Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Intensive Care Med Exp ; 12(1): 27, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38451347

RESUMO

BACKGROUND: Aim of this study was to evaluate feasibility and effects of individualised flow-controlled ventilation (FCV), based on compliance guided pressure settings, compared to standard of pressure-controlled ventilation (PCV) in a porcine intra-abdominal hypertension (IAH) model. The primary aim of this study was to investigate oxygenation. Secondary aims were to assess respiratory and metabolic variables and lung tissue aeration. METHODS: Pigs were randomly assigned to FCV (n = 9) and PCV (n = 9). IAH was induced by insufflation of air into the abdomen to induce IAH grades ranging from 0 to 3. At each IAH grade FCV was undertaken using compliance guided pressure settings, or PCV (n = 9) was undertaken with the positive end-expiratory pressure titrated for maximum compliance and the peak pressure set to achieve a tidal volume of 7 ml/kg. Gas exchange, ventilator settings and derived formulas were recorded at two timepoints for each grade of IAH. Lung aeration was assessed by a computed tomography scan at IAH grade 3. RESULTS: All 18 pigs (median weight 54 kg [IQR 51-67]) completed the observation period of 4 h. Oxygenation was comparable at each IAH grade, but a significantly lower minute volume was required to secure normocapnia in FCV at all IAH grades (7.6 vs. 14.4, MD - 6.8 (95% CI - 8.5 to - 5.2) l/min; p < 0.001). There was also a significant reduction of applied mechanical power being most evident at IAH grade 3 (25.9 vs. 57.6, MD - 31.7 (95% CI - 39.7 to - 23.7) J/min; p < 0.001). Analysis of Hounsfield unit distribution of the computed tomography scans revealed a significant reduction in non- (5 vs. 8, MD - 3 (95% CI - 6 to 0) %; p = 0.032) and poorly-aerated lung tissue (7 vs. 15, MD - 6 (95% CI - 13 to - 3) %, p = 0.002) for FCV. Concomitantly, normally-aerated lung tissue was significantly increased (84 vs. 76, MD 8 (95% CI 2 to 15) %; p = 0.011). CONCLUSIONS: Individualised FCV showed similar oxygenation but required a significantly lower minute volume for CO2-removal, which led to a remarkable reduction of applied mechanical power. Additionally, there was a shift from non- and poorly-aerated lung tissue to normally-aerated lung tissue in FCV compared to PCV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA