Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 162
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Acta Radiol ; 65(1): 76-83, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37376763

RESUMO

BACKGROUND: Avascular osteonecrosis of the femoral head (AVN) often results in total hip arthroplasty (THA). The cause for increased THA revision rates among patients with AVN is not yet fully understood. PURPOSE: To perform a comparative radiological analysis of implant integration between patients with AVN and osteoarthritis (OA). MATERIAL AND METHODS: After a matched pair analysis of 58 patients, 30 received THA due to OA, 28 due to AVN. X-ray images were evaluated after one week ("baseline") and on average 37.58 months postoperatively ("endline"). The prosthesis was grouped into 10 regions of interest (ROI): seven femoral and three acetabular. Incidence, width, and extent of "radiolucent lines" were measured within each zone. RESULTS: Between baseline and endline, width and extent progressed more noticeably in all femoral and acetabular zones among patients with AVN. In femoral ROI 1, the width increased in 40% of AVN cases compared to 6.7% of OA cases. For acetabular ROI 3, the width increased in 26.7% of AVN cases compared to no perceived changes in the OA group. No signs of prosthetic loosening were found in the AVN group. CONCLUSION: The increase of width and extent of radiolucent lines over time in patients with AVN could be a sign of lack of osteointegration. However, prosthetic loosening in absence of clinical symptoms cannot be deduced from radiological findings after medium-term postoperative follow-up. Further long-term studies are required to monitor how radiolucent lines develop in respect to long-term implant loosening. Dependent on bone quality, individually adapted reaming and broaching of the implant site are recommended.


Assuntos
Artroplastia de Quadril , Necrose da Cabeça do Fêmur , Prótese de Quadril , Osteoartrite , Humanos , Prótese de Quadril/efeitos adversos , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/cirurgia , Cabeça do Fêmur , Resultado do Tratamento , Falha de Prótese , Estudos Retrospectivos
2.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 929-940, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38426599

RESUMO

PURPOSE: To investigate whether concomitant autologous bone grafting adversely affects clinical outcome and graft survival after matrix-associated autologous chondrocyte implantation (M-ACI). METHODS: The present study examines registry data of patients who underwent M-ACI with or without autologous bone grafting for large-sized chondral or osteochondral defects. Propensity score matching was performed to exclude potential confounders. A total of 215 patients with similar baseline characteristics were identified. Clinical outcome was assessed at the time of surgery and at 6, 12, 24, 36 and 60 months using the Knee Injury and Osteoarthritis Outcome Score (KOOS). KOOS change, clinical response rate, KOOS subcomponents and failure rate were determined. RESULTS: Patients treated with M-ACI and autologous bone grafting achieved comparable clinical outcomes compared with M-ACI alone. At 24 months postoperatively, the patient-reported outcome (PRO) of patients treated with M-ACI and autologous bone grafting was even significantly better as measured by KOOS (74.9 ± 18.8 vs. 79.2 ± 15.4; p = 0.043). However, the difference did not exceed the minimal clinically important difference (MCID). In patients with M-ACI and autologous bone grafting, a greater change in KOOS relative to baseline was observed at 6 (9.3 ± 14.7 vs. 15.0 ± 14.7; p = 0.004) and 12 months (12.6 ± 17.2 vs. 17.7 ± 14.6; p = 0.035). Overall, a high clinical response rate was observed in both groups at 24 months (75.8% vs. 82.0%; p = n.s.). The estimated survival at the endpoint of reoperation for any reason was 82.1% (SD 2.8) at 8.4 years for isolated M-ACI and 88.7% (SD 2.4) at 8.2 years for M-ACI with autologous bone grafting (p = 0.039). CONCLUSIONS: Even in the challenging cohort of large osteochondral defects, the additional treatment with autologous bone grafting leads to remarkably good clinical outcomes in patients treated with M-ACI. In fact, they tend to benefit more from surgery, have lower revision rates and achieve clinical response rates earlier. Subchondral bone management is critical to the success of M-ACI and should be addressed in the treatment of borderline defects. LEVEL OF EVIDENCE: Level III.


Assuntos
Cartilagem Articular , Condrócitos , Humanos , Condrócitos/transplante , Transplante Ósseo , Cartilagem Articular/cirurgia , Articulação do Joelho/cirurgia , Transplante Autólogo/métodos , Sistema de Registros
3.
Artigo em Inglês | MEDLINE | ID: mdl-38643391

RESUMO

PURPOSE: To determine the superior spacer design, a growing number of studies are comparing treatment results between patients having been treated with articulating and static knee spacers in the setting of two-stage revision for periprosthetic joint infection (PJI). In contrast, the primary objective of this study was to compare preoperative characteristics between patients from both spacer groups and examine whether significant differences were present prior to spacer implantation. METHODS: This retrospective, single-centre, cohort study examined the preoperative situation of 80 consecutive knee PJIs between 2017 and 2020. All patients underwent two-stage revision, with 35 (44%) receiving an articulating and 45 (56%) a static spacer. RESULTS: No significant differences were observed in terms of patient gender (p = 0.083), age (p = 0.666), comorbidity (p = 0.1) and preoperative clinical function (p = 0.246). Static spacers were significantly more often used in the presence of a periarticular fistula (p = 0.033), infection of a revision implant (p < 0.001), higher degree of bone loss (p < 0.001) and infection caused by a difficult-to-treat pathogen (p = 0.038). Complication and revision rates were similar for both spacer types during the interim period, while patients with articulating spacers demonstrated a superior clinical function (p < 0.001) during the interim period and after reimplantation. CONCLUSION: Static spacers are being utilised in significantly more complex and unfavourable preoperative scenarios. Therefore, a preoperative selection bias may be at least partially accountable for any disparities observed in postoperative outcomes. To achieve the best possible results, surgeons should know and respect the distinct indications of static and articulating spacers and consequently understand and use them as complementary surgical options. LEVEL OF EVIDENCE: Level III.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38738859

RESUMO

PURPOSE: The aim of this study was to evaluate the role of leg alignment on long-term clinical outcome after matrix-associated autologous chondrocyte implantation (M-ACI) and to define an individualized target range to optimize clinical outcome. METHODS: The present study examined patients who underwent M-ACI of the femoral condyle. The Knee Injury and Osteoarthritis Outcome Score (KOOS) and Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) were used to assess the results. Clinical outcomes were related to Patient Acceptable Symptomatic State (PASS). For intra- and interobserver reliability of mechanical tibiofemoral angle, mechanical medial proximal tibial angle and mechanical lateral distal femoral angle, we calculated intraclass correlation coefficients using a two-way mixed model with absolute agreement. A regression model and receiver-operating characteristics curve were used to identify an individual range of alignment where a favourable clinical outcome could be expected in the long term. RESULTS: Additional osteotomy was performed in 50% of patients with similar clinical outcomes as physiologically aligned patients (p > 0.05). The curve-fitting regression model identified a target range of -2.5° valgus to 4.5° varus for ideal postoperative alignment (R2 = 0.12, p = 0.01). Patients within this range were more likely to achieve PASS (70% vs. 27%, p = 0.001). In medially treated defects, a refined range of -2.5° valgus to 4° varus alignment was found (R2 = 0.15, p = 0.01). These patients were more likely to achieve PASS (67% vs. 30%, p = 0.01) and showed favourable postoperative KOOS and MOCART scores (p = 0.02). Patients with lateral defects were more likely to achieve PASS within a range of -2° valgus and 0.5° varus (90% vs. 45%, p = 0.03) and showed favourable postoperative KOOS and MOCART scores (p = not significant). CONCLUSIONS: An individual range of leg alignment-whether achieved by osteotomy or physiologic alignment-should be respected in M-ACI treatment. A neutral to slightly undercorrected alignment favours the postoperative outcome after M-ACI. When planning surgery for patients with focal cartilage defects of the femoral condyle, these ranges should be recognized as critical factors. LEVEL OF EVIDENCE: Level III.

5.
J Shoulder Elbow Surg ; 33(4): e175-e184, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37652214

RESUMO

BACKGROUND: To reduce hardware-related complications in coracoid graft fixation to the anterior aspect of the glenoid, a metal-free Latarjet technique was recently introduced. The aim of this study was to compare the primary stability of a classic Latarjet procedure with 2 metal screws to a novel metal-free, all-suture cerclage method. It is hypothesized that fixation of the coracoid graft with 2 malleolar screws will provide higher primary stability compared with an all-suture cerclage technique. METHODS: This biomechanical in vitro study was conducted on 12 fresh-frozen cadaveric shoulders (6 matched pairs) with a mean donor age of 80 years (range, 67-89 years). Coracoid graft fixation was performed using a recently introduced all-suture cerclage technique (group A) or a classic Latarjet technique with two 4.5-mm malleolar screws (group B). The conjoint tendon was loaded with a static force of 10 N to simulate the sling effect. Graft loading with a probe head consisted of 6 ascending load levels (10-50 N, 10-100 N, 10-150 N, 10-200 N, 10-250 N, and 10-300 N) with 100 cycles each at 1 Hz. Relative motion of the bone graft to the glenoid was measured using an optic 3-dimensional system. RESULTS: While loading the conjoint tendon with 10 N, no difference in mean displacement of the bone-graft was found between both groups (P = .144). During cyclic loading, a significant difference in relative displacement for both groups was already detected in load level 1 (group A: 2398.8 µm vs. group B: 125.7 µm; P = .024), and this trend continued with the following load levels (P < .05). DISCUSSION AND CONCLUSION: The study demonstrated that the innovative metal-free, all-suture cerclage fixation technique results in higher micromotion than the classic coracoid graft fixation with 2 malleolar screws. According to the present biomechanical investigation, shoulders treated with a metal-free all-suture cerclage technique might need adapted rehabilitation protocols to protect the construct and allow for graft healing.


Assuntos
Bursite , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Idoso , Idoso de 80 Anos ou mais , Articulação do Ombro/cirurgia , Transplante Ósseo , Escápula/cirurgia , Luxação do Ombro/cirurgia , Suturas , Fenômenos Biomecânicos , Instabilidade Articular/cirurgia
6.
J Arthroplasty ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38823519

RESUMO

INTRODUCTION: The reconstruction of acetabular defects in total hip arthroplasty (THA) can be challenging. An option to treat uncontained acetabular defects is to use modular tantalum augments in combination with cementless press-fit cups. However, modularity is associated with an increased risk of debonding and mechanical failure. In addition, metal wear particles can be released due to micromotions at the implant interface. Clinical data on the long-term results of this treatment strategy is limited. The purposes of this study were: (1) to evaluate the clinical and radiological outcome of complex THA using modular trabecular metal augments and uncemented revision cups; (2) to investigate the blood tantalum concentrations in these patients at mid-term (mean 4.5 year) follow-up; and (3) to report complications and mechanisms of failure related to this procedure. MATERIALS AND METHODS: In this single-center study, we retrospectively reviewed data from a consecutive cohort of 27 patients who underwent complex acetabular defect reconstruction using a modular tantalum acetabular augment in combination with an uncemented tantalum cup. We evaluated the implant survival, and the radiological and clinical outcomes after a mean follow-up of 4.5 years (SD 2.1; range 2.5 to 10.6 years) using patient-reported outcome scores (PROMs). Blood samples were analyzed regarding tantalum concentration and compared with a control group. RESULTS: The cumulative survival rate at 4.5 years with the endpoint "revision of the acetabular component for aseptic loosening" was 94.4% (95% confidence interval (CI) 71.6 to 99.2) and 82.9% (95 % CI 60.5 to 93.3) for the endpoint "revision for any reason." The PROMs improved significantly up to the latest follow-up, and radiographic data showed no signs of loosening or implant migration. Median blood tantalum concentrations were significantly higher in the study group (0.15 µg/L) compared to the control group (0.002 µg/L) (P < 0.001). CONCLUSIONS: This study demonstrated acceptable clinical and radiological results of cementless revision THA using modular trabecular metal implants for the reconstruction of large acetabular defects. Tantalum concentrations were significantly higher in patients who had tantalum implants compared to the control group, however, the systemic and local effects of an increased tantalum exposure are not yet fully understood and have to be further investigated.

7.
J Arthroplasty ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38460739

RESUMO

BACKGROUND: Spinopelvic characteristics, including sacral slope (SS), are commonly evaluated in different positions pre-total hip arthroplasty (THA). This study aimed to: 1) investigate the change in spinopelvic parameters at 7 days (early) and 1-year post-THA; and 2) identify patient characteristics associated with a change in SS of more than 7° post-THA. METHODS: We prospectively studied 250 patients who underwent unilateral THA [132 women, age 66 years (range, 32 to 88)] and underwent biplanar images preoperatively and at 7 days and 1-year post-THA. Parameters measured included pelvic incidence, standing lumbar lordosis, SS, and proximal femoral angle (PFA). A SS change ≥ 7° was considered the threshold as it would result in more than a 5° change in cup orientation. RESULTS: Early post-THA SSstanding remained within ± 6º from preoperative measurements in 75% of patients, reduced by ≥ 7° in 9%, and increased by ≥ 7° in 16%. Those that showed a reduction in SS had the lowest PFA and the highest SS pre-THA (P = .028, .107, and < 0.001, respectively). From 7 days until the 1-year mark, pelvic tilt increased, SS reduced (mean: -4º, range: -29 to 17º, P < .001), and patients stood with greater hip extension ΔPFAstanding (mean 7°, range: -34 to 37°, P < .001). At 1 year, SSseated had remained within ± 6º, relative to the pre-THA value, in 49% of patients. CONCLUSIONS: Standing spinopelvic characteristics, especially SSstanding, remain within ±6° in three-quarters of patients both early- and at 1-year post-THA. In the remaining cases, pelvic tilt changes significantly. In 9% of cases, SS reduces ≥ 7° early THA, probably due to the alleviation of fixed-flexion contractures. The SSseated changes by ≥ ± 7° in almost 50% of cases in this study, and its clinical value as a preoperative planning tool should be questioned. LEVEL OF EVIDENCE: Level II, diagnostic study.

8.
Arch Orthop Trauma Surg ; 144(3): 1369-1377, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37872437

RESUMO

INTRODUCTION: Modular femoral components allow for patient-specific restoration of hip joint geometry and the reconstruction of extensive bone defects in revision total hip arthroplasty (THA); however, potential problems of modular implants such as taper corrosion and the risk of implant fracture continue to be of concern. The aim of the present study was to evaluate the clinical and radiological results of a cementless modular revision stem following revision surgery due to aseptic loosening and periprosthetic fracture and to assess patient-reported outcome measures (PROMs) in these patients at mid-term follow-up. MATERIALS AND METHODS: In this study, a consecutive cohort of 75 patients who underwent primary revision THA at our institution using a modular cementless stem design (MRP-TITAN stem) was retrospectively evaluated at a mean follow-up of 7.7 years. Kaplan-Meier survivorship analyses were performed with revision of the femoral component for any reason as the end point. The Harris-Hip Score, the UCLA Activity Score, the Forgotten Joint Score and the SF-12 Score were used for clinical assessment. We used the Wilcoxon signed rank test to compare pre- and postoperative clinical scores. RESULTS: Overall stem survival with the endpoint stem re-revision for any reason was 85.4% at a mean follow-up of 7.7 years (range 2.4-14 years). Stem survival was 89.5% in the aseptic loosening group and 78.3% in the periprosthetic fracture group with no statistically significant difference between both groups (p = 0.107). One patient had to be revised due to taper fracture. PROMs improved significantly up to the latest follow-up, and radiographic evaluation showed full osseointegration of all stems in this cohort. CONCLUSIONS: Revision THA using a modular cementless titanium revision stem demonstrated adequate clinical and radiological results at mid- to long-term follow-up in this cohort. Cementless revision stems are a useful treatment option to restore the anatomy, especially in deformed hips and in complex revision hip arthroplasty. However, there are some significant disadvantages related to an increased risk of mechanical failure such as corrosion/fretting damage and implant fracture. Future high-quality prospective studies with longer follow-up are necessary to confirm the supposed advantages.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/efeitos adversos , Seguimentos , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/etiologia , Estudos Retrospectivos , Estudos Prospectivos , Desenho de Prótese , Reoperação , Falha de Prótese , Resultado do Tratamento
9.
BMC Musculoskelet Disord ; 24(1): 400, 2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37202754

RESUMO

INTRODUCTION: Conventional polyethylene (PE) wear has been reported to be associated with femoral offset reconstruction and cup orientation after THA. Thus, the present study aimed (1) to determine the polyethylene wear rate of 32 mm ceramic heads with highly cross-linked polyethylene (HXLPE) inlays up to 10 years postoperatively and (2) to identify patient and surgery-related factors affecting the wear rate. METHODS: A prospective cohort study was performed, investigating 101 patients with 101 cementless THAs and ceramic (32 mm) on HXLPE bearings after 6-24 months, 2-5 years and 5-10 years postoperatively. The linear wear rate was determined using a validated software (PolyWare®, Rev 8, Draftware Inc, North Webster, IN, USA) by two reviewers, blinded to each other. A linear regression model was used to identify patient and surgery-related factors on HXLPE -wear. RESULTS: After an initial bedding-in phase of 1 year after surgery, the mean linear wear rate was 0.059 ± 0.031 mm/y at ten years (mean 7.7 years; SD 0.6 years, range 6-10), being below the osteolysis relevant threshold of 0.1 mm/year. The regression analysis demonstrated that age at surgery, BMI, cup inclination or anteversion and the UCLA score were not associated with the linear HXLPE-wear rate. Only increased femoral offset showed a significant correlation with an increased HXLPE-wear rate (correlation coefficient of 0.303; p = 0.003) with a moderate clinical effect size (Cohen's f²=0.11). CONCLUSION: In contrast to conventional PE inlays, hip arthroplasty surgeons may be less concerned about osteolysis-related wear of the HXLPE if the femoral offset is slightly increased. This allows focusing on joint anatomy reconstruction, hip stability and leg length.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Humanos , Polietileno , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Estudos Prospectivos , Osteólise/cirurgia , Cabeça do Fêmur/cirurgia , Falha de Prótese , Cerâmica , Desenho de Prótese , Seguimentos
10.
BMC Musculoskelet Disord ; 24(1): 51, 2023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-36670400

RESUMO

BACKGROUND: The majority of knee endoprostheses are cemented. In an earlier study the effects of different cementing techniques on cement penetration were evaluated using a Sawbone model. In this study we used a human cadaver model to study the effect of different cementing techniques on relative motion between the implant and the femoral shaft component under dynamic loading. METHODS: Two different cementing techniques were tested in a group of 15 pairs of human fresh frozen legs. In one group a conventional cementation technique was used and, in another group, cementation was done using a pressurizing technique. Under dynamic loading that simulated real life conditions relative motion at the bone-implant interface were studied at 20 degrees and 50 degrees flexion. RESULTS: In both scenarios, the relative motion anterior was significantly increased by pressure application. Distally, it was the same with higher loads. No significant difference could be measured posteriorly at 20°. At 50° flexion, however, pressurization reduced the posterior relative motion significantly at each load level. CONCLUSION: The use of the pressurizer does not improve the overall fixation compared to an adequate manual cement application. The change depends on the loading, flexion angle and varies in its proportion in between the interface zones.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Cimentos Ósseos , Próteses e Implantes
11.
Ultraschall Med ; 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-37820695

RESUMO

PURPOSE: Soft tissue tumors (STT) are difficult to diagnose accurately, and distinguishing between benign and malignant tumors is challenging. Lipoma is the most common STT, while atypical lipomatous tumors (ALT) can dedifferentiate into malignant lipomatous tumors like grade 1 liposarcoma and require more radical therapy. This study aims to investigate the potential of contrast-enhanced ultrasound (CEUS) to differentiate between lipoma and ALT based on tumor perfusion. MATERIALS AND METHODS: We prospectively examined 52 patients who were scheduled for biopsy for suspected lipoma or ALT. The CEUS examination was performed using SonoVue as a contrast agent to quantify tumor perfusion using VueBox V7.1 software. Peak enhancement (PE), rise time (RT), wash-in perfusion index (WiPI), and wash-out rate (WoR) were used to assess contrast enhancement inside the STT. RESULTS: Among 50 tumors examined, 30 were lipomas, and 20 were ALTs. We found significant differences in perfusion between lipomas and ALTs (PE: 49.22 ± 45.75 a.u. vs. 165.67 ± 174.80; RT: 23.86 ± 20.47s vs. 10.72 ± 5.34 s; WiPI: 33.06 ± 29.94 dB vs. 107.21 ± 112.43 dB; WoR: 2.44 ± 3.70 dB/s vs. 12.75 ± 15.80 dB/s; p<.001). ROC analysis of PE resulted in a diagnostic accuracy of 74% for the detection of an ALT, and 77% for the detection of a lipoma. CONCLUSION: CEUS may enhance the differential diagnosis of benign lipomas and ALTs, with ALTs showing higher levels of perfusion. If larger prospective studies confirm these findings, CEUS could enhance diagnostic accuracy, guide surgical planning, and potentially reduce unnecessary treatments for patients presenting with ambiguous lipomatous tumors like lipoma or ALT.

12.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3947-3955, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37093235

RESUMO

PURPOSE: Due to low incidence of isolated lateral osteoarthritis (OA), there are limited data on whether a fixed-bearing (FB) or a mobile-bearing (MB) design is superior for lateral unicompartmental knee replacement (UKR). The aim of this matched-pairs analysis was to compare both designs in terms of implant survival and clinical outcome. METHODS: Patients who received MB-UKR (Group A) and FB-UKR (Group B) at a single centre were matched according to gender, age at time of surgery and body mass index (BMI). Survivorship analysis was performed with the endpoint set as "revision for any reason". Clinical outcome was assessed using the Oxford knee score (OKS), visual analogue scale for pain (VAS), patients' satisfaction, University of California Los Angeles activity scale (UCLA) and the Tegner activity score (TAS). RESULTS: A total of 60 matched pairs were included with a mean follow-up (FU) of 3.4 ± 1.3 (range 1.2-5.0) years in Group A and 2.7 ± 1.2 (range 1.0-5.0) years in Group B. Survivorship between both groups differed significantly (Group A: 78.7%; Group B: 98.3%, p = 0.003) with bearing dislocation being the most common reason for revision in Group A (46.2%). The relative and absolute risk reduction were 92.2% and 20%, respectively, with 5 being the number needed to treat. There were no differences in OKS (Group A: 41.6 ± 6.5; Group B: 40.4 ± 7.7), VAS (Group A: 2.9 ± 3.2; Group B: 1.6 ± 2.2), UCLA (Group A: 5.7 ± 1.3; Group B: 5.9 ± 1.8) and TAS (Group A: 3.0 ± 1.0; Group B: 3.1 ± 1.2) between both groups on follow-up. CONCLUSION: Despite modern prosthesis design and surgical technique, implant survival of lateral MB-UKR is lower than that of FB-UKR on the short- to mid-term due to bearing dislocation as the most common cause of failure. Since clinical results are equivalent in both groups, FB-UKR should be preferred in treatment of isolated lateral OA. LEVEL OF EVIDENCE: Retrospective case-control study, Level III.


Assuntos
Artroplastia do Joelho , Luxações Articulares , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Estudos de Casos e Controles , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Reoperação , Desenho de Prótese , Luxações Articulares/cirurgia , Dor/cirurgia , Resultado do Tratamento , Articulação do Joelho/cirurgia
13.
Int Orthop ; 47(11): 2655-2661, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37566227

RESUMO

PURPOSE: Antibiotic loaded bone cement spacers provide high local antibiotic concentrations, preserve bone stock, and reduce soft tissue contractions. The objective of this in-vitro study was to compare antibiotic release from spacers, aiming to discover the most optimal preparation and identify modifiable factors that can further enhance antibiotic release. METHODS: Six distinct spacer preparation were created using three different bone cements and manual incorporation of antibiotics. During a six-week period, the release of antibiotics from each spacer was measured individually at ten predetermined time points using a chemiluminescent immunoassay. RESULTS: Manually adding 4 g of vancomycin to every 40 g of "Palacos R + G" yielded the most favorable release profile. Throughout all preparations, antibiotic release consistently and significantly decreased over the six-week period. When incorporating a higher concentration of vancomycin, a significantly higher cumulative release of vancomycin was observed, with varying effects on the release of gentamicin. The choice of bone cement had a significant impact on antibiotic release. CONCLUSION: To enhance antibiotic release from spacers, surgeons should manually incorporate high antibiotic concentrations into the most appropriate bone cement and keep the interim period as short as possible. Specifically, we suggest manual incorporation of 4 g of vancomycin to every 40 g of gentamicin premixed "Palacos R + G" to create bone cement spacers.


Assuntos
Artrite Infecciosa , Infecções Relacionadas à Prótese , Humanos , Antibacterianos/uso terapêutico , Vancomicina , Cimentos Ósseos , Polimetil Metacrilato , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/cirurgia , Gentamicinas
14.
Arch Orthop Trauma Surg ; 143(5): 2747-2754, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35788763

RESUMO

INTRODUCTION: A rare catastrophic failure of modular component Total Hip Arthroplasty is dissociation between liner and cup, which has been associated with component malposition and/or impingement and seems to be more frequently associated with the Pinnacle system. The goal of this study was to evaluate the resistance of a polyethylene liner to lever-out-forces of the Pinnacle locking mechanism and the locking mechanisms of two other current cup/liner systems using a standardized testing method (ASTM). MATERIALS AND METHODS: Five of each of the following cups were evaluated with their corresponding polyethylene liners: Pinnacle Multihole cup with and without intact anti-rotation tabs (ART's); Allofit-S-Alloclassic and Plasmafit Plus7 cups. The ASTM test set-up was used to evaluate the lever-out force resulting in liner dissociation for each construct. RESULTS: The Pinnacle construct with intact ARTs required the greatest force (F) to achieve dissociation (263.2 ± 79.2 N) followed by the Plasmafit Plus7 (185.8 ± 36.9 N) and the Allofit-S (101.4 ± 35.3 N) constructs, respectively. However, after removal of the ARTs, the Pinnacle system required the least force to achieve dissociation (75.1 ± 22.2 N) (p < 0.001). CONCLUSIONS: The intact Pinnacle system appeared the most stable in lever-out tests when compared to the other systems. However, after removal of the ARTs, the Pinnacle system required the least force for dissociation, consistent with locking mechanism failure, and suggesting that the ARTs are a critical component of the locking mechanism. Our findings are consistent with the clinical experience of dissociated Pinnacle constructs displaying damaged or missing ARTs, and that damage to these may increase risk of liner dissociation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Reoperação , Polietileno , Desenho de Prótese , Acetábulo/cirurgia
15.
Arch Orthop Trauma Surg ; 143(8): 4713-4719, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36656351

RESUMO

INTRODUCTION: Avascular osteonecrosis of the femoral head (AVN) is a widespread disease affecting mostly young and active people, often exacerbating in progressive stages, ending in joint replacement. The most common joint preserving operative therapy for early stages is core decompression (CD), optional with cancellous bone grafting (CBG). For success it is vital that the necrotic area is hit and the sclerotic rim is broken by drilling into the defect zone to relieve intraosseous pressure. The aim of this study was to investigate if both techniques are precise enough to hit the center of the necrosis and if there is a difference in precision between drilling with small pins (CD) and the trephine (CBG). PATIENTS AND METHODS: 10 patients underwent CD, 12 patients CBG with conventional C-arm imaging. Postoperatively 3D MRI reconstructions of the necrotic area and the drilling channels were compared. The deviation of the drilling channel from the center of the necrotic area was measured. PROMs (HHS, HOOS, EQ-5D, SF-36) were evaluated to compare the clinical success of these procedures. RESULTS: Neither with CD nor with CBG the defect zone was missed. The drilling precision of both procedures did not differ significantly: distance to center 3.58 mm for CD (range 0.0-14.06, SD 4.2) versus 3.91 mm for CBG (range 0.0-15.27, SD 4.7). PROMs showed no significant difference. CONCLUSION: Concerning the most important difference between the two procedures-the surgical higher demanding technique of CBG-we suggest applying the less invasive technique of CD alone.


Assuntos
Artroplastia de Substituição , Necrose da Cabeça do Fêmur , Humanos , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/cirurgia , Resultado do Tratamento , Cabeça do Fêmur/cirurgia , Osso Esponjoso/cirurgia , Descompressão Cirúrgica/métodos
16.
Arch Orthop Trauma Surg ; 143(9): 5849-5856, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36917240

RESUMO

INTRODUCTION: The aim of the current study was to demonstrate short- to mid-term survivorship as well as clinical outcome of lateral unicompartmental knee replacement (UKR) with a fixed-bearing (FB) design from a non-designer center using the Oxford Fixed Lateral prosthesis. MATERIALS AND METHODS: This single-center retrospective cohort study reports the results of 133 consecutive lateral FB-UKR. Survivorship analysis was performed with different endpoints and clinical outcome was measured using the Oxford-Knee-Score (OKS), American-Knee-Society-Score (AKSS-O), range-of-motion (ROM) and visual-analog-scale for pain (VAS). RESULTS: There were two revision surgeries with conversion to total knee replacements (TKR) due to persistent pain resulting in a survival rate of 98.5% (95% CI 93.5-99.6) with a mean follow-up (FU) of 3.3 ± 1.8 years (range 1-8.5). All outcome scores, VAS and ROM showed a significant improvement at final FU (p < 0.001). The OKS improved from 26 ± 7.8 (range 11-45) preoperatively to 39 ± 8.3 (range 13-48), the AKSS-O from 49.2 ± 14.6 (range 18-90) to 81.8 ± 15.1 (range 40-100), the AKSS-F from 53 ± 23.7 (range 0-100) to 80.4 ± 21.4 (range 5-100) and the ROM from 118 ± 17 (range 90-160) to 134 ± 9.5 (range 100-155). CONCLUSIONS: The short- to mid-term results following lateral FB-UKR demonstrate a high survivorship and good clinical outcome from an independent series. We, therefore, suggest that FB-UKR is a safe treatment option for isolated lateral OA if sufficient surgical experience is provided. LEVEL OF EVIDENCE: Retrospective cohort study, level IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento , Reoperação , Dor/cirurgia , Articulação do Joelho/cirurgia , Seguimentos
17.
Arch Orthop Trauma Surg ; 143(6): 3383-3389, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36171340

RESUMO

INTRODUCTION: The aim of the present study was to compare clinical outcome between patients following fixed-bearing (FB) or mobile-bearing (MB) unicompartmental knee replacement (UKR) for antero-medial knee osteoarthrosis (OA) at two independent orthopedic centers. MATERIALS AND METHODS: Matched-pairs were built between 35 patients receiving FB-UKR and 52 patients following MB-UKR regarding age at time of surgery, body mass index (BMI) and range of motion (ROM) preoperatively. Clinical and functional outcome was measured postoperatively by the American Knee Society Score (AKSS-O/AKSS-F), ROM, Tegner Activity Scale (TAS) as well as the Short Form 36 Health Survey (SF-36). RESULTS: The average treatment effect of the treated (ATT) after propensity score matching showed a significantly superior ROM in patients following MB-UKR (FB: 118°, MB: 124°). All remaining parameters had no statistically significant differences between both groups involving TAS, AKSS and SF-36. CONCLUSIONS: The present study suggests that MB-UKR can provide a greater ROM compared to FB-UKR on comparable patients. The authors believe that both designs are suitable for adequate improvement of clinical outcome and ROM for patients suffering from antero-medial osteoarthrosis of the knee joint. LEVEL OF EVIDENCE: Retrospective cohort study, Level IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Estudos Retrospectivos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
18.
Acta Orthop ; 94: 321-327, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37409417

RESUMO

PURPOSE: We aimed to determine the minimum 20-year survival rates of a cementless press-fit cup in young patients. PATIENTS AND METHODS: This is a retrospective, single-center, multi-surgeon cohort study investigating the minimum 20-year clinical and radiological outcome of the first 121 consecutive total hip replacements (THRs) using a cementless, press-fit cup (Allofit, Zimmer, Warsaw, IN, USA) performed between 1999 and 2001. 28-mm metal-on-metal (MoM) and ceramic-on-conventionally not highly crosslinked polyethylene (CoP) bearings were used in 71% and 28%, respectively. Median patient age at surgery was 52 (range 21-60) years. Kaplan-Meier survival analysis was conducted for different endpoints. RESULTS: The 22-year survival rate for the endpoint aseptic cup or inlay revision was 94% (95% confidence interval [CI] 87-96) and 99% (CI 94-100) for aseptic cup loosening. 20 patients (21 THRs; 17%) had died and 5 (5 THRs; 4%) were lost to follow-up. No THR showed evidence of radiographic cup loosening. Osteolysis was observed in 40% of THRs with MoM and 77% with CoP bearings. 88% of THRs with CoP bearings showed significant polyethylene wear. CONCLUSION: The investigated cementless press-fit cup, which is still in clinical use today, showed excellent long-term survival rates in patients under the age of 60 years at surgery. However, osteolysis due to polyethylene and metal wear was frequently observed and is a matter of concern in the third decade after surgery.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Seguimentos , Estudos Retrospectivos , Estudos de Coortes , Falha de Prótese , Metais , Polietileno , Desenho de Prótese , Reoperação
19.
Arch Phys Med Rehabil ; 103(9): 1699-1706, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35288097

RESUMO

OBJECTIVE: To investigate the relationship of frontal plane ankle mobility with the effects of an ankle-foot orthosis (AFO) and a laterally wedged insole (LWI) on knee adduction moment (KAM) in the treatment of medial knee osteoarthritis. DESIGN: Randomized, nonblinded crossover trial. SETTING: Outpatient clinic of university hospital. PARTICIPANTS: Referred sample of 20 patients (N=20) with medial knee osteoarthritis stage 1-3 (Kellgren and Lawrence), aged 56.4±6.5 years; 58 patients were assessed, 21 were included, and 1 was a dropout. There were 14 healthy reference participants without knee osteoarthritis (convenience sample) who were matched by age. INTERVENTIONS: Patients received AFO and LWI for 6 weeks each with gait analysis after each 6-week intervention. Patients underwent additional barefoot gait analysis, walking on even ground and on a cross slope of 5° lateral elevation and standing on inclinations of 0°, 5°, 10°, and 20°. MAIN OUTCOME MEASURES: Spearman correlation between the immediate change in first peak of KAM with each aid and the change in hindfoot varus on the cross slope relative to level ground. RESULTS: The KAM reduction with AFO correlated significantly with hindfoot varus reaction to the cross slope during walking: the greater the hindfoot valgization on the cross slope, the greater the KAM reduction with AFO (Spearman ρ=0.53, P=.02). The KAM reduction with LWI correlated moderately negatively with the change in hindfoot varus: the greater the hindfoot valgization on the cross slope, the smaller the KAM reduction with LWI (r=-0.31 P=.18). CONCLUSIONS: LWI may be suitable for patients with limited to normal frontal plane ankle mobility. Patients with greater frontal plane ankle mobility benefit most from frontal plane ankle bridging with AFO. Studies with larger samples are necessary.


Assuntos
Órtoses do Pé , Osteoartrite do Joelho , Tornozelo , Fenômenos Biomecânicos , Marcha , Humanos , Articulação do Joelho , Osteoartrite do Joelho/terapia , Sapatos
20.
Acta Radiol ; 63(5): 698-705, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33982602

RESUMO

BACKGROUND: Computed tomography (CT) is the gold standard for the accurate measurement of cup inclination and anteversion in total hip arthroplasty (THA). However, functional cup position strongly depends on the tilt of the pelvis and thus pelvic tilt in the supine position on the CT table harbors the risk of misinterpretation. PURPOSE: To evaluate the influence of pelvic tilt on cup measurements in postoperative CT scans. MATERIAL AND METHODS: This is a secondary outcome analysis of a prospective study. In 123 patients undergoing THA, anatomic cup inclination and anteversion as measured on postoperative 3D-CT scans were compared between: (i) the anterior pelvic plane (APP) resembling neutral pelvic tilt; and (ii) the coronal plane representing the standard planes on CT. Furthermore, the effect of the variation on cup positions within Lewinnek's safe zone in relation to the applied reference plane was assessed. RESULTS: Mean pelvic tilt in supine position was -3.5° ± 5.6°. This resulted in a mean difference for anteversion between APP und coronal plane of 2.1° ± 3.7° and of 2.1° ± 1.9° for cup inclination, respectively. The change varied up to 20.2° for cup inclination and up 12.2° for cup anteversion. The overall conversion rate for inclination and/or anteversion regarding Lewinnek's safe zone was high at 23.6% (29/123). CONCLUSION: Pelvic tilt affects cup orientation on CT scans depending on the applied reference plane. Standard CT planes should be corrected regarding pelvic tilt before measurements to avoid errors in measurement.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Humanos , Estudos Prospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA