Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 207
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 79(1): 24-33, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37734570

RESUMO

OBJECTIVE: Type II endoleak is the most frequent complication after endovascular abdominal aneurysm repair. Polytetrafluoroethylene and polyester (PE) are the two most commonly used graft materials in endovascular aneurysm repair (EVAR) devices. Biological properties of the material might influence the appearance and persistence of type II endoleak (T2EL). Therefore, the aim of this study was to evaluate potential differences in the prevalence of T2EL after EVAR between polytetrafluoroethylene (PTFE) and PE endografts in patients electively treated for an infrarenal abdominal aortic aneurysm. METHODS: A single-center, retrospective, observational study was conducted between January 2011 and January 2022. Preoperative, procedural, and follow-up data were derived from electronic health records. Imaging included computed tomography scans, and/or duplex ultrasound examination. The primary end point was the prevalence of T2EL diagnosed within 1 year after EVAR. Secondary end points included the prevalence of T2EL throughout follow-up, early (≤30 days) and late (>30 days) T2EL, the rate of T2EL disappearance during the follow-up period, the prevalence of type I and III endoleak, and T2EL-related reinterventions. RESULTS: Follow-up was available for 394 patients, 245 in the PE and 149 in the PTFE group. The prevalence of T2EL diagnosed within 1 year after endovascular repair was 11.8% in the PE group and 21.5% in the PTFE group (P = .010). There was no significant difference in early (≤30 days) and late (>30 days) T2EL between groups (P = .270 and P = .311). There was no difference in the freedom from endoleak type II reinterventions between groups (P = .877). CONCLUSIONS: The prevalence of T2EL after elective EVAR is significantly higher with the use of PTFE-based endografts compared with PE-based endografts. This difference is mostly based on T2EL diagnosed after 30 days of follow-up.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/epidemiologia , Endoleak/etiologia , Estudos Retrospectivos , Prevalência , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Politetrafluoretileno
2.
J Vasc Surg ; 79(5): 1090-1100.e4, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38185214

RESUMO

OBJECTIVE: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure. METHODS: Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands. The study population was adult candidates for elective EVAR of an infrarenal AAA (diameter of ≥55 mm in men and ≥50 mm in women). Key exclusion criteria were an inability to adequately seal a common iliac artery aneurysm, patent sac feeding vessels of >4 mm, and a target lumen volume of <20 mL or >135 mL. Target lumen volumes were estimated by subtracting endograft volumes from preprocedural imaging-based flow lumen volumes. SMP devices were delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. The primary efficacy end point was technical success, defined as filling the actual target lumen volume with fully expanded SMP at the completion of the procedure. Secondary efficacy outcome measures during follow-up were the change in sac volume and diameter, rate of type II endoleak and type I or III endoleaks, and the rate of open repair and related reinterventions, with data collection at 30 days, 6 months, and 1 year (to date). Baseline sac volumes and diameters for change in sac size analyses were determined from 30-day imaging studies. Baseline and follow-up volumes were normalized by subtraction of the endograft volume. RESULTS: Of 34 patients treated with SMP devices and followed per protocol, 33 patients were evaluable at 1 year. Preprocedural aneurysm volume was 181.4 mL (95% confidence interval [CI], 150.7-212.1 mL) and preprocedural aneurysm diameter was 60.8 mm (95% CI, 57.8-63.9 mm). The target lumen volume was 56.3 mL (95% CI, 46.9-65.8 mL). Technical success was 100% and the ratio of SMP fully expanded volume to estimated target lumen volume was 1.4 ± 0.3. Baseline normalized sac volume and diameter were 140.7 mL (95% CI, 126.6-154.9 mL) and 61.0 mm (95% CI, 59.7-62.3 mm). The adjusted mean percentage change in normalized volume at 1 year was -28.8% (95% CI, -35.3 to -22.3%; P < .001). The adjusted mean change in sac diameter at 1 year was -5.9 mm (95% CI, -7.5 to -4.4 mm; P < .001). At 1 year, 81.8% of patients (95% CI, 64.5%-93.0%) achieved a ≥10% decrease in normalized volume and 57.6% of patients (95% CI, 39.2%-74.5%) achieved a ≥5 mm decrease in diameter. No device- or study procedure-related major adverse events occurred through 1 year after the procedure. CONCLUSIONS: Treatment of AAA sacs with SMP devices during EVAR resulted in significant sac volume and diameter regression at 1 year with an acceptable safety profile in this prospective study.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Feminino , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Estudos Prospectivos , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Seguimentos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Fatores de Risco
3.
J Vasc Surg ; 80(2): 505-514.e2, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38604319

RESUMO

OBJECTIVE: In two randomized controlled trials, the outcomes of endovascular treatment of complex femoropopliteal arterial lesions were compared with bypass surgery and considered a valid alternative treatment. The aim of this study was to compare both endovascular treatment options with the hypothesis that implantation of heparin-bonded self-expanding covered stents (Viabahn [SECS]) or drug-eluting stents (ZilverPTX [DES]) are related to similar clinical outcomes at 1-year follow-up. METHODS: In a post-hoc analysis, the SuperB trial and Zilverpass databases were merged. Patients in the endovascular treatment arms were included, and data was analyzed in an intention-to-treat (ITT) and a per-protocol (PP) fashion. Data included baseline and lesion characteristics, procedural details, and follow-up data. The primary endpoint of this study was primary patency at 1-year follow-up. The secondary endpoints were secondary patency, target lesion revascularization (TLR), limb loss, and all-cause mortality. RESULTS: A total of 176 patients were included; 63 in the SECS arm and 113 in the DES arm. Through 1-year follow-up, there were no significant differences in primary patency (ITT: 63.4% vs 71.1%: P = .183 and PP: 60.8% vs 71.1%; P = .100). Secondary patency rates were not significantly different in the ITT analysis (86.5% vs 95.1%; P = .054), but in the PP analysis, there was a significant difference in favor of the DES group (SECS, 85.6% vs DES, 95.1%; P = .038). There was no significant difference in freedom from TLR between groups (79.6% vs 77.0%; P = .481). No major amputations were performed in the SECS group, and two were performed in the DES group (1.8%). Survival rate was 98.2% in the SECS group, and 91.3% in the DES group after 1-year follow-up (P = .106). Based on diagnosis (intermittent claudication vs chronic limb-threatening ischemia) no differences between patients with intermittent claudication and chronic limb-threatening ischemia were observed in primary patency, secondary patency and freedom from TLR. CONCLUSIONS: Treatment of complex femoropopliteal arterial disease with the heparin-bonded Viabahn endoprosthesis and the Zilver PTX drug-eluting stent are related to similar primary and secondary patency, and TLR rates at 1 year, except for secondary patency in the PP analysis. This study further supports the endovascular treatment of long complex lesions in the femoropopliteal artery.


Assuntos
Stents Farmacológicos , Procedimentos Endovasculares , Artéria Femoral , Salvamento de Membro , Doença Arterial Periférica , Grau de Desobstrução Vascular , Humanos , Artéria Femoral/fisiopatologia , Artéria Femoral/diagnóstico por imagem , Masculino , Feminino , Doença Arterial Periférica/terapia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Idoso , Fatores de Tempo , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Resultado do Tratamento , Materiais Revestidos Biocompatíveis , Heparina/administração & dosagem , Pessoa de Meia-Idade , Fatores de Risco , Desenho de Prótese , Amputação Cirúrgica , Anticoagulantes/uso terapêutico , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Stents , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
J Endovasc Ther ; : 15266028231224257, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38193446

RESUMO

OBJECTIVE: The upside-down configuration of a Gore Excluder contralateral leg endoprosthesis has been used to overcome diameter differences in the endovascular treatment of aortoiliac aneurysms. Our goal was not to describe the technique but to study the applicability and safety. MATERIAL AND METHODS: Patients were retrospectively enrolled. The indication and details of the procedure were at the discretion of the treating physicians. A case report form was completed including baseline characteristics, indication for treatment, procedural data, and outcomes during follow-up. RESULTS: A total of 31 subjects were enrolled with a range of indications, including 3 patients treated in the emergency setting (9.7%). In 64.5% (n=20), it was a primary intervention for a common iliac aneurysm (n=10), internal iliac aneurysm (n=4), or abdominal aortic aneurysm (n=6). In 11 subjects (35.5%), treatment was performed after previous aortoiliac interventions, including anastomotic iliac artery aneurysm (n=5), type III endoleak (n=3), and endograft thrombus (n=3). Median follow-up was 13 months (range=1-142 months). During follow-up, 2 patients required an upside-down contralateral leg-related secondary intervention, one for an occlusion and another for a type Ia endoleak. There was no type Ib or III endoleak, and no migration, kinking/stenosis, or conversion to open repair was observed. The aneurysm-related mortality was 3.3% (n=1). CONCLUSION: An upside-down contralateral leg is a valuable technique that can be used to achieve adequate aneurysm exclusion or resolve complications. It is associated with a limited number of complications. CLINICAL IMPACT: This article studies the use of an upside-down iliac endograft. We describe a wide range of indications in which this previously published technique has been applied. In elective and acute settings and as primary and revision intervention an upside-down iliac endograft was performed successfully. Furthermore, follow-up data is presented showing the effectiveness of the technique. Knowledge of this procedure is a valuable addition to the skillset of every interventionalist.

5.
J Endovasc Ther ; : 15266028241245602, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38590283

RESUMO

OBJECTIVE: To assess the impact of heparin-bonded endoprosthesis compared with femoropopliteal bypass on key hospital resources and revenues up to 1-year follow-up. DESIGN: A 2-arm scenario resource consumption data analysis was modeled based on a multicentre prospective randomized controlled trial. SETTING: Six centers in the Netherlands. PARTICIPANTS: A total of 100 patients were assigned to 2 arms (50 each arm). The first arm evaluated endovascular treatment using the heparin-bonded Viabahn endoprosthesis and the second the femoropopliteal bypass. Resource consumption rates were compared between arms. PRIMARY AND SECONDARY OUTCOMES MEASURES: Resource consumption rates, including hospital stay for bypass procedure, operating room time, type of anesthesia, number of used (endo)grafts, use of different types of bed locations (vascular ward, medium or intensive care), readmission for wound infections, and reinterventions over a period of 12 months. RESULTS: Endovascular repair used fewer hospital resources, with an overall difference of €149.983. Hospital stay was 118 days less (261 vs 379), including 21 fewer days in medium/intensive care (5 vs 26) and 50 fewer operating room hours (100 vs 150). Fewer patients required general anesthesia (31 vs 39), and there were less surgical site infections (3 vs 12). In the surgical bypass group, there were 18 fewer days of hospital stay related to reinterventions (80 vs 62), and the cost of the devices was €309.996, cheaper. The total monetary difference was € 160.013, in favor of the femoropopliteal bypass (€3.200, per patient). CONCLUSIONS: Endovascular repair of the superficial femoral artery reduces the use of valuable hospital resources. Its major limitation is the cost of the devices, which should be balanced against the reduction in peri-procedural morbidity and faster recovery. In the context of shortage of hospital beds, it offers capacity benefits, allowing for the treatment of more patients overall. These benefits may outweigh the fewer reinterventions in the surgical bypass group. REGISTRATION: The SuperB Trial was registered in clinicaltrials.gov; NCT-ID: NCT01220245. CLINICAL IMPACT: Modeling is a useful technique to predict the impact of treatment modalities on hospital resources and revenue. This study uses real-world data from the SuperB Trial to compare two treatment strategies of superficial femoral artery disease, reflecting actual clinical practice and patient outcomes. The analysis focused on direct costs associated with hospital resources and device usage without considering indirect costs or long-term cost-effectiveness. The analysis showed that endovascular repair reduces the use of valuable hospital resources. Its major limitation is device costs, which should be balanced against the reduction in peri-procedural morbidity and faster recovery. In the context of shortage of hospital beds, it offers capacity benefits, allowing for the treatment of more patients overall.

6.
J Endovasc Ther ; : 15266028241231520, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38349021

RESUMO

OBJECTIVE: This study aims to compare the 5-year outcomes of endoluminal bypass (EB) using heparin-bonded self-expanding covered stents versus bypass surgery for extensive femoropopliteal disease, including technical and clinical outcomes and health status. BACKGROUND: The surgical femoropopliteal bypass was the gold standard to treat peripheral arterial disease (PAD) for decades; however, endovascular treatment modalities are now recommended for most femoropopliteal lesions. One-year data of a randomized controlled trial comparing EB with surgical bypass (SB) have shown a faster recovery, less morbidity, and comparable patency rates between the two techniques. To date, long-term randomized controlled data regarding both techniques are lacking. METHODS: Five-year results of a multicenter randomized controlled trial comparing EB with SB in patients with femoropopliteal artery disease were evaluated based on intention-to-treat and per-protocol analyses. RESULTS: At 5-year follow-up, primary, primary-assisted, and secondary patency rates were 36.2%, 52.4%, and 68.1% for EB and 49.4%, 72.2%, and 77.8% for SB, respectively (p=0.608). Freedom from target lesion revascularization (fTLR) was 34.1% for EB and 57.6% for SB (p=0.365). In both groups, the ankle-brachial index, Rutherford classification, and walking distance significantly improved compared with baseline without differences between groups at follow-up. Freedom from major amputation rate was 92.6% in the EB group and 96.2% in the SB group (p=0.361). The 36-Item Short-Form Health Survey showed no significant differences between groups. CONCLUSION: Treatment of extensive femoropopliteal disease with self-expanding covered stents provides comparable clinical-related and health-related questionnaire outcomes when compared with SB through 5 years of follow-up. However, the EB is related to a higher number of reinterventions. CLINICAL IMPACT: This present study is the first to report five-year outcomes comparing an endoluminal (EB) using heparin-bonded self-expanding covered stents with surgical bypass (SB) for long and complex femoropopliteal disease. Although the advantages of treatment with EB are mostly seen in the early period after treatment, the outcomes support the use of EB for this indication and seems to be a valid and safe alternative for bypass surgery. Future trials comparing various endovascular strategies may provide further guidance for the development of an evidence-based treatment algorithm.

7.
Eur J Vasc Endovasc Surg ; 68(1): 18-27, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38527519

RESUMO

OBJECTIVE: This study evaluated the long term outcomes of endovascular aneurysm repair using the Gore Excluder Low Permeability (LP) endoprosthesis across high volume Dutch hospitals. METHODS: A retrospective analysis was conducted of patients treated with the Excluder LP for infrarenal abdominal aortic aneurysm (AAA) in four hospitals between 2004 and 2017. Primary outcomes were overall survival, freedom from re-interventions (overall, inside and outside instructions for use, IFU), and AAA sac dynamics: growth (> 5 mm), stabilisation, and regression (< 5 mm). Secondary outcomes were technical success (device deployment), procedural parameters, and re-interventions. Follow up visits were extracted from patient files, with imaging assessed for complications and AAA diameter. RESULTS: Five hundred and fourteen patients were enrolled, with a median (IQR) follow up of 5.0 (2.9, 6.9) years. Survival rates were 94.0% at one year, 73.0% at five years, and 37.0% at 10 years, with freedom from re-interventions of 89.0%, 79.0%, and 71.0%, respectively. 37.9% were treated outside IFU, leading to significantly more re-interventions over 10 years compared with those treated inside IFU (36.0% vs. 25.0%, respectively; p = .044). The aneurysm sac regressed by 53.5% at one year, 65.8% at five years, and 77.8% at 10 years, and grew by 9.8%, 14.3%, and 22.2%, respectively. Patients with one year sac growth had significantly worse survival (p = .047). Seven patients (1.4%) had a ruptured aneurysm during follow up. Over 15 years, type 1a endoleak occurred in 5.3%, type 1b in 3.1%, type 3 in 1.9%, type 4 in 0.2%, and type 2 in 35.6% of patients. CONCLUSION: This multicentre study of real world endovascular aneurysm repair data using the Gore Excluder LP endoprosthesis demonstrated robust long term survival and re-intervention rates, despite 37.9% of patients being treated outside IFU, with type 4 endoleak being rare. Treatment outside IFU significantly increased re-intervention rates and one year sac growth was associated with statistically significantly worse survival.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Desenho de Prótese , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Masculino , Feminino , Idoso , Estudos Retrospectivos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Resultado do Tratamento , Idoso de 80 Anos ou mais , Países Baixos/epidemiologia , Fatores de Tempo , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Permeabilidade , Stents , Fatores de Risco , Hospitais com Alto Volume de Atendimentos , Reoperação/estatística & dados numéricos
8.
Artigo em Inglês | MEDLINE | ID: mdl-38670221

RESUMO

OBJECTIVE: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck. METHODS: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre- and post-operative CTAs to evaluate conformability of the CEXC. RESULTS: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was < 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR -2.3, 4.7; p = .042) at one year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR -0.5, 1.8; p = .019) at one year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m-1 (IQR 26, 56) and did not significantly change thereafter. CONCLUSION: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was achieved at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.

9.
Eur J Vasc Endovasc Surg ; 68(4): 469-477, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38871213

RESUMO

OBJECTIVE: One year aneurysm sac dynamics after endovascular abdominal aortic aneurysm repair (EVAR) were independently associated with a greater all cause mortality risk in prior registry studies but were limited in completeness and granularity. This retrospective analysis aimed to study the impact of sac dynamics on survival within the Endurant Stent Graft Global Registry (ENGAGE) with five year follow up. METHODS: A total of 1 263 subjects were enrolled in the ENGAGE Registry between March 2009 and April 2011. One year aneurysm sac changes were calculated between the one month post-operative imaging scans and the scan closest to the time of one year follow up. Sac regression was defined as a sac decrease of ≥ 5 mm and sac expansion as aneurysm sac growth ≥ 5 mm. The primary outcome was the five year all cause mortality rate. Kaplan-Meier estimates for freedom from all cause death were calculated. Multivariable Cox regression was used to determine the association between sac dynamics and all cause death. RESULTS: At one year, 441 of the 949 study participants with appropriate imaging (46%) had abdominal aortic aneurysm sac regression, 462 (49%) remained stable, and 46 (4.8%) had sac expansion. For patients with sac regression, the five year all cause mortality rate was 20%, compared with 28% for stable sac (p = .007) and 37% for the sac expansion (p = .010) cohorts. After adjustment, the sac expansion and stable sac cohorts were associated with a greater all cause mortality rate (expansion: hazard ratio [HR] 1.8; 95% CI 1.1 - 3.2; p = .032; stable: HR 1.4; 95% CI 1.1 - 1.9; p = .019). CONCLUSION: In the ENGAGE Global Registry, the one year rate of sac regression was 46%, and one year sac regression was observed to be associated with greater five year survival, corroborating prior findings using data from vascular registries. Sac regression could become the new standard for success after EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Sistema de Registros , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Masculino , Feminino , Estudos Retrospectivos , Idoso , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Implante de Prótese Vascular/mortalidade , Implante de Prótese Vascular/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Resultado do Tratamento , Stents , Prótese Vascular , Estimativa de Kaplan-Meier
10.
Ann Vasc Surg ; 106: 80-89, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38579908

RESUMO

BACKGROUND: The study aims to describe midterm outcomes following treatment of infrarenal abdominal aortic aneurysms (AAAs) with short necks by endosutured aneurysm repair using the Heli-FX EndoAnchor system. METHODS: This is a retrospective study of prospectively collected data from 9 vascular surgery departments between June 2010 and December 2019, including treated AAAs with neck lengths ≤10 mm. The decision for the use of EndoAnchors was made by the treating surgeon or multidisciplinary aortic committee according to each center's practice. There were 2 Groups further assessed according to neck length, A (≥4 and <7 mm) and B (≥7 and ≤10 mm). The main outcomes analyzed were technical success, freedom from type Ia endoleaks (TIaELs), sac size increase, all-cause and aneurysm-related mortality. RESULTS: Seventy-six patients were included in the study, 17 fell into Group A and 59 into Group B. Median follow-up for the cohort was 40.5 (interquartile range 12-61) months. A median of 6 (interquartile range 3) EndoAnchors were deployed in each subject. Technical success was 86.8% for the total group, 82.4% and 88.1% (P = 0.534) for Groups A and B respectively. Six out of 10 (60%) of TIaELs at the completion angiographies showed spontaneous resolution. Cumulative freedom from TIaEL at 3 and 5 years for the total group was 89% and 84% respectively; this was 93% and 74% for Group A and 88% at both intervals in Group B (P = 0.545). In total, there were 7 (9.2%) patients presenting with TIaELs over the entire study period. Two (11.8%) in Group A and 5 (8.5%) in Group B (P = 0.679). There were more patients with sac regression in Group B (Group A = 6-35.3% vs. Group B = 34-57.6%, P = 0.230) with no statistical significance. All-cause mortality was 19 (25%) patients, with no difference (4-23.5% vs. 15-25.4%, P = 0.874) between groups; whereas aneurysm-related mortality occurred in 1 patient from Group A and 3 from Group B. CONCLUSIONS: This study demonstrates reasonable outcomes for patients with short-necked AAAs treated by endosutured aneurysm repair in terms of TIaELs up to 5-year follow-up. EndoAnchor use should be judiciously evaluated in short necks and may be a reasonable option when anatomical constraints are encountered, mainly for those with 7-10 mm neck lengths. Shorter neck length aspects, as indicated by the results from Group A, may be an alternative when no other options are available or feasible.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Endoleak , Procedimentos Endovasculares , Desenho de Prótese , Sistema de Registros , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Estudos Retrospectivos , Masculino , Feminino , Idoso , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Fatores de Tempo , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Resultado do Tratamento , Idoso de 80 Anos ou mais , Endoleak/etiologia , Fatores de Risco , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/mortalidade , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA