Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38339545

RESUMO

Myocardial Infarction (MI), commonly known as heart attack, is a cardiac condition characterized by damage to a portion of the heart, specifically the myocardium, due to the disruption of blood flow. Given its recurring and often asymptomatic nature, there is the need for continuous monitoring using wearable devices. This paper proposes a single-microcontroller-based system designed for the automatic detection of MI based on the Edge Computing paradigm. Two solutions for MI detection are evaluated, based on Machine Learning (ML) and Deep Learning (DL) techniques. The developed algorithms are based on two different approaches currently available in the literature, and they are optimized for deployment on low-resource hardware. A feasibility assessment of their implementation on a single 32-bit microcontroller with an ARM Cortex-M4 core was examined, and a comparison in terms of accuracy, inference time, and memory usage was detailed. For ML techniques, significant data processing for feature extraction, coupled with a simpler Neural Network (NN) is involved. On the other hand, the second method, based on DL, employs a Spectrogram Analysis for feature extraction and a Convolutional Neural Network (CNN) with a longer inference time and higher memory utilization. Both methods employ the same low power hardware reaching an accuracy of 89.40% and 94.76%, respectively. The final prototype is an energy-efficient system capable of real-time detection of MI without the need to connect to remote servers or the cloud. All processing is performed at the edge, enabling NN inference on the same microcontroller.


Assuntos
Cardiopatias , Infarto do Miocárdio , Humanos , Infarto do Miocárdio/diagnóstico , Coração , Miocárdio , Algoritmos
2.
Breast J ; 2023: 6688466, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37205012

RESUMO

Purpose: In modern breast cancer treatment, a growing role has been observed for breast reconstruction together with an increase in clinical indications for postmastectomy radiotherapy (PMRT). Choosing the optimum type of reconstructive technique is a clinical challenge. We therefore conducted a national multicenter study to analyze the impact of PMRT on breast reconstruction. Methods: We conducted a retrospective case-control multicenter study on women undergoing breast reconstruction. Data were collected from 18 Italian Breast Centres and stored in a cumulative database which included the following: autologous reconstruction, direct-to-implant (DTI), and tissue expander/immediate (TE/I). For all patients, we described complications and surgical endpoints to complications such as reconstruction failure, explant, change in type of reconstruction, and reintervention. Results: From 2001 to April 2020, 3116 patients were evaluated. The risk for any complication was significantly increased in patients receiving PMRT (aOR, 1.73; 95% CI, 1.33-2.24; p < 0.001). PMRT was associated with a significant increase in the risk of capsular contracture in the DTI and TE/I groups (aOR, 2.24; 95% CI, 1.57-3.20; p < 0.001). Comparing type of procedures, the risk of failure (aOR, 1.82; 95% CI, 1.06-3.12, p=0.030), explant (aOR, 3.34; 95% CI, 3.85-7.83, p < 0.001), and severe complications (aOR, 2.54; 95% CI, 1.88-3.43, p < 0.001) were significantly higher in the group undergoing DTI reconstruction as compared to TE/I reconstruction. Conclusion: Our study confirms that autologous reconstruction is the procedure least impacted by PMRT, while DTI appears to be the most impacted by PMRT, when compared with TE/I which shows a lower rate of explant and reconstruction failure. The trial is registered with NCT04783818, and the date of registration is 1 March, 2021, retrospectively registered.


Assuntos
Neoplasias da Mama , Mamoplastia , Feminino , Humanos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/etiologia , Radioterapia Adjuvante/efeitos adversos , Radioterapia Adjuvante/métodos , Mastectomia/métodos , Estudos Retrospectivos , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Mamoplastia/efeitos adversos , Mamoplastia/métodos
3.
BMC Surg ; 23(1): 268, 2023 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-37667203

RESUMO

BACKGROUND: Ulnar nerve entrapment at the elbow is the second most common cause of nerve entrapment in the upper limb. Surgical techniques mainly include simple decompression, decompression with anterior transposition and medial epicondylectomy. METHODS: We performed decompression with anterior transposition and protected ulnar nerve by adipofascial flap (a random flap with radial based vascularization, harvested through the avascular plane of Scarpa's fascia. We analyzed patients who underwent ulnar nerve ante-position from 2015 to 2022 according to inclusion and exclusion criteria for a total of 57 patients. All patients included were graded on the McGowan's classification Messina criteria and the British Medical Research Council modified by Mackinnon and Dellon. RESULTS: The average McGowan's score was 2.4 (± 0.6), Messina's criteria 91.2% indicated a satisfactory or excellent result, sensibility at 6 months was 98.5% S3 or more. A preferential technique has not yet been defined. CONCLUSIONS: The adipofascial flap offers numerous advantages in providing a pliable, vascular fat envelope, which mimics the natural fatty environment of peripheral nerves and creates favorable micro-environmental conditions to contribute to neural regeneration via axon outgrowth.


Assuntos
Articulação do Cotovelo , Cotovelo , Humanos , Nervo Ulnar/cirurgia , Extremidade Superior , Antebraço
4.
Sensors (Basel) ; 23(5)2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36904622

RESUMO

The employability of photonics technology in the modern era's highly demanding and sophisticated domain of aerospace and submarines has been an appealing challenge for the scientific communities. In this paper, we review our main results achieved so far on the use of optical fiber sensors for safety and security in innovative aerospace and submarine applications. In particular, recent results of in-field applications of optical fiber sensors in aircraft monitoring, from a weight and balance analysis to vehicle Structural Health Monitoring (SHM) and Landing Gear (LG) monitoring, are presented and discussed. Moreover, underwater fiber-optic hydrophones are presented from the design to marine application.

5.
Sensors (Basel) ; 23(5)2023 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-36904762

RESUMO

Our group, involving researchers from different universities in Campania, Italy, has been working for the last twenty years in the field of photonic sensors for safety and security in healthcare, industrial and environment applications. This is the first in a series of three companion papers. In this paper, we introduce the main concepts of the technologies employed for the realization of our photonic sensors. Then, we review our main results concerning the innovative applications for infrastructural and transportation monitoring.

6.
Sensors (Basel) ; 23(6)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36991894

RESUMO

In order to complete this set of three companion papers, in this last, we focus our attention on environmental monitoring by taking advantage of photonic technologies. After reporting on some configurations useful for high precision agriculture, we explore the problems connected with soil water content measurement and landslide early warning. Then, we concentrate on a new generation of seismic sensors useful in both terrestrial and under water contests. Finally, we discuss a number of optical fiber sensors for use in radiation environments.

7.
Aesthetic Plast Surg ; 47(Suppl 1): 28-31, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35428917

RESUMO

Rectus muscles widened by pregnancy are handled in dramatically different ways in standard abdominoplasty and mesh abdominoplasty. Patients with significant abdominal wall laxity and/or umbilical hernia repair are treated with the use of retrorectus mesh placement. In these conditions the risk of damaging the blood supply to the umbilicus might be greater. Despite the fact that it is of no functional significance in adults, the umbilicus is a key esthetic landmark of the anterior abdominal wall. For both patients and surgeons alike, its absence, distortion, or misplacement after surgery can be distressing and can be a source of frequent patient complaint. Umbilical stalk necrosis represents an underreported yet important complication for patients following mesh abdominoplasty. We advance some recommendations for patients undergoing abdominoplasty with mesh repair of rectus diastasis and/or concomitant umbilical hernia mesh repair via the open approach. This information should help influence intraoperative decision-making to prevent the development of this undesirable complication.Level of Evidence V: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Abdominoplastia , Hérnia Umbilical , Adulto , Feminino , Gravidez , Humanos , Umbigo/cirurgia , Hérnia Umbilical/etiologia , Hérnia Umbilical/cirurgia , Telas Cirúrgicas , Abdominoplastia/efeitos adversos , Necrose/etiologia , Necrose/prevenção & controle , Necrose/cirurgia
8.
Aesthetic Plast Surg ; 2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37644192

RESUMO

BACKGROUND: Two-stages pre-pectoral breast reconstruction may confer advantages over direct to implant (DTI) and subpectoral reconstruction in selected patients who have no indication for autologous reconstruction. The primary endpoint of the study was to evaluate and compare the incidence of capsular contracture in the pre-pectoral two-stages technique versus the direct to implant technique. Complications related to the two surgical techniques and patient satisfaction were also evaluated. METHODS: A retrospective review of 45 two stages and 45 Direct-to-implant, DTI patients was completed. Acellular dermal matrix was used in all patients. An evaluation of anthropometric and clinical parameters, surgical procedures and complications was conducted. Minimum follow-up was 12 months after placement of the definitive implant. RESULTS: There was no statistically significant difference in the rate of capsular contracture in the two groups. Rippling occurred more in DTI reconstruction. In the two-stages reconstruction, lipofilling was applied more often and there was a higher incidence of seroma. Patient satisfaction extrapolated from the Breast Q questionnaire was better for patients submitted to two-stage implant-based breast reconstruction. CONCLUSION: Dual-stage pre-pectoral reconstruction with acellular dermal matrix appears to be a good reconstructive solution in patients with relative contraindications for one-stage heterologous reconstruction with definitive prosthesis and no desire for autologous reconstruction.

9.
Aesthet Surg J ; 43(10): NP787-NP796, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37378563

RESUMO

BACKGROUND: Liposuction is a safe, simple, and effective method of body contouring. Pain, ecchymosis, and edema are often local complications at the removal site, especially in the first weeks after surgery. Several studies have shown that kinesiology (kinesio) taping improves blood and lymphatic flow, removing congestions of lymphatic fluid and alleviating hemorrhage. However, there are limited data on the effect of kinesio taping in mitigating local complications at fat grafting donor sites. OBJECTIVES: The aim of this pilot study was to evaluate the impact of kinesio taping in reducing postoperative edema, pain, and ecchymosis in the liposuction area. METHODS: Over a period of 18 months (January 2021-June 2022), 52 patients underwent liposuction of both flanks with subsequent breast fat grafting. Immediately after the surgery, kinesio taping was used on the right abdomen flank in all patients. Degree of edema as well as ecchymosis and pain were quantified at 7, 14, and 21 days after surgery. RESULTS: There were statistically significant differences in the taping area for ecchymosis at 7 days after surgery, edema at 14 and 21 days after surgery, and in pain, rated on a visual analog scale, at 7, 14 and 21 days after surgery. CONCLUSIONS: Kinesio taping, as used in this study, is beneficial in the reduction of edema and pain and the resolution of ecchymosis after liposuction.


Assuntos
Equimose , Lipectomia , Humanos , Projetos Piloto , Equimose/etiologia , Equimose/prevenção & controle , Estudos Prospectivos , Lipectomia/efeitos adversos , Dor/etiologia , Edema/etiologia , Edema/prevenção & controle
10.
Medicina (Kaunas) ; 59(2)2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36837474

RESUMO

Background and Objectives: Tendon injury and tendinopathy are among the most frequent musculoskeletal diseases and represent a challenging issue for surgeons as well as a great socio-economic global burden. Despite the current treatments available, either surgical or conservative, the tendon healing process is often suboptimal and impaired. This is due to the inherent scarce ability of tendon tissue to repair and return itself to the original structure. Recently, Adipose-derived mesenchymal stem cells (ADSC) and stromal vascular fraction (SVF) have gained a central interest in the scientific community, demonstrating their effectiveness in treatments of acute and chronic tendon disorders in animals and humans. Either enzymatic or mechanical procedures to obtain ADSC and SVF have been described and used in current clinical practice. However, no unified protocols and processes have been established. Materials and Methods: This systematic review aims at providing a comprehensive update of the literature on the clinical application of ADSC enzymatically or mechanically processed to obtain SVF, alone and in association with biomaterials in the local treatment of tendinopathy and tendon injury in vivo, in animal models and humans. The study was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Results: Thirty-two articles met our inclusion criteria, with a total of 18 studies in animals, 10 studies in humans and 4 studies concerning the application of biomaterials in vivo in animals. The review of the literature suggests that ADSC/SVF therapy can represent a promising alternative in tendonregenerative medicine for the enhancement of tendon healing. Conclusions: Nevertheless, further investigations and randomized control trials are needed to improve the knowledge, standardize the procedures and extend the consensus on their use for such applications.


Assuntos
Células-Tronco Mesenquimais , Tendinopatia , Animais , Humanos , Fração Vascular Estromal , Materiais Biocompatíveis , Tendinopatia/terapia , Tendões
11.
Breast Cancer Res Treat ; 191(2): 355-363, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34755240

RESUMO

BACKGROUND: Autologous fat grafting (AFG), defined as the re-implant to the breast of fat tissue from different body areas, has been firstly applied to esthetic plastic surgery and then has moved to reconstructive surgery, mainly used for scar correction and opposite breast altering. Nevertheless, due to the potentially unsafe stem-like properties of adipocytes at the tumoral bed level, no clear evidence of the procedure's oncological safety has been clearly documented at present. PATIENTS AND METHODS: We retrospectively collected data of early breast cancer (BC) patients from 17 Italian Breast Units and assessed differences in terms of locoregional recurrence rate (LRR) and locoregional recurrence-free survival (LRFS) between patients who underwent AFG and patients who did not. Differences were analyzed in the entire cohort of invasive tumors and in different subgroups, according to prognostic biological subtypes. RESULTS: With a median follow-up time of 60 months, LRR was 5.3% (n = 71) in the matched population, 3.9% (n = 18) in the AFG group, and 6.1% (n = 53) in the non-AFG group, suggesting non-inferiority of AFG (p = 0.084). Building Kaplan-Meier curves confirmed non-inferiority of the AFG procedure for LRFS (aHR 0.73, 95% CI 0.41-1.30, p = 0.291). The same effect, in terms of LRFS, was also documented among different biological subtypes (luminal-like group, aHR 0.76, 95% CI 0.34-1.68, p = 0.493; HER2 enriched-like, aHR 0.89, 95% CI 0.19-4.22, p = 0.882; and TNBC, aHR 0.61, 95% CI 0.12-2.98, p = 0.543). CONCLUSIONS: Our study confirms in a very large, multicenter cohort of early BC patients that, aside the well-known benefits on the esthetic result, AFG do not interfere negatively with cancer prognosis.


Assuntos
Neoplasias da Mama , Mamoplastia , Tecido Adiposo , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mamoplastia/efeitos adversos , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/cirurgia , Estudos Retrospectivos
12.
Sensors (Basel) ; 22(19)2022 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-36236663

RESUMO

Pulse waves (PWs) are mechanical waves that propagate from the ventricles through the whole vascular system as brisk enlargements of the blood vessels' lumens, caused by sudden increases in local blood pressure. Photoplethysmography (PPG) is one of the most widespread techniques employed for PW sensing due to its ability to measure blood oxygen saturation. Other sensors and techniques have been proposed to record PWs, and include applanation tonometers, piezoelectric sensors, force sensors of different kinds, and accelerometers. The performances of these sensors have been analyzed individually, and their results have been found not to be in good agreement (e.g., in terms of PW morphology and the physiological parameters extracted). Such a comparison has led to a deeper comprehension of their strengths and weaknesses, and ultimately, to the consideration that a multimodal approach accomplished via sensor fusion would lead to a more robust, reliable, and potentially more informative methodology for PW monitoring. However, apart from various multichannel and multi-site systems proposed in the literature, no true multimodal sensors for PW recording have been proposed yet that acquire PW signals simultaneously from the same measurement site. In this study, a true multimodal PW sensor is presented, which was obtained by integrating a piezoelectric forcecardiography (FCG) sensor and a PPG sensor, thus enabling simultaneous mechanical-optical measurements of PWs from the same site on the body. The novel sensor performance was assessed by measuring the finger PWs of five healthy subjects at rest. The preliminary results of this study showed, for the first time, that a delay exists between the PWs recorded simultaneously by the PPG and FCG sensors. Despite such a delay, the pulse waveforms acquired by the PPG and FCG sensors, along with their first and second derivatives, had very high normalized cross-correlation indices in excess of 0.98. Six well-established morphological parameters of the PWs were compared via linear regression, correlation, and Bland-Altman analyses, which showed that some of these parameters were not in good agreement for all subjects. The preliminary results of this proof-of-concept study must be confirmed in a much larger cohort of subjects. Further investigation is also necessary to shed light on the physical origin of the observed delay between optical and mechanical PW signals. This research paves the way for the development of true multimodal, wearable, integrated sensors and for potential sensor fusion approaches to improve the performance of PW monitoring at various body sites.


Assuntos
Oximetria , Fotopletismografia , Pressão Sanguínea , Dedos , Frequência Cardíaca , Humanos , Oximetria/métodos , Fotopletismografia/métodos , Análise de Onda de Pulso/métodos
13.
Medicina (Kaunas) ; 58(6)2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-35744098

RESUMO

Background and Objectives: Wound healing is commonly associated with critical bacterial colonization or bacterial infection, which induces prolonged inflammation, resulting in delayed re-epithelialization. An appropriate wound dressing requires a humid environment, which also functions as a barrier against bacterial contamination and will accelerate a regenerative response of the wound. Silver sulfadiazine (SSD) is used to prevent wound infection. Hyaluronic acid (HA) is an extracellular matrix component involved in tissue regeneration. This retrospective study was conducted to evaluate the effectiveness of cream and gauze pads based on hyaluronic acid at low molecular weight (200 kDa) and silver sulfadiazine 1% in the wound healing process. In addition, we examined SSD action on biofilms in vitro and on animal wounds, obtaining positive outcomes therefrom. Materials and Methods: We selected 80 patients with complicated chronic wounds of different etiologies, including diabetes mellitus (10), post-traumatic ulcers (45), burns (15), and superficial abrasion (10). Results: After 8 weeks, ulcer size was decreased in 95 ± 2% of the treated patients; a significant reduction in the inflammatory process was observed from day 14 onwards (p < 0.01 vs. baseline), considering improvement of the surrounding skin and reduction of the bacterial load. The SSD treatment decreased bacterial colony proliferation, both in planktonic state and in biofilm, in a dose-dependent manner on the wound but inhibited the development of tissue granulation at the highest dose (800 µg/wound). Conclusions: In conclusion, the combined action of SSD and HA is clinically effective in improving wound healing.


Assuntos
Ácido Hialurônico , Sulfadiazina de Prata , Animais , Biofilmes , Humanos , Ácido Hialurônico/farmacologia , Ácido Hialurônico/uso terapêutico , Estudos Retrospectivos , Sulfadiazina de Prata/farmacologia , Sulfadiazina de Prata/uso terapêutico , Cicatrização
14.
Medicina (Kaunas) ; 58(9)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36143872

RESUMO

Background and Objective: Acute Achilles tendon rupture (AATR) is a common injury with a significant impact on daily living. Although various systematic reviews and meta-analyses have been written on the topic, no actual consensus exists on the best treatment. We aimed to collect the highest quality of evidence on the subject and to produce a document to which to refer, from the diagnosis to the final treatment. Material and Methods: Inclusion criteria were systematic reviews discussing Achilles tendon rupture, concerning either diagnostic criteria, classification, or treatment; English language; clearly stated inclusion and exclusion criteria for patients' selection. Results: Thirteen systematic reviews were included in the study. A strong consensus exists about the higher risk of re-rupture associated with non-operative treatment and a higher risk of complications associated with surgical repair. Conclusions: The combination of minimally invasive repair and accelerated functional rehabilitation seems to offer the best results in the treatment of Achilles tendon rupture.


Assuntos
Tendão do Calcâneo , Traumatismos do Tornozelo , Traumatismos dos Tendões , Tendão do Calcâneo/lesões , Doença Aguda , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Ruptura/diagnóstico , Ruptura/terapia , Traumatismos dos Tendões/diagnóstico , Traumatismos dos Tendões/terapia , Resultado do Tratamento
15.
Sensors (Basel) ; 21(18)2021 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-34577419

RESUMO

In this manuscript, an optically passive fiber Bragg grating (FBG) interrogation system able to perform high-frequency measurement is proposed. The idea is mainly based on the use of an arrayed waveguide grating (AWG) device which is used to discriminate the fiber optic sensor (FOS) wavelength encoded response under test in function of its output channels. As made clear by the theoretical model studied in the proposed manuscript, the Bragg wavelength shift can be detected as in linear dependence with the proposed interrogation function which changes with the voltage produced by two (or more) adjacent AWG output channels. To prove the feasibility of the system, some experimental analyses are conducted with a custom electrical module characterized by high-speed and low-noise operational amplifiers. As static measurements, three FBGs with different full width at half maximum (FWHM) have been monitored under wide-range wavelength variation; while, as dynamic measurement, one FBG, glued onto a metal plate, in order to sense the vibration at low and high frequency, was detected. The output signals have been processed by a digital acquisition (DAQ) board and a graphical user interface (GUI). The presented work highlights the characteristics of the proposed idea as competitor among the entire class of interrogation systems currently used. This is because here, the main device, that is the AWG, is passive and reliable, without the need to use modulation signals, or moving parts, that affect the speed of the system. In addition, the innovative multi-channel detection algorithm allows the use of any type of FOS without the need to have a perfectly match of spectra. Moreover, it is also characterized by a high dynamic range without loss of sensitivity.


Assuntos
Tecnologia de Fibra Óptica , Monitorização Fisiológica
16.
Aesthetic Plast Surg ; 45(5): 2036-2047, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33543344

RESUMO

BACKGROUND: The objective of this clinical review is to provide an overview of the use of breast implants after capsular contracture (CC) surgical treatment, with a focus on type of implants used. Furthermore, our experience in this field is also reviewed. METHODS: MEDLINE, EMBASE, Web of Science, Scopus, the Cochrane Central, and Google Scholar databases were reviewed to identify literature related to surgical treatment of capsular contracture and implant replacement. Each article was reviewed by two independent reviewers to ensure all relevant publications were identified. The literature search identified 54 applicable articles. Of these, 26 were found to have a therapeutic level of evidence. The reference lists in each relevant paper were screened manually to include relevant papers not found through the initial search. RESULTS: Only four articles report the replacement of implants after surgical treatment of capsular contracture. Six articles reported an implant exchange with only smooth silicone gel filled implants. Two reviews advice to use smooth implants in implant replacement. CONCLUSION: With our expertise in the field and the results of this up-to-date literature review, it can be concluded that implant exchange is recommended in case of breast revision for capsular contracture, and the use of subpectoral smooth silicone gel breast implants is a good option after surgical treatment in patients with primary or recurrence Baker III-IV. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Implante Mamário , Implantes de Mama , Contratura , Implante Mamário/efeitos adversos , Implantes de Mama/efeitos adversos , Humanos , Contratura Capsular em Implantes/etiologia , Contratura Capsular em Implantes/cirurgia , Reoperação , Géis de Silicone
17.
Int J Mol Sci ; 22(19)2021 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-34638538

RESUMO

Osteoarthritis (OA) is a chronic debilitating disorder causing pain and gradual degeneration of weight-bearing joints with detrimental effects on cartilage volume as well as cartilage damage, generating inflammation in the joint structure. The etiology of OA is multifactorial. Currently, therapies are mainly addressing the physical and occupational aspects of osteoarthritis using pharmacologic pain treatment and/or surgery to manage the symptomatology of the disease with no specific regard to disease progression or prevention. Herein, we highlight alternative therapeutics for OA specifically considering innovative and encouraging translational methods with the use of adipose mesenchymal stem cells.


Assuntos
Tecido Adiposo/citologia , Condrócitos/transplante , Transplante de Células-Tronco Mesenquimais/métodos , Osteoartrite do Joelho/terapia , Medicina Regenerativa/métodos , Cartilagem Articular/patologia , Humanos , Células-Tronco Mesenquimais/citologia , Osteoartrite do Joelho/patologia , Estresse Mecânico
18.
BMC Musculoskelet Disord ; 21(1): 590, 2020 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-32878622

RESUMO

BACKGROUND: Distal Phalanx (DP) fractures are the most common hand injuries. Bone fixation associated with soft tissue reconstruction, is often required to ensure more effective outcomes. The aim of the present study is to compare functional outcomes of DP fractures surgically treated with crossed manual drilled 23 Gauge needles vs crossed Kirschner-wires (k-wire). METHODS: Clinical data included analysis of patient demographics, range of motion (ROM), and complications. Radiographic assessment considered fracture type, location, fracture displacement, and radiographic union. Functional outcomes analysis was performed.The statistical significance was assessed at the level of probability lower than 5%. RESULTS: A total of 60 patients from 2012 to 2015 were retrospectively enrolled and among them 12 patients suffering from diabetes or current smokers. A total of 60 DP fractures were treated, 32 with needles (group A) and 28 with k-wire fixation (group B). Time to union, showed in different time points, was significantly lower in group A (≤ 40 days, p = 0.023*) compared to group B. ROM of the distal interphalangeal joint at six months follow-up was 60° in group A and 40° in group B. A significant improvement was observed (p = 0.001*) in the 23 G needle treated group. Functional outcome analysis showed that VAS was significantly lower in group A compared to group B (p = 0.023*). CONCLUSION: Our study showed that the 23 G needle yielded satisfactory results in terms of time to union and range of motion compared to k-wire fixation especially for tuft and shaft DP fractures. Therefore, should be a valid alternative to k-wire fixation in selected patients.


Assuntos
Traumatismos dos Dedos , Fraturas Ósseas , Fios Ortopédicos , Traumatismos dos Dedos/diagnóstico por imagem , Traumatismos dos Dedos/cirurgia , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Agulhas , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
19.
Aesthetic Plast Surg ; 44(5): 1947-1950, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32556449

RESUMO

In this period of the Covid-19 pandemic, a protective mask has become a common object of use to contain virus transmission. The imminent need for masks has led many governments to produce them, including surgical masks with elastic loops or masks with side cuts at the ears. Among those on the market, surgical masks with elastic loops are the ones most chosen by parents for their children. These elastics cause constant compression on the skin and, consequently, on the cartilage of the auricle, leading to erythematous and painful lesions of the retroauricular skin when the masks are used for many hours a day. Pre-adolescent children have undeveloped auricular cartilage with less resistance to deformation; prolonged pressure from the elastic loops of the mask at the hollow or, even worse, at the anthelix level can influence the correct growth and angulation of the outer ear. In fact, unlike when using conservative methods for the treatment of protruding ears, this prolonged pressure can increase the cephaloauricular angle of the outer auricle. It is important for the authorities supplying the masks to be aware of this potential risk and for alternative solutions to be found while maintaining the possibility of legitimate prevention of the potential spread of the virus.Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to the table of contents or the online instructions to authors www.springer.com/00266 .


Assuntos
Infecções por Coronavirus/prevenção & controle , Pavilhão Auricular/anormalidades , Máscaras/efeitos adversos , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Fatores Etários , COVID-19 , Criança , Pré-Escolar , Infecções por Coronavirus/epidemiologia , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pandemias/estatística & dados numéricos , Pneumonia Viral/epidemiologia , Prevenção Primária/métodos
20.
Int J Mol Sci ; 21(9)2020 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-32349299

RESUMO

Autologous fat grafting is a surgical technique in which adipose tissue is transferred from one area of the body to another, in order to reconstruct or regenerate damaged or injured tissues. Before reinjection, adipose tissue needs to be purified from blood and cellular debris to avoid inflammation and preserve the graft viability. To perform this purification, different enzymatic and mechanical methods can be used. In this study, we characterized in vitro the product of a closed automatic device based on mechanical disaggregation, named Rigenera®, focusing on two sites of adipose tissue harvesting. At first, we optimized the Rigenera® operating timing, demonstrating that 60 s of treatment allows a higher cellular yield, in terms of the cell number and growth rate. This result optimizes the mechanical disaggregation and it can increase the clinical efficiency of the final product. When comparing the extracted adipose samples from the thigh and abdomen, our results showed that the thigh provides a higher number of mesenchymal-like cells, with a faster replication rate and a higher ability to form colonies. We can conclude that by collecting adipose tissue from the thigh and treating it with the Rigenera® device for 60 s, it is possible to obtain the most efficient product.


Assuntos
Tecido Adiposo/citologia , Células-Tronco/citologia , Células-Tronco/metabolismo , Abdome , Biomarcadores , Diferenciação Celular , Separação Celular , Sobrevivência Celular , Humanos , Imunofenotipagem , Coxa da Perna
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA