1.
Eur J Clin Invest ; 54(9): e14241, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38767226

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Próteses Valvulares Cardíacas , Falha de Prótese , Masculino , Idoso
2.
Artigo em Inglês | MEDLINE | ID: mdl-38984656

RESUMO

More than mild paravalvular leak (PVL) following transcatheter aortic valve implantation (TAVI) is associated with a twofold increase in all-cause mortality, heart failure hospitalizations, and the need for reintervention. Successfully addressing PVL in TAVIs is more challenging than in surgical valves. The arterial-arterial (A-A) rail technique emerges as a valuable strategy for post-TAVI PVL closure, enhancing success rates by enabling the effective use of lower-profile vascular plug devices. When standard approach is ineffective, generating an A-A loop for post-TAVI PVL closure is probably the most recommended strategy to ensure procedural success.

3.
Catheter Cardiovasc Interv ; 104(2): 390-400, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38736245

RESUMO

BACKGROUND: Malnutrition is associated with poor prognosis in several cardiovascular diseases; however, its role in patients with secondary mitral regurgitation (SMR) is poorly known. AIMS: To evaluate the impact of nutritional status, assessed using different scores, on clinical outcomes in patients with SMR undergoing transcatheter edge-to-edge repair (TEER) in a real-world setting. METHODS: A total of 658 patients with SMR and complete nutritional data were identified from the MIVNUT registry. Nutritional status has been assessed using controlling nutritional status index (CONUT), prognostic nutritional index (PNI), and geriatric nutritional risk index (GNRI) scores. Outcomes of interest were all-cause mortality and all-cause mortality or heart failure (HF) hospitalization. RESULTS: Any malnutrition grade was observed in 79.4%, 16.7%, and 47.9% of patients by using CONUT, PNI, and GNRI, respectively, while moderate to severe malnutrition was noted in 24.7%, 16.7%, and 25.6% of patients, respectively. At a median follow-up of 2.2 years, 212 patients (32.2%) died. Moderate-severe malnutrition was associated with a higher rate of all-cause mortality (HR: 2.46 [95% CI: 1.69-3.58], HR: 2.18 [95% CI: 1.46-3.26], HR: 1.97 [95% CI: 1.41-2.74] for CONUT, PNI, and GNRI scores, respectively). The combined secondary endpoint of all-cause mortality and HF rehospitalization occurred in 306 patients (46.5%). Patients with moderate-severe malnutrition had a higher risk of the composite endpoint (HR: 1.56 [95% CI: 1.20-2.28], HR: 1.55 [95% CI: 1.01-2.19], HR: 1.36 [95% CI: 1.02-1.80] for CONUT, PNI, and GNRI scores, respectively). After adjustment for multiple confounders, moderate-severe malnutrition remained independently associated with clinical outcomes. CONCLUSIONS: Moderate-severe malnutrition was common in patients with SMR undergoing TEER. It was independently associated with poor prognosis regardless of the different scores used.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Desnutrição , Insuficiência da Valva Mitral , Valva Mitral , Avaliação Nutricional , Estado Nutricional , Sistema de Registros , Humanos , Desnutrição/mortalidade , Desnutrição/diagnóstico , Desnutrição/fisiopatologia , Feminino , Masculino , Idoso , Fatores de Risco , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Resultado do Tratamento , Prevalência , Fatores de Tempo , Medição de Risco , Idoso de 80 Anos ou mais , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/instrumentação , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Estudos Retrospectivos
4.
Echocardiography ; 41(8): e15888, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39042643

RESUMO

BACKGROUND: Device-related thrombosis (DRT) is a common finding after left atrial appendage closure (LAAC) and is associated with worse outcomes. As women are underrepresented in clinical studies, further understanding of sex differences in DRT patients is warranted. METHODS AND RESULTS: This sub-analysis from the EUROC-DRT-registry compromises 176 patients with diagnosis of DRT after LAAC. Women, who accounted for 34.7% (61/176) of patients, were older (78.0 ± 6.7 vs. 74.9 ± 9.1 years, p = .06) with lower rates of comorbidities. While DRT was detected significantly later in women (173 ± 267 vs. 127 ± 192 days, p = .01), anticoagulation therapy was escalated similarly, mainly with initiation of novel oral anticoagulant (NOAC), vitamin K antagonist (VKA) or heparin. DRT resolution was achieved in 67.5% (27/40) of women and in 75.0% (54/72) of men (p = .40). In the remaining cases, an intensification/switch of anticoagulation was conducted in 50.% (9/18) of men and in 41.7% (5/12) of women. Final resolution was achieved in 72.5% (29/40) cases in women, and in 81.9% (59/72) cases in men (p = .24). Women were followed-up for a similar time as men (779 ± 520 vs. 908 ± 687 days, p = .51). Kaplan-Meier analysis revealed no difference in mortality rates in women (Hazard Ratio [HR]: 1.73, 95%-Confidence interval [95%-CI]: .68-4.37, p = .25) and no differences in stroke (HR: .83, 95%-CI: .30-2.32, p = .72) within 2 years after LAAC. CONCLUSION: Evaluation of risk factors and outcome revealed no differences between men and women, with DRT in women being diagnosed significantly later. Women should be monitored closely to assess for DRT formation/resolution. Treatment strategies appear to be equally effective.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Sistema de Registros , Trombose , Humanos , Feminino , Masculino , Apêndice Atrial/cirurgia , Idoso , Trombose/etiologia , Fibrilação Atrial/cirurgia , Fatores Sexuais , Anticoagulantes/uso terapêutico , Fatores de Risco , Complicações Pós-Operatórias , Dispositivo para Oclusão Septal , Resultado do Tratamento , Ecocardiografia Transesofagiana/métodos , Europa (Continente)/epidemiologia , Oclusão do Apêndice Atrial Esquerdo
5.
Curr Cardiol Rep ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39073506

RESUMO

BACKGROUND: Obesity paradox in cardiovascular risk prediction has gained increasing attention in recent years. We aimed to investigate the impact of BMI on mortality following transcatheter aortic valve replacement (TAVR). METHODS: We performed a multi-center retrospective analysis of patients with severe aortic stenosis undergoing TAVR. Patients were categorized into: Underweight (BMI < 18.5), normal weight (18.5 ≤ BMI < 25), overweight (25 ≤ BMI < 30) and obese (BMI ≥ 30). Multivariate cox-proportional hazard model was used to compare all-cause mortality. RESULTS: Total of 6688 patients included (175 underweight, 2252 normal weight, 2368 overweight and 1893 with obesity). Mean age of patients was 81 ± 8 years with 55% males. Patients with obesity had higher prevalence of comorbidities but a lower overall STS score. Mortality at 30-days post-TAVR was lower in the obese population compared to underweight, normal weight, and overweight patients (1.6% vs. 6.9%, 3.6%, and 2.8%, respectively, p < 0.001). Similarly, 3-year mortality was lowest in patients with obesity (17.1% vs. 28.9%, 24.5% and 18.6%, respectively, p < 0.001). On multivariate analysis, long term all-cause mortality at 3-years remained significantly lower in patients with obesity compared to underweight (HR 1.74, 95% CI: 1.30-2.40, p < 0.001) and normal weight (HR: 1.41, 95% CI:1.21-1.63, p < 0.001) but not in overweight patients (HR: 1.10, 95% CI:0.94-1.28, p = 0.240). CONCLUSION: In conclusion, patients with obesity have improved short and long term mortality following TAVR with an observed progressive increase in mortality with lower BMI ranges.

6.
Struct Heart ; 8(2): 100262, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481716

RESUMO

Background: It is unknown whether bioprostheses used for transcatheter aortic valve implantation will have similar long-term durability as those used for surgical aortic valve replacement. Repetitive mechanical stress applied to the valve leaflets, particularly during diastole, is the main determinant of structural valve deterioration. Leaflet mechanical stress cannot be measured in vivo. The objective of this in vitro/in silico study was thus to compare the magnitude and regional distribution of leaflet mechanical stress in old vs new generations of self-expanding (SE) vs balloon expandable (BE) transcatheter heart valves (THVs). Methods: A double activation simulator was used for in vitro testing of two generations of SE THV (Medtronic CoreValve 26 mm and EVOLUT PRO 26 mm) and two generations of BE THV (Edwards SAPIEN 23 mm vs SAPIEN-3 23 mm). These THVs were implanted within a 21-mm aortic annulus. A noncontact system based on stereophotogammetry and digital image correlation with high spatial and temporal resolution (2000 img/sec) was used to visualize the valve leaflet motion and perform the three-dimensional analysis. A finite element model of the valve was developed, and the leaflet deformation obtained from the digital image correlation analysis was applied to the finite element model to calculate local leaflet mechanical stress during diastole. Results: The maximum von Mises leaflet stress was higher in early vs new THV generation (p < 0.05) and in BE vs SE THV (p < 0.05): early generation BE: 2.48 vs SE: 1.40 MPa; new generation BE: 1.68 vs SE: 1.07 MPa. For both types of THV, the highest values of leaflet stress were primarily observed in the upper leaflet edge near the commissures and to a lesser extent in the mid-portion of the leaflet body, which is the area where structural leaflet deterioration most often occurs in vivo. Conclusions: The results of this in vitro/in silico study suggest that: i) Newer generations of THVs have ∼30% lower leaflet mechanical stress than the early generations; ii) For a given generation, SE THVs have lower leaflet mechanical stress than BE THVs. Further studies are needed to determine if these differences between new vs early THV generations and between SE vs BE THVs will translate into significant differences in long-term valve durability in vivo.

7.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726722

RESUMO

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Eletrocardiografia Ambulatorial , Substituição da Valva Aórtica Transcateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Eletrocardiografia Ambulatorial/métodos , Fatores de Risco , Resultado do Tratamento
8.
EuroIntervention ; 20(16): 972-986, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39155752

RESUMO

Percutaneous transcatheter structural heart interventions have considerably expanded within the last two decades, improving clinical outcomes and quality of life versus guideline-directed medical therapy for patients frequently ineligible for surgical treatment. Transcatheter structural heart interventions comprise valve implantation or repair and also occlusions of the patent foramen ovale, atrial septal defects and left atrial appendage. These procedures expose structural devices to arterial or venous blood flow with various rheological conditions leading to potential thrombotic complications and embolisation. Furthermore, these procedures may concern comorbid patients at high risk of both ischaemic and bleeding complications. This state-of-the-art review provides a description of the device-related thrombotic risk associated with these transcatheter structural heart interventions and of the current evidence-based guidelines regarding antithrombotic treatments. Gaps in evidence for each of the studied transcatheter interventions and the main ongoing trials are also summarised.


Assuntos
Cateterismo Cardíaco , Fibrinolíticos , Humanos , Fibrinolíticos/uso terapêutico , Fibrinolíticos/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Trombose/prevenção & controle , Trombose/etiologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento
9.
J Invasive Cardiol ; 36(8)2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38489568

RESUMO

OBJECTIVES: Little is known about valve hemodynamic performance during the Evolut and Neo deployment course. We aimed to evaluate transvalvular mean and peak-to-peak gradients over several intraprocedural timepoints during TAVR with Evolut PRO+ (Medtronic) and Neo (Boston Scientific) systems. METHODS: This was single-center pilot sub-study from the SavvyWire EFficacy and SafEty in Transcatheter Aortic Valve Implantation Procedures (SAFE-TAVI) trial. Participants received either the Evolut PRO+ or Neo for native valve severe aortic stenosis and the SavvyWire (OpSens Medical) was used for device delivery, pacing, and continuous left ventricular and aortic pressure measurements. For the Evolut, evaluation was done for baseline, two-thirds of valve deployment (still recapturable), 90% of valve deployment (no longer recapturable), and post-deployment hemodynamics. For the Neo, analysis was done at baseline, after the first step (top-crown deployment), and at final status. RESULTS: Nineteen patients were included (Evolut = 15; Neo = 4). There were no statistically significant changes in peak-to-peak gradients (44 mm Hg [IQR:33-69] vs 43 mm Hg [IQR:26-62], P = .41) between baseline and two-thirds of valve deployment in the Evolut patients. There was a significant decrease in mean (40 mm Hg [IQR:32-54] vs 14 mm Hg [IQR:10-18], P less than .001) and peak-to-peak (43 mmHg [IQRS:26-62] vs 9 mm Hg [IQR:8-13], P less than .001) transvalvular gradients between two-thirds and 90% of valve deployment for Evolut. Neo patients exhibited a decrease in transvalvular gradients after top-crown deployment (42.5 mm Hg baseline vs 13 mm Hg). CONCLUSIONS: Transvalvular gradients did not vary between the point of "no-recapture" compared to baseline values in patients receiving the Evolut, whereas a significant reduction in transvalvular gradients was observed when the valve was deployed at 90% and fully deployed. The Neo valve was slightly obstructive after the first step of deployment.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Masculino , Feminino , Hemodinâmica/fisiologia , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Idoso de 80 Anos ou mais , Resultado do Tratamento , Projetos Piloto , Idoso , Seguimentos
10.
J Invasive Cardiol ; 36(2)2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38335504

RESUMO

OBJECTIVES: The SavvyWire(OpSens Medical) is a support wire for transcatheter aortic valve replacement (TAVR) procedures that, in addition to its dedicated left ventricle (LV) pacing capabilities, has a distal pressure sensor that measures live transvalvular hemodynamics during the procedure. We aimed to determine the safety, efficacy, and functionality of the SavvyWire during TAVR procedures in an all-comer population. METHODS: We performed a multicentric, prospective, observational, single-arm, all-comers registry of patients with symptomatic, severe aortic stenosis undergoing TAVR in 3 Canadian centers. Data were collected in a dedicated database, and pre-specified questionnaires were fulfilled by the heart team implanters after each procedure. RESULTS: A total of 60 patients were included (mean age: 78.6 ± 7.2 years; 51% women; mean Society of Thoracic Surgeons score: 2.2 ± 1.6%). TAVR was performed through a transfemoral approach in 90% of cases, and balloon- and self-expandable valves were used in 73% and 27% of patients, respectively. There were no cases of LV perforation, guidewire deformation, significant loss of capture, or major software malfunction. The rate of successful delivery of the TAVR system was 100%, and effective LV pacing was achieved in 98% of patients. The pre-TAVR mean gradient was 39 ± 14 mm Hg while the final post-TAVR gradient was 8 ± 5 mm Hg; the mean aortic systolic pressure during rapid pacing was 54 ± 12 mm Hg. In 97% of the TAVR procedures, SavvyWire's functionality was reported to be better or similar to other TAVR workhorse support wires. CONCLUSIONS: SavvyWire was safe, effective, and functional for live transvalvular hemodynamic evaluation and rapid pacing during TAVR procedures. More studies with larger sample sizes and comparison against different wires and gradient measurement methods are warranted.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Canadá , Hemodinâmica , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
11.
JACC Cardiovasc Interv ; 17(15): 1795-1807, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39142756

RESUMO

BACKGROUND: The Valve Academic Research Consortium (VARC)-3 definition for neurologic events after transcatheter aortic valve replacement (TAVR) lacks clinical validation. OBJECTIVES: This study sought to determine the incidence, predictors, and clinical impact of neurologic events following TAVR as defined by VARC-3 criteria. METHODS: This was a multicenter study including 2,924 patients with severe aortic stenosis undergoing TAVR. Based on Neurologic Academic Research Consortium (NeuroARC) classification, neurologic events were classified as NeuroARC type 1 (stroke), NeuroARC type 2 (covert central nervous system injury), and NeuroARC type 3 (transient ischemic attack and delirium). Baseline, procedural, and follow-up data were prospectively collected in a dedicated database. RESULTS: After a median follow-up of 13 (7-37) months, neurologic events occurred in 471 patients (16.1%), NeuroARC type 1, 2, and 3 in 37.4%, 4.7%, and 58.0% of cases, respectively, and the majority (58.6%) were periprocedural. Advanced age, chronic kidney disease, atrial fibrillation, major vascular complications, and in-hospital bleeding determined an increased risk of periprocedural events (P < 0.03 for all). Neurologic events occurring during the periprocedural time frame were independently associated with a substantial increase in mortality at 1 year after the intervention (HR: 1.91; 95% CI: 1.23-2.97; P = 0.004). However, although NeuroARC type 1 was associated with an increased mortality risk (IRR: 3.38; 95% CI: 2.30-5.56; P < 0.001 and IRR: 21.7; 95% CI: 9.63-49.1; P < 0.001 for ischemic and hemorrhagic stroke, respectively), the occurrence of NeuroARC type 3 events had no impact on mortality. CONCLUSIONS: Neurologic events after TAVR were associated with poorer short- and long-term survival. This correlation was related to the type of NeuroARC event defined by the VARC-3 criteria. Given the negative impact on clinical outcomes, every attempt should be made to reduce the risk of neurologic complications after TAVR.


Assuntos
Estenose da Valva Aórtica , Ataque Isquêmico Transitório , Índice de Gravidade de Doença , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Fatores de Risco , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Incidência , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Fatores de Tempo , Medição de Risco , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/mortalidade , Ataque Isquêmico Transitório/epidemiologia , Resultado do Tratamento , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Delírio/epidemiologia , Delírio/etiologia , Delírio/diagnóstico , Delírio/mortalidade , Bases de Dados Factuais , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem
12.
JACC Adv ; 3(2): 100761, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38939373

RESUMO

Background: A blood multimarker approach may be useful to enhance risk stratification in patients undergoing TAVI. Objectives: The objective of this study was to determine the prognostic value of multiple blood biomarkers in transcatheter aortic valve implantation (TAVI) patients. Methods: In this prospective study, several blood biomarkers of cardiovascular function, inflammation, and renal function were measured in 362 patients who underwent TAVI. The cohort was divided into 3 groups according to the number of elevated blood biomarkers (ie, ≥ median value for the whole cohort) for each patient before the procedure. Survival analyses were conducted to evaluate the association between blood biomarkers and risk of adverse event following TAVI. Results: During a median follow-up of 2.5 (IQR: 1.9-3.2) years, 34 (9.4%) patients were rehospitalized for heart failure, 99 (27%) patients died, and 113 (31.2%) met the composite endpoint of all-cause mortality or heart failure rehospitalization. Compared to patients with 0 to 3 elevated biomarkers (referent group), those with 4 to 7 and 8 to 9 elevated biomarkers had a higher risk of all-cause mortality (HR: 1.54 [95% CI: 0.84-2.80], P = 0.16, and HR: 2.81 [95% CI: 1.53-5.15], P < 0.001, respectively) and of the composite endpoint (HR: 1.65 [95% CI: 0.95-2.84], P = 0.07, and HR: 2.67 [95% CI: 1.52-4.70] P < 0.001, respectively). Moreover, adding the number of elevated blood biomarkers into the clinical multivariable model provided significant incremental predictive value for all-cause mortality (Net Reclassification Index = 0.71, P < 0.001). Conclusions: An increasing number of elevated blood biomarkers is associated with higher risks of adverse clinical outcomes following TAVI. The blood multimarker approach may be helpful to enhance risk stratification in TAVI patients.

13.
Am J Cardiol ; 213: 140-145, 2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38134979

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as a successful treatment option for severe aortic stenosis. However, the long-term outcomes of TAVR in nonagenarians is lacking. We aimed to examine the long-term mortality and quality of life in nonagenarians after TAVR. This is a multicenter, retrospective analysis on patients with severe aortic stenosis who underwent TAVR. Patients were divided into 2 groups: nonagenarians (age ≥90 years) and age <90 years. The Kansas City cardiomyopathy questionnaire (KCCQ) and New York Heart Association (NYHA) scores were compared before and after TAVR. All-cause mortality was compared between both groups at 30 days, 1 year, and 5 years after TAVR using the Cox proportional hazard model. A total of 6,896 patients were included, of whom 591 were nonagenarians. Nonagenarians had a higher Society of Thoracic Surgeons perioperative risk of mortality (8.1 ± 4.6% vs 5.4 ± 4.2%, p <0.001) before TAVR. Both groups were similar in KCCQ and NYHA scores at baseline. At 1 year after TAVR, there was no significant difference in improvement in the KCCQ overall score between those aged <90 years and nonagenarians (-4.76, 95% confidence interval [CI] -11.4 to 1.9, p = 0.161). Similarly, there was no statistically significant difference in improvement in NYHA class between the 2 groups at 1 year (odds ratio 1.07, 95% CI 0.85 to 1.25), p = 0.526). The unadjusted 30-day (3.2% vs 2.7%, hazard ratio 1.11, 95% CI 0.70 to 1.80, p = 0.667) and 5-year (28.0% vs 26.6%, hazard ratio 1.05, 95% CI 0.89 to 1.24, p = 0.60) all-cause mortality were similar between the 2 groups. In conclusion, this study demonstrates an excellent long-term mortality rate at 5 years after TAVR in nonagenarians, comparable to patients younger than 90 years. There is a significant and enduring improvement in functional status in nonagenarians, observed up to 1 year after TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Humanos , Qualidade de Vida , Nonagenários , Resultado do Tratamento , Estudos Retrospectivos , Valva Aórtica/cirurgia , Fatores de Risco
14.
J Invasive Cardiol ; 36(6)2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38446025

RESUMO

OBJECTIVES: Valve oversizing has been associated with reduced paravalvular leaks (PVL) and valve migration risk. However, no optimal cut-off oversizing value has been defined for the Evolut system (Medtronic). The aim of this study was to assess the relationship between the degree of oversizing and moderate-to-severe PVL and determine the optimal oversizing cut-off value. METHODS: We conducted a multicenter study that included 740 consecutive patients with multidetector computed tomography (CT) data. Valve size was selected according to manufacturer recommendations, with oversizing ranging from 10% to 30%. The primary endpoint was moderate-to-severe PVL. RESULTS: The median age was 84 years (79-87 years), with 58.4% women, and a median EuroSCORE II of 4.1% (2.4-7.3%). Moderate-to-severe PVL was observed in 7.0% of the patients. An inverse relationship was found between oversizing and both PVL (11.3%, 8.6%, 5.4%, and 2.7% for quartiles Q1 to Q4; P = .007) and the need for post-dilation (P = .016). The multivariable analysis showed an association between oversizing and PVL (OR: 0.915 for each 1%-increase, P = .002). The optimal oversizing cut-off value to predict PVL was 20%, and PVL was significantly higher in patients with oversizing less than 20% (10.5% vs.4.2%, P less than .001). There were no differences in major clinical events according to the degree of oversizing, and a higher oversizing did not translate into an increased risk of permanent pacemaker (18.4% vs18.3%, P = .976). CONCLUSIONS: In TAVR with the Evolut valve, a higher oversizing was associated with lower rates of moderate-to-severe PVL and a lower need for post-dilation, with no negative impact on procedural and early clinical outcomes. A 20% oversizing threshold could be suggested to reduce PVLs. Further prospective studies are warranted to validate optimal oversizing for this valve system.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Tomografia Computadorizada Multidetectores/métodos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento , Seguimentos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/diagnóstico
15.
ESC Heart Fail ; 2024 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-38894578

RESUMO

AIMS: In low-risk patients with severe aortic stenosis (AS), sutureless surgical aortic valve replacement (SU-SAVR) may be an alternative to transcatheter aortic valve implantation (TAVI). The risk of heart failure hospitalization (HFH) after aortic valve replacement (AVR) in this population is incompletely characterized. This study aims to investigate the incidence, predictors, and outcomes of HFH in patients undergoing SU-SAVR versus TAVI. METHODS AND RESULTS: Patients referred for AVR between 2013 and 2020 at two centres were consecutively included. The decision for SU-SAVR or TAVI was determined by a multidisciplinary Heart Team. Cox regression and competing risk analysis were conducted to assess adverse events. Of 594 patients (mean age 77.5 ± 6.4, 59.8% male), 424 underwent SU-SAVR, while 170 underwent TAVI. Following a mean follow-up of 34.1 ± 23.1 months, HFH occurred in 112 (27.8%) SU-SAVR patients and in 8 (4.8%) TAVI patients (P < 0.001). The SU-SAVR cohort exhibited higher all-cause mortality (138 [32.5%] patients compared with 30 [17.6%] in the TAVI cohort [P < 0.001]). These differences remained significant after sensitivity analyses with 1:1 propensity score matching for baseline variables. SU-SAVR with HFH was associated with increased all-cause mortality (61.6% vs. 23.1%, P < 0.001). Independent associates of HFH in SU-SAVR patients included diabetes, atrial fibrillation, chronic obstructive pulmonary disease, lower glomerular filtration rate and lower left ventricular ejection fraction. SU-SAVR patients with HFH had a 12-month LVEF of 59.4 ± 12.7. CONCLUSIONS: In low-risk AS, SU-SAVR is associated with a higher risk of HFH and all-cause mortality compared to TAVI. In patients with severe AS candidate to SU-SAVR or TAVI, TAVI may be the preferred intervention.

16.
J Soc Cardiovasc Angiogr Interv ; 3(1): 101066, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39131970

RESUMO

Background: Lack of standardization in posttranscatheter aortic valve replacement (TAVR) conduction disturbance (CD) identification and treatment may affect permanent pacemaker implantation (PPI) rates and clinical outcomes. The safety and efficacy of a standardized TAVR CD algorithm has not been analyzed. This study analyzes the Optimize PRO post-TAVR CD management algorithm with Evolut PRO/PRO+ valves. Methods: Optimize PRO is a prospective, postmarket study implementing 2 strategies to reduce pacemaker rates: TAVR with cusp overlap technique and a post-TAVR CD algorithm. The 2-hour postprocedural electrocardiogram (ECG) stratified patients to early discharge in the absence of new ECG changes or to CD algorithms for (1) ECG changes with preexisting right or left bundle branch block (LBBB), interventricular conduction delay or first-degree atrioventricular block, (2) new LBBB, or (3) high-degree atrioventricular block (HAVB). Results: The interim analysis of the CD cohort consisted of 125/400 TAVR recipients. In the CD cohort, the 30-day new PPI rate was higher (28.1% vs 1.5%; P <.001), and 60 (48%) patients were discharged with a 30-day continuous ECG monitor. At 30 days, 90% of patients discharged with a monitor did not require PPI. Clinical outcomes, including mortality, stroke, bleeding, and reintervention, were similar in patients with and without CDs. No patient experienced sudden cardiac death. Conclusions: Effective management of CDs using a standard algorithm following Evolut TAVR provides similar 30-day safety outcomes to patients without CDs who undergo routine next day discharge. The CD algorithm may provide an effective strategy to recognize arrhythmias early, improve PPI utilization, and facilitate safe monitoring of patients after discharge.

17.
Struct Heart ; 8(1): 100227, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38283572

RESUMO

Bicuspid aortic valve (BAV) is a common congenital valvular malformation, which may lead to early aortic valve disease and bicuspid-associated aortopathy. A novel BAV classification system was recently proposed to coincide with transcatheter aortic valve replacement being increasingly considered in younger patients with symptomatic BAV, with good clinical results, yet without randomized trial evidence. Procedural technique, along with clinical outcomes, have considerably improved in BAV patients compared with tricuspid aortic stenosis patients undergoing transcatheter aortic valve replacement. The present review summarizes the novel BAV classification systems and examines contemporary surgical and transcatheter approaches.

18.
JAMA Cardiol ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39110427

RESUMO

Importance: Optimal antithrombotic therapy after percutaneous left atrial appendage occlusion (LAAO) is not well established as no randomized evaluation has been performed to date. Objective: To compare the efficacy and safety of low-dose direct oral anticoagulation (low-dose DOAC) vs dual antiplatelet therapy (DAPT) for 3 months after LAAO. Design, Setting, and Participants: The ADALA (Low-Dose Direct Oral Anticoagulation vs Dual Antiplatelet Therapy After Left Atrial Appendage Occlusion) study was an investigator-initiated, multicenter, prospective, open-label, randomized clinical trial enrolling participants from June 12, 2019, to August 28, 2022 from 3 European sites. Patients who underwent successful LAAO were randomly assigned 1:1 to low-dose DOAC vs DAPT for 3 months after LAAO. The study was prematurely terminated when only 60% of the estimated sample size had been included due to lower recruitment rate than anticipated due to the COVID-19 pandemic. Interventions: The low-dose DOAC group received apixaban, 2.5 mg every 12 hours, and the DAPT group received aspirin, 100 mg per day, plus clopidogrel, 75 mg per day, for the first 3 months after LAAO. Main Outcomes and Measures: The primary end point was a composite of safety (major bleeding) and efficacy (thromboembolic events including stroke, systemic embolism, and device-related thrombosis [DRT]) within the first 3 months after successful LAAO. Secondary end points included individual components of the primary outcome and all-bleeding events. Results: A total of 90 patients (mean [SD] age, 76.6 [8.1] years; 60 male [66.7%]; mean [SD] CHADS-VASc score, 4.0 [1.5]) were included in the analysis (44 and 46 patients in the low-dose DOAC and DAPT groups, respectively). A total of 53 patients (58.8%) presented with previous major bleeding events (60 gastrointestinal [66.7%] and 16 intracranial [17.8%]). At 3 months, low-dose DOAC was associated with a reduction of the primary end point compared with DAPT (2 [4.5%] vs 10 [21.7%]; hazard ratio, 0.19; 95% CI, 0.04-0.88; P = .02). Patients in the low-dose DOAC group exhibited a lower rate of DRT (0% vs 6 [8.7%]; P = .04) and tended to have a lower incidence of major bleeding events (2 [4.6%] vs 6 [13.0%]; P = .17), with no differences in thromboembolic events such as stroke and systemic embolism between groups (none in the overall population). Conclusions and Relevance: This was a small, randomized clinical trial comparing different antithrombotic strategies after LAAO. Results show that use of low-dose DOAC for 3 months after LAAO was associated with a better balance between efficacy and safety compared with DAPT. However, the results of the study should be interpreted with caution due to the limited sample size and will need to be confirmed in future larger randomized trials. Trial Registration: ClinicalTrials.gov Identifier: NCT05632445.

19.
Artigo em Inglês | MEDLINE | ID: mdl-38936601

RESUMO

BACKGROUND: Transcarotid transcatheter aortic valve replacement (TC-TAVR) has emerged as an alternative access route for transcatheter aortic valve replacement (TAVR). However, scarce data exist on long-term outcomes following TC-TAVR. This study aimed to evaluate clinical outcomes at 5 years after TC-TAVR. METHODS: A total of 110 consecutive patients who underwent TC-TAVR were included. Baseline, procedural, and follow-up data were collected prospectively in a dedicated database. The primary endpoint was the incidence of a composite outcome of all-cause mortality, stroke, and repeat hospitalization at 5-year follow-up. Echocardiography results, New York Heart Association (NYHA) class, and quality of life (QoL) as assessed with the EuroQol visual analog scale (EQ-VAS) were examined over the 5-year follow-up. RESULTS: The median patient age was 77 years (interquartile range [IQR], 72-82.2 years), 42.3% were women, and the median Society of Thoracic Surgeons (STS) risk score was 5.02% (IQR, 3.4%-7.5%). The incidence of the composite primary endpoint was 54.5%. Death from any cause occurred in 45.6% of patients (11.9 per 100 patient-years); stroke in 8.2% (1.9 per 100 patient-years); disabling stroke in 2.7% (0.7 per 100 patient-years); and rehospitalization in 27.2%. The improvements in valve hemodynamics, NYHA class, and EQ-VAS following the procedure persisted at 5-year follow-up (P < .001). The incidence of bioprosthetic valve failure was 0.9%. CONCLUSIONS: About half of the moderate-to high-risk patients undergoing TC-TAVR survived with no major cardiovascular events at the 5-year follow-up. The yearly incidence of stroke events was low, and early improvements in valve hemodynamics, functional status, and QoL persisted at 5 years. These results suggest the long-term safety and efficacy of TC-TAVR and would support this approach as an alternative to surgery in non-transfemoral candidates.

20.
Eur J Heart Fail ; 26(4): 1078-1089, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38561314

RESUMO

AIMS: Heart failure (HF) outcomes remain poor despite optimal guideline-directed medical therapy (GDMT). We assessed safety, effectiveness, and transthoracic echocardiographic (TTE) outcomes during the 12 months after Ventura shunt implantation in the RELIEVE-HF open-label roll-in cohort. METHODS AND RESULTS: Eligibility required symptomatic HF despite optimal GDMT with ≥1 HF hospitalization in the prior year or elevated natriuretic peptides. The safety endpoint was device-related major adverse cardiovascular or neurological events at 30 days, compared to a prespecified performance goal. Effectiveness evaluations included the Kansas City Cardiomyopathy Questionnaire (KCCQ) at baseline, 1, 3, 6, and 12 months and TTE at baseline and 12 months. Overall, 97 patients were enrolled and implanted at 64 sites. Average age was 70 ± 11 years, 97% were in New York Heart Association class III, and half had left ventricular ejection fraction (LVEF) ≤40%. The safety endpoint was achieved (event rate 0%, p < 0.001). KCCQ overall summary score was improved by 12-16 points at all follow-up timepoints (all p < 0.004), with similar outcomes in patients with reduced and preserved LVEF. At 12 months, left ventricular end-systolic and end-diastolic volumes were reduced (p = 0.020 and p = 0.038, respectively), LVEF improved (p = 0.009), right ventricular end-systolic and end-diastolic areas were reduced (p = 0.001 and p = 0.030, respectively), and right ventricular fractional area change (p < 0.001) and tricuspid annular plane systolic excursion (p < 0.001) improved. CONCLUSION: Interatrial shunting with the Ventura device was safe and resulted in favourable clinical effects in patients with HF, regardless of LVEF. Improvements of left and right ventricular structure and function were consistent with reverse myocardial remodelling. These results would support the potential of this shunt device as a treatment for HF.


Assuntos
Ecocardiografia , Insuficiência Cardíaca , Volume Sistólico , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Feminino , Masculino , Idoso , Volume Sistólico/fisiologia , Ecocardiografia/métodos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS