Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Exp Physiol ; 106(1): 233-243, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32462715

RESUMO

NEW FINDINGS: What is the central question of this study? Fire service instructors are frequently exposed to live fire scenarios, representing the most extreme chronic occupational heat exposure. These individuals report a series of unique health issues. We sought to identify whether the number of exposures completed was associated with inflammatory and immunological markers and symptoms of ill health. What is the main finding and its importance? Fire service instructors exhibit greater levels of inflammatory markers in comparison to firefighters. The number of exposures to fire is positively related to the prevalence of ill health and inflammation. Implementation of a proposed limit of nine exposures per month might be appropriate to minimize health issues. ABSTRACT: Fire Service Instructors (FSIs) experience ∼10 times more fire exposures than firefighters (FFs), and the increased physiological stress from this potentially puts them at risk of ill health and future cardiac events. The aim of the study was to establish whether FSIs exhibit elevated biomarkers associated with cardiac event risk, identify whether FSIs experience systemic inflammation linked to the frequency of fire exposure and evaluate a proposed exposure limit of nine exposures per month. Blood samples were collected from 110 Fire Service personnel (mean ± SD, age,44 ± 7 years; height, 178.1 ± 7.1 cm; and body mass, 84.3 ± 12.0 kg; FSIs n = 53 and FFs n = 57) for biomarker analysis. Work history details were collected from all participants. Participants with biomarker concentrations above healthy reference ranges were classified as being 'at risk'. The neutrophil-to-lymphocyte ratio, platelet count, cardiac troponin T, interleukin (IL)-6, IL-1ß, C-reactive protein and immunoglobulin G were greater in FSIs than in FFs (P < 0.05). Multiple regression analysis revealed that 18.8% of IL-6, 24.9% of IL-1ß, 29.2% of C-reactive protein and 10.9% of immunoglobulin G variance could be explained by the number of exposures to heat per month. Odds ratios revealed that those FSIs above the nine per month exposure limit were six to 12 times more likely to be classified as 'at risk' and were 16 times more likely to experience symptoms of ill health. Increased cytokine levels suggest that FSIs experience systemic inflammation, which is related to symptoms of ill health. We propose that an exposure limit could reduce the prevalence of these biomarker risk factors and ill health.


Assuntos
Temperatura Alta/efeitos adversos , Inflamação/sangue , Exposição Ocupacional , Estresse Fisiológico/fisiologia , Adulto , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , Bombeiros , Humanos , Masculino , Pessoa de Meia-Idade
2.
J Sports Sci ; 37(2): 163-172, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29932816

RESUMO

This study sought to establish perceptions of elite endurance athletes on the role and worth of altitude training. Elite British endurance runners were surveyed to identify the altitude and hypoxic training methods utilised, along with reasons for use, and any situational, cultural and behaviour factors influencing these. Prior to the 2012 Olympics Games, 39 athletes and 20 support staff (coaches/practitioners) completed an internet-based survey to establish differences between current practices and the accepted "best-practice". Almost all of the athletes (98%) and support staff (95%) surveyed had utilised altitude and hypoxic training, or had advised it to athletes. 75% of athletes believed altitude and hypoxia to be a "very important" factor in their training regime, with 50% of support staff believing the same. Athletes and support staff were in agreement of the methods of altitude training utilised (i.e. 'hypoxic dose' and strategy), with camps lasting 3-4 weeks at 1,500-2,500 m being the most popular. Athletes and support staff are utilising altitude and hypoxic training methods in a manner agreeing with research-based suggestions. The survey identified a number of specific challenges and priorities, which could provide scope to optimise future altitude training methods for endurance performance in these elite groups.


Assuntos
Altitude , Atletas/psicologia , Percepção/fisiologia , Condicionamento Físico Humano/métodos , Resistência Física/fisiologia , Corrida/fisiologia , Comportamento Competitivo/fisiologia , Estudos Transversais , Humanos , Hipóxia , Tutoria , Inquéritos e Questionários , Reino Unido
3.
J Therm Biol ; 82: 1-9, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31128636

RESUMO

OBJECTIVES: Fire Service Instructors (FSI) experience repeated fire exposures a median of 13 ±â€¯8 times a month; consequently they may develop an acclimatised state. However, the chronic immunological implications of heat acclimation are yet to be understood. This study aimed to establish whether FSI exhibit an increased heat tolerance and altered immunological response to heat exposures, compared to non-exposed individuals. The study also aimed to identify if heat tolerance is related to symptoms of ill health. METHODS: Twenty-two participants were recruited: 11 FSI (age: 41 ±â€¯7 yrs, body mass: 77.4 ±â€¯12.2 kg, height: 174.1 ±â€¯8.2 cm) and 11 non-exposed controls (CON) (age: 41 ±â€¯7 yrs, body mass: 75.9 ±â€¯12.2 kg, height: 177.0 ±â€¯8.1 cm). Participants completed a 40 min heat occupational tolerance test (HOTT) exercising at 6 W kg-1 (50.0 ±â€¯1.0 °C, 12.3 ±â€¯3.3% relative humidity) on two occasions, separated by 2 months. Physiological and perceptual measures were collected throughout and venous blood samples were collected prior to and post exposure. RESULTS: FSI displayed significantly reduced peak rectal temperature (Tre) (-0.42 °C), change in Tre (-0.33 °C), and thermal sensation (-1.0) and increased sweat rate (+0.25 L h-1) at the end of the HOTT compared to CON (p < 0.05). FSI exhibited similar responses to the HOTT as CON for all haematological variables. However, resting interleukin-6, interleukin-1ß, and immunoglobulin G were significantly greater in FSI than CON. There was no difference in responses following the 2 month working period. FSI peak Tre was negatively correlated with symptoms of ill health (rpb = -0.473, p = 0.026) and the number of fire exposures in the previous 2 weeks (rs = -0.589, p = 0.004). CONCLUSION: Despite increased heat tolerance compared to non-exposed individuals, FSI may develop a maladaptation to repeated fire exposures, with elevated resting cytokine levels and an increased prevalence of ill health symptoms.


Assuntos
Termotolerância , Adulto , Regulação da Temperatura Corporal , Teste de Esforço , Bombeiros , Resposta ao Choque Térmico , Temperatura Alta , Humanos , Imunoglobulina G/sangue , Inflamação/sangue , Inflamação/etiologia , Interleucina-1beta/sangue , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos
4.
J Occup Environ Hyg ; 16(1): 27-40, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30277854

RESUMO

Fire service instructors (FSI) regularly experience different types of fire exercises, however the strain experienced from these scenarios is not well understood. This study aims to identify the physiological and perceptual strain of Fire Service Instructors (FSI) to three training exercises: DEMO, ATTACK, COMPARTMENT, and the different roles performed: SETTER, INSTRUCTOR. The study also aims to assess the effect that different exercise patterns over a day (BOX, MULTI, COMBINATION) have on immunological responses. Sixteen FSI (age: 41 ± 8 years, body mass: 83.7 ± 6.7 kg, height: 177.0 ± 6.7 cm) were recruited, with 10 FSI completing the three exercises. Physiological and perceptual measures were collected prior to and immediately post each exercise. Venous blood samples were collected at the beginning and end of each day. One-way analysis of variance (ANOVA) were conducted to assess differences in physiological variables between exercise types, independent samples t-tests were conducted between roles. Day changes in hematological variables were assessed by paired sample t-tests and analyzed by one-way ANOVAs to identify differences between exercise patterns. The COMPARTMENT exercise resulted in a greater change in rectal temperature (ΔTre) (0.49 ± 0.28 °C) than both the DEMO (0.23 ± 0.19 °C, p = 0.045) and ATTACK (0.27 ± 0.22 °C, p = 0.016). Within the COMPARTMENT exercise, the SETTER resulted in a greater ΔTre and rating of perceived exertion than the INSTRUCTOR (0.67 ± 0.29 °C vs. 0.43 ± 0.18 °C, p = 0.027 and 14 ± 2 vs. 11 ± 2, p = 0.001, respectively). Following a day of fire exercises white blood cells (WBC), neutrophils, lymphocytes (LYMPH), monocytes (MONO), platelets (PLT), mean platelet volume (MPV), Interleukin (IL)-6, and cardiac troponin T (cTnT) all increased (p < 0.05). Exercise patterns containing a COMPARTMENT exercise resulted in greater PLT, MPV, and IL-6. Total daily variation in ΔTre was correlated with post-exercise WBC, MONO, and LYMPH. COMPARTMENT exercises produce the greatest physiological strain, with the SETTER role within this exercise causing the greatest ΔTre. Although predominately physiological responses remain within safe limits. Exercise patterns that include a COMPARTMENT exercise also generate a greater inflammatory response.


Assuntos
Bombeiros/educação , Incêndios , Exposição Ocupacional/efeitos adversos , Adulto , Contagem de Células Sanguíneas , Temperatura Corporal/fisiologia , Feminino , Temperatura Alta , Humanos , Inflamação/sangue , Interleucina-6/sangue , Masculino , Pessoa de Meia-Idade , Estresse Ocupacional/fisiopatologia , Troponina T/sangue , Reino Unido
5.
J Therm Biol ; 78: 42-50, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30509666

RESUMO

Heat tolerance tests identify those susceptible to heat illnesses and monitor heat adaptations. Currently, tolerance tests do not replicate the uncompensable heat strain environments experienced in some occupations. In addition, tests can take up to 2 h to complete, and cannot offer intra and inter individual comparisons, due to the use of a fixed exercise intensity. This study aimed to assess the validity and reliability of a new heat occupational tolerance test (HOTT: 40 min at 6 W kg-1 metabolic heat production, 50 °C 10% RH, in protective clothing) to the standard heat tolerance test (HTT: 2 h walk at 5 km h-1 1% gradient, 40 °C 40% RH, in shorts and t-shirt). Eighteen participants (age: 21 ±â€¯3 yrs, body mass: 81.3 ±â€¯5.9 kg) completed trials to assess the validity and/or reliability of the HOTT. Peak rectal temperature (Tre) displayed strong agreement and low measurement error (0.19 °C) between HTT (38.7 ±â€¯0.4 °C) and HOTT (38.6 ±â€¯0.4 °C). Strong agreement was also displayed for physiological and perceptual measures between the two HOTT trials, including peak Tre (38.5 ±â€¯0.4 °C vs. 38.5 ±â€¯0.4 °C) and peak heart rate (182 ±â€¯20 b min-1 vs. 182 ±â€¯21 b min-1). The HOTT is the first tolerance test that assesses individuals' responses whilst wearing protective clothing in high temperatures. It can consistently identify individuals' levels of heat tolerance within a reduced time frame. In addition, it allows for participant monitoring over time and comparisons between individuals to be made. A continuum based approach is recommended when assessing individuals' responses to the HOTT.


Assuntos
Transtornos de Estresse por Calor/fisiopatologia , Monitorização Fisiológica/métodos , Doenças Profissionais/fisiopatologia , Termotolerância , Temperatura Corporal , Estudos de Viabilidade , Transtornos de Estresse por Calor/urina , Humanos , Masculino , Monitorização Fisiológica/normas , Doenças Profissionais/urina , Distribuição Aleatória , Respiração , Adulto Jovem
6.
J Strength Cond Res ; 32(5): 1366-1375, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28486332

RESUMO

James, CA, Richardson, AJ, Watt, PW, Willmott, AGB, Gibson, OR, and Maxwell, NS. Short-term heat acclimation and precooling, independently and combined, improve 5-km time trial performance in the heat. J Strength Cond Res 32(5): 1366-1375, 2018-Following heat acclimation (HA), endurance running performance remains impaired in hot vs. temperate conditions. Combining HA with precooling (PC) demonstrates no additive benefit in intermittent sprint, or continuous cycling exercise protocols, during which heat strain may be less severe compared to endurance running. This study investigated the effect of short-term HA (STHA) combined with mixed methods PC, on endurance running performance and directly compared PC and HA. Nine amateur trained runners completed 5-km treadmill time trials (TTs) in the heat (32° C, 60% relative humidity) under 4 conditions; no intervention (CON), PC, short-term HA (5 days-HA) and STHA with PC (HA + PC). Mean (±SD) performance times were; CON 1,476 (173) seconds, PC 1,421 (146) seconds, HA 1,378 (116) seconds and HA + PC 1,373 (121) seconds. This equated to the following improvements versus CON; PC -3.7%, HA -6.6% and HA + PC -7.0%. Statistical differences were only observed between HA and CON (p = 0.004, d = 0.68, 95% CI [-0.27 to 1.63]) however, similar effect sizes were observed for HA + PC vs. CON (d = 0.70, 95% CI [-0.25 to 1.65]), with smaller effects between PC vs. CON (d = 0.34, 95% CI [-0.59 to 1.27]), HA vs. PC (d = 0.33, 95% CI [-0.60 to 1.26]) and HA + PC vs. PC (d = 0.36, 95% CI [-0.57 to 1.29]). Pilot testing revealed a TT typical error of 16 seconds (1.2%). Precooling offered no further benefit to performance in the acclimated individual, despite modest alleviation of physiological strain. Maintenance of running speed in HA + PC, despite reduced physiological strain, may indicate an inappropriate pacing strategy therefore, further familiarization is recommended to optimize a combined strategy. Finally, these data indicate HA, achieved through cycle training, yields a larger ergogenic effect than PC on 5-km running performance in the heat, although PC remains beneficial when HA is not possible.


Assuntos
Aclimatação/fisiologia , Regulação da Temperatura Corporal/fisiologia , Temperatura Baixa , Temperatura Alta , Corrida/fisiologia , Adulto , Atletas , Desempenho Atlético/fisiologia , Teste de Esforço , Feminino , Humanos , Masculino
7.
J Sports Sci ; 35(22): 2249-2256, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27935427

RESUMO

Multistage, ultra-endurance events in hot, humid conditions necessitate thermal adaptation, often achieved through short term heat acclimation (STHA), to improve performance by reducing thermoregulatory strain and perceptions of heat stress. This study investigated the physiological, perceptual and immunological responses to STHA prior to the Marathon des Sables. Eight athletes (age 42 ± 4 years and body mass 81.9 ± 15.0 kg) completed 4 days of controlled hyperthermia STHA (60 min·day‒1, 45°C and 30% relative humidity). Pre, during and post sessions, physiological and perceptual measures were recorded. Immunological measures were recorded pre-post sessions 1 and 4. STHA improved thermal comfort (P = 0.02), sensation (P = 0.03) and perceived exertion (P = 0.04). A dissociated relationship between perceptual fatigue and Tre was evident after STHA, with reductions in perceived Physical (P = 0.04) and General (P = 0.04) fatigue. Exercising Tre and HR did not change (P > 0.05) however, sweat rate increased 14% (P = 0.02). No changes were found in white blood cell counts or content (P > 0.05). Four days of STHA facilitates effective perceptual adaptations, without compromising immune status prior to an ultra-endurance race in heat stress. A greater physiological strain is required to confer optimal physiological adaptations.


Assuntos
Aclimatação , Clima Desértico , Temperatura Alta , Corrida/fisiologia , Aclimatação/imunologia , Aclimatação/fisiologia , Adulto , Atletas , Humanos , Masculino , Sudorese
8.
J Therm Biol ; 63: 41-48, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28010814

RESUMO

Fire Service Instructors frequently experience high levels of physiological and perceptual strain during live fire exposures. Instructors are also at risk of cardiovascular illnesses, with cardiac death being the greatest cause of fire fighter death. Current practice for UK instructors is to select undergarment type based on personal preference, between a boiler suit (BOILER) and a wicking base layer (WBL). Research suggests that shorts and t-shirt (SHORTS) may also be a beneficial alternative undergarment choice. The UK South East Fire Service requested an investigation to identify if undergarment selection can lessen the strain experienced by instructors, and reduce the acute inflammatory response to fire exposures. Eight males completed three 45min sessions in a heat chamber (49.5±1.4°C and 16.9±4.3% RH) whilst performing intermittent walking. At the end of heat exposure change in heart rate was not effected by garment type (p=0.061, ηp2=0.373). Change in rectal temperature was different between garments (p=0.009, ηp2=0.271), with trends suggesting that BOILER resulted in a greater change (1.03±0.60°C) than SHORTS (0.76±0.37°C, p=0.589, d=0.21) and WBL (0.72±0.33°C, p=0.545, d=0.25). Interleukin-6 post exposure was greater for BOILER (6.96±0.28pgmL-1) than both SHORTS (6.59±0.30pgmL-1, p=0.043, d=0.42) and WBL (6.45±0.43pgmL-1, p=0.031, d=0.51). Overall, undergarment type had little impact on physiological or perceptual strain. However, wearing WBL or SHORTS may reduce the inflammatory response, and consequently decrease the risk of cardiovascular events.


Assuntos
Doenças Cardiovasculares/prevenção & controle , Bombeiros , Temperatura Alta/efeitos adversos , Interleucina-6/sangue , Doenças Profissionais/prevenção & controle , Roupa de Proteção/normas , Estresse Psicológico/prevenção & controle , Temperatura Corporal , Doenças Cardiovasculares/etiologia , Humanos , Masculino , Doenças Profissionais/etiologia , Percepção , Roupa de Proteção/efeitos adversos , Estresse Psicológico/etiologia , Adulto Jovem
9.
Eur J Appl Physiol ; 116(9): 1735-45, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27406142

RESUMO

PURPOSE: Ischaemic preconditioning (IP) has been shown to be ergogenic for endurance performance in normothermic conditions and alleviate physiological strain under hypoxia, potentially through haemodynamic and/or metabolic mechanisms. Exertional hyperthermia is characterised by competition for blood flow between the muscles and skin, an enhanced metabolic strain and impaired endurance performance. This study investigated the effect of IP on the determinants of endurance performance, through an incremental exercise test in the heat. METHOD: Eleven males completed two graded exercise tests in the heat (32 °C, 62 % RH) until volitional exhaustion, preceded by IP (4 × 5 min 220 mmHg bilateral upper leg occlusion) or a control (CON) condition (4 × 5-min 50 mmHg bilateral). RESULT: IP did not improve running speeds at fixed blood lactate concentrations of 2 and 4 mMol L(-1) (p = 0.828), or affect blood glucose concentration throughout the trial [mean (±SD); CON 5.03 (0.94) mMol L(-1), IP 5.47 (1.38) mMol L(-1), p = 0.260). There was no difference in [Formula: see text]O2max [CON 55.5 (3.7) mL kg(-1) min(-1), IP 56.0 (2.6) mL kg(-1) min(-1), p = 0.436], average running economy [CON 222.3 (18.0) mL kg(-1) km(-1), IP 218.9 (16.5) mL kg(-1) km(-1), p = 0.125], or total running time during graded exercise [CON 347 (42) s, IP 379 (68) s, p = 0.166]. The IP procedure did not change muscle temperature [CON ∆ = 0.55 (0.57) °C, IP ∆ = 0.78 (0.85) °C, p = 0.568], but did reduce T CORE during exercise (~-0.1 °C, p = 0.001). CONCLUSION: The novel application of IP prior to exercise in the heat does not enhance the determinants of endurance performance. For events where IP appears ergogenic, muscle warming strategies are unnecessary as IP does not influence deep muscle temperature.


Assuntos
Desempenho Atlético/fisiologia , Resposta ao Choque Térmico/fisiologia , Precondicionamento Isquêmico/métodos , Consumo de Oxigênio/fisiologia , Resistência Física/fisiologia , Corrida/fisiologia , Aclimatação/fisiologia , Adulto , Regulação da Temperatura Corporal , Temperatura Alta , Humanos , Ácido Láctico/sangue , Masculino
10.
J Therm Biol ; 58: 106-14, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27157340

RESUMO

AIM: Fire Service Instructors (FSI) are exposed to many repeated periods of high environmental temperatures when training firefighters. Such repeated exposures will impose significant strains on the function of instructors. We aimed to measure the effects of a training programme including repeated exposures to heat, termed "Wears" in the fire service, on the physiological, psychological some immunological markers of Fire Service Instructors. METHODS: Six FSI and six physiologically matched controls completed blood and cardiovascular tests pre and post a 4wk heat instruction training block, controls completed the tests only. FSI were given a 7wk period of no heat exposure prior to starting the training. Physiological and perceptual measures were taken pre and post the first and last Wear of the 4wk training protocol. RESULTS: There were acute effects of a Wear on core temperature and physiological strain index, as well as measures of fatigue. The acute exposure to heat during a Wear led to a consistent decrease in CRP (-10% to -40%), increased IL6 concentrations 33-45%) as well as increased RPE and TSS. Over the training programme significantly lower quantities of white cells, particularly neutrophils, leukocytes and monocytes were found in the FSI group. Between the start and the end of the 4 week training programme the FSI showed a significantly greater physiological strain index (PSI) to the Wears, which nearly doubled from 2.5 to 4.7 (p<0.05). CONCLUSION: Physiological and psychological measures indicate that FSI may be experiencing symptoms and changes to their health consistent with an overtraining type condition.


Assuntos
Bombeiros/educação , Bombeiros/psicologia , Resposta ao Choque Térmico , Inflamação/sangue , Inflamação/etiologia , Exposição Ocupacional/análise , Adulto , Contagem de Células Sanguíneas , Regulação da Temperatura Corporal , Proteína C-Reativa/análise , Incêndios , Frequência Cardíaca , Temperatura Alta/efeitos adversos , Humanos , Interleucina-6/sangue , Masculino , Exposição Ocupacional/efeitos adversos
11.
Wilderness Environ Med ; 26(2): 205-10, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25772827

RESUMO

OBJECTIVE: The 6-minute walk test (6MWT) is a reliable and valid tool for determining an individual's functional capacity, and has been used to predict summit success. The primary aim of the study was to evaluate whether a 6MWT in normobaric hypoxia could predict physiological responses and exercise performance at altitude. The secondary aim was to determine construct validity of the 6MWT for monitoring acclimatization to 3400 m (Cuzco, Peru). METHODS: Twenty-nine participants performed six 6MWTs in four conditions: normoxic outdoor (NO), normoxic treadmill (NT), and hypoxic treadmill (HT) were each performed once; and hypoxic outdoor (HO) was performed three times, at 42 hours (HO1), 138 hours (HO2), and 210 hours (HO3) after arrival at Cuzco. RESULTS: One-way analysis of variance revealed no difference (P>.05) between NO and HO1 for 6MWT distance. HT and HO protocols were comparable for the measurement of delta heart rate (HR) and post-test peripheral oxygen saturation (%Spo2; P>.05). Acclimatization was evidenced by reductions (P<.05) in resting HR and respiratory rate (RR) between HO1, HO2, and HO3, and preservation of Spo2 between HO1 and HO2. Postexercise HR and RR were not different (P>.05) with acclimatization. The duration to ascend to 4215 m on a trek was moderately correlated (P<.05) to HR during the trek and the 6MWT distance during HT; no other physiological markers predicted performance. CONCLUSIONS: The 6MWT is a simple, time-efficient tool for predicting physiological responses to simulated and actual altitude, which are comparable. The 6MWT is effective at monitoring elements of acclimatization to moderate altitude.


Assuntos
Aclimatação , Altitude , Oxigênio/metabolismo , Caminhada/fisiologia , Adolescente , Adulto , Feminino , Humanos , Hipóxia , Masculino , Fatores de Tempo , Adulto Jovem
12.
J Sci Med Sport ; 26(1): 14-18, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36435729

RESUMO

OBJECTIVES: Endurance exercise is known to cause a rise in serum creatinine. It is not known to what extent this rise reflects renal stress and a potential acute kidney injury (AKI). Increases in Insulin Like Growth Factor Binding Protein 7 (IGFBP7) and Tissue Inhibitor of Metalloprotinases-2 (TIMP-2), urinary biomarkers of cell cycle arrest and renal stress, are associated with the development of AKI in clinical populations. DESIGN: Repeated measures study. METHODS: Runners were recruited at the 2019 Brighton Marathon (UK) and provided urine and blood samples at baseline, immediately post-race and 24 h post-race. Serum creatinine, urinary creatinine and urinary IGFBP7 and TIMP-2 were analysed from the samples. RESULTS: Seventy nine participants (23 females, 56 males), aged 43 ±â€¯10 yrs. (mean ±â€¯SD), finish time 243 ±â€¯40mins were included for analysis. Serum creatinine increased over the race by 40 ±â€¯26% (p < 0.001), TIMP-2 increased by 555 ±â€¯697% (p < 0.001) and IGFBP7 increased by 1094 ±â€¯1491% (p < 0.001) over the race. A subset of twenty-two participants supplied samples 24 h post-race, reporting values similar to baseline for all variables. CONCLUSIONS: This study is the first to report large rises in IGFBP7 and TIMP-2 following marathon running. This suggests that rises in creatinine are not fully explained by changes in production and clearance and marathon running induces a state of kidney stress and potential injury.


Assuntos
Injúria Renal Aguda , Corrida de Maratona , Masculino , Feminino , Humanos , Creatinina , Inibidor Tecidual de Metaloproteinase-2 , Biomarcadores , Pontos de Checagem do Ciclo Celular , Injúria Renal Aguda/diagnóstico
13.
Arch Environ Occup Health ; 74(6): 322-330, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29621422

RESUMO

Analysis of Fire Service Instructors (FSI) working practices and health is needed to minimise health risks related to heat illness, cardiovascular events and immunological stress. Online surveys were distributed to UK FSI and Firefighters (FF). One hundred and thirty FSI (age: 43 ± 7yrs) and 232 FF (age: 41 ± 8yrs) responded. FSI experienced 2-10 live fires per week, with 45% of FSI reporting management does not set a limit on the number of exposures. Few FSI followed hydration guidelines, or cooling methods. New symptoms of ill health were reported by 41% of FSI and 21% of FF. FSI with ≥11 Breathing Apparatus exposures per month were 4.5 times (95% CI 1.33-15.09) more likely to experience new symptoms. A large proportion of FSI are experiencing new symptoms of illness after starting their career, and guidelines on exposure and hydration are not universally in place to reduce the risk of future health problems.


Assuntos
Bombeiros , Nível de Saúde , Saúde Ocupacional , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional , Inquéritos e Questionários , Reino Unido
14.
Womens Health Issues ; 29(5): 424-431, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30930075

RESUMO

OBJECTIVES: This study aimed to identify specific health and well-being issues that women firefighters may experience as part of their daily working practices. Issues identified from this under-represented population can drive future research, education, and strategy to guide safety and health practices. METHODS: A total of 840 women firefighters from 14 separate countries (255 United Kingdom and Ireland, 320 North America, 177 Australasia, and 88 mainland Europe) completed the survey over a 4-month period. Questions related to general health and well-being and role-specific health concerns, gender-related issues, and available exercise facilities. RESULTS: Women firefighters in North America reported a higher prevalence of lower back (49%) and lower limb (51%) injuries than all other groups. North American respondents reported more heat illnesses (45%) than respondents from other places (36%). Although many participants did not respond, of those who did, 39% thought the menstrual cycle (199/512) or menopause (55/151) affected their work, and 36% were concerned for their ability to meet future job demands. Sixteen percent felt confident they could complete the role after 60 years of age. Women firefighters identified a lack of strength and conditioning support (50%) or lack of gym access (21%). There appears to be poor availability of female-specific personal protective equipment, with availability greatest in the United Kingdom (66%) compared with the sample as a whole (42%). CONCLUSIONS: There is a need for female-specific strength and conditioning support and facilities to decrease injury and illness risk and improve longevity. Research and education into gynecological issues, heat exposure, and their effects on women firefighters' fertility and cancer risk is required.


Assuntos
Acidentes de Trabalho/estatística & dados numéricos , Bombeiros/psicologia , Bombeiros/estatística & dados numéricos , Doenças Profissionais/epidemiologia , Saúde Ocupacional/estatística & dados numéricos , Qualidade de Vida/psicologia , Saúde da Mulher , Adulto , Australásia , Europa (Continente) , Exercício Físico/fisiologia , Feminino , Humanos , Dor Lombar/epidemiologia , Masculino , Pessoa de Meia-Idade , América do Norte , Aptidão Física , Prevalência , Inquéritos e Questionários , Local de Trabalho , Ferimentos e Lesões/epidemiologia
15.
Appl Ergon ; 70: 26-33, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29866317

RESUMO

This study aimed to identify a pre-cooling method to reduce the physiological and perceptual strain, and the inflammatory response, experienced by individuals who wear personal protective equipment. Eleven males (age 20 ±â€¯2 years, weight 75.8 ±â€¯9.3 kg, height 177.1 ±â€¯5.0 cm) completed 15min pre-cooling (phase change vest [PCV], forearm cooling [ARM], ice slurry consumption [ICE], or a no cooling control [CON]) and 45min intermittent walk (4  km h-1, 1% gradient) in 49.5 ±â€¯0.6 °C and 15.4 ±â€¯1.0% RH, whilst wearing firefighter ensemble. ICE reduced rectal temperature (Tre) before heat exposure compared to CON (ΔTre: 0.24 ±â€¯0.09 °C, p < 0.001, d = 0.38) and during exercise compared to CON, ARM, and PCV (p = 0.026, ηp2 = 0.145). Thermal sensation was reduced in ICE and ARM vs. CON (p = 0.018, ηp2 = 0.150). Interleukin-6 was not affected by pre-cooling (p = 0.648, ηp2 = 0.032). It is recommended that those wearing protective equipment consume 500 ml of ice slurry 15min prior to work to reduce physiological and perceptual strain.


Assuntos
Crioterapia/métodos , Transtornos de Estresse por Calor/fisiopatologia , Temperatura Alta/efeitos adversos , Exposição Ocupacional/efeitos adversos , Saúde Ocupacional , Adolescente , Exercício Físico/fisiologia , Antebraço , Frequência Cardíaca , Transtornos de Estresse por Calor/prevenção & controle , Humanos , Gelo , Interleucina-6/sangue , Masculino , Consumo de Oxigênio , Equipamento de Proteção Individual/efeitos adversos , Temperatura Cutânea , Sensação Térmica , Adulto Jovem
16.
Appl Physiol Nutr Metab ; 42(3): 285-294, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28177747

RESUMO

This study investigated the effect of 5 days of controlled short-term heat acclimation (STHA) on the determinants of endurance performance and 5-km performance in runners, relative to the impairment afforded by moderate heat stress. A control group (CON), matched for total work and power output (2.7 W·kg-1), differentiated thermal and exercise contributions of STHA on exercise performance. Seventeen participants (10 STHA, 7 CON) completed graded exercise tests (GXTs) in cool (13 °C, 50% relative humidity (RH), pre-training) and hot conditions (32 °C, 60% RH, pre- and post-training), as well as 5-km time trials (TTs) in the heat, pre- and post-training. STHA reduced resting (p = 0.01) and exercising (p = 0.04) core temperature alongside a smaller change in thermal sensation (p = 0.04). Both groups improved the lactate threshold (LT, p = 0.021), lactate turnpoint (LTP, p = 0.005) and velocity at maximal oxygen consumption (vV̇O2max; p = 0.031) similarly. Statistical differences between training methods were observed in TT performance (STHA, -6.2(5.5)%; CON, -0.6(1.7)%, p = 0.029) and total running time during the GXT (STHA, +20.8(12.7)%; CON, +9.8(1.2)%, p = 0.006). There were large mean differences in change in maximal oxygen consumption between STHA +4.0(2.2) mL·kg-1·min-1 (7.3(4.0)%) and CON +1.9(3.7) mL·kg-1·min-1 (3.8(7.2)%). Running economy (RE) deteriorated following both training programmes (p = 0.008). Similarly, RE was impaired in the cool GXT, relative to the hot GXT (p = 0.004). STHA improved endurance running performance in comparison with work-matched normothermic training, despite equality of adaptation for typical determinants of performance (LT, LTP, vV̇O2max). Accordingly, these data highlight the ergogenic effect of STHA, potentially via greater improvements in maximal oxygen consumption and specific thermoregulatory and associated thermal perception adaptations absent in normothermic training.


Assuntos
Aclimatação , Desempenho Atlético , Temperatura Alta , Resistência Física , Corrida , Adolescente , Adulto , Índice de Massa Corporal , Regulação da Temperatura Corporal , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Estresse Fisiológico , Adulto Jovem
17.
Front Physiol ; 7: 332, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27536249

RESUMO

Sprint interval training (SIT) is an efficient intervention capable of improving aerobic capacity and exercise performance. This experiment aimed to determine differences in training adaptations and the inflammatory responses following 2 weeks of SIT (30 s maximal work, 4 min recovery; 4-7 repetitions) performed in normoxia or hypoxia. Forty-two untrained participants [(mean ± SD), age 21 ±1 years, body mass 72.1 ±11.4 kg, and height 173 ±10 cm] were equally and randomly assigned to one of three groups; control (CONT; no training, n = 14), normoxic (NORM; SIT in FiO2: 0.21, n = 14), and normobaric hypoxic (HYP; SIT in FiO2: 0.15, n = 14). Participants completed a [Formula: see text] test, a time to exhaustion (TTE) trial (power = 80% [Formula: see text]) and had hematological [hemoglobin (Hb), haematocrit (Hct)] and inflammatory markers [interleukin-6 (IL-6), tumor necrosis factor-α (TNFα)] measured in a resting state, pre and post SIT. [Formula: see text] (mL.kg(-1).min(-1)) improved in HYP (+11.9%) and NORM (+9.8%), but not CON (+0.9%). Similarly TTE improved in HYP (+32.2%) and NORM (+33.0%), but not CON (+3.4%) whilst the power at the anaerobic threshold (AT; W.kg(-1)) also improved in HYP (+13.3%) and NORM (+8.0%), but not CON (-0.3%). AT (mL.kg(-1).min(-1)) improved in HYP (+9.5%), but not NORM (+5%) or CON (-0.3%). No between group change occurred in 30 s sprint performance or Hb and Hct. IL-6 increased in HYP (+17.4%) and NORM (+20.1%), but not CON (+1.2%), respectively. TNF-α increased in HYP (+10.8%) NORM (+12.9%) and CON (+3.4%). SIT in HYP and NORM increased [Formula: see text], power at AT and TTE performance in untrained individuals, improvements in AT occurred only when SIT was performed in HYP. Increases in IL-6 and TNFα reflect a training induced inflammatory response to SIT; hypoxic conditions do not exacerbate this.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA