Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Chem Res Toxicol ; 25(4): 828-37, 2012 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-22263782

RESUMO

Amorphous silica nanoparticles (SiO2-NPs) have found broad applications in industry and are currently intensively studied for potential uses in medical and biomedical fields. Several studies have reported cytotoxic and inflammatory responses induced by SiO2-NPs in different cell types. The present study was designed to examine the association of oxidative stress markers with SiO2-NP induced cytotoxicity in human endothelial cells. We used pure monodisperse amorphous silica nanoparticles of two sizes (16 and 60 nm; S16 and S60) and a positive control, iron-doped nanosilica (16 nm; SFe), to study the generation of hydroxyl radicals (HO·) in cellular-free conditions and oxidative stress in cellular systems. We investigated whether SiO2-NPs could influence intracellular reduced glutathione (GSH) and oxidized glutathione (GSSG) levels, increase lipid peroxidation (malondialdehyde (MDA) and 4-hydroxyalkenal (HAE) concentrations), and up-regulate heme oxygenase-1 (HO-1) mRNA expression in the studied cells. None of the particles, except SFe, produced ROS in cell-free systems. We found significant modifications for all parameters in cells treated with SFe nanoparticles. At cytotoxic doses of S16 (40-50 µg/mL), we detected weak alterations of intracellular glutathione (4 h) and a marked induction of HO-1 mRNA (6 h). Cytotoxic doses of S60 elicited similar responses. Preincubation of cells being exposed to SiO2-NPs with an antioxidant (5 mM N-acetylcysteine, NAC) significantly reduced the cytotoxic activity of S16 and SFe (when exposed up to 25 and 50 µg/mL, respectively) but did not protect cells treated with S60. Preincubation with NAC significantly reduced HO-1 mRNA expression in cells treated with SFe but did not have any effect on HO-1 mRNA level in cell exposed to S16 and S60. Our study demonstrates that the chemical composition of the silica nanoparticles is a dominant factor in inducing oxidative stress.


Assuntos
Ferro/química , Nanopartículas/toxicidade , Estresse Oxidativo/efeitos dos fármacos , Dióxido de Silício/química , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Sistema Livre de Células , Regulação da Expressão Gênica , Glutationa/metabolismo , Heme Oxigenase-1/genética , Heme Oxigenase-1/metabolismo , Humanos , Radical Hidroxila/metabolismo , Peroxidação de Lipídeos/efeitos dos fármacos , Nanopartículas/química , Tamanho da Partícula
2.
Vet Anaesth Analg ; 38(4): 407-12, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21672129

RESUMO

OBJECTIVE: To investigate whether the method used to attach matrix-type fentanyl patches influences the degree of skin attachment and the amount of active drug remaining in patches after use. STUDY DESIGN: Prospective, randomised clinical study. STUDY POPULATION: Fifteen adult dogs of mixed breeds. METHODS: Two equally sized matrix-type fentanyl patches were attached to the dorsal third of the lateral thorax of fifteen dogs for 72 hours. The two patches were attached using different techniques: Method AD used an adhesive dressing in combination with a transparent film. Method TG used tissue adhesive applied to the edges of the patch. After 72 hours the patches were removed and the proportion of the patch attached at this time calculated. The residual content of the patches was analysed using a validated gas chromatography-mass spectrometery (GC-MS) analysis technique. RESULTS: After 72 hours of continuous attachment, the mean proportion of drug uptake for method AD was 17.2 (SD ± 11.1)% and for method TG this was 16.9 (SD ± 7.3)%. The median proportion of attachment for method AD was 100% and for method TG was 95.6%. CONCLUSIONS: The method of attachment did not significantly influence the uptake of fentanyl from matrix-type patches. The method of attachment resulted in a significant difference in the proportion of the patch attached 72 hours after placement, with method AD resulting in a greater median proportion of attachment than TG. CLINICAL RELEVANCE: The method used to attach matrix-type fentanyl patches to dogs should not interfere with drug uptake. The residual fentanyl content remaining in these patches after 72 hours of continuous application is significant and could lead to intoxication if ingested by humans.


Assuntos
Analgésicos Opioides/administração & dosagem , Cães , Fentanila/administração & dosagem , Adesivo Transdérmico/veterinária , Analgésicos Opioides/análise , Analgésicos Opioides/farmacocinética , Animais , Esquema de Medicação/veterinária , Feminino , Fentanila/análise , Fentanila/farmacocinética , Cromatografia Gasosa-Espectrometria de Massas/veterinária , Masculino , Estudos Prospectivos
3.
Artigo em Inglês | MEDLINE | ID: mdl-15081933

RESUMO

Highly sensitive and specific analytical GC-MS procedures were developed and comprehensively validated for the determination of the opioid narcotics fentanyl, sufentanil and alfentanil and their major nor-metabolites in urine of potentially exposed opioid production workers. A simple, one step extraction protocol was developed using commercially available solid phase extraction (SPE) columns to recover all analytes from urine. The secondary amine functionalities of the nor-metabolites were derivatized to form stable, pentafluorobenzamide (PFBA)-derivatives with good chromatographic properties. Using the penta-deuterated analogues as internal standards, a limit-of-detection (LOD) of 2.5 pg fentanyl/ml, 2.5 pg sufentanil/ml and 7.5 pg alfentanil/ml urine was achieved. For the opioid metabolites the LODs were found to be <50 pg/ml urine. The developed analytical procedures show excellent intra-assay accuracy, particularly considering the ultra low levels of the analytes, with relative errors generally below 10%. Overall, an excellent reproducibility was observed with coefficients of variation below 10% at all spike levels for all opioid parent compounds and their metabolites, except for low norfentanyl concentrations. Upon storage at -30 degrees C urine samples were found to be stable for at least 2 months as no significant losses of either compound were observed. The developed analytical procedures have been successfully applied in a biological monitoring survey of fentanyl exposed production workers.


Assuntos
Alfentanil/urina , Analgésicos Opioides/urina , Fentanila/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Exposição Ocupacional , Sufentanil/urina , Adulto , Calibragem , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Occup Environ Med ; 54(11): 1382-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23047657

RESUMO

OBJECTIVE: To investigate the possible impact of long-term occupational exposure to hydrocarbons on respiratory health. METHODS: Respiratory health was assessed by questionnaires, spirometry, and exhaled nitric oxide in 250 male workers from a company handling and distributing refined petroleum products (exposed) and 250 electricians (controls). Exposure to hydrocarbons was assessed by personal air monitoring. RESULTS: Aerial exposure to hydrocarbons was low. Respiratory and nasal symptoms were significantly more frequent among exposed subjects than among controls. Although forced vital capacity and forced expiratory volume in 1 second did not differ, ratio of forced expiratory volume in 1 second to forced vital capacity and maximal expiratory flows were significantly lower in exposed than in control subjects, adjusting for smoking. Exhaled nitric oxide was significantly higher among exposed subjects (30.1 ppb) than among controls (21.6 ppb), adjusting for age and smoking. CONCLUSIONS: Even low exposure to petroleum-derived hydrocarbons is associated with more respiratory and nasal symptoms, lower pulmonary function, and airway inflammation.


Assuntos
Hidrocarbonetos/efeitos adversos , Exposição por Inalação/efeitos adversos , Doenças Nasais/epidemiologia , Exposição Ocupacional/efeitos adversos , Petróleo/efeitos adversos , Transtornos Respiratórios/epidemiologia , Adulto , Argélia/epidemiologia , Testes Respiratórios , Estudos Transversais , Indústrias Extrativas e de Processamento , Volume Expiratório Forçado , Humanos , Masculino , Fluxo Expiratório Máximo , Pessoa de Meia-Idade , Óxido Nítrico/análise , Doenças Nasais/induzido quimicamente , Prevalência , Transtornos Respiratórios/induzido quimicamente , Transtornos Respiratórios/fisiopatologia , Espirometria , Inquéritos e Questionários , Fatores de Tempo , Capacidade Vital , Adulto Jovem
5.
J Clin Pharmacol ; 50(6): 667-78, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20097932

RESUMO

Delivery rates and plasma concentrations vary among patients treated with fentanyl patches. Absorption and urinary excretion characteristics of fentanyl were studied in patients undergoing palliative care. Almost 500 patches were analyzed for residual fentanyl content. Fentanyl and norfentanyl levels were determined in the urine of 50 patients. General and mixed effects linear regression models were established for the relationship between fentanyl dose rate and urinary excretion and to incorporate influencing factors. For different patch nominal dose strengths, wide but comparable variability in estimated dose rate and delivery efficiency was observed (coefficients of variation of 15% to 17%). Fentanyl delivery efficiency was 8.5% higher for patches of 25 microg/h as compared to 75 microg/h and, accordingly, 7.5% for patch application on the arm as compared to the leg. Urinary fentanyl and norfentanyl concentrations varied considerably. The general linear model revealed a positive effect of the calculated transdermal dose rate on urinary fentanyl levels, explaining 34% of the variability (P < .0001). In addition, gender (P = .04) and type of cancer pathology (P = .03) exerted significant effects on the linear model, explaining 40% and 64% of the variability, respectively. Delivery efficiency of fentanyl patches can vary substantially, possibly leading to either underdosing or overdosing.


Assuntos
Analgésicos Opioides/farmacocinética , Fentanila/farmacocinética , Dor/tratamento farmacológico , Cuidados Paliativos , Absorção Cutânea , Administração Cutânea , Adulto , Idoso , Idoso de 80 Anos ou mais , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/química , Analgésicos Opioides/urina , Doença Crônica , Relação Dose-Resposta a Droga , Portadores de Fármacos/química , Feminino , Fentanila/administração & dosagem , Fentanila/análogos & derivados , Fentanila/análise , Fentanila/urina , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/complicações , Neoplasias/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA