Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 203
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Card Fail ; 30(10): 1302-1318, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39389742

RESUMO

Secondary mitral regurgitation (SMR) is associated with increased mortality and heart failure hospitalizations. The management of heart failure patients with SMR is complex and requires a multidisciplinary Heart Team approach. Guideline-directed medical therapies remain fundamental, yet in a proportion of patients SMR persists. In the past decade, transcatheter edge-to-edge repair (TEER) has been shown to improve survival in patients with SMR who remain symptomatic despite medical therapy. Technical advancements across newer generations of devices, improved imaging, and greater operator expertise have collectively contributed to the increased safety and efficacy of this procedure over time. Various emerging transcatheter mitral valve repair and replacement devices are currently under investigation and may offer superior, complementary or synergistic treatment options in patients ineligible for TEER. This review provides a state-of-the-art overview regarding the diagnosis of SMR, and currently available transcatheter mitral valve interventions and describes a contemporary approach to the management of SMR.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/terapia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Gerenciamento Clínico
2.
Artigo em Inglês | MEDLINE | ID: mdl-39266422

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) outflow graft obstruction can result in severe clinical deterioration. Underlying mechanisms may vary depending on the location. Outflow graft tamponade due to external compression can be under recognized. Management of this complication varies across institutions and a uniform approach has yet to be elucidated. OBJECTIVES: Report a single center experience with outflow graft tamponade in patients with LVAD with the purpose of developing an optimal algorithm for the diagnosis and treatment of LVAD-related outflow graft tamponade. METHODS AND RESULTS: Retrospective chart review between July 2011 and July 2020. A total of 351 LVADs were implanted at our center, with outflow graft tamponade identified in 26 patients with LVAD. Fourteen (53.8%) had HeartMate II™, 8 (30.8%) had HeartMate3™ and 4 (15.4%) had HeartWare™. Individuals presented with heart failure symptoms, an audible precordial murmur and LVAD alarms after a median duration of 862 days of support (IQR 327 - 1455). Of the 26 patients, 15 (57.7%) underwent mini thoracotomy with outflow graft relief, 4 had percutaneous balloon dilatation and stenting, 2 were bridged directly to transplant and 1 had a pump exchange. No intervention was made on the remaining due to mild symptoms (n = 4). CONCLUSIONS: Conclusions: Outflow graft tamponade is a form outflow graft obstruction with a variable presentation that can result in significant hemodynamic compromise. It is amenable to both surgical and percutaneous interventions that restore LVAD function.

3.
Am J Transplant ; 23(7): 875-890, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36958628

RESUMO

In July 2022, the Scientific Registry of Transplant Recipients (SRTR) hosted an innovative, multistakeholder consensus conference to identify information and metrics desired by stakeholders in the transplantation system, including patients, living donors, caregivers, deceased donor family members, transplant professionals, organ procurement organization professionals, payers, and regulators. Crucially, patients, caregivers, living donors, and deceased donor family members were included in all aspects of this conference, including serving on the planning committee, participating in preconference focus groups and learning sessions, speaking at the conference, moderating conference sessions and breakout groups, and shaping the conclusions. Patients constituted 24% of the meeting participants. In this report, we document the proceedings and enumerate 160 recommendations, 10 of which have been highly prioritized. SRTR will use the recommendations to develop new presentations of information and metrics requested by stakeholders to support informed decision-making.


Assuntos
Obtenção de Tecidos e Órgãos , Transplantes , Humanos , Transplantados , Benchmarking , Sistema de Registros , Doadores de Tecidos , Doadores Vivos
4.
Am J Transplant ; 23(3): 316-325, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36906294

RESUMO

Solid organ transplantation provides the best treatment for end-stage organ failure, but significant sex-based disparities in transplant access exist. On June 25, 2021, a virtual multidisciplinary conference was convened to address sex-based disparities in transplantation. Common themes contributing to sex-based disparities were noted across kidney, liver, heart, and lung transplantation, specifically the existence of barriers to referral and wait listing for women, the pitfalls of using serum creatinine, the issue of donor/recipient size mismatch, approaches to frailty and a higher prevalence of allosensitization among women. In addition, actionable solutions to improve access to transplantation were identified, including alterations to the current allocation system, surgical interventions on donor organs, and the incorporation of objective frailty metrics into the evaluation process. Key knowledge gaps and high-priority areas for future investigation were also discussed.


Assuntos
Fragilidade , Transplante de Órgãos , Obtenção de Tecidos e Órgãos , Feminino , Humanos , Disparidades em Assistência à Saúde , Rim , Doadores de Tecidos , Estados Unidos , Listas de Espera
5.
J Card Fail ; 29(11): 1543-1555, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37633442

RESUMO

The accurate assessment of hemodynamics is paramount to providing timely and efficacious care for patients presenting in cardiogenic shock. Recently, the regular use of the pulmonary artery catheter in cardiogenic shock has had a resurgence with emerging data indicating improved survival in the modern era. Optimal multidisciplinary management of advanced heart failure and cardiogenic shock relies on our ability to effectively communicate and understand the complete hemodynamic assessment. Standardization of data acquisition and a renewed focus on the physiological processes, and thresholds driving disease progression, including the coupling ratio and myocardial reserve, are needed to fully understand and interpret the hemodynamic assessment. This State-of-the-Art review discusses best practices in the cardiac catheterization laboratory as well as emerging data on the prognostic role of emerging advanced hemodynamic parameters.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Choque Cardiogênico , Hemodinâmica/fisiologia , Cateterismo Cardíaco , Padrões de Referência
6.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36958391

RESUMO

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
7.
Artif Organs ; 47(3): 574-581, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36305735

RESUMO

BACKGROUND: Invasive hemodynamic variables obtained from right heart catheterization have been used for risk-stratifying patients with advanced heart failure (HF). However, there is a paucity of data on the prognostic value of invasive hemodynamic variables in patients with left ventricular assist devices (LVAD). We hypothesized that cardiac power output (CPO), cardiac power efficiency (CPE), and left ventricular stroke work index (LVSWI) can serve as prognostic markers in patients with LVADs. METHODS: Baseline hemodynamic data from patients who had LVAD ramp studies at our institution from 4/2014 to 7/2018 were prospectively collected, from which advanced hemodynamic variables (CPO, CPE, and LVSWI) were retrospectively analyzed. Univariate and multivariable analyses were performed for hemocompatibility-related adverse events (HRAE), HF admissions, and mortality. RESULTS: Ninety-one participants (age 61 ± 11 years, 34% women, 40% Black or African American, and 38% ischemic cardiomyopathy) were analyzed. Low CPE was significantly associated with mortality (HR 2.42, 95% CI 1.02-5.74, p = 0.045) in univariate analysis and Kaplan-Meier analysis (p = 0.04). Low LVSWI was significantly associated with mortality (HR 2.13, 95% CI 1.09-4.17, p = 0.03) in univariate analysis and Kaplan-Meier analysis (p = 0.02). CPO was not associated with mortality. CPO, CPE, and LVSWI were not associated with HRAE or HF admissions. CONCLUSIONS: Advanced hemodynamic variables can serve as prognostic indicators for patients with LVADs. Low CPE and LVSWI are prognostic for higher mortality, but no variables were associated with HF admissions or HRAEs.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Prognóstico , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Hemodinâmica , Débito Cardíaco
8.
Am J Transplant ; 22(5): 1299-1306, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34866328

RESUMO

Regulatory oversight for heart transplant programs is currently under review by the United Network for Organ Sharing (UNOS). There is concern whether 1-year patient and graft survival truly represent heart transplant center performance. Thus, a forum was organized by the Thoracic and Critical Care Community of Practice (TCC COP) of the American Society of Transplantation (AST) for the heart transplant community to voice their opinions on matters involving program performance monitoring by UNOS. A TCC COP work group was formed to review outcome metrics for adult heart transplantation and culminated in a virtual community forum (72 participants representing 61 heart transplant programs) on November 12-13, 2020. One-year posttransplant survival is still considered an appropriate and important measure to assess program performance. Waitlist mortality and offer acceptance rate as pretransplant metrics could also be useful measures of program performance, recognizing that outside factors may influence these metrics. In depth discussion of these metrics and other issues including auditing thresholds, innovations to reduce risk-averse behavior and personally designed program scorecards are included in this meeting proceedings.


Assuntos
Benchmarking , Transplante de Coração , Adulto , Sobrevivência de Enxerto , Humanos , Estados Unidos , Listas de Espera
9.
J Card Fail ; 28(5): 845-862, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34980564

RESUMO

The HeartMate 3 left ventricular assist device (LVAD) is now the only centrifugal pump intended for durable support being actively manufactured and implanted for adults in the United States. The changes in preload and afterload that accompany common clinical scenarios experienced by patients with an LVAD will cause specific changes to the LVAD pump parameters, namely, the pump power, pulsatility index, and flow. Appropriate care of this unique, and growing, population requires a full understanding of these variables as well as the underlying physiologic principles governing their derivation. The aim of this review is to focus on the updated functionality of the HeartMate 3, specifically in comparison to the HeartMate II, as well as the application of pump parameter interpretation to common clinical scenarios.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos
10.
J Card Fail ; 28(5): 866-869, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34774746

RESUMO

BACKGROUND: The initial derivation of cardiac power output (CPO) included the difference between mean arterial pressure (MAP) and right atrial pressure (RAP) in the numerator, before multiplying by cardiac output (CO). We hypothesized that the inclusion of RAP (CPO-RAP) would enhance the prognostic performance of this parameter in those with an elevated RAP. METHODS AND RESULTS: We obtained patient-level data from the ESCAPE trial via the Biolincc database. Participants with full final hemodynamics were included in the analysis. The CPO-RAP was calculated as [(MAP - RAP) × CO)]/451 Watts (W), and the CPO was calculated as (MAP × CO)/451. The primary outcome was freedom from left ventricular assist device, heart transplant, or death at 6 months. Included participants (n = 157) were a median of 58 years of age (interquartile range [IQR] 49-67 years), 27% were women, and 59% had ischemic cardiomyopathy. The median CPO was 0.70 W (IQR 0.50-0.90 W), and the median CPO-RAP was 0.62 W (IQR 0.47-0.79 W). In univariable logistic regressions, the CPO was not associated with the primary outcome (odds ratio 0.32, 95% confidence interval 0.08-1.29, P = .11), but the CPO-RAP was (odds ratio 0.10, 95% confidence interval 0.02-0.54, P < .01). In Kaplan-Meier analyses, there were no significant difference in outcomes with CPO (76% vs 64%, P = .08), but for CPO-RAP, there were significant differences in outcomes (81% vs 63%, P = .01). When further delineating CPO-RAP by RAP above or below the median, there was no significant difference in the outcome for participants with a RAP 8 or less (94% vs 79%, P = .07), but a significant difference in participants with a RAP of more than 8 mm Hg (66% vs 45%, P < .05). CONCLUSIONS: The inclusion of RAP resulted in a significant association with the primary outcome; CPO alone was not.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Idoso , Pressão Atrial , Débito Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
11.
J Card Fail ; 28(7): 1158-1168, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35504508

RESUMO

BACKGROUND: As left ventricular assist device (LVAD) survival rates continue to improve, evaluating site-specific variability in outcomes can facilitate identifying targets for quality-improvement initiative opportunities in the field. METHODS: Deidentified center-specific outcomes were analyzed for HeartMate 3 (HM3) patients enrolled in the MOMENTUM 3 pivotal and continued access protocol trials. Centers < 25th percentile for HM3 volumes were excluded. Variability in risk-adjusted center mortality was assessed at 90 days and 2 years (conditional upon 90-day survival). Adverse event (AE) rates were compared across centers. RESULTS: In the 48 included centers (1958 patients), study-implant volumes ranged between 17 and 106 HM3s. Despite similar trial-inclusion criteria, patient demographics varied across sites, including age quartile ((Q)1-Q3:57-62 years), sex (73%-85% male), destination therapy intent (60%-84%), and INTERMACS profile 1-2 (16%-48%). Center mortality was highly variable, nadiring at ≤ 3.6% (≤ 25th percentile) and peaking at ≥ 10.4% (≥ 75th percentile) at 90 days and ≤ 10.2% and ≥ 18.7%, respectively, at 2 years. Centers with low mortality rates tended to have lower 2-year AE rates, but no center was a top performer for all AEs studied. CONCLUSIONS: Mortality and AEs were highly variable across MOMENTUM 3 centers. Studies are needed to improve our understanding of the drivers of outcome variability and to ascertain best practices associated with high-performing centers across the continuum of intraoperative to chronic stages of LVAD support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Taxa de Sobrevida , Resultado do Tratamento
12.
Clin Transplant ; 36(5): e14617, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35191097

RESUMO

BACKGROUND: Patients with end-stage heart failure frequently have significant congestive hepatopathy requiring hepatology assessment prior to heart transplantation listing. An elevated Model for End-stage Liver Disease score with modification to exclude INR (MELD-XI) has been associated with increased mortality following heart transplantation (HT). This study's primary aim was to examine whether Child-Turcotte-Pugh (CTP) classification is associated with post-transplant mortality in patients bridged to transplant with left ventricular assist devices. METHODS AND RESULTS: We conducted a retrospective analysis of 134 patients from our center. Age, CTP class, and MELD-XI at HT were included in the multivariate model for the primary outcome, which demonstrated a significant association between 1-year mortality and CTP class (CTP-A HR: .08, CI .01-.46, P < .01; CTP-B HR: .25, CI .05-1.2, P = .08; reference group CTP-C), and MELD-XI (HR: 1.15; CI: 1.03-1.28; P = .01), but no significant difference for age (HR: .97; CI: .93-1.01; P = .15). Only 13/33 patients with CTP improvement after assist device also had improvement in MELD-XI. CONCLUSIONS: Patients with relatively low MELD-XI scores with discordantly high CTP classification may be a distinct subset for whom MELD-XI underestimates the risk of mortality after heart transplantation compared to CTP.


Assuntos
Doença Hepática Terminal , Transplante de Coração , Coração Auxiliar , Humanos , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença
13.
Heart Vessels ; 37(12): 1995-2001, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35794489

RESUMO

OBJECTIVES: The purpose of this study is to investigate the early and late outcomes of axillary intra-aortic balloon pump (IABP) implantation as a bridge to heart transplantation, comparing the grafted technique with the percutaneous technique. METHODS: Between July 2009 and January 2020, 163 patients underwent an axillary IABP insertion as a bridge to heart transplantation. Among them, 97 patients underwent axillary IABP implantation through a graft sutured onto the axillary artery (Group A) and 66 patients underwent percutaneously (Group B). Propensity matching identified 53 matched pairs for analysis (C-statistics 0.741). The primary outcomes of interest included IABP-related complications, success rate of a bridge to transplantation, in-hospital mortality, and late survival. RESULTS: In the propensity-score matched cohort, there were no significant differences in the baseline characteristics between the two groups. The operation time was significantly longer in Group A than in Group B (141.5 ± 38.3 min vs 42.7 ± 19.3 min, p < 0.01). The complication rates including stroke, re-exploration for bleeding, and aortic event were not significantly different between Group A and B. However, Group A required more transfusion and re-exploration for bleeding. The success rate of a bridge to transplantation was similar between Group A (47/53, 88.7%) and Group B (47/53, 88.7%). There were no significant differences in in-hospital mortality and late survival between two groups. CONCLUSION: In the propensity score matching analysis, there were not any significant differences between the two groups in IABP-related complications, in-hospital mortality, and late survival. The percutaneous technique provided a shorter operation time and less requirement of transfusion and re-exploration for bleeding compared to the grafted technique. The percutaneous technique might be favorable when feasible.


Assuntos
Transplante de Coração , Coração Auxiliar , Humanos , Pontuação de Propensão , Estudos Retrospectivos , Balão Intra-Aórtico/efeitos adversos , Resultado do Tratamento
14.
Heart Vessels ; 37(4): 647-653, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34585275

RESUMO

We sought to assess the impact of the aortic root geometry on developing de novo aortic insufficiency (AI) in patients undergoing left ventricular assist device (LVAD). In total, 114 patients underwent LVAD implantation between February 2016 and January 2020 were included in this study (HeartMate3 N = 68, HeartWare N = 46). Significant aortic insufficiency was defined as mild-to-moderate or greater in echocardiography. The cohort was divided into two groups; those who developed significant AI (Group AI: n = 13) and did not (Group non-AI: n = 101). The primary outcomes of interest included late survival and predictors for significant AI. The patients in Group AI were older than Group non-AI (62.6 ± 11.9 vs 51.3 ± 14.0 years, p < 0.01). The diameter of proximal ascending aorta in Group AI was larger than Group non-AI (31.0 ± 5.0 vs 27.4 ± 4.3 mm, p < 0.01). Aortic valve remained closed in 53.8% in Group AI and 36.6% in Group non-AI (p = 0.24). The late survival was not significantly different between the groups (67.1% vs 76.0% at 3 years, log rank = 0.97). The Cox hazard model showed that larger proximal ascending aortic diameter/BSA (HR 1.55, CI 1.19-2.04, p < 0.01) and not-opening aortic valve (HR 4.73, CI 1.43-16.9, p = 0.01) were independent risk factors for significant AI. The cutoff value of proximal ascending aortic diameter/BSA was 15.5 (area under curve: 0.770, sensitivity: 0.69, specificity: 0.79). Dilated proximal ascending aorta at the time of LVAD surgery and not-opening aortic valve during follow-up were associated with the incidence of de novo significant AI.


Assuntos
Insuficiência da Valva Aórtica , Coração Auxiliar , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Coração Auxiliar/efeitos adversos , Humanos , Incidência , Estudos Retrospectivos , Função Ventricular Esquerda
15.
Ann Vasc Surg ; 83: 42-52, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34995740

RESUMO

OBJECTIVE: Axillary Intra-aortic balloon pump (IABP) has been increasingly utilized for hemodynamic support in heart failure patients. Vascular complications associated with axillary IABP such as dissection or rupture are relatively rare but not negligible that could negatively affect clinical outcomes. We summarized our experiences. METHODS: This is a retrospective study reviewing of all patients receiving an axillary IABP between June 2016 and November 2020. A total of 199 patients underwent percutaneous axillary IABP placement. 6 patients (6/199, 3.0%) were complicated with arterial/aortic dissection or rupture during the procedures or the course of treatment. We described their clinical presentations and outcomes. RESULTS: Vascular complications included acute type A aortic dissection in 2 patients, descending aortic rupture in 1 patient, abdominal aortic rupture along with type B aortic dissection in 1 patient, and the localized left subclavian artery dissection in 2 patient. 2 type A aortic dissection cases were surgically treated: 1 with emergent left ventricle assist device and ascending aorta replacement, the other with emergent left ventricle assist device. Emergent endovascular treatment was successfully performed in 2 aortic rupture cases. The left subclavian artery dissection cases were managed medically. The postoperative/treatment course was uneventful in all patients. CONCLUSION: Percutaneous axillary IABP therapy can cause significant vascular complications. Early diagnosis and prompt treatment would be the key to improve the clinical outcomesv.


Assuntos
Dissecção Aórtica , Ruptura Aórtica , Coração Auxiliar , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
16.
Artif Organs ; 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36574590

RESUMO

PURPOSE: Tolvaptan, a selective vasopressin type-2 antagonist, has been shown to increase serum sodium (Na) and urine output in hyponatremic left ventricular assist device (LVAD) patients in retrospective studies. In this prospective randomized pilot study, we aimed to assess the efficacy of tolvaptan in this population. METHODS: We conducted a prospective, randomized, non-blinded pilot study of LVAD recipients with post-operative hyponatremia (Na < 135 mEq/L) (NCT05408104). Eligible participants were randomized to receive tolvaptan 15 mg daily in addition to usual care versus usual care alone. The primary outcome was a change in Na level and estimated glomerular filtration rate (eGFR), from the first post-operative day of hyponatremia (the day of randomization) to discharge. RESULTS: A total of 33 participants were enrolled, and 28 underwent randomization (median age 55 [IQR 50-62]), 21% women, 54% Black, 32% ischemic cardiomyopathy, median baseline Na 135 (IQR 134-138). Fifteen participants were randomized to tolvaptan (TLV) and 13 were randomized to usual care alone (No-TLV). Mean change in Na from randomization to discharge in the TLV group was 2.7 mEq/L (95%CI 0.7-4.7, p = 0.013) and 1.8 (95%CI 0.5-4.0, p = 0.11) in the No-TLV group, though baseline and final Na levels were similar between groups. The mean change in eGFR was 2.6 ml/min/1.73 m2 (95%CI 10.1-15.3, p = 0.59) in TLV versus 7.5 ml/min/1.73 m2 (95%CI 5.2-20.2, p = 0.15) in No-TLV. TLV participants had significantly more urine output than No-TLV patients during their first 24 h after randomization (3294 vs 2155 ml, p = 0.043). CONCLUSION: TLV significantly increases urine output, with nominal improvement in Na level, in hyponatremic post-operative LVAD patients without adversely impacting renal function.

17.
Int Heart J ; 63(1): 56-61, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35095077

RESUMO

Optimal heart rate (HR) is a promising therapeutic target in patients with heart failure with reduced ejection fraction. Nevertheless, the implication of optimal HR in patients with left ventricular assist devices (LVAD) remains unknown. The cohort included consecutive patients with sinus rhythm undergoing LVAD implantation between 2014 and 2018. Ideal HR was calculated as follows: 93 - 0.13 × (deceleration time [msec]). The impact of "HR difference," defined as an HR difference between the actual HR at discharge and the calculated ideal HR, on the 1-year mortality and heart failure readmissions was investigated. A total of 143 patients (55 years old, 101 men) was identified and tertiled considering their HR differences: (1) the optimal HR group (n = 49; HR difference < 27 bpm), (2) the suboptimal HR group (n = 47; HR difference = 27-42 bpm), and (3) the nonoptimal HR group; HR difference (n = 47; HR difference > 43 bpm). The nonoptimal HR group had a significantly higher 1-year cumulative incidence of the primary endpoint compared with the optimal HR group (38% versus 16%, P = 0.029) with a hazard ratio of 1.69 (95% confidence interval 1.02-2.57) adjusted for 6 potential confounders. In conclusion, nonoptimized HR negatively affected clinical outcomes in LVAD patients. The implication of deceleration time-guided HR optimization in LVAD patients should be further investigated.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Frequência Cardíaca/fisiologia , Coração Auxiliar , Adulto , Idoso , Estudos de Coortes , Feminino , Insuficiência Cardíaca/mortalidade , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Volume Sistólico/fisiologia , Taxa de Sobrevida , Resultado do Tratamento
18.
Circulation ; 141(14): 1184-1197, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32250695

RESUMO

The recent widespread availability and use of mechanical circulatory support is transforming the management and outcomes of cardiogenic shock (CS). Clinical decision-making regarding the optimization of therapies for patients with CS can be guided effectively by hemodynamic monitoring with a pulmonary artery catheter (PAC). Because several studies regarding the benefit of PACs are ambiguous, the use of PACs is variable among clinicians treating patients with CS. More notable is that PAC use has not been studied as part of a randomized, controlled trial in patients with CS with or without mechanical circulatory support. Standardized approaches to hemodynamic monitoring in these patients can improve decision-making and outcomes. In this review, we summarize the hemodynamics of CS and mechanical circulatory support with PAC-derived measurements, and provide a compelling rationale for the use of PAC monitoring in patients with CS receiving mechanical circulatory support.


Assuntos
Monitorização Hemodinâmica/métodos , Choque Cardiogênico/fisiopatologia , Choque Cardiogênico/terapia , Hemodinâmica , Humanos
19.
Am J Transplant ; 21(2): 636-644, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32659872

RESUMO

A consensus conference on frailty in solid organ transplantation took place on February 11, 2018, to discuss the latest developments in frailty, adopt a standardized approach to assessment, and generate ideas for future research. The findings and consensus of the Frailty Heart Workgroup (American Society of Transplantation's Thoracic and Critical Care Community of Practice) are presented here. Frailty is defined as a clinically recognizable state of increased vulnerability resulting from aging-associated decline in reserve and function across multiple physiologic systems such that the ability to cope with every day or acute stressors is compromised. Frailty is increasingly recognized as a distinct biologic entity that can adversely affect outcomes before and after heart transplantation. A greater proportion of patients referred for heart transplantation are older and have more complex comorbidities. However, outcomes data in the pretransplant setting, particularly for younger patients, are limited. Therefore, there is a need to develop objective frailty assessment tools for risk stratification in patients with advanced heart disease. These tools will help to determine appropriate recipient selection for advanced heart disease therapies including heart transplantation and mechanical circulatory support, improve overall outcomes, and help distinguish frailty phenotypes amenable to intervention.


Assuntos
Fragilidade , Transplante de Coração , Transplante de Órgãos , Consenso , Cuidados Críticos , Humanos
20.
J Card Fail ; 27(6): 700-705, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34088381

RESUMO

IMPORTANCE: Despite efforts to enhance serious illness communication, patients with advanced heart failure (HF) lack prognostic understanding. OBJECTIVES: To determine rate of concordance between HF patients' estimation of their prognosis and their physician's estimate of the patient's prognosis, and to compare patient characteristics associated with concordance. DESIGN: Cross-sectional analysis of a cluster randomized controlled trial with 24-month follow-up and analysis completed on 09/01/2020. Patients were enrolled in inpatient and outpatient settings between September 2011 to February 2016 and data collection continued until the last quarter of 2017. SETTING: Six teaching hospitals in the U.S. PARTICIPANTS: Patients with advanced HF and implantable cardioverter defibrillators (ICDs) at high risk of death. Of 537 patients in the parent study, 407 had complete data for this analysis. INTERVENTION: A multi-component communication intervention on conversations between HF clinicians and their patients regarding ICD deactivation and advance care planning. MAIN OUTCOME(S) AND MEASURE(S): Patient self-report of prognosis and physician response to the "surprise question" of 12-month prognosis. Patient-physician prognostic concordance (PPPC) measured in percentage agreement and kappa. Bivariate analyses of characteristics of patients with and without PPPC. RESULTS: Among 407 patients (mean age 62.1 years, 29.5% female, 42.4% non-white), 300 (73.7%) dyads had non-PPPC; of which 252 (84.0%) reported a prognosis >1 year when their physician estimated <1 year. Only 107 (26.3%) had PPPC with prognosis of ≤ 1 year (n=20 patients) or > 1 year (n=87 patients); (Κ = -0.20, p = 1.0). Of those with physician estimated prognosis of < 1 year, non-PPPC was more likely among patients with lower symptom burden- number and severity (both p ≤.001), without completed advance directive (p=.001). Among those with physician prognosis estimate > 1 year, no patient characteristic was associated with PPPC or non-PPPC. CONCLUSIONS AND RELEVANCE: Non-PPPC between HF patients and their physicians is high. HF patients are more optimistic than clinicians in estimating life expectancy. These data demonstrate there are opportunities to improve the quality of prognosis disclosure between patients with advanced HF and their physicians. Interventions to improve PPPC might include serious illness communication training.


Assuntos
Planejamento Antecipado de Cuidados , Desfibriladores Implantáveis , Insuficiência Cardíaca , Estudos Transversais , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA