Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Beilstein J Org Chem ; 12: 1467-75, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27559399

RESUMO

A novel approach to protecting jet fuel against the effects of water contamination is predicated upon the coupling of the rapid hydrolysis reactions of lipophilic cyclic geminal ethers, with the concomitant production of a hydrophilic acyclic hydroxyester with de-icing properties (Fuel Dehydrating Icing Inhibitors - FDII). To this end, a kinetic appraisal of the hydrolysis reactions of representative geminal ethers was undertaken using a convenient surrogate for the fuel-water interface (D2O/CD3CN 1:4). We present here a library of acyclic and five/six-membered cyclic geminal ethers arranged according to their hydroxonium catalytic coefficients for hydrolysis, providing for the first time a framework for the development of FDII. A combination of (1)H NMR, labelling and computational studies was used to assess the effects that may govern the observed relative rates of hydrolyses.

2.
Clin Gastroenterol Hepatol ; 11(7): 868-75.e1-3, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23454028

RESUMO

BACKGROUND & AIMS: The histopathology of nonalcoholic fatty liver disease (NAFLD) is similar to that of alcoholic liver disease. Colonic bacteria are a source of many metabolic products, including ethanol and other volatile organic compounds (VOC) that may have toxic effects on the human host after intestinal absorption and delivery to the liver via the portal vein. Recent data suggest that the composition of the gut microbiota in obese human beings is different from that of healthy-weight individuals. The aim of this study was to compare the colonic microbiome and VOC metabolome of obese NAFLD patients (n = 30) with healthy controls (n = 30). METHODS: Multitag pyrosequencing was used to characterize the fecal microbiota. Fecal VOC profiles were measured by gas chromatography-mass spectrometry. RESULTS: There were statistically significant differences in liver biochemistry and metabolic parameters in NAFLD. Deep sequencing of the fecal microbiome revealed over-representation of Lactobacillus species and selected members of phylum Firmicutes (Lachnospiraceae; genera, Dorea, Robinsoniella, and Roseburia) in NAFLD patients, which was statistically significant. One member of phylum Firmicutes was under-represented significantly in the fecal microbiome of NAFLD patients (Ruminococcaceae; genus, Oscillibacter). Fecal VOC profiles of the 2 patient groups were different, with a significant increase in fecal ester compounds observed in NAFLD patients. CONCLUSIONS: A significant increase in fecal ester VOC is associated with compositional shifts in the microbiome of obese NAFLD patients. These novel bacterial metabolomic and metagenomic factors are implicated in the etiology and complications of obesity.


Assuntos
Fígado Gorduroso/patologia , Fezes/química , Fezes/microbiologia , Metaboloma , Microbiota , Obesidade/patologia , Compostos Orgânicos Voláteis/análise , Adulto , Biota , Estudos de Casos e Controles , Fígado Gorduroso/complicações , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica , Obesidade/complicações , Análise de Sequência de DNA
3.
Adv Med Sci ; 67(1): 1-9, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34562855

RESUMO

PURPOSE: Antibiotic resistance is widespread throughout the world and represents a serious health concern. There is an urgent need for the development of novel tools for rapidly distinguishing antibiotic resistant bacteria from susceptible strains. Previous work has demonstrated that differences in antimicrobial susceptibility can be reflected in differences in the profile of volatile organic compounds (VOCs) produced by dissimilar strains. The aim of this study was to investigate the effect of the presence of cephalosporin antibiotics on the VOC profile of extended spectrum beta-lactamase (ESBL) and non-ESBL producing strains of Escherichia coli. MATERIAL AND METHODS: In this study, VOCs from strains of Escherichia coli positive and negative for the most commonly encountered ESBL, CTX-M in the presence of cephalosporin antibiotics were assessed using solid-phase microextraction (SPME) coupled with a combined gas chromatography-mass spectrometry/metal oxide sensor (GC-MS/MOS) system. RESULTS: Our proof-of-concept study allowed for distinguishing CTX-M positive and negative bacteria within 2 â€‹h after the addition of antibiotics. One MOS signal (RT: 22.6) showed a statistically significant three-way interaction (p â€‹= â€‹0.033) in addition to significant two-way interactions for culture and additive (p â€‹= â€‹0.046) plus time and additive (p â€‹= â€‹0.020). There were also significant effects observed for time (p â€‹= â€‹0.009), culture (p â€‹= â€‹0.030) and additive (p â€‹= â€‹0.028). No effects were observed in the MS data. CONCLUSIONS: The results of our study showed the potential of VOC analysis using SPME combined with a GC-MS/MOS system for the early detection of CTX-M-producing, antibiotic-resistant E. coli, responsible for urinary tract infections (UTIs).


Assuntos
Escherichia coli , Infecções Urinárias , Antibacterianos/farmacologia , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Testes de Sensibilidade Microbiana , Óxidos , Microextração em Fase Sólida , Infecções Urinárias/diagnóstico , Infecções Urinárias/tratamento farmacológico , beta-Lactamases
4.
J Pediatr Gastroenterol Nutr ; 49(5): 559-65, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19668005

RESUMO

OBJECTIVE: : To determine differences in the profiles of volatile organic compounds (VOCs) in faecal samples from preterm infants who develop necrotising enterocolitis (NEC) compared with non-NEC controls. MATERIALS AND METHODS: : Daily faecal samples from preterm infants were collected prospectively during an 8-month period from a level 3 regional neonatal intensive care unit. Six infants subsequently developed NEC and were matched with 7 non-NEC infants. Solid-phase microextraction and gas chromatography and mass spectrometry were used to extract and identify the VOCs from the headspace above the faecal samples taken before the onset of NEC and after the disease was diagnosed. Faecal samples at similar ages were also studied from the control infants. RESULTS: : Two hundred twenty-four different VOCs were extracted from 65 samples. Volatile organic compounds increased in number with age for non-NEC infants. In the days before and after the diagnosis of NEC a reduction in the number of VOCs extracted was observed. In addition, 4 specific esters present in controls-2-ethylhexyl acetic ester, decanoic acid ethyl ester, dodecanoic acid ethyl ester, and hexadecanoic acid ethyl ester-were consistently absent from all faecal samples in those infants who developed NEC in the 4 days before the onset of the disease. CONCLUSION: : This pilot study shows that VOC extraction from faeces may be used to identify infants that are at risk of developing NEC.


Assuntos
Enterocolite Necrosante/patologia , Fezes/química , Doenças do Prematuro/patologia , Compostos Orgânicos Voláteis/isolamento & purificação , Fatores Etários , Envelhecimento/fisiologia , Estudos de Casos e Controles , Ésteres/metabolismo , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Projetos Piloto
5.
FASEB J ; 21(8): 1675-88, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17314143

RESUMO

Little is known about the volatile organic compounds (VOCs) in feces and their potential health consequences. Patients and healthcare professionals have observed that feces often smell abnormal during gastrointestinal disease. The aim of this work was to define the volatiles emitted from the feces of healthy donors and patients with gastrointestinal disease. Our hypotheses were that i) VOCs would be shared in health; ii) VOCs would be constant in individuals; and iii) specific changes in VOCs would occur in disease. Volatile emissions in health were defined in a cohort and a longitudinal study. Subsequently, the pattern of volatiles found in the cohort study were compared to that found from patients with ulcerative colitis, Campylobacter jejuni, and Clostridium difficile. Volatiles from feces were collected by solid-phase microextraction and analyzed by gas chromatography/mass spectrometry. In the cohort study, 297 volatiles were identified. In all samples, ethanoic, butanoic, pentanoic acids, benzaldehyde, ethanal, carbon disulfide, dimethyldisulfide, acetone, 2-butanone, 2,3-butanedione, 6-methyl-5-hepten-2-one, indole, and 4-methylphenol were found. Forty-four compounds were shared by 80% of subjects. In the longitudinal study, 292 volatiles were identified, with some inter and intra subject variations in VOC concentrations with time. When compared to healthy donors, volatile patterns from feces of patients with ulcerative colitis, C. difficile, and C. jejuni were each significantly different. These findings could lead the way to the development of a rapid diagnostic device based on VOC detection.


Assuntos
Infecções Bacterianas/diagnóstico , Fezes/química , Gastroenteropatias/diagnóstico , Compostos Orgânicos/análise , Adulto , Idoso , Bactérias/isolamento & purificação , Bactérias/metabolismo , Campylobacter jejuni/isolamento & purificação , Campylobacter jejuni/metabolismo , Estudos de Casos e Controles , Clostridioides difficile/isolamento & purificação , Clostridioides difficile/metabolismo , Fezes/microbiologia , Feminino , Gastroenteropatias/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Manejo de Espécimes
6.
J Breath Res ; 10(1): 017106, 2016 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-26865331

RESUMO

Prostate cancer is one of the most common cancers. Serum prostate-specific antigen (PSA) is used to aid the selection of men undergoing biopsies. Its use remains controversial. We propose a GC-sensor algorithm system for classifying urine samples from patients with urological symptoms. This pilot study includes 155 men presenting to urology clinics, 58 were diagnosed with prostate cancer, 24 with bladder cancer and 73 with haematuria and or poor stream, without cancer. Principal component analysis (PCA) was applied to assess the discrimination achieved, while linear discriminant analysis (LDA) and support vector machine (SVM) were used as statistical models for sample classification. Leave-one-out cross-validation (LOOCV), repeated 10-fold cross-validation (10FoldCV), repeated double cross-validation (DoubleCV) and Monte Carlo permutations were applied to assess performance. Significant separation was found between prostate cancer and control samples, bladder cancer and controls and between bladder and prostate cancer samples. For prostate cancer diagnosis, the GC/SVM system classified samples with 95% sensitivity and 96% specificity after LOOCV. For bladder cancer diagnosis, the SVM reported 96% sensitivity and 100% specificity after LOOCV, while the DoubleCV reported 87% sensitivity and 99% specificity, with SVM showing 78% and 98% sensitivity between prostate and bladder cancer samples. Evaluation of the results of the Monte Carlo permutation of class labels obtained chance-like accuracy values around 50% suggesting the observed results for bladder cancer and prostate cancer detection are not due to over fitting. The results of the pilot study presented here indicate that the GC system is able to successfully identify patterns that allow classification of urine samples from patients with urological cancers. An accurate diagnosis based on urine samples would reduce the number of negative prostate biopsies performed, and the frequency of surveillance cystoscopy for bladder cancer patients. Larger cohort studies are planned to investigate the potential of this system. Future work may lead to non-invasive breath analyses for diagnosing urological conditions.


Assuntos
Cromatografia Gasosa/métodos , Modelos Estatísticos , Neoplasias da Próstata/diagnóstico , Neoplasias da Bexiga Urinária/diagnóstico , Algoritmos , Testes Respiratórios , Humanos , Masculino , Projetos Piloto , Sensibilidade e Especificidade
7.
Chem Cent J ; 10: 9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26933445

RESUMO

BACKGROUND: Volatile organic compounds (VOCs) can be intermediates of metabolic pathways and their levels in biological samples may provide a better understanding about diseases in addition to potential methods for diagnosis. Headspace analysis of VOCs in urine samples using solid phase micro extraction (SPME) coupled to gas chromatography - mass spectrometry (GC-MS) is one of the most used techniques. However, it generally produces a limited profile of VOCs if applied to fresh urine. Sample preparation methods, such as addition of salt, base or acid, have been developed to improve the headspace-SPME-GC-MS analysis of VOCs in urine samples. These methods result in a richer profile of VOCs, however, they may also add potential contaminants to the urine samples, result in increased variability introduced by manually processing the samples and promote degradation of metabolites due to extreme pH levels. Here, we evaluated if freeze-drying can be considered an alternative sample preparation method for headspace-SPME-GC-MS analysis of urine samples. RESULTS: We collected urine from three volunteers and compared the performances of freeze-drying, addition of acid (HCl), addition of base (NaOH), addition of salt (NaCl), fresh urine and frozen urine when identifying and quantifying metabolites in 4 ml samples. Freeze-drying and addition of acid produced a significantly higher number of VOCs identified than any other method, with freeze-drying covering a slightly higher number of chemical classes, showing an improved repeatability and reducing siloxane impurities. CONCLUSION: In this work we compared the performance of sample preparation methods for the SPME-GC-MS analysis of urine samples. To the best of our knowledge, this is the first study evaluating the potential of freeze-dry as an alternative sample preparation method. Our results indicate that freeze-drying has potential to be used as an alternative method for the SPME-GC-MS analysis of urine samples. Additional studies using internal standard, synthetic urine and calibration curves will allow a more precise quantification of metabolites and additional comparisons between methods.Graphical abstractEnhancing VOC profiling from urine samples.

8.
PLoS One ; 8(3): e58204, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23516449

RESUMO

Diagnosing irritable bowel syndrome (IBS) can be a challenge; many clinicians resort to invasive investigations in order to rule out other diseases and reassure their patients. Volatile organic metabolites (VOMs) are emitted from feces; understanding changes in the patterns of these VOMs could aid our understanding of the etiology of the disease and the development of biomarkers, which can assist in the diagnosis of IBS. We report the first comprehensive study of the fecal VOMs patterns in patients with diarrhea-predominant IBS (IBS-D), active Crohn's disease (CD), ulcerative colitis (UC) and healthy controls. 30 patients with IBS-D, 62 with CD, 48 with UC and 109 healthy controls were studied. Diagnosis of IBS-D was made using the Manning criteria and all patients with CD and UC met endoscopic, histologic and/or radiologic criteria. Fecal VOMs were extracted by solid phase microextraction (SPME) and analyzed by gas chromatography-mass spectrometry (GC-MS). 240 VOMs were identified. Univariate analysis showed that esters of short chain fatty acids, cyclohexanecarboxylic acid and its ester derivatives were associated with IBS-D (p<0.05), while aldehydes were more abundant in IBD (p<0.05). A predictive model, developed by multivariate analysis, separated IBS-D from active CD, UC and healthy controls with a sensitivity of 94%, 96% and 90%; and a specificity of 82%, 80% and 80% respectively (p<0.05). The understanding of the derivation of these VOMs may cast light on the etiology of IBS-D and IBD. These data show that fecal VOMs analyses could contribute to the diagnosis of IBS-D, for which there is no laboratory test, as well as IBD.


Assuntos
Fezes/química , Síndrome do Intestino Irritável/diagnóstico , Metabolômica , Compostos Orgânicos Voláteis/química , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Doenças Inflamatórias Intestinais/diagnóstico , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Adulto Jovem
9.
Chem Commun (Camb) ; 46(25): 4583-5, 2010 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-20502784

RESUMO

An approach to the design, development and implementation of a new separation technology for use in the decontamination of radioactive waste streams is reported here. Calixarene-crown-6 derivatives with terminal carboxyl groups were synthesised and attached to nano-sized magnetoferritin molecules and their ability to sequester radioactive caesium(i) ions from aqueous solution was demonstrated.


Assuntos
Calixarenos/química , Magnetismo , Nanopartículas/química , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água , Estrutura Molecular , Estereoisomerismo
10.
Biomarkers ; 13(4): 413-21, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18484355

RESUMO

Volatile organic compounds from chicken faeces were investigated as biomarkers for Campylobacter infection. Campylobacter are major poultry-borne zoonotic pathogens, colonizing the avian intestinal tract. Chicken faeces are the principal source of contamination of carcasses. Fresh faeces were collected on farm sites, and Campylobacter status established microbiologically. Volatile organic compounds were pre-concentrated from the headspace above 71 separate faecal samples using solid-phase microextraction and separated and identified by gas chromatography/mass spectrometry. A Campylobacter-specific profile was identified using six of the extracted volatile organic compounds. The model developed reliably identified the presence or absence of Campylobacter in >95% of chickens. The volatile biomarker identification approach for assessing avian infection is a novel approach to enhancing biosecurity in the poultry industry and should reduce the risk of disease transmission to humans.


Assuntos
Infecções por Campylobacter/diagnóstico , Fezes/química , Compostos Orgânicos/análise , Animais , Biomarcadores/análise , Infecções por Campylobacter/metabolismo , Galinhas , Fezes/microbiologia , Cromatografia Gasosa-Espectrometria de Massas , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Microextração em Fase Sólida
11.
J Chem Phys ; 120(5): 2413-6, 2004 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-15268381

RESUMO

Reaction-diffusion systems where one of the reagents (outer electrolyte) penetrates into a gel by diffusion and forms a precipitate with the other reagent (inner electrolyte) homogenized in the gel, are able to produce various complex precipitation patterns. The previously studied NaOH + AgNO3 and recently discovered CuCl2 + K3[Fe(CN)6] processes, (where the first reagent is the outer electrolyte and the other is the inner electrolyte homogenized in the gel), when reacted using the above mentioned method, are able to generate tessellations of a plane by a mechanism dependant on the dynamics of so-called regressing edges of the reaction fronts. The spontaneous partitioning of the reacted phases results in the construction of a pattern analogous to a Voronoi diagram or one of their generalizations.

12.
Mycol Res ; 108(Pt 7): 806-14, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15446714

RESUMO

Volatile organic compounds (VOCs) emitted by two wood-rotting basidiomycete fungi, Serpula lacrymans (dry rot fungus) and Coniophora puteana (cellar fungus), and the timber of Pinus sylvestris (Scots pine), were identified. Several volatile collection techniques were employed including dichloromethane solvent extraction, solid-phase microextraction (SPME) and thermal desorption of VOCs entrained on Tenax GR. In addition, a new method of solid sample injection (SSI) is described which utilises a low injector temperature and an all-glass deactivated injector liner designed to minimise both the formation of pyrolysis products and analyte degradation. All the volatile compounds collected were analysed using electron impact capillary gas chromatography-mass spectrometry (GC-MS) on HP-5, HP-Innowax and beta-cyclodextrin columns. SSI and Tenax thermal desorption were found to be the most effective extraction methods. A total of 19 VOCs were observed from S. lacrymans grown on glass slides and pine, 15 from C. puteana grown on glass slides and 12 from P. sylvestris timber. S. lacrymans was found to emit, in low abundance, six unique VOCs, of which 2-methylbutanal was the greatest. The major volatile compound emitted by S. lacrymans was 1-octen-3-ol, which was also found in lower abundance from C. puteana. Six VOCs, including diethylene glycol and 4-methyl methylbenzoate, were found to be unique to C. puteana, all in medium abundance: From P. sylvestris, the major volatiles identified were S-alpha-pinene and 3-carene.


Assuntos
Basidiomycota/química , Pinus sylvestris/microbiologia , Cromatografia Gasosa-Espectrometria de Massas , Compostos Orgânicos/isolamento & purificação , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA