Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ann Intern Med ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38768450

RESUMO

BACKGROUND: Real-time prediction of histologic features of small colorectal polyps may prevent resection and/or pathologic evaluation and therefore decrease colonoscopy costs. Previous studies showed that computer-aided diagnosis (CADx) was highly accurate, though it did not outperform expert endoscopists. OBJECTIVE: To assess the diagnostic performance of histologic predictions by general endoscopists before and after assistance from CADx in a real-life setting. DESIGN: Prospective, multicenter, single-group study. (ClinicalTrials.gov: NCT04437615). SETTING: 6 centers across the United States. PARTICIPANTS: 1252 consecutive patients undergoing colonoscopy and 49 general endoscopists with variable experience in real-time prediction of polyp histologic features. INTERVENTION: Real-time use of CADx during routine colonoscopy. MEASUREMENTS: The primary end points were the sensitivity and specificity of CADx-unassisted and CADx-assisted histologic predictions for adenomas measuring 5 mm or less. For clinical purposes, additional estimates according to location and confidence level were provided. RESULTS: The CADx device made a diagnosis for 2695 polyps measuring 5 mm or less (96%) in 1252 patients. There was no difference in sensitivity between the unassisted and assisted groups (90.7% vs. 90.8%; P = 0.52). Specificity was higher in the CADx-assisted group (59.5% vs. 64.7%; P < 0.001). Among all 2695 polyps measuring 5 mm or less, 88.2% and 86.1% (P < 0.001) in the CADx-assisted and unassisted groups, respectively, could be resected and discarded without pathologic evaluation. Among 743 rectosigmoid polyps measuring 5 mm or less, 49.5% and 47.9% (P < 0.001) in the CADx-assisted and unassisted groups, respectively, could be left in situ without resection. LIMITATION: Decision making based on CADx might differ outside a clinical trial. CONCLUSION: CADx assistance did not result in increased sensitivity of optical diagnosis. Despite a slight increase, the specificity of CADx-assisted diagnosis remained suboptimal. PRIMARY FUNDING SOURCE: Olympus America Corporation served as the clinical study sponsor.

2.
Gastrointest Endosc ; 97(3): 537-543.e2, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36228700

RESUMO

BACKGROUND AND AIMS: Performing a high-quality colonoscopy is critical for optimizing the adenoma detection rate (ADR). Colonoscopy withdrawal time (a surrogate measure) of ≥6 minutes is recommended; however, a threshold of a high-quality withdrawal and its impact on ADR are not known. METHODS: We examined withdrawal time (excluding polyp resection and bowel cleaning time) of subjects undergoing screening and/or surveillance colonoscopy in a prospective, multicenter, randomized controlled trial. We examined the relationship of withdrawal time in 1-minute increments on ADR and reported odds ratio (OR) with 95% confidence intervals. Linear regression analysis was performed to assess the maximal inspection time threshold that impacts the ADR. RESULTS: A total of 1142 subjects (age, 62.3 ± 8.9 years; 80.5% men) underwent screening (45.9%) or surveillance (53.6%) colonoscopy. The screening group had a median withdrawal time of 9.0 minutes (interquartile range [IQR], 3.3) with an ADR of 49.6%, whereas the surveillance group had a median withdrawal time of 9.3 minutes (IQR, 4.3) with an ADR of 63.9%. ADR correspondingly increased for a withdrawal time of 6 minutes to 13 minutes, beyond which ADR did not increase (50.4% vs 76.6%, P < .01). For every 1-minute increase in withdrawal time, there was 6% higher odds of detecting an additional subject with an adenoma (OR, 1.06; 95% confidence interval, 1.02-1.10; P = .004). CONCLUSIONS: Results from this multicenter, randomized controlled trial underscore the importance of a high-quality examination and efforts required to achieve this with an incremental yield in ADR based on withdrawal time. (Clinical trial registration number: NCT03952611.).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Neoplasias Colorretais/diagnóstico , Fatores de Tempo , Adenoma/diagnóstico , Colonoscopia/métodos , Detecção Precoce de Câncer , Pólipos do Colo/diagnóstico
3.
Environ Sci Technol ; 57(44): 16728-16742, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37898880

RESUMO

There is a long-standing appreciation among environmental engineers and scientists regarding the importance of biologically derived colloidal particles and their environmental fate. This interest has been recently renewed in considering bacteriophages and extracellular vesicles, which are each poised to offer engineers unique insights into fundamental aspects of environmental microbiology and novel approaches for engineering applications, including advances in wastewater treatment and sustainable agricultural practices. Challenges persist due to our limited understanding of interactions between these nanoscale particles with unique surface properties and their local environments. This review considers these biological particles through the lens of colloid science with attention given to their environmental impact and surface properties. We discuss methods developed for the study of inert (nonbiological) particle-particle interactions and the potential to use these to advance our understanding of the environmental fate and transport of extracellular vesicles and bacteriophages.


Assuntos
Bacteriófagos , Vesículas Extracelulares , Meio Ambiente , Coloides
4.
Environ Sci Technol ; 57(35): 13182-13192, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37606695

RESUMO

Extracellular vesicles (EVs) are membrane-bounded, nanosized particles, produced and secreted by all biological cell types. EVs are ubiquitous in the environment, operating in various roles including intercellular communication and plant immune modulation. Despite their ubiquity, the role of EV surface chemistry in determining transport has been minimally investigated. Using the zeta (ζ)-potential as a surrogate for surface charge, this work considers the deposition of EVs from the yeast, Saccharomyces cerevisiae, and two bacterial species, Staphylococcus aureus and Pseudomonas fluorescens, in well-characterized porous medium under various background conditions shown to influence the transport of other environmental colloidal particles: ionic strength and humic acid concentration. The affinity of S. cerevisiae EVs for the porous medium (glass beads) appeared to be sensitive to changes in ionic strength, as predicted by colloid stability (Derjaguin, Landau, Verwey, and Overbeek or DLVO) theory, and humic acid concentration, while P. fluorescens EVs deviated from DLVO predictions, suggesting that mechanisms other than charge stabilization may control the deposition of P. fluorescens. Calculations of attachment efficiency from these deposition studies were used to estimate EV transport using a clean-bed filtration model. Based on these calculations, EVs could be transported through such homogeneous porous media up to 15 m.


Assuntos
Vesículas Extracelulares , Saccharomyces cerevisiae , Substâncias Húmicas , Porosidade , Bactérias
5.
Clin Gastroenterol Hepatol ; 20(9): 2023-2031.e6, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34979245

RESUMO

BACKGROUND AND AIMS: Mucosal exposure devices including distal attachments such as the cuff and cap have shown variable results in improving adenoma detection rate (ADR) compared with high-definition white light colonoscopy (HDWLE). METHODS: We performed a prospective, multicenter randomized controlled trial in patients undergoing screening or surveillance colonoscopy comparing HDWLE to 2 different types of distal attachments: cuff (CF) (Endocuff Vision) or cap (CP) (Reveal). The primary outcome was ADR. Secondary outcomes included adenomas per colonoscopy, advanced adenoma and sessile serrated lesion detection rate, right-sided ADR, withdrawal time, and adverse events. Continuous variables were compared using Student's t test and categorical variables were compared using chi-square or Fisher's exact test using statistical software Stata version16. A P value <.05 was considered significant. RESULTS: A total of 1203 subjects were randomized to either HDWLE (n = 384; mean 62 years of age; 81.3% males), CF (n = 379; mean 62.7 years of age; 79.9% males) or CP (n = 379; mean age 62.1 years of age; 80.5% males). No significant differences were found among 3 groups for ADR (57.3%, 59.1%, and 55.7%; P = .6), adenomas per colonoscopy (1.4 ± 1.9, 1.6 ± 2.4, and 1.4 ± 2; P = .3), advanced adenoma (7.6%, 9.2%, and 8.2%; P = .7), sessile serrated lesion (6.8%, 6.3%, and 5.5%; P = .8), or right ADR (48.2%, 49.3%, and 46.2%; P = .7). The number of polyps per colonoscopy were significantly higher in the CF group compared with HDWLE and CP group (2.7 ± 3.4, 2.3 ± 2.5, and 2.2 ± 2.3; P = .013). In a multivariable model, after adjusting for age, sex, body mass index, withdrawal time, and Boston Bowel Preparation Scale score, there was no impact of device type on the primary outcome of ADR (P = .77). In screening patients, CF resulted in more neoplasms per colonoscopy (CF: 1.7 ± 2.6, HDWLE: 1.3 ± 1.7, and CP: 1.2 ± 1.8; P = .047) with a shorter withdrawal time. CONCLUSIONS: Results from this multicenter randomized controlled trial do not show any significant benefit of using either distal attachment devices (CF or CP) over HDWLE, at least in high-detector endoscopists. The Endocuff may have an advantage in the screening population. (ClinicalTrials.gov, Number: NCT03952611).


