Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
1.
Anal Chem ; 96(15): 6030-6036, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38569068

RESUMO

Cysteine (Cys), as one of the biological thiols, is related to many physiological and pathological processes in humans and plants. Therefore, it is necessary to develop a sensitive and selective method for the detection and imaging of Cys in biological organisms. In this work, a novel near-infrared (NIR) fluorescent probe, Probe-Cys, was designed by connecting furancarbonyl, as a new recognition moiety, with Fluorophore-OH via the decomposition of IR-806. The use of the furan moiety is anticipated to produce more effective fluorescence quenching because of the electron-donating ability of the O atom. Probe-Cys has outstanding properties, such as a new recognition group, an emission wavelength in the infrared region at 710 nm, a linear range (0-100 µM), a low detection limit of 0.035 µM, good water solubility, excellent sensitivity, and selectivity without the interference of Hcy, GSH, and HS-. More importantly, Probe-Cys could achieve the detection of endogenous Cys by reacting with the stimulant 1,4-dimercaptothreitol (DTT) and the inhibitor N-ethylmaleimide (NEM) in HepG2 cells and zebrafish. Ultimately, it was successfully applied to obtain images of Arabidopsis thaliana, revealing that the content of Cys in the meristematic zone was higher than that in the elongation zone, which was the first time that the NIR fluorescence probe was used to obtain images of Cys in A. thaliana. The superior properties of the probe exhibit its great potential for use in biosystems to explore the physiological and pathological processes associated with Cys.


Assuntos
Arabidopsis , Perciformes , Humanos , Animais , Fluorescência , Peixe-Zebra , Cisteína , Células HeLa , Corantes Fluorescentes , Glutationa
2.
Anal Chem ; 96(1): 446-454, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38124437

RESUMO

Histidine (His) and its metabolite analysis is significant due to their vital roles in the diagnosis of diseases. In practical applications, simple and effective detection and discrimination of these metabolic species are still a great challenge due to their highly similar structures. Herein, photoluminescence (PL)-electrochemiluminescence (ECL) dual-mode sensor arrays consisting of a series of sensing elements were proposed for simultaneous quantitation and accurate discrimination of His and its four key metabolites (including histamine, imidazole-4-acetic acid, N-acetylhistamine, and imidazole propionate). The sensing elements of these sensor arrays were constructed by employing two solvent iridium(III) complexes ([Ir(pbz)2(DMSO)Cl] and [Ir(ppy)2(DMSO)Cl], pbz = 3-(2-pyridyl)benzoic acid, ppy = 2-phenylpyridine) with excellent PL and ECL performances as cross-responsive sensing units. Based on diverse coordination abilities of the two complexes with the imidazole group of the five targets, PL and ECL responses of each sensing unit can be enhanced to various degrees, which generate unique fingerprint patterns for the corresponding targets. Through principal component analysis, the multifarious patterns (two-, three-, and four-element sensor arrays) can be transformed into simple visualization modes, from which His and its four key metabolites can be effectively discriminated against each other. Moreover, the quantitation of an individual metabolic species at different concentrations and the recognition of the mixtures with different ratios were also accurately achieved. Notably, His and its four key metabolites in urine can also be successfully discriminated by the as-fabricated sensor arrays, and the patients with kidney diseases can be identified clearly, providing a promising way for disease diagnosis.


Assuntos
Dimetil Sulfóxido , Histidina , Humanos , Fotometria , Medições Luminescentes
3.
Anal Chem ; 96(25): 10459-10466, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38866706

RESUMO

Exosomes, as an emerging biomarker, have exhibited remarkable promise in early cancer diagnosis. Here, a highly sensitive, selective, and automatic electrochemiluminescence (ECL) method for the detection of cancerous exosomes was developed. Specific aptamer-(EK)4 peptide-tagged magnetic beads (MBs-(EK)4-aptamer) were designed as a magnetic capture probe in which the (EK)4 peptide was used to reduce the steric binding hindrance of cancerous exosomes with a specific aptamer. One new universal ECL signal nanoprobe (CD9 Ab-PEG@SiO2ϵRu(bpy)32+) was designed and synthesized by using microporous SiO2 nanoparticles as the carrier for loading ECL reagent Ru(bpy)32+, polyethylene glycol (PEG) layer, and anticluster of differentiation 9 antibody (CD9 Ab). A "sandwich" biocomplex was formed on the surface of the magnetic capture probe after mixing the capture probe, target exosomes, and ECL signal nanoprobe, and then it was introduced into an automated ECL analyzer for rapid and automatic ECL measurement. It was found that the designed signal nanoprobe shows a 270-fold improvement in the signal-to-noise ratio than that of the ruthenium complex-labeled CD9 antibody signal probe. The relative ECL intensity was proportional to MCF-7 exosomes as a model in the range of 102 to 104 particle/µL, with a detection limit of 11 particle/µL. Furthermore, the ECL method was employed to discriminate cancerous exosomes based on fingerprint responses using the designed multiple magnetic capture probes and the universal ECL signal nanoprobe. This work demonstrates that the utilization of a designed automated ECL tactic using the MBs-(EK)4-aptamer capture probe and the CD9 Ab-PEG@SiO2ϵRu(bpy)32+ signal nanoprobe will provide a unique and robust method for the detection and discrimination of cancerous exosomes.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Eletroquímicas , Exossomos , Medições Luminescentes , Humanos , Exossomos/química , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/métodos , Medições Luminescentes/métodos , Células MCF-7 , Dióxido de Silício/química , Técnicas Biossensoriais/métodos , Tetraspanina 29/análise , Polietilenoglicóis/química
4.
Anal Bioanal Chem ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38937290

RESUMO

3-Methylhistidine (3-MeHis) is increasingly used as an indicator of muscle protein breakdown. The development of a sensitive, simple, and non-invasive method for 3-MeHis assay is important in clinical practice. Herein, a sensitive, simple, and non-invasive electrogenerated chemiluminescence (ECL) method was proposed for the quantitation of 3-MeHis in urine by using an iridium(III) solvent complex ([Ir(dfppy)2(DMSO)Cl], dfppy = 2-(2,4-difluorophenyl)pyridine, Ir-DMSO) as a signal reagent. The photoluminescence (PL) and ECL responses of Ir-DMSO to 3-MeHis were studied. The ECL intensity of Ir-DMSO was enhanced in the presence of 3-MeHis because of the coordination recognition between Ir-DMSO and the imidazole group of 3-MeHis. Based on the enhancement of ECL intensity, 3-MeHis can be sensitively detected in the range of 5 to 25 µM. The detection limit was 0.4 µM. This is the first report of an ECL method for the quantitation of 3-MeHis. Further, to investigate the feasibility of the Ir-DMSO-based ECL method in practical applications, the developed ECL method was applied for 3-MeHis assay in urine samples of 28 healthy volunteers and 2 patients. The urine samples from patients hospitalized with obesity and kidney disease and healthy individuals were distinguished by the ECL responses of Ir-DMSO. The proposed ECL method based on the coordination recognition between iridium(III) solvent complex and the imidazole group of 3-MeHis allows inexpensive, fast, non-invasive, and sensitive detection of 3-MeHis in urine, which is promising for assessing large volumes of patients for routine analysis in clinical practices.

5.
Mikrochim Acta ; 191(3): 143, 2024 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-38368295

RESUMO

An enzyme immunoassay was developed based on the coulometric measurement of immunoglobulin M (IgM) against Hantaan viruses (HTNV) by using virus-like particles (VLPs) as recognition molecules. The surface functionalization of screen-printed carbon electrodes (SPCEs) was achieved through paste-exfoliated graphene that was modified with a COOH group and a thionine mediator through supramolecular-covalent scaffolds, on SPCEs by using the binder contained in the ink. After the covalent immobilization of the antibody, the sensor was used for the sandwich enzyme immunoassay of IgM against HTNV. By using HTNV VLPs as the second recognization molecules, the resulting sensor efficiently monitored the reaction of IgM against HTNV and anti-IgM antibody with high specificity. By attaching HTNV nucleocapsid protein antibody conjugate with horseradish peroxidase (HRP) onto VLPs, the signal response of the assay was derived from the coulometric measurement of H2O2 reduction mediated by thionine on the electrode surface after the application of a potential (- 0.2 V vs. Ag/AgCl). The ratio of charges measured before or after H2O2 addition was used to quantify IgM because these charges could be used as background charges or total charges, respectively. The ratio exhibited good agreement with IgM concentration within a range 0.1 to 1000 pg mL-1, and a detection limit of 0.06 pg mL-1 was obtained. The assay demonstrated high sensitivity and specificity toward HTNV-specific IgM in serum.


Assuntos
Técnicas Biossensoriais , Grafite , Fenotiazinas , Grafite/química , Carbono/química , Imunoensaio/métodos , Técnicas Biossensoriais/métodos , Peróxido de Hidrogênio/química , Imunoglobulina M , Eletrodos
6.
Anal Chem ; 95(13): 5500-5506, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36967489

RESUMO

A label-free electrogenerated chemiluminescence (ECL) aptasensing method for highly sensitive determination of dopamine (DA) was developed based on target-induced DNA conformational change. After anti-DA specific aptamer, as molecular recognition element, was hybridized with a capture ss-DNA (complementary with the aptamer), the formed double-strand DNA (ds-DNA) was self-assembled onto the surface of a gold electrode, and then Ru(phen)32+, as ECL reagent, was intercalated into ds-DNA to form an ECL biosensing platform. In the presence of DA, DA bound with its aptamer and target-induced DNA conformational change occurred, resulting in the dissociation of ds-DNA, the release of intercalated Ru(phen)32+ from the electrode surface, and the decrease of ECL intensity. For comparison, an ECL aptamer-based biosensing method using an ECL reagent-labeled aptamer was also developed for DA assay based on target-induced DNA conformational change. Because of the increase in the amount of ECL reagent into ds-DNA over that of the single-site ECL reagent-labeled aptamer, an obvious increase of ECL intensity was found at the ds-DNA modified electrode over the aptamer modified electrode. DA can be sensitively detected with a lower detection limit of 0.05 nM in the range from 0.1 to 100 nM. With the recognition of the aptamer for DA, DA can be selectively and sensitively detected in artificial cerebrospinal fluid and serum samples without interference from common small molecules. This work demonstrates that the combination of the direct transduction of specific recognition of DA and its aptamer into an ECL signal with Ru(phen)32+ intercalated ds-DNA amplification provides a promising strategy for the development of a simple, sensitive, and selective method for DA assay, which is of great importance in neurochemical assays and clinical diagnosis.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Dopamina , Luminescência , Medições Luminescentes/métodos , DNA/química , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos
7.
Langmuir ; 39(19): 6681-6690, 2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37140168

RESUMO

The understanding of the dissolution processes of solids is important for the design and synthesis of solids in a controlled and precise manner and for predicting their fate in the aquatic environment. We report herein single-particle-based confocal laser scanning microscopy (CLSM) for tracking the dissolution surface kinetics of a single fluorescent cyclodextrin metal-organic framework (CD-MOF). As a proof of concept, CD-MOF containing fluorescein, named as CD-MOF⊃FL, was synthesized by encapsulating fluorescein into the interior of CD-MOF via a vapor diffusion method and used as a single-particle dissolution model because of its high FL efficiency and unique structure. The morphology of CD-MOF⊃FL and the distribution of fluorescein within CD-MOF⊃FL were characterized. The growth and dissolution processes of CD-MOF⊃FL at the single-particle level were visualized and quantified for the first time by recording the change of the fluorescence emission. Three processes, including nucleation, germination growth, and saturation stage, were found in the growth of CD-MOF⊃FL, and the growth kinetics followed Avrami's model. The dissolution rate at the face of a single CD-MOF⊃FL crystal was slower than that of its arris, and the dissolution rate of the CD-MOF⊃FL crystal was increased with the increase of the water amount in methanol solution. The dissolution process of the CD-MOF⊃FL crystal was a competitive process of erosion and diffusion in different methanol aqueous solutions, and the dissolution kinetics followed the Korsmeyer-Peppas model. These results offer new insights into the nature of dissolution kinetics of CD-MOF⊃FL and provide new venues for the quantitative analysis of solid dissolution and growth at the single-particle level.

8.
Analyst ; 148(24): 6253-6260, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-37937443

RESUMO

A novel point-of-care testing (POCT) method for the determination of proteases was developed for the first time using a designed disposable capillary-fill device based on the cleavage of electrogenerated chemiluminescence (ECL)-label-tagged peptide probes and enabling elimination of the light-shielding from the magnetic beads (MBs). As a proof-of-principle, prostate-specific antigen (PSA) was taken as a model analyte, and streptavidin-coated magnetic beads bound with ruthenium-complex-tagged specific peptide (biotin-HSSKLQK) were utilized as MB ECL probes. The capillary-fill device was designed to be divided into a reaction zone and detection zone. In the reaction zone, the bio-cleavage reaction between the PSA analyte with the peptide on the surface of the MB ECL probes occurred, while in the detection zone, ECL emission was produced by a screen-printed carbon electrode, Ag/AgCl reference electrode and carbon counter electrode. When the analyte PSA was introduced into the suspension of MB ECL probes in the reaction zone of the device, biocleavage of the peptide occurred, and the cleaved Ru1 part was released from the surface of the MB ECL probes. The capillary-filled device was tilted 90°, and with the aid of gravity, the solution containing the released Ru1 part flowed to the surface of the working electrode in the detection region of the device, while the MB ECL probes were fixed in the reaction zone by an external magnet. PSA can be determined by the ECL emission from the released Ru1 part in the presence of the co-reactant tri-n-propylamine at the detection zone. Under the optimal conditions, the developed ECL method showed a low detection limit of 0.12 ng mL-1 for PSA. This work demonstrates that the developed ECL biosensing approach can eliminate the MB light-shielding effect and quantify proteases with high sensitivity and selectivity, which could be easily extended to POCT-based ECL biosensing for other proteases.


Assuntos
Técnicas Biossensoriais , Peptídeo Hidrolases , Humanos , Masculino , Antígeno Prostático Específico , Luminescência , Peptídeos , Carbono , Medições Luminescentes/métodos , Técnicas Biossensoriais/métodos
9.
Mikrochim Acta ; 190(10): 422, 2023 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-37775573

RESUMO

An electrochemiluminescence (ECL) bioassay with high sensitivity and anti-fouling ability was developed for determination of matrix metalloproteinase 9 (MMP-9) secreted from living cells under external stimulation. A peptide with sequence of CLGRMGLPGK and a new cyclometalated iridium(III) complex bearing carboxyl group, (pq)2Ir(dcbpy) (pq = 2-phenylquinoline, dcbpy = 2,2'-bipyridyl-4,4'-dicarboxyli acid, abbreviated as Ir) were employed as molecular recognition substrate and ECL emitter, respectively. The peptide was labelled with the Ir to form Ir-peptide as ECL probe. Ir-peptide was self-assembled onto Nafion and gold nanoparticles (AuNPs) modified glassy carbon electrode (AuNPs/Nafion/GCE) and then both of 6-mercapto-1-hexanol (MCH) and zwitterionic peptide as blocking reagents were co-assembled on Ir-peptide/AuNPs/Nafion/GCE to form an anti-fouling ECL peptide-based biosensor. MMP-9 can be quantified in the range 1.0-50 ng·mL-1 with a detection limit of 0.50 ng·mL-1 based on the decreased ECL intensity. Relative standard derivation was 2.3% for six fabricated anti-fouling ECL peptide-based biosensors after reaction with 50 ng·mL-1 MMP-9. The anti-fouling ECL peptide-based biosensor can be used to monitor MMP-9 secreted from living cells under external stimulation. 96.0%-108.0% of recoveries were obtained in 60-diluted cell culture media. This study demonstrates that the ECL biosensor by the combination of iridium(III) complex-based sensitive ECL method and the anti-fouling interface provides a promising way for the determination of MMP-9 in biological sample, which is viable in clinical diagnosis and point-of-care test of protease.


Assuntos
Incrustação Biológica , Nanopartículas Metálicas , Ouro/química , Metaloproteinase 9 da Matriz , Irídio , Incrustação Biológica/prevenção & controle , Medições Luminescentes/métodos , Nanopartículas Metálicas/química , Peptídeos/química
10.
Anal Chem ; 94(4): 2305-2312, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35067054

RESUMO

This work reports a highly efficient electrogenerated chemiluminescence (ECL) quenching on lipid-coated multifunctional magnetic nanoparticles (MMNP) for the determination of proteases incorporating membrane-confined quenching with a specific cleavage reaction for the first time. A new ruthenium complex [Ru(bpy)2(ddcbpy)](PF6)2 (bpy = 2,2'-bipyridine, ddcbpy = 4,4'-didodecyl-carbonyl-2,2'-bipyridine with two hydrophobic long alkyl chains) was synthesized as a signal probe, while [cholesterol-(CH2)6-HSSKLQK(peptide)-ferrocene (quencher)] was designed as a specific peptide-quencher probe. The MMNP were prepared by inserting both the signal probe and the peptide-quencher probe into the cholesterol-phospholipid-coated Fe3O4 magnetic nanoparticles (Fe3O4 NP, ∼200 nm). When prostate specific antigen (PSA) taken as a model analyte was introduced into the suspension of MMNP, PSA cleaved the amide bond of SK in cholesterol-(CH2)6-HSSKLQK-Fc, and then the cleaved peptide-motif-Fc-quencher was deviated from the MMNP, resulting in the increase in the ECL intensity. It was found that the ECL quenching constant of [Ru(bpy)2(ddcbpy)]2+ on MMNP (KSV, NP/lipECL =2.68 × 107 M-1) is 137-folds higher than that on the lipid-coated electrode (KSV, lipECL=1.95 × 105 M-1) and 391-folds higher than that in the solution (KSV, aqECL =6.86 × 104 M-1). The ECL emission of Ru(bpy)32+ derivative-attached Fe3O4 NP was observed at ∼1.2 V, involving the tunnel-electron transfer pathway (TPA• + Ru(bpy)33+ = Ru(bpy)32+*). Based on the highly efficient ECL quenching of the ruthenium complex by ferrocene on the MMNP, a new ECL method was developed for PSA with a linear range from 0.01 to 1.0 ng/mL and a limit of detection of 3.0 pg/mL. This work demonstrates that the approach of ECL quenching by ferrocene on lipid-coated Fe3O4 NP is promising and could be easily extended to determine other proteases.


Assuntos
Técnicas Biossensoriais , Técnicas de Química Analítica , Peptídeo Hidrolases , Técnicas Biossensoriais/métodos , Técnicas de Química Analítica/métodos , Lipídeos/química , Luminescência , Medições Luminescentes/métodos , Nanopartículas de Magnetita , Peptídeo Hidrolases/análise
11.
Anal Chem ; 94(13): 5441-5449, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35311260

RESUMO

Exploring new electrochemiluminescence (ECL) luminophores with high ECL efficiency and good stability in aqueous solution is in great demand for biological sensing. In this work, highly efficient aggregation-induced enhanced ECL of cyanophenyl-functionalized tetraphenylethene (tetra[4-(4-cyanophenyl)phenyl]ethene, TCPPE) and its application in biothiols analysis were reported. TCPPE contains four 4-cyanophenyl groups covalently attached to the tetraphenylethene (TPE) core, generating a nonplanar three-dimensional twisted conformation structure. TCPPE nanoparticles (NPs) with an average size of 15.84 nm were prepared by a precipitation method. High ECL efficiency (593%, CdS as standard) and stable ECL emission (over one month) were obtained for TCPPE NPs in aqueous solution. The unique properties of TCPPE NPs could be ascribed to the efficient suppression of nonradiative transition, the decrease of the energy gap, and the increase of anionic radical stability, which were proved by theoretical calculation and electrochemical and fluorescence methods. Contrasting aggregation-induced ECL chromic emission was first observed for TCPPE NPs. As a proof-of-methodology, an ECL method was developed for three biothiol assays with detection limits of 6, 7, and 300 nM for cysteine, homocysteine, and glutathione, respectively. This work demonstrates that TCPPE NPs are promising ECL luminophores, and the incorporation of appropriate substituents into luminophores can improve ECL efficiency and radical stability.


Assuntos
Técnicas Biossensoriais , Nanopartículas , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Medições Luminescentes/métodos , Nanopartículas/química , Fotometria
12.
Analyst ; 147(15): 3444-3450, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35792747

RESUMO

Heat shock protein 70 (Hsp70), belonging to the heat shock protein (HSP) family, is reported to be a potential diagnostic biomarker. In this work, a lateral flow immunostrip was fabricated for the sensitive and rapid determination of Hsp70 by the incorporation of fluorescence and upconversion nanoparticle probes. The upconversion nanoparticles (UCNPs, size ∼39 nm, λex = 980 nm; λem = 540 nm) consisting of a NaYF4:Yb/Er core and polyacrylic acid-modified shell were covalently coupled with Hsp70 antibodies to form the signal probe, which was characterized by dynamic light scattering and zeta potential analyses. The lateral flow assay (LFA) was constructed based on the sandwich-type immunoassay using a sample pad, a test pad, and an adsorption pad on a PVP backing. Hsp70 antibody, IgG antibody and the signal probe were separately dropped on the test zone, the control zone of the test pad, and the sample pad, respectively. In the sandwich LFA, since two antibodies bind to Hsp70 antigenic epitopes, i.e. specific binding, it provided superior specificity and high sensitivity, making it an ideal sensing platform for complex samples like serum Hsp70 samples. The important parameters for the preparation of the lateral flow immunostrips were optimized. Under the optimized conditions, Hsp70 can be detected using the increased fluorescence intensity of UCNPs with a wide linear range from 0.11 to 12 ng mL-1, low detection limit of 0.06 ng mL-1, small sample volume (120 µL), short assay time (15 min) and good reproducibility. The fluorescence method was successfully applied in the determination of Hsp70 in serum samples with good recovery. By combining the accessibility of the lateral flow immunostrips and upconversion nanoparticles, the fluorescence method can serve as a point-of-care testing method for protein assays with high sensitivity and fast detection.


Assuntos
Corantes Fluorescentes , Nanopartículas , Anticorpos , Proteínas de Choque Térmico HSP70 , Imunoensaio/métodos , Nanopartículas/química , Reprodutibilidade dos Testes
13.
Anal Chem ; 93(49): 16683-16689, 2021 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-34860503

RESUMO

We report a self-terminated electroless deposition method to prepare surfactant-free and monodispersed Pt nanoparticle (NP)-modified carbon fiber microelectrodes (Pt NP/CFEs) for electrochemical detection of hydrogen peroxide (H2O2) released from living cells. The surfactant-free and monodispersed Pt NPs with a uniform size of 65 nm are spontaneously deposited on a CFE surface by immersing an exposed carbon fiber (CF) of CFE in the PtCl42- solution, in which an exposed CF can be used as the reducing agent and stabilizer. A self-terminated electroless deposition method is demonstrated, in which the density and size of Pt NPs on a CFE surface do not increase when the reaction time increases from 20 to 60 min. The self-terminated electroless deposition process not only can effectively avoid any manual electrode modification and thus largely minimize person-to-person and electrode-to-electrode deviations but also can avoid the use of any extra reductant or surfactant in the fabrication process. Therefore, Pt NPs/CFEs, with good reproducibility and sensitivity, not only exhibit high electrocatalytic activity toward the oxidation of H2O2 but also maintain the spatial resolution of CFEs. Moreover, Pt NPs/CFEs can detect H2O2 with a wide linear range of 0.5-80 µM and a low detection limit of 0.17 µM and then can be successfully applied in the monitoring of H2O2 released from RAW 264.7 cells. The self-terminated electroless deposition method can also be extended to selectively prepare other metal NP-modified CFEs, such as Au NPs/CFEs or Ag NPs/CFEs, by choosing the metal ions with higher reduction potential as precursors. This work provides a simple, straightforward, and general method for the preparation of small, surfactant-free, and monodispersed metal NP-modified CFEs with high sensitivity, reproducibility, and spatial resolution.


Assuntos
Peróxido de Hidrogênio , Nanopartículas Metálicas , Fibra de Carbono , Humanos , Microeletrodos , Reprodutibilidade dos Testes , Tensoativos
14.
Anal Chem ; 92(1): 524-534, 2020 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-31789502

RESUMO

This Feature simply introduces the history and mechanism of classical electrogenerated chemiluminescence (ECL) systems for the detection of biomolecules, highlights new advances and emerging fields of the ECL biosensing with recent illustrative examples, and presents the challenges and perspectives of ECL biosensing.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Luminescência , Medições Luminescentes , Animais , Humanos
15.
Anal Chem ; 92(16): 10940-10945, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32700526

RESUMO

Monitoring the fluctuation of adenosine 5'-triphosphate (ATP) at the subcellular level is important for the study of cell energy metabolism. Herein, we fabricated an electrochemical nanoaptasensor for continuously monitoring ATP fluctuation at the subcellular level. A gold nanoelectrode with a diameter of 120 nm was fabricated, and ferrocene (Fc)-labeled anti-ATP aptamer was self-assembled onto the nanoelectrode surface to form a nanoaptasensor. In the presence of ATP, the ferrocene-labeled anti-ATP aptamer bound with two ATP units to form an ATP-aptamer conjugation, resulting in the close proximity of Fc to the nanoelectrode surface and then an increase of oxidation current of Fc. ATP can be detected with a detection limit of 26 µM within 2 min. Cell viability assays indicated that the nanoaptasensor was biocompatible with negligible biological effects. By taking advantage of the good biocompatibility of the nanoaptasensor, ATP fluctuation at the subcellular level was monitored under glucose starvation and Ca2+ induction. This work demonstrates that the nanoaptasensor is a useful tool for investigating ATP-relevant biological processes via the electrochemical method.


Assuntos
Trifosfato de Adenosina/análise , Trifosfato de Adenosina/metabolismo , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Trifosfato de Adenosina/química , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Cálcio/metabolismo , Técnicas Eletroquímicas/instrumentação , Eletrodos , Metabolismo Energético/fisiologia , Compostos Ferrosos/química , Glucose/metabolismo , Ouro/química , Células HeLa , Humanos , Limite de Detecção , Metalocenos/química
16.
Anal Chem ; 92(24): 15837-15844, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33269595

RESUMO

This work reports a gold nanoelectrode ensembles (Au-NEE) platform taken as a disposable electrogenerated chemiluminescence (ECL) platform with immunomagnetic microbeads for ECL immunoassays for the first time. The peak-shaped voltammograms were obtained at the Au-NEE, attributed to the total diffusional overlap. The ECL intensity at Au-NEE was 12.9 folds in the Ru(bpy)32+-tri-n-propylamine (TPA) ECL system and 19.6 folds in the luminol-H2O2 system, compared with that at the Au macroelectrode using the normalized active area of the electrodes, mainly attributed to the diffusion overlap of the Au-NEE and the edge effect of the individual gold nanodisks of the Au-NEE. The ECL immunoassay on the Au-NEE platform with magnetic microbeads for the determination of cancer biomarkers was developed. Carbohydrate antigen 19-9 (CA 19-9) was chosen as a model analyte while CA 19-9 antibody on the magnetic microbeads was taken as the capture probe, and ruthenium complex-labeled CA 19-9 antibody was used as the signal probe. A "sandwich" bioconjugates on the magnetic beads were transferred onto the ECL platform, and then the ECL measurements were performed in TPA solution. The developed method showed that the ECL peak intensity was directly in proportion to the concentration of CA 19-9 in the range from 0.5 to 20 U/mL with a limit of detection of 0.4 U/mL. This work demonstrates that the Au-NEE can be employed as a useful disposable ECL platform with the merits of cheapness, low nonspecific adsorption and practical application. The proposed approach will open a new avenue in the point-of-care test for the determination of protein biomarkers.


Assuntos
Antígenos Glicosídicos Associados a Tumores/análise , Técnicas Biossensoriais , Ouro/química , Imunoensaio , Medições Luminescentes , Nanopartículas Metálicas/química , Eletrodos , Humanos , Campos Magnéticos , Tamanho da Partícula , Propriedades de Superfície
17.
Anal Chem ; 92(12): 8278-8284, 2020 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-32458679

RESUMO

In this work, a simple electrochemiluminescence (ECL) imaging method based on the cell shield of the ECL emission was developed for the morphological and quantitative analysis of living cells under external stimulation. ECL images of MCF-7 cells cultured on or captured at the glassy carbon electrode (GCE) surface in a solution of tris(2,2'-bipyridyl)ruthenium(II)-tri-n-propylamine were recorded. Important morphological characteristics of living cells, including cell shape, cell area, average cell boundary, and junction distance between two adjacent cells, were directly obtained using the developed negative ECL imaging method. The ECL images revealed gradual morphological changes in cells on the GCE surface. During the course of H2O2 stimulation of cells on the GCE surface, cells shrunk, rounded up, disengaged from surrounding cells, and finally detached from the electrode surface. During the course of electrical stimulation (0.8 V), the cells on the GCE surface exhibited aggregation as demonstrated by increases in the average cell boundary and decreases in the junction distance between two adjacent cells. Additionally, a quantitative method for the sensitive determination of MCF-7 cells with a limit of detection of 29 cells/mL was developed using the negative ECL imaging strategy. This work demonstrates that the proposed negative ECL imaging strategy is a promising approach to assess important morphological characteristics of living cells during the course of external stimulation and to obtain quantitative information on cell concentrations in solution.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas Eletroquímicas , Peróxido de Hidrogênio/química , Medições Luminescentes , Imagem Óptica , Carbono/química , Eletrodos , Humanos , Células MCF-7 , Tamanho da Partícula , Propriedades de Superfície , Células Tumorais Cultivadas
18.
Anal Chem ; 92(1): 884-891, 2020 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-31808341

RESUMO

A separation-free electrogenerated chemiluminescence (ECL) immunoassay for biomarkers has been developed incorporating target assistant proximity hybridization and dynamically competitive hybridization of a DNA ECL signal probe for the first time. In this work, the biomarkers of acute myocardial infarction including cardiac troponin I (cTnI), cardiac troponin T (cTnT), and myoglobin (Myo) were chosen as the model proteins while the corresponding antibody was utilized as a recognition probe and the DNA5 tagged with ruthenium complex was chosen as an ECL signal probe (DNA5-Ru1). The biosensors were fabricated by covalently coupling the capture probe DNA1 onto the surface of a glassy carbon electrode, and then, a competitor ss-DNA2 was hybridized with DNA1. When the biosensor was incubated in the solution containing a target protein, the recognition probes (DNA3-Ab1 and DNA4-Ab2), DNA5-Ru1, and the coreactant tri-n-propylamine, the target protein was bounded with two antibodies of the recognition probes and thus induced the sufficient proximity hybridization of DNA3 with DNA1, DNA4 with DNA5-Ru1, and DNA5-Ru1 with DNA1 and the unwinding of the competitor DNA2 with DNA1, and ECL measurement was performed in separation-free format. It was found that the hybridization base number and length of DNA1 and a competing hybridization of DNA5-Ru1 with DNA2 for DNA1 have important effects. The developed ECL method showed a quite low detection limit of 0.4 pg/mL for cTnI, 0.5 pg/mL for cTnT, and 0.5 ng/mL for Myo. The fabricated biosensor exhibited stability and reusability. This work demonstrated that the developed ECL immunoassay is a promising separation-free and flexible strategy for quantitation of multiple proteins using one biosensor.


Assuntos
Técnicas Biossensoriais/métodos , Sondas de DNA/química , Mioglobina/sangue , Troponina I/sangue , Animais , Anticorpos Imobilizados/química , Técnicas Eletroquímicas/métodos , Humanos , Ácidos Nucleicos Imobilizados/química , Imunoensaio/métodos , Limite de Detecção , Medições Luminescentes/métodos , Camundongos , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Mioglobina/análise , Hibridização de Ácido Nucleico , Rutênio/química , Troponina I/análise
19.
Nanotechnology ; 31(13): 135503, 2020 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-31825903

RESUMO

We report a facile strategy for the synthesis of surfactant-free, small and highly dispersive Pt-Pd nanoparticles on graphene oxide (Pt-Pd NPs/GO) by an electroless deposition method, which is sheathed on carbon fiber microelectrodes (CFMs) as an electrochemical sensing platform for highly sensitive and selective detection of hydrogen peroxide (H2O2) released from the living cells. GO serves as the reducing agent and stabilizer for electroless deposition of Pd NPs on the surface of GO owing to its low work function (4.38 eV) and highly conjugated electronic structure. The obtained Pd NPs/GO have a relatively high work function (4.64 eV), and thereby could be used as stabilizer for synthesis of surfactant-free, small and highly dispersive Pt-Pd NPs/GO by chemical reduction of K2PtCl4. The obtained Pt-Pd NPs have a uniform size of 4.0 ± 0.6 nm on the surface of GO. Moreover, the Pt-Pd NPs/GO sheathed CFMs exhibit an excellent electrocatalytic activity for the reduction of H2O2 with a low detection limit of 0.3 µM and good selectivity. These good properties enable the modified microelectrode to detect the H2O2 released from living cells.


Assuntos
Fibra de Carbono/química , Grafite/química , Peróxido de Hidrogênio/análise , Platina/química , Técnicas Biossensoriais , Limite de Detecção , Nanopartículas Metálicas , Microeletrodos , Microscopia Eletrônica de Transmissão , Nanocompostos/química
20.
Nanotechnology ; 31(24): 245001, 2020 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-32109887

RESUMO

Multiple-color emissive carbon dots (C-dots) are gaining increasing attention in various fields. Herein, we report a facile solvothermal method for the synthesis of multiple-color emissive C-dots with the aim of white-light emission. Under single ultraviolet-light excitation, three C-dots emit a easily controlled fluorescent emission wavelength at 440 nm, 500 nm and 610 nm by using different three amines (either ammonium hydroxide, ethylenediamine or p-phenylenediamine, respectively) and pyromellitic dianhydride as molecular precursors while another three C-dots emit a controllable fluorescent emission wavelength at 500 nm, 550 nm and 585 nm by using same three amines and naphthalene-1,4,5,8-tetracarboxylic dianhydride as molecular precursors. The maximum fluorescence wavelength of these C-dots is red-shifted by changing three different amines molecular precursors from ammonium hydroxide, ethylenediamine, to p-phenylenediamine. Furthermore, these C-dots have shown promising applications in the fields of white-light-emitting diodes devices and color printing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA