Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Nutr ; 154(9): 2827-2833, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39019166

RESUMO

BACKGROUND: Omega-3 fatty acids derived from seafood acids may influence cardiac arrhythmogenesis, whereas the role of the major plant-derived omega-3 fatty acid, alpha-linolenic acid (ALA), on atrial fibrillation (AF) is largely unknown. OBJECTIVES: We aimed to investigate the association between ALA intake and risk of incident AF overall and in subjects with a low intake of marine omega-3 fatty acids. METHODS: We followed a total of 54,260 middle-aged men and women enrolled into the Danish Diet, Cancer, and Health cohort for development of AF using nationwide registries. Intake of ALA was assessed using a validated food frequency questionnaire and modeled as a restricted cubic spline. Statistical analyses were conducted using Cox proportional hazards regression. RESULTS: We identified a total of 4902 incident AF events during a median of 16.9 y of follow-up. In multivariable analyses, we observed indications of a statistically nonsignificant inverse association between ALA intake and risk of AF up to an ALA intake of 2.5 g/d, whereas no appreciable association was found for higher intakes of ALA. A statistically significant dose-dependent negative association was found between ALA intake and risk of AF in individuals consuming < 250 mg marine omega-3 fatty acids daily, whereas no association was found in those with a higher intake of marine omega-3 fatty acids. CONCLUSIONS: Intake of ALA was associated with a lower risk of AF in individuals consuming a low intake of marine omega-3 fatty acids. This finding is novel and warrants further investigation.


Assuntos
Fibrilação Atrial , Ácidos Graxos Ômega-3 , Ácido alfa-Linolênico , Humanos , Masculino , Feminino , Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/epidemiologia , Pessoa de Meia-Idade , Ácido alfa-Linolênico/administração & dosagem , Dinamarca/epidemiologia , Ácidos Graxos Ômega-3/administração & dosagem , Fatores de Risco , Modelos de Riscos Proporcionais , Alimentos Marinhos , Dieta , Estudos Prospectivos , Seguimentos , Inquéritos e Questionários , Estudos de Coortes , Incidência
2.
Europace ; 26(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39345160

RESUMO

AIMS: The decisions about placing an ICD in a child are more difficult than in an adult due to longer expected lifespan and the complication risk. Young patients gain the most years from ICDs, despite higher risk of device-related complications. The secondary prevention ICD indication is clear, and device is implanted regardless of potential complications. For primary prevention, risk of sudden cardiac death and complications need to be evaluated. We aimed to compare outcomes for primary and secondary prevention ICDs. METHODS AND RESULTS: Retrospective nationwide cohort study including paediatric patients identified from the Danish ICD registry with ICD implanted at an age ≤ 15 from 1982-21. Demographics, complications (composite of device-related infections or lead-failure requiring re-operation, mortality because of arrhythmia, or unknown cause), and mortality were retrieved from medical charts. Endpoint was appropriate therapy (shock or anti-tachycardia pacing for ventricular tachycardia or fibrillation). Of 72 receiving an ICD, the majority had channelopathies (n = 34) or structural heart diseases (n = 28). ICDs were implanted in 23 patients for primary prevention and 49 for secondary prevention, at median ages of 13.8 and 11.6 years (P-value 0.01), respectively. Median follow-up was 9.0 (interquartile ranges: 4.7-13.5) years. The 10-year cumulative incidence of first appropriate therapy was 70%, with complication and inappropriate therapy rates at 41% and 15%, respectively. No difference was observed between prevention groups for all outcomes. Six patients died during follow-up. CONCLUSION: In children, two-thirds are secondary prevention ICDs. Children have higher appropriate therapy and complication rates than adults, while the inappropriate therapy rate was low.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Prevenção Primária , Sistema de Registros , Prevenção Secundária , Humanos , Masculino , Criança , Estudos Retrospectivos , Prevenção Secundária/métodos , Adolescente , Feminino , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Dinamarca/epidemiologia , Resultado do Tratamento , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Fatores de Risco , Pré-Escolar , Taquicardia Ventricular/terapia , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Fatores Etários , Arritmias Cardíacas/terapia , Arritmias Cardíacas/mortalidade , Fibrilação Ventricular/prevenção & controle , Fibrilação Ventricular/terapia , Fibrilação Ventricular/mortalidade , Medição de Risco
3.
Artigo em Inglês | MEDLINE | ID: mdl-39078373

RESUMO

INTRODUCTION AND AIM: Radiotherapy in cancer patients with a pacemaker or an implantable cardioverter defibrillator might damage the device and possibly result in malfunction of the device. We aimed to examine device malfunction and change in lead parameters in this group. METHODS: The medical records of pacemaker/implantable cardioverter defibrillator patients who underwent radiotherapy at Aalborg University Hospital between July 1, 2016, and June 30, 2021, were reviewed. Treatment was planned according to risk of device malfunction, assessed using local guidelines. Bootstrap linear regression was used to identify possible differences in lead parameters depending on beam energy and anatomical location. RESULTS: One hundred nine patients with a pacemaker/implantable cardioverter defibrillator who received a total of 122 radiotherapy courses in the study period were identified. No device malfunctions or significant changes in lead parameters during radiotherapy were observed. Only the left ventricle lead threshold and impedance were found to be significantly different when compared by beam energy; however, these changes were relatively small and unlikely to be of clinical relevance. CONCLUSION: No device malfunction or clinically relevant changes in lead parameters were identified in this study, suggesting that radiotherapy of pacemaker/implantable cardioverter defibrillator patients can be regarded as safe when following relevant safety precautions.

4.
Scand J Public Health ; : 14034948231205822, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38179955

RESUMO

BACKGROUND: Atrial fibrillation and flutter (AF) is the most common sustained arrhythmia with an increasing prevalence in Western countries. However, little is known about AF among immigrants compared to non-immigrants. AIM: To examine the incidence of hospital-diagnosed AF according to country of origin. METHOD: Immigrants were defined as individuals born outside Denmark by parents born outside Denmark. AF was defined as first-time diagnosis of AF. All individuals were followed from the age of 45 years from 1998 to 2017. The analyses were adjusted for sex, age, comorbidity, contact with the general practitioner and socioeconomic variables. Adjustment was conducted using standardised morbidity ratio weights, standardised to the Danish population in a marginal structural model. RESULTS: The study population consisted of 3,489,730 Danish individuals free of AF and 108,914 immigrants free of AF who had emigrated from the 10 most represented countries. A total of 323,005 individuals of Danish origin had an incident hospital diagnosis of AF, among the immigrants 7,300 developed AF. Adjusted hazard rate ratios (HRRs) of AF for immigrants from Iran (0.48 [95%CI:0.35;0.64]), Turkey (0.74 [95%CI:0.67;0.82]) and Bosnia-Herzegovina (0.42 [95%CI:0.22;0.79]) were low compared with Danish individuals. Immigrants from Sweden, Germany and Norway had an adjusted HRR of 1.13 [95%CI:1.03;1.23], 1.12 [95%CI:1.05;1.18] and 1.11 [95%CI:1.03;1.21], respectively (Danish individuals as reference). CONCLUSIONS: Substantial variation in the incidence of hospital-diagnosed AF according to country of origin was observed. The results may reflect true biological differences but could also reflect barriers to AF diagnosis for immigrants. Further efforts are warranted to determine the underlying mechanisms.

5.
Eur Heart J ; 44(40): 4246-4255, 2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37638973

RESUMO

BACKGROUND AND AIMS: High percentages of atrial pacing have been associated with an increased risk of atrial fibrillation. This study is aimed at evaluating whether atrial pacing minimization in patients with sinus node dysfunction reduces the incidence of atrial fibrillation. METHODS: In a nationwide, randomized controlled trial, 540 patients with sinus node dysfunction and an indication for first pacemaker implantation were assigned to pacing programmed to a base rate of 60 bpm and rate-adaptive pacing (DDDR-60) or pacing programmed to a base rate of 40 bpm without rate-adaptive pacing (DDD-40). Patients were followed on remote monitoring for 2 years. The primary endpoint was time to first episode of atrial fibrillation longer than 6 min. Secondary endpoints included longer episodes of atrial fibrillation, and the safety endpoint comprised a composite of syncope or presyncope. RESULTS: The median percentage of atrial pacing was 1% in patients assigned to DDD-40 and 49% in patients assigned to DDDR-60. The primary endpoint occurred in 124 patients (46%) in each treatment group (hazard ratio [HR] 0.97, 95% confidence interval [CI] 0.76-1.25, P = .83). There were no between-group differences in atrial fibrillation exceeding 6 or 24 h, persistent atrial fibrillation, or cardioversions for atrial fibrillation. The incidence of syncope or presyncope was higher in patients assigned to DDD-40 (HR 1.71, 95% CI 1.13-2.59, P = .01). CONCLUSIONS: Atrial pacing minimization in patients with sinus node dysfunction does not reduce the incidence of atrial fibrillation. Programming a base rate of 40 bpm without rate-adaptive pacing is associated with an increased risk of syncope or presyncope.

6.
Am Heart J ; 263: 112-122, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37220821

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) improves symptoms, health-related quality of life and long-term survival in patients with systolic heart failure (HF) and shortens QRS duration. However, up to one third of patients attain no measurable clinical benefit from CRT. An important determinant of clinical response is optimal choice in left ventricular (LV) pacing site. Observational data have shown that achieving an LV lead position at a site of late electrical activation is associated with better clinical and echocardiographic outcomes compared to standard placement, but mapping-guided LV lead placement towards the site of latest electrical activation has never been investigated in a randomized controlled trial (RCT). The purpose of this study was to evaluate the effect of targeted positioning of the LV lead towards the latest electrically activated area. We hypothesize that this strategy is superior to standard LV lead placement. METHODS: The DANISH-CRT trial is a national, double-blinded RCT (ClinicalTrials.gov NCT03280862). A total of 1,000 patients referred for a de novo CRT implantation or an upgrade to CRT from right ventricular pacing will be randomized 1:1 to receive conventional LV lead positioning preferably in a nonapical posterolateral branch of the coronary sinus (CS) (control group) or targeted positioning of the LV lead to the CS branch with the latest local electrical LV activation (intervention group). In the intervention group, late activation will be determined using electrical mapping of the CS. The primary endpoint is a composite of death and nonplanned HF hospitalization. Patients are followed for a minimum of 2 years and until 264 primary endpoints occurred. Analyses will be conducted according to the intention-to-treat principle. Enrollment for this trial began in March 2018, and per April 2023, a total of 823 patients have been included. Enrollment is expected to be complete by mid-2024. CONCLUSIONS: The DANISH-CRT trial will clarify whether mapping-guided positioning of the LV lead according to the latest local electrical activation in the CS is beneficial for patients in terms of reducing the composite endpoint of death or nonplanned hospitalization for heart failure. Results from this trial are expected to impact future guidelines on CRT. GOV IDENTIFIER: NCT03280862.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Incidência , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem , Hospitalização
7.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38055845

RESUMO

AIMS: Modern clinical management of patients with an implantable cardioverter defibrillator (ICD) largely consists of remote device monitoring, although a subset is at risk of mental health issues post-implantation. We compared a 12-month web-based intervention consisting of goal setting, monitoring of patients' mental health-with a psychological intervention if needed-psychoeducational support from a nurse, and an online patient forum, with usual care on participants' device acceptance 12 months after implantation. METHODS AND RESULTS: This national, multi-site, two-arm, non-blinded, randomized, controlled, superiority trial enrolled 478 first-time ICD recipients from all 6 implantation centres in Denmark. The primary endpoint was patient device acceptance measured by the Florida Patient Acceptance Survey (FPAS; general score range = 0-100, with higher scores indicating higher device acceptance) 12 months after implantation. Secondary endpoints included symptoms of depression and anxiety. The primary endpoint of device acceptance was not different between groups at 12 months [B = -2.67, 95% confidence interval (CI) (-5.62, 0.29), P = 0.08]. Furthermore, the secondary endpoint analyses showed no significant treatment effect on either depressive [B = -0.49, 95% CI (-1.19; 0.21), P = 0.17] or anxiety symptoms [B = -0.39, 95% CI (-0.96; 0.18), P = 0.18]. CONCLUSION: The web-based intervention as supplement to usual care did not improve patient device acceptance nor symptoms of anxiety and depression compared with usual care. This specific web-based intervention thus cannot be recommended as a standardized intervention in ICD patients.


Assuntos
Desfibriladores Implantáveis , Qualidade de Vida , Humanos , Ansiedade/prevenção & controle , Ansiedade/psicologia , Atenção à Saúde , Internet , Qualidade de Vida/psicologia , Inquéritos e Questionários
8.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37129985

RESUMO

AIMS: Reduced psychological health is associated with adverse patient outcomes and higher mortality. We aimed to examine if a Brugada syndrome (BrS) diagnosis and symptomatic disease presentation were associated with an increased risk of new-onset depression or anxiety and all-cause mortality. METHODS AND RESULTS: All Danish patients diagnosed with BrS (2006-2018) with no history of psychiatric disease and available for ≥6 months follow-up were identified using nationwide registries and followed for up to 5 years after diagnosis. The development of clinical depression or anxiety was evaluated using the prescription of medication and diagnosis codes. Factors associated with developing new-onset depression or anxiety were determined using a multivariate Cox proportional hazards regression model. Disease manifestation was categorized as symptomatic (aborted cardiac arrest, ventricular tachycardia, or syncope) or asymptomatic/unspecified at diagnosis. A total of 223 patients with BrS and no history of psychiatric disease were identified (72.6% male, median age at diagnosis 46 years, 45.3% symptomatic). Of these, 15.7% (35/223) developed new-onset depression or anxiety after BrS diagnosis (median follow-up 5.0 years). A greater proportion of symptomatic patients developed new-onset depression or anxiety compared with asymptomatic patients [21/101 (20.8%) and 14/122 (11.5%), respectively, P = 0.08]. Symptomatic disease presentation (HR 3.43, 1.46-8.05) and older age (lower vs. upper tertile: HR 4.41, 1.42-13.63) were significantly associated with new-onset depression or anxiety. All-cause mortality in this group of patients treated according to guidelines was low (n = 4, 1.8%); however, 3/4 developed depression or anxiety before death. CONCLUSION: Approximately, one-sixth of patients with BrS developed new-onset depression or anxiety following a diagnosis of BrS. Symptomatic BrS disease manifestation was significantly associated with new-onset depression or anxiety.


Assuntos
Síndrome de Brugada , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/complicações , Depressão/diagnóstico , Depressão/epidemiologia , Morte Súbita Cardíaca/etiologia , Eletrocardiografia/métodos , Medição de Risco/métodos , Ansiedade/diagnóstico , Ansiedade/epidemiologia , Dinamarca/epidemiologia
9.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37335977

RESUMO

AIMS: To date, potential differences in outcomes for immigrants and non-immigrants with a cardiac resynchronization therapy (CRT), in a European setting, remain underutilized and unknown. Hence, we examined the efficacy of CRT measured by heart failure (HF)-related hospitalizations and all-cause mortality among immigrants and non-immigrants. METHODS AND RESULTS: All immigrants and non-immigrants who underwent first-time CRT implantation in Denmark (2000-2017) were identified from nationwide registries and followed for up to 5 years. Differences in HF related hospitalizations and all-cause mortality were evaluated by Cox regression analyses. From 2000 to 2017, 369 of 10 741 (3.4%) immigrants compared with 7855 of 223 509 (3.5%) non-immigrants with a HF diagnosis underwent CRT implantation. The origins of the immigrants were Europe (61.2%), Middle East (20.1%), Asia-Pacific (11.9%), Africa (3.5%), and America (3.3%). We found similar high uptake of HF guideline-directed pharmacotherapy before and after CRT and a consistent reduction in HF-related hospitalizations the year before vs. the year after CRT (61% vs. 39% for immigrants and 57% vs. 35% for non-immigrants). No overall difference in 5-year mortality among immigrants and non-immigrants was seen after CRT [24.1% and 25.8%, respectively, P-value = 0.50, hazard ratio (HR) = 1.2, 95% confidence interval (CI): 0.8-1.7]. However, immigrants of Middle Eastern origin had a higher mortality rate (HR = 2.2, 95% CI: 1.2-4.1) compared with non-immigrants. Cardiovascular causes were responsible for the majority of deaths irrespective of immigration status (56.7% and 63.9%, respectively). CONCLUSION: No overall differences in efficacy of CRT in improving outcomes between immigrants and non-immigrants were identified. Although numbers were low, a higher mortality rate among immigrants of Middle Eastern origin was identified compared with non-immigrants.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Modelos de Riscos Proporcionais , Desfibriladores Implantáveis/efeitos adversos
10.
Pacing Clin Electrophysiol ; 46(2): 108-113, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36333921

RESUMO

BACKGROUND: Atrial fibrillation and flutter are often treated with external electrical cardioversion (ECV) in patients with potentially electrically sensitive cardiovascular implantable electronic devices (CIED). Long-term follow-up data on contemporary CIED undergoing ECV is sparse. The aim is to investigate shock-related complications and impact on CIEDs. METHODS: All ECV procedures from 2010 to 2020 in patients with CIED performed at a tertiary university hospital were identified in the Danish National Patient Registry. Changes in device measurements after ECV were retrospectively studied and procedure-related complications were identified by review of medical records. RESULTS: We analyzed 763 ECV procedures in 372 patients, median device implant time 1.9 years. The mean age of patients was 69.9 ± 9.9 years of which 73.4% were men. We identified two cases of device programming changes and four cases of premature battery depletion (≤3 years after device implant). Minor changes in device measurements were found for impedances, sensing, and pacing thresholds. No patients died due to ECV-related device dysfunctions within the first 12 months after cardioversions. CONCLUSION: External cardioversion in patients with contemporary pacemakers and implantable cardioverter-defibrillators seems safe in the majority of patients. Clinically important changes in device function following cardioversion were rarely observed but may be critical for device function. In an observational study, causality between cardioversion and device dysfunction cannot be established. For patient safety, we suggest that routine device interrogation after cardioversion still should be part of standard care.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Marca-Passo Artificial , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/terapia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Estudos Retrospectivos
11.
Cardiovasc Ultrasound ; 21(1): 8, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37127676

RESUMO

AIMS: The pathophysiological effects of chronic right ventricular pacing and the role of right ventricular lead position are not well understood. Therefore, we investigated the association between left ventricular contractile dyssynchrony and pacing-induced cardiomyopathy (PICM) in patients with chronic right ventricular pacing. Furthermore, we assessed the association between right ventricular lead location and left ventricular contractile dyssynchrony. METHODS: This was a retrospective study using data from 153 pacemaker patients with normal (≥ 50%) pre-implant left ventricular ejection fraction (LVEF). Baseline and follow-up echocardiograms were analyzed, and PICM was defined as LVEF < 50% with ≥ 10% decrease in LVEF after pacemaker implantation. Relative index of contractile asymmetry (rICA), a novel strain rate-based method, was calculated to quantify left ventricular contractile dyssynchrony between opposing walls in the three apical views. Right ventricular lead position was categorized into anterior septum, posterior septum, free wall, and apex based on contrast-enhanced cardiac computed tomography. RESULTS: Forty-seven (31%) developed PICM. Overall contractile dyssynchrony, measured by mean rICA, was higher in the PICM group compared with the non-PICM group (1.19 ± 0.21 vs. 1.03 ± 0.19, p < 0.001). Left ventricular anterior-inferior dyssynchrony, assessed in the apical two-chamber view, was independently associated with PICM (p < 0.001). Thirty-seven (24%) leads were implanted anterior septal, 11 (7.2%) posterior septal, 74 (48.4%) apical, and 31 (20.3%) free wall. Left ventricular anterior-inferior dyssynchrony was significantly different between the four pacing lead locations (p < 0.01) with the highest rICA observed in the posterior septal group (1.30 ± 0.37). CONCLUSIONS: PICM is significantly associated increased contractile dyssynchrony assessed by rICA. This study suggests that especially left ventricular dyssynchrony in the anterior-inferior direction is associated with PICM, and pacing the right ventricular posterior septum resulted in the highest degree of anterior-inferior dyssynchrony. Quantification of left ventricular dyssynchrony by rICA provides important insights to the potential pathophysiology of PICM and the impact of right ventricular lead position.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Disfunção Ventricular Esquerda , Humanos , Função Ventricular Esquerda/fisiologia , Volume Sistólico , Estudos Retrospectivos
12.
Eur J Clin Invest ; 52(1): e13649, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34233016

RESUMO

BACKGROUND: The aim of the present study was to examine the relation between adipose tissue content of eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) and the risk of incident atrial fibrillation (AF). METHODS: In this case-cohort study based on data from the Danish Diet, Cancer and Health cohort, a total of 5255 incident cases of AF was identified during 16.9 years of follow-up. Adipose tissue biopsies collected at baseline from all cases and from a randomly drawn subcohort of 3440 participants were determined by gas chromatography. Data were analysed using weighted Cox regression. RESULTS: Data were available for 4741 incident cases of AF (2920 men and 1821 women). Participants in the highest vs. the lowest quintile of EPA experienced a 45% lower risk of AF (men HR 0.55 (95% CI 0.41-0.69); women HR 0.55 (0.41-0.72)). For DHA, no clear association was found in men, whereas in women, participants in the highest quintile of DHA in adipose tissue had a 30% lower risk of incident AF (HR 0.70 (0.54-0.91)) compared to participants in the lowest quintile. CONCLUSIONS: A monotonous inverse association was found for the content of EPA in adipose tissue and risk of AF in both men and women. The content of DHA was inversely associated with the risk of AF in women, whereas no clear association was found for men.


Assuntos
Tecido Adiposo/química , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Ácidos Docosa-Hexaenoicos/análise , Ácidos Docosa-Hexaenoicos/fisiologia , Ácido Eicosapentaenoico/análise , Ácido Eicosapentaenoico/fisiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco
13.
Br J Clin Pharmacol ; 88(8): 3847-3855, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35355307

RESUMO

AIMS: Schizophrenia is associated with poor anticoagulation control and clinical prognosis in patients with atrial fibrillation (AF). Little is known about initiation of oral anticoagulation therapy (OAC) in this patient population. METHODS: In the nationwide Danish health registries, we identified all patients with incident AF and schizophrenia with indication for OAC treatment. Patients with schizophrenia (n = 673) were matched 1:5 on sex, age, stroke risk score, and calendar-period to incident AF patients without schizophrenia. We calculated absolute risk and risk difference (RD) of OAC initiation, adjusting for stroke and bleeding risk factors. Analyses were stratified by calendar period (2000-2011 and 2012-2018) to account for changes after the introduction of non-vitamin K OACs (NOAC). RESULTS: Among patients with schizophrenia (mean age 69.5 years, 50.3% females), 33.7% initiated OAC within the first year after AF diagnosis, compared with 54.4% of patients without schizophrenia, corresponding to an adjusted RD of -20.7 (95% confidence interval [CI]: -24.7 to -16.7). OAC initiation increased over time regardless of schizophrenia status. During 2000-2011, 18.3% of patients with schizophrenia and 42.9% without schizophrenia initiated OAC (adjusted RD -23.6%, 95% CI -28.8 to -18.6). During 2012-2018, this was 48.5% and 65.7%, respectively (adjusted RD -14.4%, 95% CI -20.4 to -8.4). CONCLUSION: Initiation of OAC was substantially lower among patients with AF and schizophrenia compared with matched AF peers. These findings accentuate the importance of close attention to disparities in initiation of OAC treatment, and potential missed opportunities for prevention of disabling strokes in AF patients with schizophrenia.


Assuntos
Fibrilação Atrial , Esquizofrenia , Acidente Vascular Cerebral , Administração Oral , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Fatores de Risco , Esquizofrenia/complicações , Esquizofrenia/tratamento farmacológico , Esquizofrenia/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
14.
Scand Cardiovasc J ; 56(1): 378-386, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36271783

RESUMO

Objectives. New-onset postoperative atrial fibrillation (POAF) is a common complication after cardiac surgery. The arrhythmia often entails a longer hospital stay, greater risk of other complications, and higher mortality both short- and long-term. An investigation of the use of early atrial electrograms in predicting POAF in cardiac surgery was performed. Design. In this prospective observational study, a total of 99 consecutive adult patients undergoing coronary artery bypass grafting, valve surgery or both were included. On the first postoperative morning, standard 12-lead electrograms (ECG), unipolar atrial electrograms (aEG), and vital values were recorded. The outcome was new-onset POAF within one month postoperatively. Results. Three multivariable prediction models for POAF were formed using measurements derived from the ECG, aEG, and patient characteristics. Age, body mass index, and two unipolar electrogram measurements quantifying local activation time and fractionation were strongly associated with the outcome POAF. The performance of the POAF prediction models was assessed through receiver operating curve characteristics with cross-validation, and discrimination using the leave-one-out-method to internally validate the models. The cross-validated area under the receiver operating characteristic curve (AUC) was improved in a prediction model using atrial-derived electrogram variables (AUC 0.796, 95% CI 0.698-0.894), compared with previous ECG and clinical models (AUC 0.716, 95% CI 0.606-0.826 and AUC 0.718, 95% CI 0.613-0.822, respectively). Conclusions. This study found that easily obtainable measurements from atrial electrograms may be helpful in identifying patients at risk of POAF in cardiac surgery.


Assuntos
Fibrilação Atrial , Adulto , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fatores de Risco , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Ponte de Artéria Coronária/efeitos adversos
15.
Scand Cardiovasc J ; 56(1): 285-291, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35866506

RESUMO

Aim.To validate the National Danish Ablation Database (NDAD) by investigating to what extent data in NDAD correspond to medical records.Type of study. Non-blinded, registry-based, retrospective, validation study. Material and methods. A sample of patients who underwent ablation for atrial fibrillation in Denmark between 1 January 2016 and 31 December 2016 were included. By utilizing medical records as gold standard, positive predictive (PPV) and negative predictive values (NPV) for NDAD were assessed and presented as five main categories: arrhythmia characteristics, demographics, cardiac history, complications, and medication. PPV's and NPV's exceeding 90% were considered as high agreement. Results. 597 patients (71.0% males) were included in the study. Median age was 63.1 (IQR: 54.9-68.4) years. The median PPV and NPV estimates across all variables were respectively 90.4% (95% CI: 68%-95.2%) (PPV) and 99.4% (95% CI: 98.4%-99.8%) (NPV) at baseline, and 91.7% (95% CI: 67.4%-95.4%) (PPV) and 99.3% (98.2%-99.3%) (NPV) at follow-up. Conclusion. The data registered in NDAD agrees to a great extent with the patients' medical records, suggesting NDAD is a database with high validity. As a result of low complication rate, the PPV- and NPV-estimates among complication variables were prone to somewhat greater uncertainty compared to the rest.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Bases de Dados Factuais , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Dinamarca/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos
16.
J Cardiothorac Vasc Anesth ; 36(10): 3730-3737, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35581051

RESUMO

OBJECTIVES: New-onset postoperative atrial fibrillation (POAF) is a common complication after cardiac surgery. A targeted approach is necessary for prophylactic handling of the complication. The authors tested the performance of the C2HEST score to predict POAF in patients undergoing cardiac surgery. DESIGN: Register-based cohort study. SETTING: Three cardiothoracic centers. PARTICIPANTS: All adult patients undergoing cardiac surgery in Western Denmark between January 1, 2010, and December 31, 2018, were included. Data on patient comorbidities before surgery were obtained from the Western Denmark Heart Registry, the Danish National Patient Registry, and the Danish National Prescription Registry. INTERVENTIONS: The C2HEST score (C2: Coronary Artery Disease/Chronic Obstructive Pulmonary Disease [1 point each]; H: Hypertension; E: Elderly [Age ≥75, 2 points]; S: Systolic Heart Failure [2 points]; T: Thyroid disease [hyperthyroidism]) was calculated for each patient. The primary outcome was POAF within the primary hospital stay. The C2HEST score's discriminative ability was evaluated and compared with an age-stratified version (mC2HEST) as well as 2 validated clinical risk models (CHADS2 and CHA2DS2-VASc). MEASUREMENTS AND MAIN RESULTS: Among the 14,279 patients included, 4,298 (30.1%) developed POAF. The C2HEST score's performance was not significantly better than the CHADS2 and CHA2DS2-VASc scores (area under the curve [AUC] 0.553 [95% confidence interval {CI} 0.543; 0.563] v 0.543 [95% CI 0.535; 0.552] and 0.565 [95% CI 0.555; 0.574], respectively). The age-modified (mC2HEST) score showed only modest improvement in the risk model, with an AUC of 0.580 (95% CI 0.570; 0.590). CONCLUSION: The discriminative ability of the C2HEST score, measured by the AUC, was limited in this population, and was not proven to be superior to the CHADS2, CHA2DS2-VASc, and mC2HEST scores in predicting POAF after cardiac surgery.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos de Coortes , Dinamarca/epidemiologia , Humanos , Valor Preditivo dos Testes , Prescrições , Sistema de Registros , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/complicações
17.
Eur Heart J ; 42(35): 3529-3537, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-33954626

RESUMO

AIMS: Patients are restricted from driving following implantable cardioverter defibrillator (ICD) implantation or shock. We sought to investigate how many patients are aware of, and adhere to, the driving restrictions, and what proportion experience an ICD shock or other cardiac symptoms while driving. METHODS AND RESULTS: We performed a nationwide survey of all living Danish residents 18 years or older who received a first-time ICD between 2013 and 2016 (n = 3913) and linked their responses with nationwide registers. Of 2741 respondents (47% primary prevention, 83% male, median age 67 years), 2513 (92%) held a valid driver's license at ICD implantation, 175 (7%) of whom had a license for professional driving. Many drivers were unaware of driving restrictions: primary prevention 58%; secondary prevention 36%; post-appropriate shock 28%; professional drivers 55%. Almost all (94%) resumed non-professional driving after ICD implantation, more than one-third during the restricted period; 35% resumed professional driving. During a median follow-up of 2.3 years, 5 (0.2%) reported receiving an ICD shock while driving, one of which resulted in a traffic accident. The estimated risk of harm was 0.0002% per person-year. CONCLUSION: In this nationwide study, many ICD patients were unaware of driving restrictions, and more than one third resumed driving during a driving restriction period. However, the rate of reported ICD shocks while driving was very low.


Assuntos
Condução de Veículo , Desfibriladores Implantáveis , Acidentes de Trânsito , Idoso , Morte Súbita Cardíaca , Feminino , Humanos , Masculino , Prevenção Primária , Inquéritos e Questionários
18.
Europace ; 23(10): 1577-1585, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-34322707

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) upgrades may be less likely to improve following intervention. Leadless left ventricular (LV) endocardial pacing has been used for patients with previously failed CRT or high-risk upgrades. We compared procedural and long-term outcomes in patients undergoing coronary sinus (CS) CRT upgrades with high-risk and previously failed CRT upgrades undergoing LV endocardial upgrades. METHOD AND RESULTS: Prospective consecutive CS upgrades between 2015 and 2019 were compared with those undergoing WiSE-CRT implantation. Cardiac resynchronization therapy response at 6 months was defined as improvement in clinical composite score (CCS) and a reduction in LV end-systolic volume (LVESV) ≥15%. A total of 225 patients were analysed; 121 CS and 104 endocardial upgrades. Patients receiving WiSE-CRT tended to have more comorbidities and were more likely to have previous cardiac surgery (30.9% vs. 16.5%; P = 0.012), hypertension (59.2% vs. 34.7%; P < 0.001), chronic obstructive airways disease (19.4% vs. 9.9%; P = 0.046), and chronic kidney disease (46.4% vs. 21.5%; P < 0.01) but similar LV ejection fraction (30.0 ± 8.3% vs. 29.5 ± 8.6%; P = 0.678). WiSE-CRT upgrades were successful in 97.1% with procedure-related mortality in 1.9%. Coronary sinus upgrades were successful in 97.5% of cases with a 2.5% rate of CS dissection and 5.6% lead malfunction/displacement. At 6 months, 91 WiSE-CRT upgrades and 107 CS upgrades had similar improvements in CCS (76.3% vs. 68.5%; P = 0.210) and reduction in LVESV ≥15% (54.2% vs. 56.3%; P = 0.835). CONCLUSION: Despite prior failed upgrades and high-risk patients with more comorbidities, WiSE-CRT upgrades had high rates of procedural success and similar improvements in CCS and LV remodelling with CS upgrades.


Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário , Insuficiência Cardíaca , Seio Coronário/diagnóstico por imagem , Endocárdio , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
19.
Am J Kidney Dis ; 75(2): 214-224, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31542235

RESUMO

RATIONALE & OBJECTIVE: Patients with kidney failure treated with maintenance dialysis experience a high rate of mortality, in part due to sudden cardiac death caused by arrhythmias. The prevalence of arrhythmias, including the subset that are clinically significant, is not well known. This study sought to estimate the prevalence of arrhythmias, characterize the pattern of arrhythmic events in relation to dialysis treatments, and identify associated clinical characteristics. STUDY DESIGN: Cross-sectional study. SETTING & PARTICIPANTS: 152 patients with kidney failure treated with maintenance dialysis in Denmark. EXPOSURES: Dialysis treatment; clinical characteristics; cardiac output and preload defined using echocardiography. OUTCOMES: Prevalence and pattern of arrhythmias on 48-hour Holter monitoring; odds ratios for arrhythmias. ANALYTICAL APPROACH: Descriptive analysis of the prevalence of arrhythmias. Pattern of arrhythmias described using a repeated-measures negative binomial regression model. Associations between clinical characteristics and echocardiographic findings with arrhythmias were assessed using logistic regression. RESULTS: Among the 152 patients studied, 83.6% were treated with in-center dialysis; 10.5%, with home hemodialysis; and 5.9%, with peritoneal dialysis. Premature atrial and ventricular complexes were seen in nearly all patients and 41% had paroxysmal supraventricular tachycardia. Clinically significant arrhythmias included persistent atrial fibrillation observed among 8.6% of patients, paroxysmal atrial fibrillation among 3.9%, nonsustained ventricular tachycardia among 19.7%, bradycardia among 4.6%, advanced second-degree atrioventricular block among 1.3%, and third-degree atrioventricular block among 2.6%. Premature ventricular complexes were more common on dialysis days, while tachyarrhythmias were more often observed during dialysis and in the immediate postdialytic period. Older age (OR per 10 years older, 1.53; 95% CI, 1.15-2.03; P=0.003), elevated preload (OR, 4.02; 95% CI, 1.05-15.35; P=0.04), and lower cardiac output (OR per 1L/min greater, 0.66; 95% CI, 0.44-1.00; P=0.05) were independently associated with clinically significant arrhythmias. LIMITATIONS: Arrhythmia monitoring limited to 48 hours; small sample size; heterogeneous nature of the population, risk for residual confounding. CONCLUSIONS: Arrhythmias, including clinically significant abnormal rhythms, were common. Tachyarrhythmias were more frequent during dialysis and the immediate postdialytic period. The relevance of these findings to clinical outcomes requires additional study.


Assuntos
Arritmias Cardíacas/etiologia , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Estudos Transversais , Dinamarca/epidemiologia , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Humanos , Incidência , Falência Renal Crônica/complicações , Falência Renal Crônica/mortalidade , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida/tendências
20.
Europace ; 22(12): 1830-1840, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33106878

RESUMO

AIMS: To investigate (i) the prevalence of anxiety and depression and (ii) the association between indication for implantable cardioverter-defibrillator (ICD) implantation and sex in relation to anxiety and depression up to 24 months' follow-up. METHODS AND RESULTS: Patients with a first-time ICD, participating in the national, multi-centre, prospective DEFIB-WOMEN study (n = 1496; 18% women) completed the Hospital Anxiety and Depression Scale at baseline, 3, 6, 12, and 24 months. Data were analysed using linear mixed modelling for longitudinal data. Patients with a secondary prophylactic indication (SPI) had higher mean anxiety scores than patients with a primary prophylactic indication (PPI) at baseline, 3, and 12 months and higher mean depression scores at all-time points, except at 24 months. Women had higher mean anxiety scores as compared to men at all-time points; however, only higher mean depression scores at baseline. Overall, women with SPI had higher anxiety and depression symptom scores than men with SPI. Symptoms decreased over time in both women and men. From baseline to follow-up, the prevalence of anxiety (score ≥8) was highest in patients with SPI (13.3-20.2%) as compared to patients with PPI (range 10.0-14.7%). The prevalence of depression was stable over the follow-up period in both groups (range 8.5-11.1%). CONCLUSION: Patients with a SPI reported higher anxiety and depression scores as compared to patients with PPI. Women reported higher anxiety scores than men, but only higher depression scores at baseline. Women with SPI reported the highest anxiety and depression scores overall.


Assuntos
Desfibriladores Implantáveis , Ansiedade/diagnóstico , Ansiedade/epidemiologia , Dinamarca/epidemiologia , Depressão/diagnóstico , Depressão/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Prevalência , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA