Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Am J Physiol Heart Circ Physiol ; 321(2): H294-H305, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34142884

RESUMO

The etiology of ethanol-related congenital heart defects has been the focus of much study, but most research has concentrated on cellular and molecular mechanisms. We have shown with optical coherence tomography (OCT) that ethanol exposure led to increased retrograde flow and smaller atrioventricular (AV) cushions compared with controls. Since AV cushions play a role in patterning the conduction delay at the atrioventricular junction (AVJ), this study aims to investigate whether ethanol exposure alters the AVJ conduction in early looping hearts and whether this alteration is related to the decreased cushion size. Quail embryos were exposed to a single dose of ethanol at gastrulation, and Hamburger-Hamilton stage 19-20 hearts were dissected for imaging. