Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Diabetes Res Clin Pract ; 181: 109070, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34592390

RESUMO

AIMS: To investigate the relationship between single therapeutic interventions and indicatorsofglycemic control in the PRISMA trial, a large study comparing the effects of intensive structured SMBG (ISM) vs. active control (AC) in non-insulin-treated type 2 diabetes (T2D). METHODS: Information was collected at four time points, corresponding to months 3, 6, 9, and 12 and visits 2, 3, 4, and 5, respectively. Data on therapeutic interventions, HbA1c levels and the number of hypoglycemic episodes at each visit were analyzed. RESULTS: Intensification of drug therapy occurred in 20.3% vs. 15.6%, and no change in 71.8% vs. 78.7% of visits for the ISM and AC groups, respectively. On the other hand, de-intensification and redistribution of drugs and/or drug dose occurred in a similar proportion of visits. Intensification of drug therapy in both groups was associated with significant reductions in HbA1c vs. the previous visit, while de-intensification of therapy led to a significant increase in HbA1c in the AC group only. CONCLUSIONS: Our data strongly support that structured SMBG has clinical value in reducing HbA1c in non-insulin-treated T2D and suggest that this clinical benefit may be mediated by more appropriate and timely changes in drug therapy.


Assuntos
Glicemia , Diabetes Mellitus Tipo 2 , Automonitorização da Glicemia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/uso terapêutico , Insulina
2.
Audiol Res ; 11(2): 200-206, 2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-34065802

RESUMO

BACKGROUND: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. METHODS: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users' own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users' previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. RESULTS: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users' own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. CONCLUSIONS: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA