Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Orthop Sci ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38262799

RESUMO

BACKGROUND: This study evaluated a patellar tendon shortening (PTS) surgical procedure that uses an overlapping repair combined with an additional Tycron non-absorbable suture to support the shortening in children with Cerebral Palsy (CP). This study aimed to outline this surgical technique and to evaluate its effectiveness in restoring the knee extensor mechanism. METHODS: The sagittal plane lower limb kinematics, peak knee extensor moment, gait deviation index (GDI), localised movement deviation profile (MDP), temporospatial parameters, passive knee extension ROM, quadriceps lag, and knee extensor strength were calculated pre- and postoperatively. To determine significant differences a robust linear regression model with high breakdown point and high efficiency was fitted to the data. RESULTS: In this retrospective cohort study, a total of 41 patients with CP who were treated with unilateral or bilateral PTS in isolation or as part of single event multilevel surgery (SEMLS), with a mean age of 11.1 years were included. The knee extension angle improved at initial contact (p < 0.0001), and during stance phase (p < 0.0001). The peak internal knee extensor moment decreased during early (p = 0.0014) and late stance phase (p < 0.0001). The quadriceps lag decreased (p < 0.0001) and knee extensor strength increased (p < 0.0001). The GDI improved (p < 0.0001), as well as the localised MDP for sagittal angles (p < 0.0001) and moments (p = 0.0001). Walking speed (p = 1.0) remained unchanged, but the cadence decreased (p = 0.024) and step length increased (p = 0.0001). CONCLUSIONS: The knee extension angle and moment during stance phase improved significantly. The children with CP in this study showed improvements in knee extensor strength and quadriceps lag. Thereby it can be concluded that the PTS procedure was able to restore the knee extensor mechanism effectively.

2.
Gait Posture ; 44: 68-73, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27004635

RESUMO

Normalizing clinical gait analysis data is required to remove variability due to physical characteristics such as leg length and weight. This is particularly important for children where both are associated with age. In most clinical centres conventional normalization (by mass only) is used whereas there is a stronger biomechanical argument for non-dimensional normalization. This study used data from 82 typically developing children to compare how the two schemes performed over a wide range of temporal-spatial and kinetic parameters by calculating the coefficients of determination with leg length, weight and height. 81% of the conventionally normalized parameters had a coefficient of determination above the threshold for a statistical association (p<0.05) compared to 23% of those normalized non-dimensionally. All the conventionally normalized parameters exceeding this threshold showed a reduced association with non-dimensional normalization. In conclusion, non-dimensional normalization is more effective that conventional normalization in reducing the effects of height, weight and age in a comprehensive range of temporal-spatial and kinetic parameters.


Assuntos
Marcha/fisiologia , Adolescente , Estatura/fisiologia , Peso Corporal/fisiologia , Criança , Pré-Escolar , Feminino , Humanos , Extremidade Inferior/fisiologia , Masculino , Modelos Estatísticos
3.
Gait Posture ; 40(2): 286-90, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24831115

RESUMO

Comparison of normative data between gait analysis services offers the potential to harmonise data collection protocols. This paper presents a method for such a comparison based on an assumption that the root mean square difference from the inter-service mean is a reflection of systematic differences in protocols and that the average standard deviation includes a component attributable to within-centre measurement variability. Substantial normative datasets from two highly respected clinical services were compared. The RMS difference for the difference from the inter-centre mean was less than 1.7° for all kinematic variables apart from hip rotation (2.9°) and foot progression (2.1°), less than 0.1 Nm/kg for all joint moments and than 0.21 W/kg for all joint powers. The two centres showed very similar normative standard deviations. The data demonstrates a high degree of consistency between data from two highly regarded gait analysis services and establishes a baseline against which other services can assess their performance. An electronic appendix includes data to facilitate this comparison.


Assuntos
Coleta de Dados/normas , Transtornos Neurológicos da Marcha/diagnóstico , Exame Físico/normas , Garantia da Qualidade dos Cuidados de Saúde , Fenômenos Biomecânicos , Bases de Dados Factuais/normas , Feminino , Pé/fisiologia , Marcha/fisiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Articulação do Quadril/fisiologia , Humanos , Cinética , Masculino , Modelos Estatísticos , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA