Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 44(5): 765-775, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27900519

RESUMO

PURPOSE: PET/CT with 68Ga-labelled prostate-specific membrane antigen (PSMA)-ligands has been proven to establish a promising imaging modality in the work-up of prostate cancer (PC) patients with biochemical relapse. Despite a high overall detection rate, the visualisation of local recurrence may be hampered by high physiologic tracer accumulation in the urinary bladder on whole body imaging, usually starting 60 min after injection. This study sought to verify whether early dynamic 68Ga-PSMA-11 (HBED-CC)PET/CT can differentiate pathologic PC-related tracer uptake from physiologic tracer accumulation in the urinary bladder. METHODS: Eighty consecutive PC patients referred to 68Ga -PSMA-11 PET/CT were included in this retrospective analysis (biochemical relapse: n = 64; primary staging: n = 8; evaluation of therapy response/restaging: n = 8). In addition to whole-body PET/CT acquisition 60 min post injection early dynamic imaging of the pelvis in the first 8 min after tracer injection was performed. SUVmax of pathologic lesions was calculated and time-activity curves were generated and compared to those of urinary bladder and areas of physiologic tracer uptake. RESULTS: A total of 55 lesions consistent with malignancy on 60 min whole body imaging exhibited also pathologic 68Ga-PSMA-11 uptake during early dynamic imaging (prostatic bed/prostate gland: n = 27; lymph nodes: n = 12; bone: n = 16). All pathologic lesions showed tracer uptake within the first 3 min, whereas urinary bladder activity was absent within the first 3 min of dynamic imaging in all patients. Suvmax was significantly higher in PC lesions in the first 6 min compared to urinary bladder accumulation (p < 0.001). In the subgroup of PC patients with biochemical relapse the detection rate of local recurrence could be increased from 20.3 to 29.7%. CONCLUSIONS: Early dynamic imaging in 68Ga-PSMA-11 PET/CT reliably enables the differentiation of pathologic tracer uptake in PC lesions from physiologic bladder accumulation. Performance of early dynamic imaging in addition to whole body imaging 60 min after tracer injection might improve the detection rate of local recurrence in PC patients with biochemical relapse referred for 68Ga-PSMA-11 PET/CT.


Assuntos
Compostos Organometálicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Transporte Biológico , Ácido Edético/análogos & derivados , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Oligopeptídeos , Compostos Organometálicos/metabolismo , Prostatectomia , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos , Fatores de Tempo , Bexiga Urinária/metabolismo
2.
Eur J Nucl Med Mol Imaging ; 44(6): 941-949, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28138747

RESUMO

PURPOSE: Prostate cancer (PC) cells typically show increased expression of prostate-specific membrane antigen (PSMA), which can be visualized by 68Ga-PSMA-11 PET/CT. The aim of this study was to assess the intensity of 68Ga-PSMA-11 uptake in the primary tumour and metastases in patients with biopsy-proven PC prior to therapy, and to determine whether a correlation exists between the primary tumour-related 68Ga-PSMA-11 accumulation and the Gleason score (GS) or prostate-specific antigen (PSA) level. METHODS: Ninety patients with transrectal ultrasound biopsy-proven PC (GS 6-10; median PSA: 9.7 ng/ml) referred for 68Ga-PSMA-11 PET/CT were retrospectively analysed. PET images were analysed visually and semiquantitatively by measuring the maximum standardized uptake value (SUVmax). The SUVmax of the primary tumour and pathologic lesions suspicious for lymphatic or distant metastases were then compared to the physiologic background activity of normal prostate tissue and gluteal muscle. The SUVmax of the primary tumour was assessed in relation to both PSA level and GS. RESULTS: Eighty-two patients (91.1%) demonstrated pathologic tracer accumulation in the primary tumour that exceeded physiologic tracer uptake in normal prostate tissue (median SUVmax: 12.5 vs. 3.9). Tumours with GS of 6, 7a (3+4) and 7b (4+3) showed significantly lower 68Ga-PSMA-11 uptake, with median SUVmax of 5.9, 8.3 and 8.2, respectively, compared to patients with GS >7 (median SUVmax: 21.2; p < 0.001). PC patients with PSA ≥10.0 ng/ml exhibited significantly higher uptake than those with PSA levels <10.0 ng/ml (median SUVmax: 17.6 versus 7.7; p < 0.001). In 24 patients (26.7%), 82 lymph nodes with pathologic tracer accumulation consistent with metastases were detected (median SUVmax: 10.6). Eleven patients (12.2%) revealed 55 pathologic osseous lesions suspicious for bone metastases (median SUVmax: 11.6). CONCLUSIONS: The GS and PSA level correlated with the intensity of tracer accumulation in the primary tumours of PC patients on 68Ga-PSMA-11 PET/CT. As PC tumours with GS 6+7 and patients with PSA values ≤10 ng/ml showed significantly lower 68Ga-PSMA-11 uptake, 68Ga-PSMA-11 PET/CT should be preferentially applied for primary staging of PC in patients with GS >7 or PSA levels ≥10 ng/ml.


Assuntos
Compostos Organometálicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Antígeno Prostático Específico/metabolismo , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Idoso de 80 Anos ou mais , Ácido Edético/análogos & derivados , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Oligopeptídeos , Neoplasias da Próstata/metabolismo , Traçadores Radioativos , Estudos Retrospectivos
3.
Eur J Nucl Med Mol Imaging ; 43(11): 2072-83, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27174220

RESUMO

Physiologically increased pancreatic uptake at the head/uncinate process is observed in more than one-third of patients after injection of one of the three (68)Ga-labelled octreotide-based peptides used for somatostatin (sst) receptor (r) imaging. There are minor differences between these (68)Ga-sstr-binding peptides in the imaging setting. On (68)Ga-sstr-imaging the physiological uptake can be diffuse or focal and usually remains stable over time. Differences in the maximal standardised uptake values (SUVmax) reported for the normal pancreas as well as for pancreatic neuroendocrine tumour (PNET) lesions may be related to several factors, including (a) differences in the peptide binding affinities as well as differences in sstr subtype expression of pancreatic α- and ß-cells, and heterogeneity / density of tumour cells, (b) differences in scanner resolution, image reconstruction techniques and acquisition protocols, (c) mostly retrospective study designs, (d) mixed patient populations, or (e) interference with medications such as treatment with long-acting sst analogues. The major limitation in most of the studies lies in the lack of histopathological confirmation of abnormal findings. There is a significant overlap between the calculated SUVmax-values for physiological pancreas and PNET-lesions of the head/uncinate process that do not favour the use of quantitative parameters in the clinical setting. Anecdotal long-term follow-up studies have even indicated that increased uptake in the head/uncinate process still can turn out to be malignant over years of follow up. SUVmax-data for the pancreatic body and tail are limited. Therefore, any visible focal tracer uptake in the pancreas must be considered as suspicious for malignancy irrespective of quantitative parameters. In general, sstr-PET/CT has significant implications for the management of NET patients leading to a change in treatment decision in about one-third of patients. Therefore, follow-up with (68)Ga-sstr-PET/CT is mandatory in the clinical setting if uptake in the head/uncinate process is observed.


Assuntos
Radioisótopos de Gálio/farmacocinética , Tumores Neuroendócrinos/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/normas , Receptores de Somatostatina/metabolismo , Biomarcadores Tumorais/metabolismo , Medicina Baseada em Evidências , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Imagem Molecular/métodos , Tumores Neuroendócrinos/metabolismo , Tumores Neuroendócrinos/cirurgia , Octreotida/farmacocinética , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/cirurgia , Guias de Prática Clínica como Assunto , Compostos Radiofarmacêuticos/farmacocinética , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Mol Imaging Biol ; 19(5): 723-730, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28194629

RESUMO

PURPOSE: Non-invasive techniques allowing quantitative determination of the functional liver mass are of great interest for patient management in a variety of clinical settings. Recently, we presented [68Ga]DTPA-GSA to target the hepatic asialoglycoprotein receptor for this purpose. Here, we introduce [68Ga]NOTA-GSA to improve metabolic stability of the radiopharmaceutical and compare the imaging properties with [68Ga]DTPA-GSA. PROCEDURES: Labeling of the compounds was carried out at room temperature using 1.9 M sodium acetate as buffer. For quality control, thin-layer, high-performance liquid, and size exclusion chromatographies were used. Metabolic stability was studied in rat and human serums. For in vivo evaluation, Fischer rats were scanned by positron emission tomography and magnetic resonance imaging and subsequently sacrificed for biodistribution studies. Time activity curves (TACs) for heart and liver were generated and corresponding parameters (T50, T90, LHL15, HH15) were calculated. RESULTS: [68Ga]NOTA-GSA can be produced in high radiochemical yield and purity (>95 %) within 15 min. Stability studies revealed almost no metabolite formation over the 2-h observation period. Analysis of the TACs showed comparable results for most of the investigated parameters. The only significant difference was found in the T90 value, where [68Ga]NOTA-GSA showed slower uptake in comparison with 68Ga-DTPA-GSA (123 ± 10 vs. 89 ± 3 s, p < 0.01). CONCLUSIONS: [68Ga]NOTA-GSA showed a significant increase of the metabolic stability and in most organs lower background activity. However, comparison of LHL15 and HH15 indicates that the increased stability did not further improve the diagnostic value. Thus, [68Ga]NOTA-GSA and [68Ga]DTPA-GSA can be used equivalent for imaging hepatic function with positron emission tomography.


Assuntos
Complexos de Coordenação/química , Gadolínio/química , Fígado/fisiologia , Imagem Molecular/métodos , Albumina Sérica Humana/química , Animais , Complexos de Coordenação/síntese química , Humanos , Testes de Função Hepática , Masculino , Ácido Pentético/química , Ratos Endogâmicos F344 , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA