RESUMO
OBJECTIVES: Lung ultrasound (LUS) might be comparable to chest computed tomography (CT) in detecting parenchymal and pleural pathology, and in monitoring interstitial lung disease. We aimed to describe LUS characteristics of patients during the hospitalization for COVID-19 pneumonia, and to compare the extent of lung involvement at LUS and chest-CT with inflammatory response and the severity of respiration impairment. METHODS: During a 2-week period, we performed LUS and chest CT in hospitalized patients affected by COVID-19 pneumonia. Dosages of high sensitivity C-reactive protein (HS-CRP), d-dimer, and interleukin-6 (IL-6) were also obtained. The index of lung function (P/F ratio) was calculated from the blood gas test. LUS and CT scoring were assessed using previously validated scores. RESULTS: Twenty-six consecutive patients (3 women) underwent LUS 34 ± 14 days from the early symptoms. Among them, 21 underwent CT on the same day of LUS. A fair association was found between LUS and CT scores (R = 0.45, P = .049), which became stronger if the B-lines score on LUS was not considered (R = 0.57, P = .024). LUS B-lines score correlated with IL-6 levels (R = 0.75, P = .011), and the number of involved lung segments detected by LUS correlated with the P/F ratio (R = 0.60, P = .019) but not with HS-CRP and d-Dimer levels. No correlations were found between CT scores and inflammations markers or P/F. CONCLUSION: In patients with COVID-19 pneumonia, LUS was correlated with both the extent of the inflammatory response and the P/F ratio.
Assuntos
COVID-19 , Pneumonia , Insuficiência Respiratória , Proteína C-Reativa , Feminino , Humanos , Interleucina-6 , Pulmão/diagnóstico por imagem , SARS-CoV-2 , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodosRESUMO
Stiff left atrial (LA) syndrome is a distinct phenotype of heart failure with preserved ejection fraction, characterized by predominant high LA pressure. We describe the case of a middle-aged woman who developed exertional breathlessness during low-dose radiotherapy for right breast cancer and who was eventually found to be affected by stiff LA syndrome. Invasive hemodynamics allowed the recognition of pathognomonic tall V waves in the wedge position during exercise, in spite of inconclusive noninvasive investigations.
Assuntos
Função do Átrio Esquerdo/efeitos da radiação , Neoplasias da Mama/radioterapia , Cateterismo Cardíaco , Teste de Esforço , Insuficiência Cardíaca/diagnóstico , Hemodinâmica/efeitos da radiação , Doses de Radiação , Lesões por Radiação/diagnóstico , Pressão Atrial/efeitos dos fármacos , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Lesões por Radiação/etiologia , Lesões por Radiação/fisiopatologia , Radioterapia Adjuvante/efeitos adversos , SíndromeRESUMO
BACKGROUND: There is controversy about the outcome of patients with acute myocarditis (AM), and data are lacking on how patients admitted with suspected AM are managed. We report characteristics, in-hospital management, and long-term outcome of patients with AM based on a retrospective multicenter registry from 19 Italian hospitals. METHODS: A total of 684 patients with suspected AM and recent onset of symptoms (<30 days) were screened between May 2001 and February 2017. Patients >70 years of age and those >50 years of age without coronary angiography were excluded. The final study population comprised 443 patients (median age, 34 years; 19.4% female) with AM diagnosed by either endomyocardial biopsy or increased troponin plus edema and late gadolinium enhancement at cardiac magnetic resonance. RESULTS: At presentation, 118 patients (26.6%) had left ventricular ejection fraction <50%, sustained ventricular arrhythmias, or a low cardiac output syndrome, whereas 325 (73.4%) had no such complications. Endomyocardial biopsy was performed in 56 of 443 (12.6%), and a baseline cardiac magnetic resonance was performed in 415 of 443 (93.7%). Cardiac mortality plus heart transplantation rates at 1 and 5 years were 3.0% and 4.1%. Cardiac mortality plus heart transplantation rates were 11.3% and 14.7% in patients with complicated presentation and 0% in uncomplicated cases (log-rank P<0.0001). Major AM-related cardiac events after the acute phase (postdischarge death and heart transplantation, sustained ventricular arrhythmias treated with electric shock or ablation, symptomatic heart failure needing device implantation) occurred in 2.8% at the 5-year follow-up, with a higher incidence in patients with complicated forms (10.8% versus 0% in uncomplicated AM; log-rank P<0.0001). ß-Adrenoceptor blockers were the most frequently used medications both in complicated (61.9%) and in uncomplicated forms (53.8%; P=0.18). After a median time of 196 days, 200 patients had follow-up cardiac magnetic resonance, and 8 of 55 (14.5%) with complications at presentation had left ventricular ejection fraction <50% compared with 1 of 145 (0.7%) of those with uncomplicated presentation. CONCLUSIONS: In this contemporary study, overall serious adverse events after AM were lower than previously reported. However, patients with left ventricular ejection fraction <50%, ventricular arrhythmias, or low cardiac output syndrome at presentation were at higher risk compared with uncomplicated cases that had a benign prognosis and low risk of subsequent left ventricular systolic dysfunction.
Assuntos
Miocardite , Doença Aguda , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Biópsia , Fármacos Cardiovasculares/uso terapêutico , Feminino , Transplante de Coração , Mortalidade Hospitalar , Hospitalização , Humanos , Itália , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocardite/diagnóstico , Miocardite/mortalidade , Miocardite/fisiopatologia , Miocardite/terapia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Troponina/sangue , Função Ventricular Esquerda , Adulto JovemRESUMO
BACKGROUND: Heart failure patients with implantable cardioverter-defibrillators (ICDs) or an ICD for resynchronization therapy often visit the hospital for unscheduled examinations, placing a great burden on healthcare providers. We hypothesized that Internet-based remote interrogation systems could reduce emergency healthcare visits. METHODS AND RESULTS: This multicenter randomized trial involving 200 patients compared remote monitoring with standard patient management consisting of scheduled visits and patient response to audible ICD alerts. The primary end point was the rate of emergency department or urgent in-office visits for heart failure, arrhythmias, or ICD-related events. Over 16 months, such visits were 35% less frequent in the remote arm (75 versus 117; incidence density, 0.59 versus 0.93 events per year; P=0.005). A 21% difference was observed in the rates of total healthcare visits for heart failure, arrhythmias, or ICD-related events (4.40 versus 5.74 events per year; P<0.001). The time from an ICD alert condition to review of the data was reduced from 24.8 days in the standard arm to 1.4 days in the remote arm (P<0.001). The patients' clinical status, as measured by the Clinical Composite Score, was similar in the 2 groups, whereas a more favorable change in quality of life (Minnesota Living With Heart Failure Questionnaire) was observed from the baseline to the 16th month in the remote arm (P=0.026). CONCLUSIONS: Remote monitoring reduces emergency department/urgent in-office visits and, in general, total healthcare use in patients with ICD or defibrillators for resynchronization therapy. Compared with standard follow-up through in-office visits and audible ICD alerts, remote monitoring results in increased efficiency for healthcare providers and improved quality of care for patients. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00873899.
Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Internet , Qualidade da Assistência à Saúde , Idoso , Feminino , Insuficiência Cardíaca/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Estudos Prospectivos , Qualidade de Vida , Consulta RemotaRESUMO
BACKGROUND: Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. OBJECTIVE: We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. METHODS: Two hundred patients implanted with a wireless transmission-enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. RESULTS: Overall, remote monitoring did not show significant annual cost savings for the health care system (1962.78 versus 2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (291.36 versus 381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of 888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. CONCLUSIONS: Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. TRIAL REGISTRATION: ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f).
Assuntos
Análise Custo-Benefício , Desfibriladores Implantáveis , Insuficiência Cardíaca/cirurgia , Monitorização Fisiológica/métodos , Desfibriladores Implantáveis/economia , Insuficiência Cardíaca/fisiopatologia , Humanos , Monitorização Fisiológica/economiaRESUMO
Background: Pulmonary artery wedge pressure (PAWP) during exercise, as a surrogate for left ventricular (LV) end-diastolic pressure (EDP), is used to diagnose heart failure with preserved ejection fraction (HFpEF). However, LVEDP is the gold standard to assess LV filling, end-diastolic PAWP (PAWPED) is supposed to coincide with LVEDP and mean PAWP throughout the cardiac cycle (PAWPM) better reflects the haemodynamic load imposed on the pulmonary circulation. The objective of the present study was to determine precision and accuracy of PAWP estimates for LVEDP during exercise, as well as the rate of agreement between these measures. Methods: 46 individuals underwent simultaneous right and left heart catheterisation, at rest and during exercise, to confirm/exclude HFpEF. We evaluated: linear regression between LVEDP and PAWP, Bland-Altman graphs, and the rate of concordance of dichotomised LVEDP and PAWP ≥ or < diagnostic thresholds for HFpEF. Results: At peak exercise, PAWPM and LVEDP, as well as PAWPED and LVEDP, were fairly correlated (R2>0.69, p<0.01), with minimal bias (+2 and 0â mmHg respectively) but large limits of agreement (±11â mmHg). 89% of individuals had concordant PAWP and LVEDP ≥ or <25â mmHg (Cohen's κ=0.64). Individuals with either LVEDP or PAWPM ≥25â mmHg showed a PAWPM increase relative to cardiac output (CO) changes (PAWPM/CO slope) >2â mmHg·L-1·min-1. Conclusions: During exercise, PAWP is accurate but not precise for the estimation of LVEDP. Despite a good rate of concordance, these two measures might occasionally disagree.
RESUMO
BACKGROUND: Atrial fibrillation (AF) is an uncommon arrhythmia in young adults without structural heart disease, and cryoballoon pulmonary vein isolation (CB-PVI) is an important therapeutic strategy for rhythm control in patients with drug-refractory AF. The aim of this analysis was to evaluate efficacy and safety of CB-PVI in a large cohort of young patients in comparison with middle-aged adults in a real-world setting. METHODS: From 2012 to 2020, a total of 3033 patients with AF underwent CB-PVI and were followed prospectively in the framework of the 1STOP Clinical Service project, involving 34 Italian centers. Out of 3033 total 1STOP project subjects, a subgroup of 1318 patients were defined which included a YOUNG group (age ≤ 45 years; n = 368) and a MIDDLE-AGED group (age 60-65 years; n = 950). RESULTS: The acute success rate of PVI did not differ between the two cohorts (99.9 ± 1.3% vs. 99.8 ± 3.2%, p = 0.415). There was no difference in procedural characteristics, and periprocedural complication rates were similar among the two cohort (1.9% vs. 2.3%, p = 0.646). The 12-month freedom from AF recurrence was 88.9% (95% confidence interval [CI]: 84.7-92.0) in the YOUNG cohort and 85.6% (95% CI: 82.9-88.0) in the MIDDLE-AGED group. At 36-month follow-up, freedom from AF recurrence was 72.4% (65.5%-78.2%) and 71.8% (67.7%-75.6%), respectively with no significant difference among groups (p = 0.550). CONCLUSION: CB-PVI had similar efficacy and safety in YOUNG and MIDDLE-AGED patients. Younger age did not affect acute procedural results, complication rate, or AF recurrence after a single procedure.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Cardiopatias , Veias Pulmonares , Pessoa de Meia-Idade , Adulto Jovem , Humanos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Recidiva , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodosRESUMO
BACKGROUND: Although the assessment of left atrial (LA) mechanics has been reported to refine atrial fibrillation (AF) risk prediction, it doesn't completely predict AF recurrence. The potential added role of right atrial (RA) function in this setting is unknown. Accordingly, this study sought to evaluate the added value of RA longitudinal reservoir strain (RASr) for the prediction of AF recurrence after electrical cardioversion (ECV). METHODS: We retrospectively studied 132 consecutive patients with persistent AF who underwent elective ECV. Complete two-dimensional and speckle-tracking echocardiography analyses of LA and RA size and function were obtained in all patients before ECV. The end point was AF recurrence. RESULTS: During a 12-month follow-up, 63 patients (48%) showed AF recurrence. Both LASr and RASr were significantly lower in patients experiencing AF recurrence than in patients with persistent sinus rhythm (LASr, 10% ± 6% vs 13% ± 7%; RASr, 14% ± 10% vs 20% ± 9%, respectively; P < .001 for both). Right atrial longitudinal reservoir strain (area under the curve = 0.77; 95% CI, 0.69-0.84; P < .0001) was more strongly associated with the recurrence of AF after ECV than LASr (area under the curve = 0.69; 95% CI, 0.60-0.77; P < .0001). Kaplan-Meier curves showed that patients with both LASr ≤ 10% and RASr ≤ 15% had a significantly increased risk for AF recurrence (log-rank, P < .001). However, at multivariable Cox regression, RASr (hazard ratio, 3.26; 95% CI, 1.73-6.13; P < .001) was the only parameter independently associated with AF recurrence. Right atrial longitudinal reservoir strain was more strongly associated with the occurrence of AF relapse after ECV than LASr, and LA and RA volumes. CONCLUSION: Right atrial longitudinal reservoir strain was independently and more strongly associated than LASr with AF recurrence after elective ECV. This study highlights the importance of assessing the functional remodeling of both the RA and LA in patients with persistent AF.
Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Estudos Retrospectivos , Átrios do Coração/diagnóstico por imagem , Ecocardiografia/métodos , RecidivaRESUMO
PURPOSE: Some implantable cardioverter-defibrillators (ICDs) are now able to monitor intrathoracic impedance. The aim of the study was to describe the use of such monitoring in clinical practice and to evaluate the clinical impact of the fluid accumulation alert feature of these ICDs. METHODS AND RESULTS: Five hundred thirty-two heart failure (HF) patients implanted with these ICDs were followed up for 11 +/- 7 months. A clinical event (CE) was deemed to have occurred if it resulted in hospitalization or milder manifestations of HF deterioration. Three hundred sixty-two acute decreases in intrathoracic impedance (Z events) occurred in 230 patients. Of these episodes, 171 (47%) were associated with a CE within 2 weeks of the Z event. In another 71 (20%) Z events, drug therapy was adjusted despite the absence of overt signs of clinical deterioration. The rate of unexplained Z events was 0.25 per patient-year and 25 hospitalizations were not associated with Z events. The audible alert was disabled in a group of 102 patients (OFF group). HF hospitalizations occurred in 29 (7%) patients in the ON group and 20 (20%, P < 0.001) patients in the OFF group. The rate of combined cardiac death and HF hospitalization was lower in patients with Alert ON (log-rank test, P = 0.007). CONCLUSIONS: The ICD reliably detected CE and yielded low rates of unexplained and undetected events. The alert capability seemed to reduce the number of HF hospitalizations by allowing timely detection and therapeutic intervention.
Assuntos
Cardiografia de Impedância/estatística & dados numéricos , Desfibriladores Implantáveis/estatística & dados numéricos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Hospitalização/estatística & dados numéricos , Medição de Risco/métodos , Idoso , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Itália/epidemiologia , Masculino , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Resultado do TratamentoRESUMO
PURPOSE: The aim of the present study is to evaluate if remote monitoring with the CareLink Network may improve clinical management of tachyarrhythmias and heart failure episodes in patients treated with biventricular defibrillators (CRT-D). METHODS: Patients implanted with CRT-D for more than 6 months received the CareLink monitor and were trained to perform device interrogation. At-home transmissions were scheduled at 2 weeks, 1 and 2 months after training, with a final in-office visit after 3 months. RESULTS: Sixty-seven patients performed 264 data transmissions. Twenty-three unscheduled data transmissions were requested by the centers after patient contact. Ventricular tachyarrhythmias were reported in nine patients during 16 data reviews. Thirteen data reviews (81%) were performed remotely via CareLink transmissions (nine scheduled and four unscheduled), in seven patients. Of these events, in two cases (15%) in-hospital visits were requested, while in 11 (85%) no action was needed and no additional in-clinic visits were scheduled. During the study period, in 20/28 (71%) intra-thoracic impedance alerts, the patients remotely transmitted their device data. After remote data review, in ten cases drug therapy was adjusted by phone and in four cases no action was needed and the patient reassured. In six episodes an in-hospital extra visit was scheduled. On the whole, in 14 cases (70%), the patient could be managed remotely avoiding a visit to the hospital. CONCLUSIONS: Our study showed that remote follow-up is an efficient method to manage tachyarrhythmias and heart failure episodes in CRT-D patients. Early reaction to clinical events may improve overall patient care.
Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevenção & controle , Desfibriladores Implantáveis , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Telemedicina/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do TratamentoRESUMO
OBJECTIVES: Amiodarone-induced thyrotoxicosis (AIT) affects up to 3% of treated patients. Type 2 AIT (AIT2) is a destructive thyroiditis and is usually treated with medium-high oral doses of prednisone. As AIT may worsen the underlying heart disease, a rapid control of thyroid function is desirable. We aimed to determine whether a combined intravenous methylprednisolone (IVMP) pulses therapy associated to prednisone in the interpulse period can represent an efficient and safe alternative to urgent total thyroidectomy in patients with AIT2 not responsive to prednisone alone. DESIGN AND METHODS: Patients presenting with a severe AIT2 studied in a tertiary referral Center from August 2018 to April 2019. We included four patients requiring a rapid improvement of thyroid function for their underlying cardiac disorders. The baseline doses of oral prednisone (range: 5-12.5 mg/day) and IVMP (range: 250-500 twice a week) were determined according to the severity of the thyrotoxicosis and were titrated based on clinical response. RESULTS: Combined treatment was effective in all patients in the prompt restoration of euthyroidism and no major adverse events were reported during the follow-up. In all cases, FT4 and FT3 levels normalized at 3-5 weeks of treatment. A permanent hypothyroidism was observed in one patient, 3 months after the discontinuation of treatment. CONCLUSIONS: We report for the first time that the combined intravenous and oral steroid therapy is effective in patients with AIT2. The treatment is well tolerated and leads to a rapid improvement of thyroid function, avoiding urgent total thyroidectomy and favoring a quick functional recovery and rehabilitation of cardiac patients.
Assuntos
Amiodarona/efeitos adversos , Antiarrítmicos/efeitos adversos , Anti-Inflamatórios/administração & dosagem , Anti-Inflamatórios/uso terapêutico , Metilprednisolona/administração & dosagem , Metilprednisolona/uso terapêutico , Tireotoxicose/induzido quimicamente , Tireotoxicose/tratamento farmacológico , Administração Intravenosa , Idoso , Humanos , Iodo/urina , Masculino , Pessoa de Meia-Idade , Tireoglobulina/sangue , Testes de Função Tireóidea , Tireotropina/sangue , Tiroxina/sangue , Tri-Iodotironina/sangueRESUMO
AIMS: Ablation procedures for the treatment of atrial fibrillation lead to changes in autonomic heart control; however, there are insufficient data on the possible association of these changes with atrial fibrillation recurrence. The study aim was to assess the effects of pulmonary vein isolation (PVI) on cardiac autonomic modulation and atrial fibrillation recurrence. METHODS: We screened 52 patients with atrial fibrillation referred for PVI, of whom 20 patients met inclusion and exclusion criteria, and were enrolled in the study and followed over 6 months. Beat-to-beat blood pressure monitoring was performed 1-2 days before PVI, 1 and 6 months after PVI. We estimated pulse interval variability and spontaneous baroreflex sensitivity (BRS) both in the time and frequency domains, and performed the Valsalva manoeuvre assessing the Valsalva ratio. RESULTS: During 6 months after PVI, atrial fibrillation recurrence was observed in six patients. One month after PVI, pulse interval variability and BRS (sequence method) significantly decreased in all patients, returning to preintervention values by 6 months. Patients without atrial fibrillation recurrence at 1 month showed a transient reduction in pulse interval variability (frequency domain) and in BRS (both methods) in contrast to those with atrial fibrillation recurrence. A significant decrease in the Valsalva ratio observed at 1 month was maintained at 6 months after PVI in both groups. CONCLUSION: Successful PVI may lead to transient autonomic alterations reflected by a reduction in pulse interval variability and BRS, with more prolonged changes in the Valsalva ratio. The efficacy of PVI in preventing atrial fibrillation recurrence seems to be related to transient parasympathetic atrial denervation.
Assuntos
Técnicas de Ablação , Fibrilação Atrial/cirurgia , Sistema Nervoso Autônomo/fisiopatologia , Pressão Sanguínea , Átrios do Coração/inervação , Frequência Cardíaca , Veias Pulmonares/cirurgia , Técnicas de Ablação/efeitos adversos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Barorreflexo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo , Resultado do TratamentoRESUMO
PURPOSE: The Medtronic CareLink allows remote implantable device follow-up. In this first European experience with CareLink, we assessed the ease of use of the system, the acceptance, and satisfaction of patients and clinicians. METHODS: Patients implanted with biventricular defibrillators for more than 6 months received the CareLink monitor and were trained to perform home device interrogation and transmission. Patient and clinician experience and preference were evaluated through specific questionnaires. RESULTS: Sixty-seven patients were enrolled and were able to perform data transmissions during the 3-month study duration. The overall duration of interrogation procedure was 7 +/- 5 minutes, and frequently the procedure did not require the assistance of a caregiver. Patients reported a general preference for remote versus in-clinic follow-up and described a sense of reassurance created by the remote monitoring capability.In the centers, the review procedure was successful; its mean duration was 5 +/- 2 minutes per transmission and the users indicated that the access and navigation of the review website were easy. At the end of the evaluation, the data available for remote review were judged complete and adequate to provide almost the same standard of care as that offered in traditional in-clinic visit. In general, the remote monitoring was seen as a potential tool to improve the clinical management of patients with device. CONCLUSIONS: The ease of use, satisfaction, and acceptance of the CareLink Network in European clinical practice appears elevated both for patients and for clinicians.
Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/prevenção & controle , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Satisfação do Paciente/estatística & dados numéricos , Consulta Remota/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-IdadeRESUMO
PURPOSE: To determine the association between device-determined diagnostic indices, including intrathoracic impedance, and heart failure (HF) hospitalization. METHODS: Clinical and device diagnostic data of 558 HF patients indicated for CRT-D therapy (In Sync Sentry, Medtronic Inc.) were prospectively collected from 34 centers. Device-recorded intrathoracic impedance fluid index threshold crossing event (TCE), mean activity counts, tachyarrhythmia events, night heart rate (NHR) and heart rate variability (HRV) were compared within patients with vs. without documented HF hospitalization. RESULTS: Mean follow-up was 326 +/- 216 days. Patients hospitalized for HF had significantly higher rates of TCE, a higher percentage of days with the thoracic impedance fluid index above the programmed threshold, a higher percentage of days with low activity, with low HRV or with high NHR. Multivariate analysis showed that TCE resulted in a 36% increased probability of HF hospitalization. Both TCE duration and patient activity were also significantly associated with hospitalization. Kaplan Meier analysis indicated that patients with more TCE events were significantly more likely to be hospitalized (log rank test, p = 0.005). CONCLUSIONS: Decreased intrathoracic impedance, low patient activity and low HRV were all independently associated with increased risk for HF hospitalization in HF patients treated with resynchronization therapy. Device-derived diagnostic data may provide valuable and reliable indices for the prognostic stratification of HF patients.
Assuntos
Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hospitalização , Idoso , Cardiografia de Impedância , Feminino , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Modelos Logísticos , Masculino , Distribuição de Poisson , Estudos Prospectivos , RiscoRESUMO
OBJECTIVE: Coherent averaging is a technique to recover the response to repetitively applied stimuli when that response is embedded in random noise. We derived novel indices for left ventricular dyssynchrony estimation from volume-catheter signals using coherent averaging procedure: mechanical dyssynchrony (DYSCoh) internal flow fraction (IFFCoh) and mechanical dispersion (DISPCoh). The percentage power of non-repetitive components in the volume signals (ResTotAvg) was also estimated. The aims of the study were to evaluate the indices, characterizing repetitive and non-recurrent components of the conductance-volume signals, and to assess the ability of these indices to detect the changes in dyssynchrony induced by biventricular pacing (BIV). METHODS: We compared the results obtained in 20 heart failure patients indicated to BIV (HF Group) during spontaneous conduction with the results from 12 patients with preserved ventricular function (non-HF Group), and with those obtained during BIV. RESULTS: DISPCoh and ResTotAvg were significantly different in HF compared to non-HF group, and identified HF patients with high accuracy (area under curve at ROC analysis > 0.8). These indices also demonstrated significant differences after BIV (p = 0.047 and p = 0.037 respectively) and their baseline values correlated with the acute increase of stroke volume (r = 0.64 and r = 0.78, both with p < 0.005). CONCLUSIONS: Coherent averaging-based indices permit independent quantification and differentiation of repetitive components of ventricular dyssynchrony from non-recurrent mechanical non-uniformities, which seem associated with HF and conduction disturbances. These indices identified HF patients with high accuracy, and were able to describe the reversal of dyssynchrony caused by BIV and to predict the acute hemodynamic improvement.
Assuntos
Algoritmos , Cateterismo de Swan-Ganz/métodos , Diagnóstico por Computador/métodos , Insuficiência Cardíaca/diagnóstico , Manometria/métodos , Pletismografia de Impedância/métodos , Disfunção Ventricular Esquerda/diagnóstico , Idoso , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/complicaçõesRESUMO
Aim The Program to Access and Review Trending iNformation and Evaluate coRrelation to Symptoms in patients with Heart Failure (PARTNERS HF) trial elaborated a multiparametric model for prediction of acute decompensation in advanced heart failure patients, based on periodical in office data download from cardiac resynchronisation devices. In this study, we evaluated the ability of the PARTNERS HF criteria to detect initial decompensation in a population of moderate heart failure patients under remote monitoring. Methods We retrospectively applied the PARTNERS HF criteria to 1860 transmissions from 104 patients (median follow up 21 months; range 1-67 months), who were enrolled in our programme of telemedicine after cardiac resynchronisation therapy. We tested the ability of a score based on these criteria to predict any acute clinical decompensation occurring in the 15 days following a transmission. Results In 441 cases, acute heart failure was diagnosed after the index transmission. The area under the curve (AUC) of the score for the diagnosis of acute decompensation was 0.752 (confidence interval (CI) 95% 0.728-0.777). The best score cut-off was consistent with the results of PARTNERS HF: with a score ≥2, sensitivity was 75% and specificity 68%. The odds ratio for events was 6.24 (CI 95% 4.90-7.95; p < 0.001). Conclusions When retrospectively applied to remote monitoring transmissions and arranged in a score, PARTNERS HF criteria could identify HF patients who subsequently developed acute decompensation. These results warrant prospective studies applying PARTNERS HF criteria to remote monitoring.
Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Telemedicina/métodos , Idoso , Gerenciamento Clínico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos RetrospectivosRESUMO
AIM: Mitral regurgitation (MR) is a common finding in patients with heart failure with debatable effects on prognosis. Reduction in MR is one of the mechanisms by which cardiac resynchronization therapy (CRT) exerts its beneficial effects. We investigated the prognostic impact of baseline MR and MR persistence after CRT on outcomes of treated patients. METHODS AND RESULTS: We prospectively followed 1122 CRT patients (66.4 ± 10.3 years, 78% male) who were stratified according to baseline MR severity as having MR- (degree 0-1; n = 508, 45%) or MR+ (degrees 2-3-4; n = 614, 55%). In 916 patients (82%) with MR severity data available at 1-year follow-up, the annual mortality rate was 3.4 and 6.0 per patient-year in the MR- and MR+ group, respectively, with a 1-year incidence rate ratio (IRR) of 1.76 (P < 0.001). Similar results were observed for cardiovascular mortality (1-year IRR 1.72, P = 0.002). When considering survival according to MR severity after CRT, all-cause and cardiovascular mortality were lower in the improved than in the worsened group (1-year IRR 1.87 and 2.33, respectively; both P < 0.001). Regression analysis showed that absence of MR improvement at follow-up was a significant independent predictor of both all-cause and cardiovascular mortality. CONCLUSIONS: Baseline significant MR and absence of MR improvement after CRT are strongly predictive of less favourable long-term survival.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/fisiopatologia , Mortalidade , Idoso , Doenças Cardiovasculares/mortalidade , Causas de Morte , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Análise Multivariada , Prognóstico , Modelos de Riscos Proporcionais , Índice de Gravidade de Doença , Resultado do TratamentoAssuntos
Insuficiência Cardíaca , Taquicardia Ventricular , Arritmias Cardíacas , Eletrocardiografia , Humanos , Masculino , PrótonsRESUMO
BACKGROUND: Ventricular resynchronization is a non-pharmacological treatment for advanced heart failure refractory to drug therapy and with intraventricular conduction delay. We describe the time course of echocardiographic and functional recovery after resynchronization in 31 patients (mean age 67 +/- 8 years). METHODS: We evaluated NYHA class, echocardiogram, respiratory function, and cardiopulmonary test before pacemaker implantation (baseline), after 1-3 months (short-term evaluation), and 10-15 months afterwards (long-term evaluation, n = 21 patients). Mortality at 1 year was considered. RESULTS: Both at short and long-term, patients improved NYHA class, ventricular function, and ventricular volumes. Already at short-term, we observed an increase in oxygen consumption at peak exercise (12.6 +/- 0.6 vs 10.5 +/- 0.5 ml/kg/min), oxygen consumption at anaerobic threshold (9.8 +/- 0.6 vs 8.3 +/- 0.6 ml/kg/min) and oxygen pulse (8.3 +/- 0.5 vs 7.5 +/- 0.5 ml/beat). Ventilatory efficacy (VE/VCO2 slope) and alveolo-capillary diffusion (estimated by the measurement of lung diffusion capacity for carbon monoxide - DLCO) improved only at long-term (VE/VCO2: 40.7 +/- 1.6 vs 45.3 +/- 1.8; DLCO: 70.3 +/- 2.7 vs 59.4 +/- 5.9% of predicted, p = 0.05). The 1-year mortality was 9.7%. CONCLUSIONS: Ventricular resynchronization is linked to a fast and prolonged recovery of NYHA class, echocardiographic variables and stress tolerance. The improvement of indexes known to carry a prognostic value confirms that ventricular resynchronization can positively interfere with the evolution of the disease.