1.
Med Phys ; 35(1): 13-24, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18293556

RESUMO

The effect of the energy dispersion of a quasi-monochromatic x-ray beam on the performance of a dual-energy x-ray imaging system is studied by means of Monte Carlo simulations using MCNPX (Monte Carlo N-Particle eXtended) version 2.6.0. In particular, the case of subtraction imaging at the iodine K-edge, suitable for angiographic imaging application, is investigated. The average energies of the two beams bracketing the iodine K-edge are set to the values of 31.2 and 35.6 keV corresponding to the ones obtained with a compact source based on a conventional x-ray tube and a mosaic crystal monochromator. The energy dispersion of the two beams is varied between 0 and 10 keV of full width at half-maximum (FWHM). The signal and signal-to-noise ratio produced in the simulated images by iodine-filled cavities (simulating patient vessels) drilled in a PMMA phantom are studied as a function of the x-ray energy dispersion. The obtained results show that, for the considered energy separation of 4.4 keV, no dramatic deterioration of the image quality is observed with increasing x-ray energy dispersion up to a FWHM of about 2.35 keV. The case of different beam energies is also investigated by means of fast simulations of the phantom absorption.


Assuntos
Angiografia Digital/métodos , Iodo/química , Método de Monte Carlo , Simulação por Computador , Elétrons , Humanos , Imagens de Fantasmas , Fótons , Raios X
2.
Med Phys ; 32(12): 3755-66, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16475775

RESUMO

Dual-energy mammographic imaging experimental tests have been performed using a compact dichromatic imaging system based on a conventional x-ray tube, a mosaic crystal, and a 384-strip silicon detector equipped with full-custom electronics with single photon counting capability. For simulating mammal tissue, a three-component phantom, made of Plexiglass, polyethylene, and water, has been used. Images have been collected with three different pairs of x-ray energies: 16-32 keV, 18-36 keV, and 20-40 keV. A Monte Carlo simulation of the experiment has also been carried out using the MCNP-4C transport code. The Alvarez-Macovski algorithm has been applied both to experimental and simulated data to remove the contrast between two of the phantom materials so as to enhance the visibility of the third one.


Assuntos
Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Silício , Algoritmos , Fenômenos Biofísicos , Biofísica , Feminino , Humanos , Mamografia/estatística & dados numéricos , Método de Monte Carlo , Imagens de Fantasmas/estatística & dados numéricos
3.
Methods Inf Med ; 44(2): 244-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15924184

RESUMO

OBJECTIVES: The next generation of high energy physics (HEP) experiments requires a GRID approach to a distributed computing system: the key concept is the Virtual ORGANISATION (VO), a group of distributed users with a common goal and the will to share their resources. METHODS: A similar approach, applied to a group of hospitals that joined the GPCALMA project (Grid Platform for Computer Assisted Library for MAmmography), will allow common screening programs for early diagnosis of breast and, in the future, lung cancer. The application code makes use of neural networks for the image analysis and is useful in improving the radiologists' diagnostic performance. GRID services allow remote image analysis and interactive online diagnosis, with a potential for a relevant reduction of the delays presently associated with screening programs. RESULTS AND CONCLUSIONS: A prototype of the system, based on AliEn GRID Services [1], is already available, with a central server running common services [2] and several clients connecting to it. Mammograms can be acquired in any location; the related information required to select and access them at any time is stored in a common service called Data Catalogue, which can be queried by any client. Thanks to the PROOF facility [3], the result of a query can be used as input for analysis algorithms, which are executed on the nodes where the input images are stored,. The selected approach avoids data transfers for all the images with a negative diagnosis and allows an almost real time diagnosis for the set of images with high cancer probability.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Internet/instrumentação , Mamografia , Sistemas de Informação em Radiologia/instrumentação , Integração de Sistemas , Telerradiologia/instrumentação , Algoritmos , Sistemas de Gerenciamento de Base de Dados , Bases de Dados Factuais , Diagnóstico por Computador , Europa (Continente) , Feminino , Humanos , Internacionalidade , Itália , Sistemas Computadorizados de Registros Médicos , Desenvolvimento de Programas , Interface Usuário-Computador
4.
Phys Med Biol ; 49(14): 3291-305, 2004 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-15357198

RESUMO

This work proposes a compact dichromatic imaging system for the application of the K-edge digital subtraction technique based on a conventional x-ray tube and a monochromator system. A quasi-monochromatic x-ray beam at the energy of iodine K-edge is produced by Bragg diffraction on a mosaic crystal. Two thin adjacent beams with energies that bracket the K-edge discontinuity are obtained from the diffracted beam by means of a proper collimation system. They are then detected using an array of Si detectors. A home-made phantom is used to study the image quality as a function of iodine concentration. Signal and signal-to-noise ratio analysis has also been performed. The results are compared with theoretical expectations.


Assuntos
Angiografia Digital/métodos , Silício/química , Raios X , Meios de Contraste , Cristalização , Humanos , Processamento de Imagem Assistida por Computador , Iodo/farmacologia , Modelos Estatísticos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Técnica de Subtração , Tecnologia Radiológica , Tomografia Computadorizada por Raios X , Água