguinal, common iliac (CI), external iliac, internal iliac, obturator, and presacral. For each LN group, D98%, D50%, and D2% (the dose that covers 98%, 50%, and 2% of the volume, respectively) were evaluated for optimized and standard BT plans. The correlation between total reference air kerma (TRAK) and D50% of the LN groups was evaluated. RESULTS: BT contributed considerable dose (mean D50% was 3.8-6.2 Gy equivalent total dose in 2-Gy fractions) to the pelvic LN (external iliac, internal iliac, obturator, and presacral) in optimized plans, whereas less-dose contribution to CI, para-aortic, and inguinal (mean D50% was 0.5-1.9 Gy equivalent total dose in 2-Gy fractions) was observed. Optimized plans delivered less dose to the LNs as compared with standard plans, although differences only amounted to a mean of 0.2-0.9 Gy (D50%). TRAK showed a significant correlation with LN D50% for all LN groups except CI, although only 19-38% of the dose variation could be explained by the TRAK. CONCLUSIONS: BT contributes considerable dose to pelvic LNs and should be considered in the evaluation of total LN doses.


Assuntos
Braquiterapia/métodos , Irradiação Linfática/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Feminino , Humanos , Canal Inguinal , Metástase Linfática , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Pelve , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
16.
Magn Reson Imaging ; 20(3): 249-60, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12117607

RESUMO

This article aims to describe early left ventricular diastolic inflow using magnetic resonance velocity mapping in patients with recent acute myocardial infarction and in normal volunteers. Magnetic resonance velocity mapping was performed in a long axis plane through the hearts of 46 patients with recent, first time acute myocardial infarction and 43 age-matched normal volunteers. The peak velocities at six levels of the early diastolic inflow stream were recorded. A velocity index was calculated as the peak velocity in each position relative to the peak velocity at the mitral leaflet tips. Also, the temporal delay of velocity propagation was computed. Velocity index 4 cm downstream of mitral leaflet tips was lower in the acute myocardial infarction group (0.42 (0.17)) (mean (SD)) compared to controls (0.59 (0.25)) (p < 0.001). Temporal delay in the same position was longer in the acute myocardial infarction group (62 (67) ms) than in controls (32 (39) ms) (p < 0.02). Blood flow patterns in patients after acute myocardial infarction were characterized by increased dispersion of velocities and increased temporal delay of velocity propagation, probably reflecting impaired active left ventricular relaxation. Intraventricular flow measurements constitute a promising new technique for non-invasive assessment of left ventricular diastolic function.


Assuntos
Imageamento por Ressonância Magnética , Infarto do Miocárdio/fisiopatologia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Análise de Variância , Velocidade do Fluxo Sanguíneo , Diástole/fisiologia , Ecocardiografia Doppler de Pulso , Humanos , Pessoa de Meia-Idade , Fatores de Tempo
17.
Radiother Oncol ; 107(1): 32-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23333020

RESUMO

PURPOSE: This study explores the feasibility of limiting dose optimisation to the first brachytherapy fraction (BT1) and applying the same plan for the second fraction (BT2). MATERIAL AND METHODS: Seventy one consecutive patients were analysed. Pulsed dose rate (PDR) BT was initiated after about 4 weeks of external beam radiotherapy (EBRT). Thirty eight patients had only intracavitary applicator (IC), and 33 had combined IC with interstitial needles (IC/IS). The optimised BT1 plan was copied to BT2 images with no further optimisation (single plan scenario) and dose volume histogram (DVH) parameters were compared with those of full dose optimisation for every fraction (optimised plan scenario). RESULTS: 31/38 IC patients had similar applicator geometry in both fractions and mean DVH parameters were comparable between full optimisation and single plan. The mean HR CTV D90 in total EQD2 with optimisation was 94.5 Gy and with single plan scenario was 94.4 Gy (p=0.89). Organs at risk (OARs) planning aims were fulfilled with the single plan, although 5/31 patients would receive 3-10 Gy extra to the D(2cm(3)). The mean doses in total EQD2 for the D(2cm(3)) of the bladder, rectum, sigmoid and bowel were respectively 68.5, 61.0, 64.9 and 60.6 Gy for the optimised plan, and for the single plan scenario were 69.0, 61.3, 65.1 and 60.8 Gy respectively. The difference was statistically not significant. The standard deviation (SD) of the difference between the single plan and the optimised plan was 3.2 Gy for HR CTV and 2.9, 1.4, 1.2, 1.6 Gy for the bladder, rectum, sigmoid and bowel D(2cm(3)), respectively. Only 4/33 IC/IS patients had the same applicator geometry and single plan was therefore not feasible for the majority of these patients. CONCLUSION: For IC BT in small volume tumours (primarily stage IB-IIB) with mean HR CTV volume at BT1=24±12 cm(3), comparable mean DVH parameters resulted when applying a single plan, but with considerable variations in individual patients. Yet since in our population the applied target doses are high and the OARs doses are lower than the dose volume constraints these variations may not have considerable clinical consequences. Individual optimisation for each BT fraction is recommended when interstitial needles are used.


Assuntos
Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias do Colo do Útero/radioterapia , Estudos de Viabilidade , Feminino , Humanos , Órgãos em Risco , Carga Tumoral , Neoplasias do Colo do Útero/patologia
18.
Radiother Oncol ; 103(1): 113-22, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22296748

RESUMO

The GYN GEC-ESTRO working group issued three parts of recommendations and highlighted the pivotal role of MRI for the successful implementation of 3D image-based cervical cancer brachytherapy (BT). The main advantage of MRI as an imaging modality is its superior soft tissue depiction quality. To exploit the full potential of MRI for the better ability of the radiation oncologist to make the appropriate choice for the BT application technique and to accurately define the target volumes and the organs at risk, certain MR imaging criteria have to be fulfilled. Technical requirements, patient preparation, as well as image acquisition protocols have to be tailored to the needs of 3D image-based BT. The present recommendation is focused on the general principles of MR imaging for 3D image-based BT. Methods and parameters have been developed and progressively validated from clinical experience from different institutions (IGR, Universities of Vienna, Leuven, Aarhus and Ljubljana) and successfully applied during expert meetings, contouring workshops, as well as within clinical and interobserver studies. It is useful to perform pelvic MRI scanning prior to radiotherapy ("Pre-RT-MRI examination") and at the time of BT ("BT MRI examination") with one MR imager. Both low and high-field imagers, as well as both open and close magnet configurations conform to the requirements of 3D image-based cervical cancer BT. Multiplanar (transversal, sagittal, coronal and oblique image orientation) T2-weighted images obtained with pelvic surface coils are considered as the golden standard for visualisation of the tumour and the critical organs. The use of complementary MRI sequences (e.g. contrast-enhanced T1-weighted or 3D isotropic MRI sequences) is optional. Patient preparation has to be adapted to the needs of BT intervention and MR imaging. It is recommended to visualise and interpret the MR images on dedicated DICOM-viewer workstations, which should also assist the contouring procedure. Choice of imaging parameters and BT equipment is made after taking into account aspects of interaction between imaging and applicator reconstruction, as well as those between imaging, geometry and dose calculation. In a prospective clinical context, to implement 3D image-based cervical cancer brachytherapy and to take advantage of its full potential, it is essential to successfully meet the MR imaging criteria described in the present recommendations of the GYN GEC-ESTRO working group.


Assuntos
Braquiterapia , Imageamento por Ressonância Magnética , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Imageamento Tridimensional , Dosagem Radioterapêutica , Carga Tumoral , Neoplasias do Colo do Útero/patologia
19.
Ann Thorac Surg ; 85(2): 599-603, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18222273

RESUMO

BACKGROUND: Extracardiac total cavo-pulmonary connection (TCPC) bypasses the right atrium and has in theory better hemodynamics than intraatrial TCPC repair. Both are thought to have inferior hemodynamics compared with a normal circulation. Direct comparison of flow rates at rest and during exercise with magnetic resonance imaging technique have not been performed. METHODS: The study comprised 20 children. Six children (median age, 9.3 years; interquartile range, 2.2) had undergone extracardiac TCPC. Eight children (median age, 8.9 years; interquartile range, 5.0) had an intraatrial TCPC, and 6 children (median age, 10.3 years; interquartile range, 2.6) were healthy control subjects. Blood flows in the aorta, inferior vena cava, and superior vena cava were measured at rest and during two levels of submaximal supine bicycle exercise (0.5 W/kg and 1.0 W/kg) using a magnetic resonance imaging scanner mounted with a bicycle. RESULTS: Heart rate, respiratory rate, inspiratory fraction, and blood flow rates in the aorta and inferior vena cava increased equally in all three groups. If patients were grouped together, flow rates were significantly lower, and the inspiratory flow fraction in the inferior vena cava was significantly higher, than in control subjects. Retrograde flows were observed in all three groups at rest but tapered off with exercise. CONCLUSIONS: At submaximal levels of lower limb exercise, patients with extracardiac as well as intraatrial TCPC showed a similar increase in respiration, heart rate, and aortic and caval flow rates as healthy control subjects. This is in accordance with the observation that many patients with TCPC perform well during daily life activities.


Assuntos
Exercício Físico/fisiologia , Técnica de Fontan/métodos , Derivação Cardíaca Direita/métodos , Cardiopatias Congênitas/cirurgia , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Seguimentos , Cardiopatias Congênitas/diagnóstico , Frequência Cardíaca , Hemodinâmica/fisiologia , Humanos , Masculino , Probabilidade , Artéria Pulmonar/fisiologia , Artéria Pulmonar/cirurgia , Respiração , Medição de Risco , Estatísticas não Paramétricas , Decúbito Dorsal , Resultado do Tratamento
20.
J Magn Reson Imaging ; 22(2): 213-8, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16028253

RESUMO

PURPOSE: To experimentally investigate the optimum dose of an iron-oxide-based blood pool agent for spiral coronary MR angiography (MRA), and the difference between single and multiple spiral excitations in each cardiac cycle. MATERIALS AND METHODS: Images using single and triple spiral excitations in each cardiac cycle were obtained in late diastole of the left main coronary artery in eight pigs following an inversion prepulse. Measurements were obtained before and after injection of increasing doses of an iron oxide blood pool agent (Clariscan) corresponding to concentrations of 0.8, 2.2, and 3.9 mg Fe/kg BW. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. RESULTS: For 0.8 mg Fe/kg BW relative to precontrast values, a significant increase was observed for both one (SNR: 2.3, CNR: 3.8) and three (SNR: 1.4, CNR: 2.2) excitations (P < 0.01). When the dose was increased from 0.8 mg Fe/kg BW to 2.2 mg Fe/kg BW, only the SNR (P < 0.01) increased further. Significantly higher CNR (1.6-1.8) and SNR (1.4-1.6) values were seen for one excitation relative to three excitations at all concentrations (P < 0.05). CONCLUSION: At low concentrations, an iron oxide blood pool agent can increase SNR and CNR significantly with both single excitation and triple excitations using an inversion-prepared spiral acquisition scheme. At higher concentrations, T2* effects reduce image quality.


Assuntos
Angiografia Coronária/métodos , Aumento da Imagem/métodos , Ferro , Angiografia por Ressonância Magnética , Óxidos , Animais , Meios de Contraste , Dextranos , Relação Dose-Resposta a Droga , Feminino , Óxido Ferroso-Férrico , Nanopartículas de Magnetita , Masculino , Modelos Animais , Sensibilidade e Especificidade , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA