RESUMO
Background: The purpose of this study was to describe the use of the VIPER software for patient-specific quality assurance (PSQA) of single-isocenter multitarget (SIMT) stereotactic radiosurgery (SRS) plans. Materials and methods: Twenty clinical of intensity-modulated (IMRT) SIMT SRS plans were reviewed. A total of 88 brain metastases were included. Number of lesions per plan and their individual volumes ranged from 2 to 35 and from 0.03 to 32.8 cm3, respectively. Plans were designed with the Eclipse system, and delivered using a Varian CLINAC linac. SRS technique consisted of non-coplanar static-field sliding-window IMRT. Each plan was mapped onto a virtual cylindrical water phantom (VCP) in the Eclipse to calculate a 3D dose distribution (verification plan). The VIPER software reconstructed the 3D dose distribution inside the VCP from the acquired in-air electronic portal image device (EPID) images of the treatment fields. A 3D gamma analysis was used to compare the reconstructed doses to the Eclipse planned doses on the VCP. Gamma passing rates (GPRs) were calculated using 3% global/2 mm criteria and dose thresholds ranged from 10% to 90% of the maximum dose. Results: The averages (± 1 SD) of the 3D GPRs over the 20 SRS plans were: 99.9 ± 0.2%, 99.7 ± 0.3%, 99.6 ± 0.5%, 99.3 ± 0.9%,99.1 ± 1.6%, 99.0 ± 1.6%, and 98.5 ± 3.3%, for dose thresholds of 10%, 20%, 30%, 50%, 70%, 80% and 90% respectively. Conclusions: This work shows the feasibility of the VIPER software for PSQA of SIMT SRS plans, being a reliable alternative to commercially available 2D detector arrays.
RESUMO
INTRODUCTION: The aim of this study was to assess the results of the local pre-treatment verifications of online adaptive prostate SBRT plans performed by dosimetrists METHODS AND MATERIALS: Prostate SBRT treatments are planned in our department using an online adaptive method developed and validated by our group. The adaptive plans were computed on the daily CBCT scan using the Acuros XB v. 16.1 algorithm of the Varian Eclipse treatment planning system. Adaptive plans consisted of a single VMAT with 6 MV flattening-filter-free (FFF) energy performed on a Varian TrueBeam linac. Pre-treatment verification of the adaptive "plan-of-the-day" (POD) created in each treatment session was performed using the Mobius 3D v. 3.1 secondary dose calculation program (M3D). Commissioning of M3D included the tuning of the dosimetric leaf gap correction (DLGc) parameter. Generic and specific DLGc values were then derived using a set of plans for typical sites (prostate, head and neck, brain, lung and bone palliative) and another set were determined for specific online SBRT PODs (gDLGc and sDLGc, respectively). The first 50 prostate patients treated with the PACE-B schedule (5 × 7.25 Gy) were included, i.e., 250 adaptive SBRT PODs were collected in this study. For each online adaptive POD, a global 3D gamma comparison between the Eclipse 3D dose and the M3D dose in the patient CBCT was performed. Gamma passing rates (GPRs) for the whole external patient contour (Body) and the PTV were recorded, using the 5 % global /3 mm criteria. The target mean dose and target coverage differences between the Eclipse and M3D doses were also analyzed (ΔDmean and ΔD90 %, respectively). The accuracy of M3D was assessed against PRIMO Monte Carlo software. Twenty-five online prostate SBRT PODs were randomly selected from the set of 250 adaptive plans and simulated with PRIMO. RESULTS: Values of -1 mm and -0.14 mm were found as optimal gDLGc and sDLGc, respectively. Over the 250 online adaptive PODs, excellent GPR values â¼ 100 % were obtained for the Body and PTV structures, regardless the type of DLGc used. The use of the sDLGc instead of the gDLGc provided better results for ΔDmean (0.1 % ± 0.5% vs. -1.9 ± 0.7 %) and ΔD90 % (-1.0 % ± 0.5 %. vs. -3.5 % ± 0.8 %). This issue was also observed when M3D calculations were compared to PRIMO simulations. CONCLUSIONS: M3D can be effectively used for independent pre-treatment verifications of online adaptive prostate SBRT plans. The use of a specific DLGc value is advised for this SBRT online adaptive technique.
RESUMO
PURPOSE: To investigate the feasibility of using the free PRIMO Monte Carlo software for independent dose check of cranial SRS plans designed with the Varian HyperArc (HA) technique. MATERIALS AND METHODS: In this study, the PRIMO Monte Carlo software v. 0.3.64.1800 was used with the phase-space files (v. 2, Feb. 27, 2013) provided by Varian for 6 MV flattening-filter-free (FFF) photon beams from a Varian TrueBeam linear accelerator (linac), equipped with a Millennium 120 multileaf collimator (MLC). This configuration was validated by comparing the percentage depth doses (PDDs), lateral profiles and relative output factors (OFs) simulated in a water phantom against measurements for field sizes from 1 × 1 to 40 × 40 cm2. The agreement between simulated and experimental relative dose curves was evaluated using a global (G) gamma index analysis. In addition, the accuracy of PRIMO to model the MLC was investigated (dosimetric leaf gap, tongue and groove, leaf transmission and interleaf leakage). Thirty-five HA SRS plans computed in the Eclipse treatment planning system (TPS) were simulated in PRIMO. The Acuros XB algorithm v. 16.10 (dose to medium) was used in Eclipse. Sixty targets with diameters ranging from 6 to 33 mm were included. Agreement between the dose distributions given by Eclipse and PRIMO was evaluated in terms of 3D global gamma passing rates (GPRs) for the 2 %/2 mm criteria. RESULTS: Average GPR greater than 95 % with the 2 %(G)/1 mm criteria were obtained over the PDD and profiles of each field size. Differences between PRIMO calculated and measured OFs were within 0.5 % in all fields, except for the 1 × 1 cm2 with a discrepancy of 1.5 %. Regarding the MLC modeling in PRIMO, an agreement within 3 % was achieved between calculated and experimental doses. Excellent agreement between PRIMO and Eclipse was found for the 35 HA plans. The 3D global GPRs (2 %/2 mm) for the targets and external patient contour were 99.6 % ± 1.1 % and 99.8 % ± 0.5 %, respectively. CONCLUSIONS: According to the results described in this study, the PRIMO Monte Carlo software, in conjunction with the 6X FFF Varian phase-space files, can be used as secondary dose calculation software to check stereotactic radiosurgery plans from Eclipse using the HyperArc technique.