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Idoso , Idoso de 80 Anos ou mais , Colonoscopia , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Estudos Prospectivos
6.
J Clin Gastroenterol ; 56(3): 234-242, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33780215

RESUMO

BACKGROUND GOALS: Diet may contribute to symptoms of irritable bowel syndrome (IBS) and luminal production of putative IBS biomarkers including short-chain fatty acids (SCFAs). Study aims were to to assess relationships of habitual fiber or starch intake with fecal SCFAs in patients with IBS and healthy volunteers (HVs). STUDY: In 18 HVs and 30 patients with IBS (13 constipation-predominant [IBS-C] and 17 diarrhea-predominant [IBS-D]), habitual diet using a food frequency questionnaire; bowel functions using a validated bowel diary; and fecal SCFAs by HPLC-mass spectrometry were assessed. Associations of fiber and starch with SCFAs were analyzed using Spearman (rs) and Pearson (R) correlations. Relationships between other dietary endpoints, SCFAs, and bowel functions were explored. RESULTS: Habitual fiber or starch intakes were not significantly correlated with SCFAs or bowel functions in all participants or HVs nor with SCFAs in IBS. Starch was negatively correlated (R=-0.53; P=0.04) with complete evacuation in IBS-D. Fiber (rs=0.65; P=0.02) and starch (rs=0.56; P=0.05) were correlated with ease of passage in IBS-C. Stool form, frequency, and ease of passage were positively correlated with total SCFAs (all P<0.05), acetate (all P<0.01), propionate (all P<0.05), and butyrate (form P=0.01; ease of passage P=0.05) among all participants, but not in IBS. Complete evacuation was negatively correlated with propionate (R=-0.34; P=0.04) in all participants. Total (P=0.04) and individual SCFAs (all P<0.05) were positively correlated with stool form in HVs. CONCLUSIONS: Habitual fiber and starch intake does not influence fecal SCFAs but may influence bowel functions in IBS. Fecal SCFAs correlate with bowel functions among all participants including HVs.


Assuntos
Síndrome do Intestino Irritável , Defecação , Diarreia , Ingestão de Alimentos , Ácidos Graxos Voláteis/análise , Fezes/química , Humanos
7.
Cereb Cortex ; 31(8): 3678-3700, 2021 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-33749727

RESUMO

Despite ongoing advances in our understanding of local single-cellular and network-level activity of neuronal populations in the human brain, extraordinarily little is known about their "intermediate" microscale local circuit dynamics. Here, we utilized ultra-high-density microelectrode arrays and a rare opportunity to perform intracranial recordings across multiple cortical areas in human participants to discover three distinct classes of cortical activity that are not locked to ongoing natural brain rhythmic activity. The first included fast waveforms similar to extracellular single-unit activity. The other two types were discrete events with slower waveform dynamics and were found preferentially in upper cortical layers. These second and third types were also observed in rodents, nonhuman primates, and semi-chronic recordings from humans via laminar and Utah array microelectrodes. The rates of all three events were selectively modulated by auditory and electrical stimuli, pharmacological manipulation, and cold saline application and had small causal co-occurrences. These results suggest that the proper combination of high-resolution microelectrodes and analytic techniques can capture neuronal dynamics that lay between somatic action potentials and aggregate population activity. Understanding intermediate microscale dynamics in relation to single-cell and network dynamics may reveal important details about activity in the full cortical circuit.


Assuntos
Córtex Cerebral/fisiologia , Neurônios/fisiologia , Estimulação Acústica , Adulto , Animais , Estimulação Elétrica , Eletroencefalografia , Fenômenos Eletrofisiológicos , Epilepsia/fisiopatologia , Espaço Extracelular/fisiologia , Feminino , Humanos , Macaca mulatta , Imageamento por Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos ICR , Microeletrodos , Pessoa de Meia-Idade , Córtex Somatossensorial/fisiologia , Análise de Ondaletas , Adulto Jovem
8.
Dig Dis Sci ; 67(12): 5617-5627, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35322314

RESUMO

BACKGROUND: Approximately two-thirds of adults are genetically predisposed to decreased lactase activity after weaning, putting them at risk of lactose intolerance. However, symptoms are a poor marker of lactose maldigestion. AIMS: We assessed association between self-reported lactose intolerance and intestinal lactase, lactose intake, and the small intestinal microbiome. METHODS: Patients 18-75 years presenting for upper endoscopy were recruited prospectively. Observational study participants completed a lactose intolerance symptom questionnaire and reported lactose intake. Post-bulbar biopsies were obtained to measure lactase activity and assess the small intestinal mucosal microbiome. We compared intestinal lactase between patients with and without lactose intolerance. We assessed associations between lactose intolerance symptoms and lactase and lactose intake. We examined associations of small bowel microbial composition with self-reported lactose intolerance and symptoms. RESULTS: Among 34 patients, 23 (68%) reported lactose intolerance. Those with lactose intolerance had higher total symptom scores, more frequent bowel urgency, and more bowel movements after consuming dairy. The proportion of individuals with abnormal lactase activity did not differ by lactose intolerance status. Median lactase levels were correlated with total lactose intolerance symptom scores (p = 0.038) and frequency of bowel urgency (p = 0.012). Daily lactose intake did not differ between groups. In 19 patients, we observed significant associations of small intestinal microbiome beta diversity with stool consistency after consuming dairy (p = 0.03). CONCLUSIONS: Intestinal lactase is associated with lactose intolerance symptoms and bowel urgency in adults but does not distinguish the clinical phenotype entirely. Studying other contributing factors (microbiota, diet) may further clarify the pathophysiology of lactose intolerance.


Assuntos
Microbioma Gastrointestinal , Intolerância à Lactose , Humanos , Intolerância à Lactose/diagnóstico , Lactase/genética , Lactose , Intestinos
9.
J Shoulder Elbow Surg ; 31(5): 906-913, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35158065

RESUMO

BACKGROUND: Two popular methods used to treat distal-third clavicle fractures are the traditional hook plate and the anatomically contoured locking plate. No consensus exists on whether one method is more effective than the other. Therefore, the aim of this study was to compare the efficacy of a traditional hook plate with that of an anatomically contoured locking plate augmented with coracoclavicular fixation in the treatment of distal-third clavicle fractures. METHODS: Enrolled patients were randomly assigned to either the hook plate group (n = 13) or the locking plate group (n = 17). Follow-up assessments (clinical and radiologic) were performed at 6 and 12 months postoperatively. RESULTS: In both groups, union was achieved in 91% of cases at 6 months and 100% at 12 months. No differences in Disabilities of the Arm, Shoulder and Hand (DASH) and Constant-Murley shoulder scores were noted between the hook plate and locking plate groups at 12 months. From 6 to 12 months, DASH scores improved in the hook plate group (P = .007) and Constant-Murley shoulder scores tended to improve (P = .075). Surgical time was longer in the locking plate group than in the hook plate group (P < .001). CONCLUSION: Similar functional outcomes and union rates were achieved in both groups at 12 months postoperatively. However, the improvement in DASH scores in the hook plate group from 6 to 12 months suggests that patients treated with an anatomically contoured locking plate make a quicker recovery than patients treated with a hook plate.


Assuntos
Clavícula , Fraturas Ósseas , Placas Ósseas/efeitos adversos , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/etiologia , Fraturas Ósseas/cirurgia , Humanos , Estudos Prospectivos , Resultado do Tratamento
10.
Clin Gastroenterol Hepatol ; 19(8): 1627-1634, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32645451

RESUMO

BACKGROUND & AIMS: Clostridioides difficile infection (CDI) harms a large proportion of patients with cirrhosis. Fecal microbiota transplantation (FMT) is recommended for recurrent CDI, but its effects in patients with cirrhosis have not been established. We performed a multicenter observational study to evaluate the efficacy and safety of FMT for CDI in patients with cirrhosis. METHODS: We performed a retrospective study of 63 adults with cirrhosis (median model for end-stage liver disease score, 14.5; 24 patients with decompensated cirrhosis) who underwent FMT for CDI from January 2012 through November 2018 at 8 academic centers in the United States, Canada, and Italy. We collected data on patient demographics and characteristics of cirrhosis, CDI, and FMT from medical records and compared differences among patients with different severities of cirrhosis, and FMT successes vs failures at the 8-week follow-up evaluation. We also obtained data on adverse events (AEs) and severe AEs within 12 weeks of FMT. RESULTS: Patients underwent FMT for recurrent CDI (55 of 63; 87.3%), severe CDI (6 of 63; 9.5%), or fulminant CDI (2 of 63; 3.2%) primarily via colonoscopy (59 of 63; 93.7%) as outpatients (47 of 63; 76.8%). FMT success was achieved for 54 patients (85.7%). Among FMT failures, a higher proportion used non-CDI antibiotics at the time of FMT (44.4% vs 5.6%; P < .001), had Child-Pugh scores of B or C (100% vs 37.7%; P < .001), used probiotics (77.8% vs 24.1%; P = .003), had pseudomembranes (22.2% vs 0; P = .018), and underwent FMT as inpatients (45.5% vs 19%; P = .039), compared with FMT successes. In multivariable analysis, use of non-CDI antibiotics at the time of FMT (odds ratio, 17.43; 95% CI, 2.00-152.03; P = .01) and use of probiotics (odds ratio, 11.9; 95% CI, 1.81-78.3; P = .01) were associated with a greater risk of FMT failure. FMT-related AEs occurred in 33.3% of patients (21 of 63)-most were self-limited abdominal cramps or diarrhea. There were only 5 severe AEs that possibly were related to FMT; none involved infection or death. CONCLUSIONS: In a retrospective study, we found FMT to be safe and effective for the treatment of CDI in patients with cirrhosis.


Assuntos
Clostridioides difficile , Infecções por Clostridium , Doença Hepática Terminal , Clostridioides , Infecções por Clostridium/terapia , Transplante de Microbiota Fecal/efeitos adversos , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/terapia , Recidiva , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
11.
Environ Sci Technol ; 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-34346225

RESUMO

Silver nanoparticles (AgNPs) are well-proven antimicrobial nanomaterials, yet little is elucidated regarding the mechanism underlying cytotoxicity induced by these nanoparticles. Here, we tested the hypothesis that mitochondria are primary intracellular targets of two AgNPs and silver ions in mouse hepatocytes (AML12) cultured in glucose- and galactose-based media. AML12 cells were more sensitive to mitochondrial uncoupling when grown with galactose rather than glucose. However, 24 h treatments with 15 nm AgNPs and 6 nm GA-AgNPs (5 and 10 µg/mL) and AgNO3 (1 and 3 µg/mL), concentrations that resulted in either 10 or 30% cytotoxicity, failed to cause more toxicity to AML12 cells grown on galactose than glucose. Furthermore, colocalization analysis and subcellular Ag quantification did not show any enrichment of silver content in mitochondria in either medium. Finally, the effects of the same exposures on mitochondrial respiration were mild or undetectable, a result inconsistent with mitochondrial toxicity causing cell death. Our results suggest that neither ionic Ag nor the AgNPs that we tested specifically target mitochondria and are inconsistent with mitochondrial dysfunction being the primary cause of cell death after Ag exposure under these conditions.

12.
Clin Gastroenterol Hepatol ; 18(10): 2234-2243.e1, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31923639

RESUMO

BACKGROUND & AIMS: Fecal microbiota transplantation (FMT) is recommended for recurrent Clostridioides difficile infection (CDI). FMT cures nearly 80% of patients with severe or fulminant CDI (SFCDI) when utilized in a sequential manner. We compared outcomes of hospitalized patients before and after implementation of an FMT program for SFCDI and investigated whether the changes could be directly attributed to the FMT program. METHODS: We performed a retrospective analysis of characteristics and outcomes of patients hospitalized for SFCDI (430 hospitalizations) at a single center, from January 2009 through December 2016. We performed subgroup analyses of 199 patients with fulminant CDI and 110 patients with refractory SFCDI (no improvement after 5 or more days of maximal anti-CDI antibiotic therapy). We compared CDI-related mortality within 30 days of hospitalization, CDI-related colectomy, length of hospital stay, and readmission to the hospital within 30 days before (2009-2012) vs after (2013-2016) implementation of the inpatient FMT program. RESULTS: CDI-related mortality and colectomy were lower after implementation of the FMT program. Overall, CDI-related mortality was 10.2% before the FMT program was implemented vs 4.4% after (P = .02). For patients with fulminant CDI, CDI-related mortality was 21.3% before the FMT program was implemented vs 9.1% after (P = .015). For patients with refractory SFCDI, CDI-related mortality was 43.2% before the FMT program vs 12.1% after (P < .001). The FMT program significantly reduced CDI-related colectomy in patients with SFCDI (6.8% before vs 2.7% after; P = .041), in patients with fulminant CDI (15.7% before vs 5.5% after; P = .017), and patients with refractory SFCDI (31.8% vs 7.6%; P = .001). The effect of FMT program implementation on CDI-related mortality remained significant for patients with refractory SFCDI after we accounted for the underlying secular trend (odds ratio, 0.09 for level change; P = .023). CONCLUSIONS: An FMT program significantly decreased CDI-related mortality among patients hospitalized with refractory SFCDI.


Assuntos
Clostridioides difficile , Infecções por Clostridium , Clostridioides , Infecções por Clostridium/terapia , Transplante de Microbiota Fecal , Humanos , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
13.
Gastrointest Endosc ; 91(1): 115-120, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31299257

RESUMO

BACKGROUND AND AIMS: Devices for flattening colon folds can improve polyp detection at colonoscopy. However, there are few data on the endoscopic ring-fitted cap (EndoRings; EndoAid, Caesarea, Israel). We sought to compare adenoma detection with EndoRings with that of standard high-definition colonoscopy. METHODS: This was a single-center, randomized controlled trial of 562 patients (284 randomized to EndoRings and 278 to standard colonoscopy) at 2 outpatient endoscopy units in the Indiana University Hospital system. Adenoma detection was the primary outcome measured as adenoma detection rate (ADR) and adenomas per colonoscopy (APC). We also compared sessile serrated polyp detection rate, insertion times, withdrawal times, and ease of passage through the sigmoid colon. RESULTS: EndoRings was superior to standard colonoscopy in terms of APC (1.46 vs 1.06, P = .025), but there were no statistically significant differences in ADR or sessile serrated polyp detection rate. Mean withdrawal time (in patients with no polyps) was shorter and insertion time (all patients) was longer in the EndoRings arm by 1.8 minutes and 0.75 minutes, respectively. One provider had significantly higher detection with Endo-Rings and contributed substantially to the overall results. CONCLUSIONS: EndoRings can increase adenoma detection without a significant increase in procedure time, but the effect varies between operators. The use of EndoRings slows colonoscope insertion. (Clinical trial registration number: NCT03418662.).


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/instrumentação , Adenoma/patologia , Idoso , Neoplasias do Colo/patologia , Pólipos do Colo/patologia , Colonoscópios , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia
14.
PLoS Comput Biol ; 15(2): e1006769, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30742605

RESUMO

Electrocorticography (ECoG) is becoming more prevalent due to improvements in fabrication and recording technology as well as its ease of implantation compared to intracortical electrophysiology, larger cortical coverage, and potential advantages for use in long term chronic implantation. Given the flexibility in the design of ECoG grids, which is only increasing, it remains an open question what geometry of the electrodes is optimal for an application. Conductive polymer, PEDOT:PSS, coated microelectrodes have an advantage that they can be made very small without losing low impedance. This makes them suitable for evaluating the required granularity of ECoG recording in humans and experimental animals. We used two-dimensional (2D) micro-ECoG grids to record intra-operatively in humans and during acute implantations in mouse with separation distance between neighboring electrodes (i.e., pitch) of 0.4 mm and 0.2/0.25 mm respectively. To assess the spatial properties of the signals, we used the average correlation between electrodes as a function of the pitch. In agreement with prior studies, we find a strong frequency dependence in the spatial scale of correlation. By applying independent component analysis (ICA), we find that the spatial pattern of correlation is largely due to contributions from multiple spatially extended, time-locked sources present at any given time. Our analysis indicates the presence of spatially structured activity down to the sub-millimeter spatial scale in ECoG despite the effects of volume conduction, justifying the use of dense micro-ECoG grids.


Assuntos
Eletrocorticografia/métodos , Animais , Interfaces Cérebro-Computador , Córtex Cerebral , Condutividade Elétrica , Eletrodos Implantados , Eletroencefalografia/métodos , Fenômenos Eletrofisiológicos , Humanos , Camundongos , Microeletrodos , Polímeros , Registros
15.
BMC Neurol ; 20(1): 209, 2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-32450801

RESUMO

BACKGROUND: Concussion is the most common type of TBI, yet reliable objective measures related to these injuries and associated recovery processes remain elusive, especially in military personnel. The purpose of this study was to characterize the relationship between cytokines and recovery from acute brain injury in active duty service members. Inflammatory cytokines (IL-6, IL-10, and TNFα) were measured acutely in blood samples within 8 h following a medically diagnosed concussion and then 24 h later. METHODS: Participants (n = 94) were categorized into two groups: 1) military personnel who sustained provider-diagnosed concussion, without other major medical diagnosis (n = 45) and 2) healthy control participants in the same deployment environment who did not sustain concussion or other illness or injuries (n = 49). IL-6, IL-10, and TNFα concentrations were measured using an ultrasensitive single-molecule enzyme-linked immunosorbent assay. Differences in cytokine levels between concussed and healthy groups were evaluated at two time points (time point 1 ≤ 8 h after injury; time point 2 = 24 h following time point 1). RESULTS: At time point 1, IL-6 median (IQR) concentrations were 2.62 (3.62) in the concussed group, which was greater compared to IL-6 in the healthy control group (1.03 (0.90); U = 420.00, z = - 5.12, p < 0.001). Compared to healthy controls, the concussed group did not differ at time point 1 in IL-10 or TNFα concentrations (p's > 0.05). At time point 2, no differences were detected between concussed and healthy controls for IL-6, IL-10, or TNFα (p's > 0.05). The median difference between time points 1 and 2 were compared between the concussed and healthy control groups for IL-6, IL-10, and TNFα. Change in IL-6 across time was greater for the concussed group than healthy control (- 1.54 (3.12); U = 315.00, z = - 5.96, p < 0.001), with no differences between groups in the change of IL-10 or TNFα (p's > 0.05). CONCLUSION: Reported here is a significant elevation of IL-6 levels in concussed military personnel less than 8 h following injury. Future studies may examine acute and chronic neurological symptomology associated with inflammatory cytokine levels, distinguish individuals at high risk for developing neurological complications, and identify underlying biological pathways to mitigate inflammation and improve outcomes.


Assuntos
Concussão Encefálica , Interleucina-6/sangue , Militares/estatística & dados numéricos , Adulto , Concussão Encefálica/sangue , Concussão Encefálica/diagnóstico , Concussão Encefálica/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
16.
Gastrointest Endosc ; 90(5): 835-840.e1, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31319060

RESUMO

BACKGROUND AND AIMS: Endocuff (Arc Medical Design, Leeds, UK) and Endocuff Vision (Arc Medical Design, Leeds, UK) are effective mucosal exposure devices for improving polyp detection during colonoscopy. AmplifEYE (Medivators Inc, Minneapolis, Minn, USA) is a device that appears similar to the Endocuff devices but has received minimal clinical testing. METHODS: We performed a randomized controlled clinical trial using a noninferiority design to compare Endocuff Vision with AmplifEYE. RESULTS: The primary endpoint of adenomas per colonoscopy was similar in AmplifEYE at 1.63 (standard deviation 2.83) versus 1.51 (2.29) with Endocuff Vision (P = .535). The 95% lower confidence limit was 0.88 for ratio of means, establishing noninferiority of AmplifEYE (P = .008). There was no difference between the arms for mean insertion time, and mean inspection time (withdrawal time minus polypectomy time and time for washing and suctioning) was shorter with AmplifEYE (6.8 minutes vs 6.9 minutes, P = .042). CONCLUSIONS: AmplifEYE is noninferior to Endocuff Vision for adenoma detection. The decision on which device to use can be based on cost. Additional comparisons of AmplifEYE with Endocuff by other investigators are warranted. (Clinical trial registration number: NCT03560128.).


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Colonoscopia/instrumentação , Idoso , Detecção Precoce de Câncer , Feminino , Humanos , Mucosa Intestinal/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia
17.
Neuroimage ; 176: 454-464, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29678760

RESUMO

Electrocorticography (ECoG), electrophysiological recording from the pial surface of the brain, is a critical measurement technique for clinical neurophysiology, basic neurophysiology studies, and demonstrates great promise for the development of neural prosthetic devices for assistive applications and the treatment of neurological disorders. Recent advances in device engineering are poised to enable orders of magnitude increase in the resolution of ECoG without comprised measurement quality. This enhancement in cortical sensing enables the observation of neural dynamics from the cortical surface at the micrometer scale. While these technical capabilities may be enabling, the extent to which finer spatial scale recording enhances functionally relevant neural state inference is unclear. We examine this question by employing a high-density and low impedance 400 µm pitch microECoG (µECoG) grid to record neural activity from the human cortical surface during cognitive tasks. By applying machine learning techniques to classify task conditions from the envelope of high-frequency band (70-170Hz) neural activity collected from two study participants, we demonstrate that higher density grids can lead to more accurate binary task condition classification. When controlling for grid area and selecting task informative sub-regions of the complete grid, we observed a consistent increase in mean classification accuracy with higher grid density; in particular, 400 µm pitch grids outperforming spatially sub-sampled lower density grids up to 23%. We also introduce a modeling framework to provide intuition for how spatial properties of measurements affect the performance gap between high and low density grids. To our knowledge, this work is the first quantitative demonstration of human sub-millimeter pitch cortical surface recording yielding higher-fidelity state estimation relative to devices at the millimeter-scale, motivating the development and testing of µECoG for basic and clinical neurophysiology as well as towards the realization of high-performance neural prostheses.


Assuntos
Córtex Cerebral/fisiologia , Eletrocorticografia , Processamento de Imagem Assistida por Computador/métodos , Idioma , Aprendizado de Máquina , Modelos Teóricos , Adulto , Córtex Cerebral/diagnóstico por imagem , Eletrocorticografia/instrumentação , Eletrocorticografia/métodos , Eletrocorticografia/normas , Eletrodos Implantados , Humanos , Processamento de Imagem Assistida por Computador/normas , Microeletrodos , Lobo Temporal/diagnóstico por imagem , Lobo Temporal/fisiologia
19.
Gastrointest Endosc ; 83(1): 166-71, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25952085

RESUMO

BACKGROUND: The value of narrow-band imaging (NBI) for detecting serrated lesions is unknown. OBJECTIVE: To assess NBI for the detection of proximal colon serrated lesions. DESIGN: Randomized, controlled trial. SETTING: Two academic hospital outpatient units. PATIENTS: Eight hundred outpatients 50 years of age and older with intact colons undergoing routine screening, surveillance, or diagnostic examinations. INTERVENTIONS: Randomization to colon inspection in NBI versus white-light colonoscopy. MAIN OUTCOME MEASUREMENTS: The number of serrated lesions (sessile serrated polyps plus hyperplastic polyps) proximal to the sigmoid colon. RESULTS: The mean inspection times for the whole colon and proximal colon were the same for the NBI and white-light groups. There were 204 proximal colon lesions in the NBI group and 158 in the white light group (P = .085). Detection of conventional adenomas was comparable in the 2 groups. LIMITATIONS: Lack of blinding, endoscopic estimation of polyp location. CONCLUSION: NBI may increase the detection of proximal colon serrated lesions, but the result in this trial did not reach significance. Additional study of this issue is warranted. ( CLINICAL TRIAL REGISTRATION NUMBER: NCT01572428.).


Assuntos
Adenoma/patologia , Colo/patologia , Neoplasias do Colo/patologia , Pólipos do Colo/patologia , Colonoscopia/métodos , Imagem de Banda Estreita/métodos , Adenoma/diagnóstico , Colo Ascendente/patologia , Colo Descendente/patologia , Colo Transverso/patologia , Neoplasias do Colo/diagnóstico , Pólipos do Colo/diagnóstico , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Phys Chem Chem Phys ; 18(6): 4496-504, 2016 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-26791435

RESUMO

Surface engineering of functionalised polymer films is a rapidly expanding field of research with cross disciplinary implications and numerous applications. One method of generating functionalised polymer films is radio frequency induced plasma polymerisation which provides a substrate independent coating. However, there is currently limited understanding surrounding chemical interactions in the plasma phase and physical interactions at the plasma-surface interface, and their effect on functional group retention in the thin film. Here we investigate functionalised plasma polymer films generated from four precursors containing primary amines. Using XPS and fluorine tagging with 4-(trifluoromethyl)benzaldehyde, the primary amine content of plasma polymer films was measured as a function of applied power at constant precursor pressure. The results were then correlated with analysis of the plasma phase by mass spectrometry which showed loss of amine functionality for both neutral and ionic species. Surface interactions are also shown to decrease primary amine retention due to abstraction of hydrogen by high energy ion impacts. The stability of the plasma polymers in aqueous solution was also assessed and is shown to be precursor dependent. Increased understanding of the chemical and physical processes in the plasma phase and at the surface are therefore critical in designing improved plasma polymerisation processes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA