1.
Med Phys ; 35(1): 13-24, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18293556

RESUMO

The effect of the energy dispersion of a quasi-monochromatic x-ray beam on the performance of a dual-energy x-ray imaging system is studied by means of Monte Carlo simulations using MCNPX (Monte Carlo N-Particle eXtended) version 2.6.0. In particular, the case of subtraction imaging at the iodine K-edge, suitable for angiographic imaging application, is investigated. The average energies of the two beams bracketing the iodine K-edge are set to the values of 31.2 and 35.6 keV corresponding to the ones obtained with a compact source based on a conventional x-ray tube and a mosaic crystal monochromator. The energy dispersion of the two beams is varied between 0 and 10 keV of full width at half-maximum (FWHM). The signal and signal-to-noise ratio produced in the simulated images by iodine-filled cavities (simulating patient vessels) drilled in a PMMA phantom are studied as a function of the x-ray energy dispersion. The obtained results show that, for the considered energy separation of 4.4 keV, no dramatic deterioration of the image quality is observed with increasing x-ray energy dispersion up to a FWHM of about 2.35 keV. The case of different beam energies is also investigated by means of fast simulations of the phantom absorption.


Assuntos
Angiografia Digital/métodos , Iodo/química , Método de Monte Carlo , Simulação por Computador , Elétrons , Humanos , Imagens de Fantasmas , Fótons , Raios X
2.
Med Phys ; 32(12): 3755-66, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16475775

RESUMO

Dual-energy mammographic imaging experimental tests have been performed using a compact dichromatic imaging system based on a conventional x-ray tube, a mosaic crystal, and a 384-strip silicon detector equipped with full-custom electronics with single photon counting capability. For simulating mammal tissue, a three-component phantom, made of Plexiglass, polyethylene, and water, has been used. Images have been collected with three different pairs of x-ray energies: 16-32 keV, 18-36 keV, and 20-40 keV. A Monte Carlo simulation of the experiment has also been carried out using the MCNP-4C transport code. The Alvarez-Macovski algorithm has been applied both to experimental and simulated data to remove the contrast between two of the phantom materials so as to enhance the visibility of the third one.


Assuntos
Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Silício , Algoritmos , Fenômenos Biofísicos , Biofísica , Feminino , Humanos , Mamografia/estatística & dados numéricos , Método de Monte Carlo , Imagens de Fantasmas/estatística & dados numéricos
3.
Phys Med Biol ; 49(14): 3291-305, 2004 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-15357198

RESUMO

This work proposes a compact dichromatic imaging system for the application of the K-edge digital subtraction technique based on a conventional x-ray tube and a monochromator system. A quasi-monochromatic x-ray beam at the energy of iodine K-edge is produced by Bragg diffraction on a mosaic crystal. Two thin adjacent beams with energies that bracket the K-edge discontinuity are obtained from the diffracted beam by means of a proper collimation system. They are then detected using an array of Si detectors. A home-made phantom is used to study the image quality as a function of iodine concentration. Signal and signal-to-noise ratio analysis has also been performed. The results are compared with theoretical expectations.


Assuntos
Angiografia Digital/métodos , Silício/química , Raios X , Meios de Contraste , Cristalização , Humanos , Processamento de Imagem Assistida por Computador , Iodo/farmacologia , Modelos Estatísticos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Técnica de Subtração , Tecnologia Radiológica , Tomografia Computadorizada por Raios X , Água