The Covid-19 outbreak challenged health systems around the world to design and implement cost-effective devices produced locally to meet the increased demand of mechanical ventilators worldwide. This study evaluates the physiological responses of healthy swine maintained under volume- or pressure-controlled mechanical ventilation by a mechanical ventilator implemented to bring life-support by automating a resuscitation bag and closely controlling ventilatory parameters. Physiological parameters were monitored in eight sedated animals (t0) prior to inducing deep anaesthesia, and during the next six hours of mechanical ventilation (t1-7). Hemodynamic conditions were monitored periodically using a portable gas analyser machine (i.e. BEecf, carbonate, SaO2, lactate, pH, PaO2, PaCO2) and a capnometer (i.e. ETCO2). Electrocardiogram, echocardiography and lung ultrasonography were performed to detect in vivo alterations in these vital organs and pathological findings from necropsy were reported. The mechanical ventilator properly controlled physiological levels of blood biochemistry such as oxygenation parameters (PaO2, PaCO2, SaO2, ETCO2), acid-base equilibrium (pH, carbonate, BEecf), and perfusion of tissues (lactate levels). In addition, histopathological analysis showed no evidence of acute tissue damage in lung, heart, liver, kidney, or brain. All animals were able to breathe spontaneously after undergoing mechanical ventilation. These preclinical data, supports the biological safety of the medical device to move forward to further evaluation in clinical studies.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Respiração Artificial/instrumentação , Ventiladores Mecânicos , Animais , Automação , Gasometria , COVID-19/complicações , COVID-19/patologia , COVID-19/fisiopatologia , Feminino , Hemodinâmica , Masculino , Respiração , SARS-CoV-2/fisiologia , Suínos
2.
HardwareX ; 9: e00187, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33681539

RESUMO

In this article, we introduce a portable and low-cost ventilator that could be rapidly manufactured, to meet the increasing demand of ventilators worldwide produced by COVID-19 pandemic. These ventilators should be rapidly deployable and with functional capabilities to manage COVID-19 patients with severe acute respiratory distress syndrome (ARDS). Our implementation offers robustness, safety and functionality absent in existing solutions to the ventilator shortage (i.e., telemonitoring, easy-to-disinfect, modularity) by maintaining simplicity. The design makes use of a manual resuscitator as the core respiration component activated by a compression mechanism which consist of two electronically controlled paddles. The quality measurements obtained after testing on a calibrated artificial lung demonstrate repeatability and accuracy exceeding human capabilities of manual ventilation. The complete design files are provided in the supplementary materials to facilitate ventilator production even in resource-limited settings. The implementation of this mechanical ventilator could eliminate device rationing or splitting to serve multiple patients on ICUs.