Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Imaging ; 24(7): 917-29, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16916709

RESUMO

OBJECTIVES: The aim of this study was to assess the consistency and performance of radiologists interpreting breast magnetic resonance imaging (MRI) examinations. MATERIALS AND METHODS: Two test sets of eight cases comprising cancers, benign disease, technical problems and parenchymal enhancement were prepared from two manufacturers' equipment (X and Y) and reported by 15 radiologists using the recording form and scoring system of the UK MRI breast screening study [(MAgnetic Resonance Imaging in Breast Screening (MARIBS)]. Variations in assessments of morphology, kinetic scores and diagnosis were measured by assessing intraobserver and interobserver variability and agreement. The sensitivity and specificity of reporting performances was determined using receiver operating characteristic (ROC) curve analysis. RESULTS: Intraobserver variation was seen in 13 (27.7%) of 47 of the radiologists' conclusions (four technical and seven pathological differences). Substantial interobserver variation was observed in the scores recorded for morphology, pattern of enhancement, quantification of enhancement and washout pattern. The overall sensitivity of breast MRI was high [88.6%, 95% confidence interval (CI) 77.4-94.7%], combined with a specificity of 69.2% (95% CI 60.5-76.7%). The sensitivities were similar for the two test sets (P=.3), but the specificity was significantly higher for the Manufacturer X dataset (P<.001). ROC curve analysis gave an area under the curve of 0.85 (95% CI 0.79-0.92) CONCLUSIONS: Substantial variation in all elements of the scoring system and in the overall diagnostic conclusions was observed between radiologists participating in MARIBS. High overall sensitivity was achieved with moderate specificity. Manufacturer-related differences in specificities possibly occurred because the numerical thresholds set for the scoring system were not optimised for both equipment manufacturers. Scoring systems developed on one equipment software may not be transferable to other manufacturers.


Assuntos
Neoplasias da Mama/diagnóstico , Competência Clínica , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Feminino , Humanos , Programas de Rastreamento , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA