Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 27(12): 5316-5324, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28656461

RESUMO

OBJECTIVES: Objectives of this study were to compare radial time-resolved phase contrast magnetic resonance imaging (4D Flow-MRI) with perivascular ultrasound (pvUS) and to explore a porcine model of acute pre-hepatic portal hypertension (PHTN). METHODS: Abdominal 4D Flow-MRI and pvUS in portal and splenic vein, hepatic and both renal arteries were performed in 13 pigs of approximately 60 kg. In six pigs, measurements were repeated after partial portal vein (PV) ligature. Inter- and intra-reader comparisons and statistical analysis including Bland-Altman (BA) comparison, paired Student's t tests and linear regression were performed. RESULTS: PvUS and 4D Flow-MRI measurements agreed well; flow before partial PV ligature was 322 ± 30 ml/min in pvUS and 297 ± 27 ml/min in MRI (p = 0.294), and average BA difference was 25 ml/min [-322; 372]. Inter- and intra-reader results differed very little, revealed excellent correlation (R 2 = 0.98 and 0.99, respectively) and resulted in BA differences of -5 ml/min [-161; 150] and -2 ml/min [-28; 25], respectively. After PV ligature, PV flow decreased from 356 ± 50 to 298 ± 61 ml/min (p = 0.02), and hepatic arterial flow increased from 277 ± 36 to 331 ± 65 ml/min (p = n.s.). CONCLUSION: The successful in vivo comparison of radial 4D Flow-MRI to perivascular ultrasound revealed good agreement of abdominal blood flow although with considerable spread of results. A model of pre-hepatic PHTN was successfully introduced and acute responses monitored. KEY POINTS: • Radial 4D Flow-MRI in the abdomen was successfully compared to perivascular ultrasound. • Inter- and intra-reader testing demonstrated excellent reproducibility of upper abdominal 4D Flow-MRI. • A porcine model of acute pre-hepatic portal hypertension was successfully introduced. • 4D Flow-MRI successfully monitored acute changes in a model of portal hypertension.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Hipertensão Portal/diagnóstico , Circulação Hepática/fisiologia , Angiografia por Ressonância Magnética/métodos , Veia Porta/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Modelos Animais de Doenças , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/fisiopatologia , Hipertensão Portal/fisiopatologia , Masculino , Veia Porta/fisiopatologia , Reprodutibilidade dos Testes , Suínos
2.
Eur Radiol ; 26(2): 547-55, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26017736

RESUMO

OBJECTIVES: To compare 3D-inversion-recovery balanced steady-state free precession (IR-bSSFP) non-contrast-enhanced magnetic resonance angiography (MRA) with 3D-contrast-enhanced MRA (CE-MRA) for assessment of renal artery stenosis (RAS) using digital subtraction angiography (DSA) as the reference standard. METHODS: Bilateral RAS were surgically created in 12 swine. IR-bSSFP and CE-MRA were acquired at 1.5 T and compared to rotational DSA. Three experienced cardiovascular radiologists evaluated the IR-bSSFP and CE-MRA studies independently. Linear regression models were used to calibrate and assess the accuracy of IR-bSSFP and CE-MRA, separately, against DSA. The coefficient of determination and Cohen's kappa coefficient were also generated. RESULTS: Calibration of the three readers' RAS grading revealed R(2) values of 0.52, 0.37 and 0.59 for NCE-MRA and 0.48, 0.53 and 0.71 for CE-MRA. Inter-rater agreement demonstrated Cohen's kappa values ranging from 0.25 to 0.65. Distal renal artery branch vessels were visible to a significantly higher degree with NCE-MRA compared to CE-MRA (p < 0.001). Image quality was rated excellent for both sequences, although image noise was higher with CE-MRA (p < 0.05). In no cases did noise interfere with image interpretation. CONCLUSIONS: In a well-controlled animal model of surgically induced RAS, IR-bSSFP based NCE-MRA and CE-MRA accurately graded RAS with a tendency for stenosis overestimation, compared to DSA. KEY POINTS: • IR-bSSFP and CE-MRA are accurate methods for diagnosis of renal artery stenosis • IR-bSSFP and CE-MRA demonstrate excellent agreement with DSA • Both IR-bSSFP and CE-MRA have a tendency to overestimate renal artery stenosis.


Assuntos
Angiografia Digital/métodos , Angiografia por Ressonância Magnética/métodos , Obstrução da Artéria Renal/patologia , Animais , Meios de Contraste , Modelos Animais de Doenças , Imageamento Tridimensional/métodos , Artéria Renal/patologia , Obstrução da Artéria Renal/diagnóstico , Reprodutibilidade dos Testes , Suínos
3.
Magn Reson Med ; 67(3): 638-44, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21713978

RESUMO

Accurate, noninvasive measurements of liver fat content are needed for the early diagnosis and quantitative staging of nonalcoholic fatty liver disease. Chemical shift-based fat quantification methods acquire images at multiple echo times using a multiecho spoiled gradient echo sequence, and provide fat fraction measurements through postprocessing. However, phase errors, such as those caused by eddy currents, can adversely affect fat quantification. These phase errors are typically most significant at the first echo of the echo train, and introduce bias in complex-based fat quantification techniques. These errors can be overcome using a magnitude-based technique (where the phase of all echoes is discarded), but at the cost of significantly degraded signal-to-noise ratio, particularly for certain choices of echo time combinations. In this work, we develop a reconstruction method that overcomes these phase errors without the signal-to-noise ratio penalty incurred by magnitude fitting. This method discards the phase of the first echo (which is often corrupted) while maintaining the phase of the remaining echoes (where phase is unaltered). We test the proposed method on 104 patient liver datasets (from 52 patients, each scanned twice), where the fat fraction measurements are compared to coregistered spectroscopy measurements. We demonstrate that mixed fitting is able to provide accurate fat fraction measurements with high signal-to-noise ratio and low bias over a wide choice of echo combinations.


Assuntos
Fígado Gorduroso/diagnóstico , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Água Corporal , Humanos , Interpretação de Imagem Assistida por Computador , Método de Monte Carlo , Imagens de Fantasmas
4.
J Magn Reson Imaging ; 34(3): 577-84, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21751287

RESUMO

PURPOSE: To demonstrate the feasibility of PC-VIPR (Phase Contrast Vastly undersampled Imaging with Projection Reconstruction) for the depiction and hemodynamic analysis of hepatic and splanchnic vessels in patients with portal hypertension. MATERIALS AND METHODS: Twenty-four cirrhotic patients (55.9 ± 10.4 years) were scanned using 5-point PC-VIPR for high spatial resolution imaging with large volume coverage at 3 Tesla (T) using a 32-channel body coil. Vessel segmentation and hemodynamic visualization included color-coded three-dimensional (3D) streamlines and particle traces. Segmentation quality was compared with contrast-enhanced multi-phase liver imaging. Flow pattern analysis was performed in consensus of three readers. The MELD score was calculated to estimate disease severity and was correlated to image quality. RESULTS: Good to excellent visualization quality was achieved in 23/24 cases. All arterial vessels and 144/168 vessels of the portal venous (PV) circulation were unambiguously identified. No correlation with the MELD score was found. Eight of 148 vessels of the PV circulation demonstrated reverse (hepatofugal) flow. Hepatofugal flow in small tributaries to PV flow were present in three cases despite hepatopetal flow in the PV. CONCLUSION: This feasibility study demonstrates the feasibility of PC-VIPR for simultaneous morphological and hemodynamic assessment of the hepatic and splanchnic vasculature in cirrhosis and portal hypertension. Future studies with quantitative analyses are warranted.


Assuntos
Artéria Hepática/patologia , Artéria Hepática/fisiopatologia , Hipertensão Portal/patologia , Hipertensão Portal/fisiopatologia , Imageamento Tridimensional/métodos , Circulação Esplâncnica , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Abdom Radiol (NY) ; 46(5): 2003-2013, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33377995

RESUMO

OBJECTIVES: Ferumoxytol is an ultra-small superparamagnetic iron oxide (USPIO) agent that is taken up by splenic tissue. This study describes our initial institutional experience of ferumoxytol-enhanced MRI (feMRI) for differentiating intrapancreatic splenules (IPS) from other pancreatic lesions. METHODS: In this retrospective study, patients with computed tomographic imaging that identified small enhancing lesions in the tail of the pancreas subsequently underwent feMRI for further characterization. The feMRI protocol included T2-weighted (T2w) imaging with and without fat suppression (FS), R2* mapping, diffusion-weighted imaging (DWI), and T1-weighted (T1w) imaging with FS, prior to contrast injection. Immediately after slow intravenous infusion with 3 mg/kg body weight ferumoxytol, T1w was repeated. Delayed imaging with all sequences were obtained 24-72 h after ferumoxytol administration. RESULTS: Seven patients underwent feMRI. In two patients, the pancreatic lesions were presumed as pancreatic neuroendocrine tumor (PNET) from feMRI and in the remaining 5 IPS. One of the two patients with PNET was symptomatic for NET. In another symptomatic patient with pathologically proven duodenal NET and suspected PNET, the pancreatic lesion was proven to be an IPS on feMRI. IPS demonstrated strong negative enhancement in feMRI on T2w and increased R2* values consistent with splenic tissue, while the presumed PNETs did not enhance. T2w FS was helpful on the pre-contrast images to identify IPS, while R2* did on post-contrast images. Neither DWI nor T1w contributed to differentiating PNETs from IPS. CONCLUSIONS: This study demonstrates the potential utility of feMRI as a helpful adjunct diagnostic tool for differentiating IPS from other pancreatic lesions. Further studies in larger patient cohorts are needed.


Assuntos
Óxido Ferroso-Férrico , Neoplasias , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos
6.
Abdom Radiol (NY) ; 46(9): 4200-4209, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33982186

RESUMO

OBJECTIVES: To evaluate the reproducibility of liver R2* measurements between a 2D cardiac ECG-gated and a 3D breath-hold liver CSE-MRI acquisition for liver iron quantification. METHODS: A total of 54 1.5 T MRI exams from 51 subjects (18 women, 36 men, age 35.2 ± 21.8) were included. These included two sub-studies with 23 clinical MRI exams from 19 patients identified retrospectively, 24 participants with known or suspected iron overload, and 7 healthy volunteers acquired prospectively. The 2D cardiac and the 3D liver R2* maps were acquired in the same exam. Either acquisitions were reconstructed using a complex R2* algorithm that accounts for the presence of fat and residual phase errors due to eddy currents. Data were analyzed using colocalized ROIs in the liver. RESULTS: Linear regression analysis demonstrated high Pearson's correlation and Lin's concordance coefficient for the overall study and both sub-studies. Bland-Altman analysis also showed good agreement, except for a slight increase of the mean R2* value above ~ 400 s-1. The Kolmogorow-Smirnow test revealed a non-normal distribution for (R2* 3D-R2* 2D) values from 0 to 600 s-1 in contrast to the 0-200 s-1 and 0-400 s-1 subpopulations. Linear regression analysis showed no relevant differences other than the intercept, likely due to only 7 measurements above 400 s-1. CONCLUSIONS: The results demonstrate that R2*-measurements in the liver are feasible using 2D cardiac R2* maps compared to 3D liver R2* maps as the reference. Liver R2* may be underestimated for R2* > 400 s-1 using the 2D cardiac R2* mapping method.


