RESUMO
The purpose of this study was to compare the dosimetry of CG-Darc with three-dimensional conformal radiation therapy (3D CRT) and volumetric-modulated arc therapy (RapidArc) in the treatment of breast cancer with APBI. CG-Darc plans were generated using two tangential couch arcs combined with a simultaneous noncoplanar gantry arc. The dynamic couch arc was modeled by consecutive IMRT fields at 10° intervals. RapidArc plans used a single partial arc with an avoidance sector, preventing direct beam exit into the thorax. CG-Darc and RapidArc plans were compared with 3D CRT in 20 patients previously treated with 3D CRT (group A), and in 15 additional patients who failed the dosimetric constraints of the Canadian trial and of NSABP B-39/RTOG 0413 for APBI (group B). CG-Darc resulted in superior target coverage compared to 3D CRT and RapidArc (V95%: 98.2% vs. 97.1% and 95.7%). For outer breast lesions, CG-Darc and RapidArc significantly reduced the ipsilateral breast V50% by 8% in group A and 15% in group B (p < 0.05) as compared with 3D CRT. For inner and centrally located lesions, CG-Darc resulted in significant ipsilateral lung V10% reduction when compared to 3D CRT and RapidArc (10.7% vs. 12.6% and 20.7% for group A, and 15.1% vs. 25.2% and 27.3% for group B). Similar advantage was observed in the dosimetry of contralateral breast where the percent maximum dose for CG-Darc, 3D CRT, and RapidArc were 3.9%, 6.3%, and 5.8% for group A and 4.3%, 9.2%, and 6.3% for group B, respectively (p < 0.05). CG-Darc achieved superior target coverage while decreasing normal tissue dose even in patients failing APBI dose constraints. Consequently, this technique has the potential of expanding the use of APBI to patients currently ineligible for such treatment. Modification of the RapidArc algorithm will be necessary to link couch and gantry rotation with variable dose rate and, therefore, enable the use of CG-Darc in clinical practice.
Assuntos
Neoplasias da Mama/radioterapia , Posicionamento do Paciente/métodos , Radiometria , Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Dosagem RadioterapêuticaRESUMO
PURPOSE: When treatment intent is to include breast and internal mammary lymph nodes (IMNs) in the clinical target volume (CTV), a significant volume of the heart may receive radiation, which may result in late morbidity. The value of conformal intensity-modulated radiation therapy (IMRT) to avoid heart dose was studied. METHODS AND MATERIALS: Breast, IMNs, and normal tissues were contoured for 30 consecutive patients previously treated with RT after lumpectomy for left-sided breast cancer. Eleven-beam, conformal, inverse-planned IMRT plans were developed and compared with best standard plans. Conformity Index (CI), Homogeneity Index (HI), and doses to normal tissues were compared. RESULTS: Intensity-modulated RT significantly improved (two-sided paired t test) HI (0.95 vs. 0.74), CI (0.91 vs. 0.48), volume of the heart receiving more than 30 Gy (V30-heart) (1.7% vs. 12.5%), and volume of lung receiving more than 20-Gy (V20-left lung) (17.1% vs. 26.6%), all p < 0.001. The mean Healthy Tissue Volume (HTV = CT set - PTV) dose was similar between IMRT and best standard plans (6.0 and 6.9 Gy, respectively), but IMRT increased the volume of normal tissues receiving low-dose RT: V5-right lung (13.7% vs. 2.0%), V5-right breast (29.2% vs. 7.9%), and V5-HTV (31.7% vs. 23.6%), all p < 0.001. IMRT plans were generated in less than 60 min and treatment delivered in approximately 20 min, suggesting that this technique is clinically applicable. CONCLUSIONS: IMRT significantly improved conformity and homogeneity for plans when the breast + IMNs were in the CTV. Heart and lung volume receiving high doses were decreased, but more healthy tissue received low doses. A simple algorithm based on amount of heart included in the standard plan showed limited ability to predict the benefit from IMRT.
Assuntos
Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Linfonodos , Lesões por Radiação/prevenção & controleRESUMO
The purpose of this study was to determine the optimum beam number and orientation for inverse-planned, dynamic intensity-modulated radiation therapy (IMRT) for treatment of left-sided breast cancer and internal mammary nodes (IMNs) to improve target coverage while reducing cardiac and ipsilateral lung irradiation. Computed tomography (CT) data was used from 5 patients with left-sided breast cancer in whom the heart was close to the chest wall. The planning target volume (PTV) was the full breast plus ipsilateral IMNs. Two geometric beam arrangements were investigated, 240 degrees and 190 degrees sector angles, and the number of beams was increased from 7 to 9 to 11. Dose comparison metrics included: PTV homogeneity and conformity indices (HI, CI), heart V30, left lung V20, and mean doses to surrounding structures. To assess clinical application, the IMRT plans with 11 beams equally spaced in a 190 degrees sector angle were compared to conventional plans. Treatment times were modeled. The 190 degrees IMRT plans improved PTV HI and CI and reduced mean dose to the heart, lungs, contralateral breast, and total healthy tissue (all p < 0.05) compared to a 240 degrees sector angle. The 11-beam plan significantly improved PTV HI and CI, heart V30, left lung V20, and healthy tissue V5 compared to a 7-beam plan (all p < 0.05). The 11-beam plan reduced heart V30 and left lung V20 (p < 0.05) without compromising PTV coverage, compared to a 9-beam plan. Compared to a conventional plan, the IMRT class solution significantly improved PTV HI and CI (both p < 0.01), heart V30 (p = 0.01), and marginally reduced left lung V20 (p = 0.07) but increased contralateral breast and lung mean dose (p < 0.001) and healthy tissue V5 (p < 0.001). An 11-beam 190 degrees sector angle IMRT technique as a class solution is clinically feasible.
Assuntos
Neoplasias da Mama/radioterapia , Linfonodos/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Feminino , HumanosRESUMO
Dosimetric properties of an amorphous silicon electronic portal imaging device (EPID) for verification of dynamic intensity modulated radiation therapy (IMRT) delivery were investigated. The EPID was utilized with continuous frame-averaging during the beam delivery. Properties studied included effect of buildup, dose linearity, field size response, sampling of rapid multileaf collimator (MLC) leaf speeds, response to dose-rate fluctuations, memory effect, and reproducibility. The dependence of response on EPID calibration and a dead time in image frame acquisition occurring every 64 frames were measured. EPID measurements were also compared to ion chamber and film for open and wedged static fields and IMRT fields. The EPID was linear with dose and dose rate, and response to MLC leaf speeds up to 2.5 cm s(-1) was found to be linear. A field size dependent response of up to 5% relative to dmax ion-chamber measurement was found. Reproducibility was within 0.8% (1 standard deviation) for an IMRT delivery recorded at intervals over a period of one month. The dead time in frame acquisition resulted in errors in the EPID that increased with leaf speed and were over 20% for a 1 cm leaf gap moving at 1.0 cm s(-1). The EPID measurements were also found to depend on the input beam profile utilized for EPID flood-field calibration. The EPID shows promise as a device for verification of IMRT, the major limitation currently being due to dead-time in frame acquisition.
Assuntos
Análise de Falha de Equipamento , Radiometria/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia Conformacional/instrumentação , Silício/efeitos da radiação , Calibragem , Radiometria/métodos , Radiometria/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Conformacional/métodos , Radioterapia Conformacional/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Raios XRESUMO
PURPOSE: Volumetric modulated arc therapy (VMAT) is a novel extension of conventional intensity-modulated radiotherapy (cIMRT), in which an optimized three-dimensional dose distribution may be delivered in a single gantry rotation. VMAT is the predecessor to RapidArc (Varian Medical System). This study compared VMAT with cIMRT and with conventional modified wide-tangent (MWT) techniques for locoregional radiotherapy for left-sided breast cancer, including internal mammary nodes. METHODS AND MATERIALS: Therapy for 5 patients previously treated with 50 Gy/25 fractions using nine-field cIMRT was replanned with VMAT and MWT. Comparative endpoints were planning target volume (PTV) dose homogeneity, doses to surrounding structures, number of monitor units, and treatment delivery time. RESULTS: For VMAT, two 190 degrees arcs with 2-cm overlapping jaws were required to optimize over the large treatment volumes. Treatment plans generated using VMAT optimization resulted in PTV homogeneity similar to that of cIMRT and MWT. The average heart volumes receiving >30 Gy for VMAT, cIMRT, and MWT were 2.6% +/- 0.7%, 3.5% +/- 0.8%, and 16.4% +/- 4.3%, respectively, and the average ipsilateral lung volumes receiving >20 Gy were 16.9% +/- 1.1%, 17.3% +/- 0.9%, and 37.3% +/- 7.2%, respectively. The average mean dose to the contralateral medial breast was 3.2 +/- 0.6 Gy for VMAT, 4.3 +/- 0.4 Gy for cIMRT, and 4.4 +/- 4.7 Gy for MWT. The healthy tissue volume percentages receiving 5 Gy were significantly larger with VMAT (33.1% +/- 2.1%) and IMRT (45.3% +/- 3.1%) than with MWT (19.4% +/- 3.7%). VMAT reduced the number of monitor units by 30% and the treatment time by 55% compared with cIMRT. CONCLUSIONS: VMAT achieved similar PTV coverage and sparing of organs at risk, with fewer monitor units and shorter delivery time than cIMRT.