1.
Int J Hyperthermia ; 41(1): 2299480, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38189281

RESUMO

OBJECTIVE: To investigate the potential of hybrid Pd/Fe-oxide magnetic nanoparticles designed for thermo-brachytherapy of breast cancer, considering their specific loss power (SLP) and clinical constraints in the applied magnetic field. METHODS: Hybrid nanoparticles consisting of palladium-core and iron oxide shell of increasing thickness, were suspended in water and their SLPs were measured at varying magnetic fields (12-26 mT peak) and frequencies (50-730 kHz) with a commercial alternating magnetic field generator (magneTherm™ Digital, nanoTherics Ltd.). RESULTS: Validation of the heating device used in this study with commercial HyperMag-C nanoparticles showed a small deviation (±4%) over a period of 1 year, confirming the reliability of the method. The integration of dual thermometers, one in the center and one at the bottom of the sample vial, allowed monitoring of homogeneity of the sample suspensions. SLPs measurements on a series of nanoparticles of increasing sizes showed the highest heating for the diameter of 21 nm (SLP = 225 W/g) at the applied frequencies of 346 and 730 kHz. No heating was observed for the nanoparticles with the size <14 nm, confirming the importance of the size-parameter. The heating ability of the best performing Pd/Fe-oxide-21 was calculated to be sufficient to ablate tumors with a radius ±4 and 12 mm using 10 and 1 mg/mL nanoparticle concentration, respectively. CONCLUSIONS: Nanoparticles consisting of non-magnetic palladium-core and magnetic iron oxide shell are suitable for magnetic hyperthermia/thermal ablation under clinically safe conditions of 346 kHz and 19.1 mT, with minimal eddy current effects in combination with maximum SLP.


Assuntos
Braquiterapia , Nanopartículas , Óxidos , Paládio/uso terapêutico , Reprodutibilidade dos Testes , Campos Magnéticos
2.
Radiother Oncol ; 199: 110471, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39127406

RESUMO

BACKGROUND AND PURPOSE: The quality of the Cone Beam Computed Tomography (CBCT) images used for patient set-up is essential to avoid geographical miss when narrower margins or shorter fractionation are used for example in Accelerated Partial Breast Irradiation (APBI). This study evaluates deep inspiration breath hold (DIBH) with skin guided radiotherapy as a tool for image improvement reducing motion artifacts. MATERIALS AND METHODS: Daily CBCT images of left and right breast cancer patients with well-defined surgical cavity on CT simulation were used for this study. Only left sided CBCT were acquired with DIBH. Trained and experienced radiation therapists were asked to evaluate the image quality using a cavity visualization score (CVS), an image quality Likert score, and to perform registration shifts. Images were anonymized and therapists were blinded to the use of DIBH. RESULTS: Images from 21 patients, with 15 CBCT each, were evaluated by 6 radiation therapists, generating 4,015 evaluation points. Statistically significant improvements were observed in CVS and image quality (p < 0.001) with DIBH. Also, the rate of surgical cavity identification increased to 76 % with DIBH compared to 56 % without (p < 0.001). DIBH significantly reduced the inter-observer variability in registration shift corrections (p < 0.001) CONCLUSION: Utilizing DIBH for motion control improves both the image quality and the surgical cavity identification. This results in a decrease in registration variability, which is important for APBI accuracy.

3.
Phys Med Biol ; 69(4)2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38211314

RESUMO

Objective.Determining and verifying the number of monitor units is crucial to achieving the desired dose distribution in radiotherapy and maintaining treatment efficacy. However, current commercial treatment planning system(s) dedicated to ocular passive eyelines in proton therapy do not provide the number of monitor units for patient-specific plan delivery. Performing specific pre-treatment field measurements, which is time and resource consuming, is usually gold-standard practice. This proof-of-concept study reports on the development of a multi-institutional-based generalized model for monitor units determination in proton therapy for eye melanoma treatments.Approach.To cope with the small number of patients being treated in proton centers, three European institutes participated in this study. Measurements data were collected to address output factor differences across the institutes, especially as function of field size, spread-out Bragg peak modulation width, residual range, and air gap. A generic model for monitor units prediction using a large number of 3748 patients and broad diversity in tumor patterns, was evaluated using six popular machine learning algorithms: (i) decision tree; (ii) random forest, (iii) extra trees, (iv) K-nearest neighbors, (v) gradient boosting, and (vi) the support vector regression. Features used as inputs into each machine learning pipeline were: Spread-out Bragg peak width, range, air gap, fraction and calibration doses. Performance measure was scored using the mean absolute error, which was the difference between predicted and real monitor units, as collected from institutional gold-standard methods.Main results.Predictions across algorithms were accurate within 3% uncertainty for up to 85.2% of the plans and within 10% uncertainty for up to 98.6% of the plans with the extra trees algorithm.Significance.A proof-of-concept of using machine learning-based generic monitor units determination in ocular proton therapy has been demonstrated. This could trigger the development of an independent monitor units calculation tool for clinical use.


Assuntos
Neoplasias Oculares , Melanoma , Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Aprendizado de Máquina , Prótons , Dosagem Radioterapêutica , Neoplasias Oculares/radioterapia
4.
Phys Imaging Radiat Oncol ; 31: 100605, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39050744

RESUMO

Background and purpose: Uveal melanoma (UM) is the most common primary ocular malignancy. We compared fractionated stereotactic radiotherapy (SRT) with proton therapy, including toxicity risks for UM patients. Materials and methods: For a total of 66 UM patients from a single center, SRT dose distributions were compared to protons using the same planning CT. Fourteen dose-volume parameters were compared in 2-Gy equivalent dose per fraction (EQD2). Four toxicity profiles were evaluated: maculopathy, optic-neuropathy, visual acuity impairment (Profile I); neovascular glaucoma (Profile II); radiation-induced retinopathy (Profile III); and dry-eye syndrome (Profile IV). For Profile III, retina Mercator maps were generated to visualize the geographical location of dose differences. Results: In 9/66 cases, (14 %) proton plans were superior for all dose-volume parameters. Higher T stages benefited more from protons in Profile I, especially tumors located within 3 mm or less from the optic nerve. In Profile II, only 9/66 cases resulted in a better proton plan. In Profile III, better retina volume sparing was always achievable with protons, with a larger gain for T3 tumors. In Profile IV, protons always reduced the risk of toxicity with a median RBE-weighted EQD2 reduction of 15.3 Gy. Conclusions: This study reports the first side-by-side imaging-based planning comparison between protons and SRT for UM patients. Globally, while protons appear almost always better regarding the risk of optic-neuropathy, retinopathy and dry-eye syndrome, for other toxicity like neovascular glaucoma, a plan comparison is warranted. Choice would depend on the prioritization of risks.