Assuntos
Sobrecarga de Ferro , Ferro , Adolescente , Adulto , Feminino , Humanos , Sobrecarga de Ferro/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
7.
AJNR Am J Neuroradiol ; 39(1): 24-30, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29146718

RESUMO

BACKGROUND AND PURPOSE: Intrinsic T1-hyperintense signal has recently been reported in the deep gray nuclei on brain MR imaging after multiple doses of gadolinium-based contrast agents. Most reports have included adult patients and excluded those undergoing radiation or chemotherapy. We investigated whether T1 shortening is also observed in children and tried to determine whether radiochemotherapy is a risk factor for this phenomenon. MATERIALS AND METHODS: In this single-center retrospective study, we reviewed clinical charts and images of all patients 18 years of age or younger with ≥4 gadobenate dimeglumine-enhanced MRIs for 6 years. Seventy-six children (mean age, 9.3 years; 60 unconfounded by treatment, 16 with radiochemotherapy) met the selection criteria (>4 MR imaging examinations; mean, 8). T1 signal intensity ratios for the dentate to pons and globus pallidus to thalamus were calculated and correlated with number of injections, time interval, and therapy. RESULTS: Among the 60 children without radiochemotherapy, only 2 had elevated T1 signal intensity ratios (n = 20 and 16 injections). Twelve of the 16 children with radiochemotherapy showed elevated signal intensity ratios. Statistical analysis demonstrated a significant signal intensity ratio change for the number of injections (P < .001) and amount of gadolinium (P = .008), but not for the interscan time interval (P = .35). There was a significant difference in the average signal intensity ratio change between those with and without radiochemotherapy (P < .001). Chart review revealed no new neurologic deficits in any patients, related to their underlying conditions and prior surgeries. CONCLUSIONS: Compared with published adult series, children show a similar pattern of T1 hyperintense signal changes of the dentate and globus pallidus after multiple gadobenate dimeglumine injections. The T1 signal changes in children may have a later onset but are accelerated by radiochemotherapy.


Assuntos
Encéfalo/efeitos dos fármacos , Meios de Contraste/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/efeitos adversos , Adolescente , Encéfalo/diagnóstico por imagem , Encéfalo/efeitos da radiação , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/radioterapia , Quimiorradioterapia , Criança , Feminino , Humanos , Masculino , Meglumina/efeitos adversos , Estudos Retrospectivos
8.
Top Magn Reson Imaging ; 11(6): 312-30, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11153700

RESUMO

Cardiac magnetic resonance imaging is a rapidly emerging field that has seen tremendous advances in the past decade. Central to the development of effective imaging strategies has been the advent of high-performance gradient hardware and the exploitation of their speed characteristics through specialized pulse sequences well suited for cardiac imaging. These advances have facilitated unprecedented acquisition times that now approach echocardiographic frame rates, while maintaining excellent image quality. This article provides a detailed overview of advanced pulse sequence technology and approaches currently taken to maximize speed performance and image quality. In particular, segmented K-space techniques that include single-echo and multiecho spoiled gradient-echo imaging as well as steady-state free precession imaging are discussed. Finally, spiral and fast spin-echo techniques are explored. Examples of common applications of these pulse sequences are presented.


Assuntos
Imagem Ecoplanar/métodos , Cardiopatias/diagnóstico , Intensificação de Imagem Radiográfica/métodos , Feminino , Análise de Fourier , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Sensibilidade e Especificidade
9.
AJNR Am J Neuroradiol ; 35(5): 999-1006, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24287088

RESUMO

BACKGROUND AND PURPOSE: The chronic cerebrospinal venous insufficiency hypothesis raises interest in cerebrospinal venous blood flow imaging, which is more complex and less established than in arteries. For accurate assessment of venous flow in chronic cerebrospinal venous insufficiency diagnosis and research, we must account for physiologic changes in flow patterns. This study examines day-to-day flow variability in cerebrospinal veins by use of 4D MR flow and contrast-enhanced MRA under typical, uncontrolled conditions in healthy individuals. MATERIALS AND METHODS: Ten healthy volunteers were scanned in a test-retest fashion by use of a 4D flow MR imaging technique and contrast-enhanced MRA. Flow parameters obtained from phase contrast-vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA scoring measurements in the head, neck, and chest veins were analyzed for internal consistency and interscan reproducibility. RESULTS: Internal consistency was satisfied at the torcular herophili, with an input-output difference of 2.2%. Percentages of variations in flow were 20.3%, internal jugular vein; 20.4%, azygos vein; 6.8%, transverse sinus; and 5.1%, common carotid artery. Retrograde flow was found in the lower internal jugular vein (4.8%) and azygos vein (7.2%). Contrast-enhanced MRA interscan κ values for the internal jugular vein (left: 0.474, right: 0.366) and azygos vein (-0.053) showed poor interscan agreement. CONCLUSIONS: Phase contrast-vastly undersampled isotropic projection reconstruction blood flow measurements are reliable and highly reproducible in intracranial veins and in the common carotid artery but not in veins of the neck (internal jugular vein) and chest (azygos vein) because of normal physiologic variation. Retrograde flow normally may be observed in the lower internal jugular vein and azygos vein. Low interrater agreement in contrast-enhanced MRA scans was observed. These findings have important implications for imaging diagnosis and experimental research of chronic cerebrospinal venous insufficiency.


Assuntos
Veias Cerebrais/anatomia & histologia , Veias Cerebrais/fisiologia , Gadolínio , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos , Medula Espinal/irrigação sanguínea , Adulto , Algoritmos , Anisotropia , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade
10.
Osteoarthritis Cartilage ; 13(4): 338-44, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15780647

RESUMO

OBJECTIVE: To compare articular cartilage signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and thickness measurements on a 1.5 T and a 3.0 T magnetic resonance (MR) scanner using three-dimensional spoiled gradient recalled echo (3D-SPGR) and two 3D steady-state free precession (SSFP) sequences. METHODS: Both knees of five volunteers were scanned at 1.5 T and at 3.0 T using a transmit-receive quadrature extremity coil. Each examination consisted of a sagittal 3D-SPGR sequence, a sagittal fat suppressed 3D-SSFP (FS-SSFP) sequence, and a sagittal Dixon 3D-SSFP sequence. For quantitative analysis, we compared cartilage SNR and CNR efficiencies, as well as average cartilage thickness measurements. RESULTS: For 3D-SPGR, cartilage SNR efficiencies at 3.0 T increased compared to those at 1.5 T by a factor of 1.83 (range: 1.40-2.09). In comparison to 3D-SPGR, the SNR efficiency of FS-SSFP increased by a factor of 2.13 (range: 1.81-2.39) and for Dixon SSFP by a factor of 2.39 (range: 1.95-2.99). For 3D-SPGR, CNR efficiencies between cartilage and its surrounding tissue increased compared to those at 1.5 T by a factor of 2.12 (range: 1.75-2.47), for FS-SSFP by a factor 2.11 (range: 1.58-2.80) and for Dixon SSFP by a factor 2.39 (range 2.09-2.83). Average cartilage thicknesses of load bearing regions were not different at both field strengths or between sequences (P>0.05). Mean average cartilage thickness measured in all knees was 2.28 mm. CONCLUSION: Articular cartilage imaging of the knee on a 3.0 T MR scanner shows increased SNR and CNR efficiencies compared to a 1.5 T scanner, where SSFP-based techniques show the highest increase in SNR and CNR efficiency. There was no difference between average cartilage thickness measurements performed at the 1.5 T and 3.0 T scanners or between the three different sequences.


Assuntos
Cartilagem Articular/anatomia & histologia , Articulação do Joelho/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Cartilagem Articular/fisiologia , Feminino , Fêmur/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Articulação do Joelho/fisiologia , Masculino , Suporte de Carga
11.
Magn Reson Med ; 31(5): 521-5, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-8015405

RESUMO

Contrast between tagged and nontagged myocardium was investigated using rapid gradient echo segmented k-space CINE MRI. The transient behavior of magnetization was measured in stationary and moving phantoms using gradient recalled acquisition in steady-state GRASS and spoiled GRASS (SPGR) sequences with TR approximately 7 ms and TE approximately 2.5 ms. Bloch equation simulations were used to compute theoretical results. Understanding the transient behavior of magnetization is important because tags only persist in the myocardium during the nonequilibrium transition to steady state. The transition to steady state for both SPGR and GRASS is reproducible after one heartbeat, and including unprocessed data from the first heartbeat leads to image artifacts. In a moving phantom, simulations and experimental results showed that GRASS and SPGR are essentially equivalent. Tag-tissue contrast in SPGR was very sensitive to imaging tip angle. The optimum tip angle for the scanning parameters used in this study was 11 degrees.


Assuntos
Coração/fisiologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Contração Miocárdica/fisiologia , Algoritmos , Artefatos , Simulação por Computador , Cobre , Sulfato de Cobre , Eletrocardiografia , Frequência Cardíaca/fisiologia , Humanos , Modelos Cardiovasculares , Modelos Estruturais , Filmes Cinematográficos , Movimento , Sefarose
12.
Magn Reson Med ; 32(5): 612-21, 1994 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7808262

RESUMO

The effect of gradient system performance on segmented k-space gradient echo imaging is presented. Three cases were investigated. First, an ideal system that has infinite slew rates and unlimited maximum gradient strengths was considered. Second, a "high speed" imaging system (2.3 (G/cm), 23 (G/cm)/ms) was considered. These two cases were compared with a "conventional" imaging system (1(G/cm), 1.67 (G/cm)/ms). It was found that substantial increases in SNR can be achieved (approximately 45%) by using high speed versus a conventional gradient system, for a TR of 6 ms. For trapezoidal gradient waveforms, there exists an optimum maximum gradient strength for a given slew rate, and any increase in gradient strength above this optimum will not be utilized by an optimized sequence. These studies have shown that increasing TR without decreasing the bandwidth is not a good way to increase SNR for constant scan time.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Teóricos , Processamento de Sinais Assistido por Computador , Algoritmos , Simulação por Computador , Coração/anatomia & histologia , Coração/fisiologia , Humanos , Modelos Estruturais , Contração Miocárdica/fisiologia
13.
Magn Reson Med ; 41(2): 334-42, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10080282

RESUMO

To investigate the effects of water exchange on quantification of perfusion, data were acquired in isolated hearts (n = 11) and used to develop a model of exchange. Myocardial T1 was measured 3 times/sec during step changes in concentration of intravascular (polylysine-gadolinium-diethylene-triamine-pentaacetic acid) and extracellular (gadoteridol) agents. For the intravascular agent, the change in 1/T1 (deltaR1) was lower than predicted by fast exchange (2.7+/-0.5 vs. 7.8 sec(-1), respectively), and suggested an intra-extravascular exchange rate of 3 Hz. For the extracellular agent, contrast kinetics were similar to those of similarly sized molecules (wash-in time constant 38+/-5 sec), and the data suggested fast interstitial-cellular exchange. Modeling showed that perfusion is underestimated for both agents if exchange is ignored, although the relationships of measured to actual perfusion were monotonic. We conclude that myocardial water exchange strongly affects first-pass enhancement but that ignoring the effects of exchange may still provide reasonable estimates of regional perfusion differences.


Assuntos
Água Corporal/metabolismo , Meios de Contraste , Circulação Coronária , Imageamento por Ressonância Magnética , Miocárdio/metabolismo , Animais , Gadolínio , Gadolínio DTPA , Compostos Heterocíclicos , Técnicas In Vitro , Compostos Organometálicos , Polilisina/análogos & derivados , Coelhos
14.
Radiology ; 190(3): 765-9, 1994 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8115625

RESUMO

PURPOSE: To validate cine magnetic resonance (MR) image tagging measurements of a deforming object by means of a precise photographic method. MATERIALS AND METHODS: A piece of silicone rubber that acted as a phantom was stretched in a cyclical fashion inside a plastic clamp driven by a respirator pump. Deformation as a function of time was measured with a rapid gradient-echo cine tagging sequence and with sequential stroboscopic photographs. Deformations from 1.0 to 1.2 (0% to 20% stretch) in the readout direction were measured over a 7-cm region of the phantom, which had a maximum standard error of +/- 0.001 with photography and a maximum standard error of +/- 0.003 with MR imaging. RESULTS: The deformation versus time values measured with MR imaging had a standard error of 0.002 about a straight line fit to the photographic deformation versus time data. These results demonstrate that the MR imaging deformation estimates were accurate and precise. CONCLUSION: The validated tagging method can now be used to evaluate MR imaging motion estimation techniques.


Assuntos
Artefatos , Imageamento por Ressonância Magnética/métodos , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/normas , Modelos Estruturais , Movimento (Física) , Fotografação , Elastômeros de Silicone
15.
Magn Reson Med ; 40(2): 334-40, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9702716

RESUMO

Adiabatic pulses, although useful in generating uniform spin nutation in the presence of inhomogeneous B1 fields, are limited for NMR imaging applications due to the lack of slice-selective excitation capability. Selective excitation techniques using gradient modulation have been introduced; however, present methods require either a minimum of two excitations or eight adiabatic segments. Here, a scheme is presented that allows single-shot, arbitrary flip-angle, and slice-selective excitation with only four adiabatic half-passage segments. The technique is demonstrated via computer simulation and experimental tests on a phantom. Furthermore, issues associated with the implementation of these gradient-modulated adiabatic pulses are discussed.


Assuntos
Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Simulação por Computador , Análise de Fourier , Humanos , Imagens de Fantasmas , Sensibilidade e Especificidade
16.
AJR Am J Roentgenol ; 177(3): 595-8, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11517052

RESUMO

OBJECTIVE: Treatment of iatrogenic femoral artery pseudoaneurysms with thrombin injection has been reported as an efficacious and safe procedure. The major risk of this procedure is distal limb ischemia from thrombosis, resulting from thrombin escape. The cumulative average dose of thrombin reported in the literature is approximately 1100 U per patient. Minimizing the thrombin dose may reduce the risks of the procedure. This study reports our experience with low-dose thrombin injection for the treatment of pseudoaneurysms. MATERIALS AND METHODS: Twenty-three patients with 26 postcatheterization femoral pseudoaneurysms were administered thrombin injection with color-flow Doppler sonographic guidance. Pseudoaneurysm volume ranged from 1 to 41 cm(3) with an average of 6.7 cm(3) and a median of 4 cm(3). Two patients received therapeutic doses of IV heparin for anticoagulation. When possible, the neck of the pseudoaneurysm was occluded during the injection to promote stagnation and prevent thrombin leakage. Sonographic follow-up was routinely performed after 24 hr. RESULTS: An average dose of 192 U of thrombin was used (range, 50-450 U), and time to coagulation ranged from 10 to 60 sec. All 26 pseudoaneurysms were successfully thrombosed, although one required repeated treatment because of recanalization noted at 1-day follow-up. There were no complications. CONCLUSION: Doses of thrombin at an average of fivefold lower than previously reported were effective in the treatment of 26 iatrogenic femoral pseudoaneurysms, even in the presence of anticoagulation. This experience shows that a much smaller dose of a potentially dangerous medication can achieve the same efficacy as previously used higher doses.


Assuntos
Falso Aneurisma/tratamento farmacológico , Cateterismo Cardíaco , Artéria Femoral , Trombina/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Falso Aneurisma/diagnóstico por imagem , Relação Dose-Resposta a Droga , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/efeitos dos fármacos , Humanos , Doença Iatrogênica , Injeções , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Ultrassonografia Doppler em Cores
17.
Magn Reson Med ; 37(1): 124-30, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8978641

RESUMO

Progress in research on hypertension, heart failure, aging, post-infarct remodeling, and the molecular basis of cardiovascular diseases in general has been greatly facilitated in recent years by the development of specialized small-mammal models by selective breeding and/or genetic alteration. Routine noninvasive evaluation of cardiac function and perfusion in these animals models, however, is difficult using existing methods. In principle, MRI can be used for this purpose, but in practice this is difficult because of problems related to RF coils, cardiac gating, and imaging pulse sequences. In this article, solutions to these problems are described that have allowed us to use MRI to routinely image the hearts of rats and rabbits. Specifically described are four RF coils, cardiac gating schemes, and an imaging pulse sequence specially designed for cardiac imaging in these animals on a 4.7 T Omega chemical-shift imaging (CSI) spectrometer. These techniques can be used to obtain, within 2 min, eight double-oblique short-axis images of the rat at different cardiac phases with 200 x 400 microm in-plane resolution and a slice thickness of 2 mm. Moreover, myocardial tissue tagging can be performed with tag thicknesses and separations comparable to those used routinely in humans. The technical information is presented in sufficient detail to allow researchers at other sites to reproduce the results. This information should facilitate the use of MRI for the noninvasive examination of cardiac function and perfusion, which can be combined with other established techniques for the study of cardiovascular disease in specialized animal models.


Assuntos
Coração/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Animais , Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/métodos , Coelhos , Ratos , Fatores de Tempo
18.
Magn Reson Med ; 39(6): 988-98, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9621923

RESUMO

Cardiac echo-planar imaging suffers invariably from regions of severe distortion and T*2 decay in the myocardium. The purpose of this work was to perform local measurements of T*2 and field inhomogeneities in the myocardium and to identify the sources of focal signal loss and distortion. Field inhomogeneity maps and T*2 were measured in five normal volunteers in short-axis slices spanning from base to apex. It was found that T*2 ranged from 26 ms (SD = 7 ms, n = 5) to 41 ms (SD = 11 ms, n = 5) over most of the heart, and peak-to-peak field inhomogeneity differences were 71 Hz (SD = 14 Hz, n = 5). In all hearts, regions of severe signal loss were consistently adjacent to the posterior vein of the left ventricle; T*2 in these regions was 12 ms (SD = 2 ms, n = 5), and the difference in resonance frequency with the surrounding myocardium was 70-100 Hz. These effects may be caused by increased magnetic susceptibility from deoxygenated blood in these veins.


Assuntos
Imagem Ecoplanar/instrumentação , Coração/anatomia & histologia , Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Artefatos , Vasos Coronários/anatomia & histologia , Septos Cardíacos/anatomia & histologia , Ventrículos do Coração/anatomia & histologia , Humanos , Sensibilidade e Especificidade
19.
Magn Reson Med ; 34(2): 276-82, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7476088

RESUMO

A T1-weighted imaging pulse sequence for contrast-based studies of myocardial perfusion is presented and evaluated in phantoms and in vivo. The sequence is similar to spoiled gradient-recalled echo sequences except that nonselective preparatory RF pulses drive magnetization to steady state prior to image acquisition. Steady state is thus obtained in both tissue and blood resulting in a stable, homogeneous, and dark pre-contrast baseline. Tip angles and timings are chosen so that pixel intensity approximates a linear relation to 1/T1. The dynamic range of signal response to contrast agent concentration is greater than that of an inversion-recovery fast low angle shot sequence. The sequence proposed should be useful for myocardial perfusion studies.


Assuntos
Circulação Coronária , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Sangue , Simulação por Computador , Meios de Contraste , Análise de Fourier , Gadolínio , Coração/anatomia & histologia , Frequência Cardíaca , Compostos Heterocíclicos , Humanos , Magnetismo , Modelos Estruturais , Modelos Teóricos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Compostos Organometálicos , Ondas de Rádio , Processamento de Sinais Assistido por Computador
20.
Magn Reson Med ; 38(3): 429-39, 1997 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9339445

RESUMO

A mathematical analysis of ghosting artifacts often seen in interleaved echo-planar images (EPI) is presented. These artifacts result from phase and amplitude discontinuities between lines of k-space in the phase-encoding direction, and timing misregistrations from system filter delays. Phase offsets and time delays are often measured using "reference" scans, to reduce ghosting through postprocessing. From the expressions describing ghosting artifacts, criteria were established for reducing ghosting to acceptable levels. Subsequently, the signal-to-noise ratio (SNR) requirements for estimation of time delays and phase offsets, determined from reference scans, was evaluated to establish the effect of estimation error on artifact reduction for interleaved EPI. Artifacts resulting from these effects can be reduced to very low levels when appropriate reference scan estimation is used. This has important implications for functional MRI (fMRI) and applications involving small changes in signal intensity.


Assuntos
Artefatos , Imagem Ecoplanar/normas , Aumento da Imagem/métodos , Modelos Teóricos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA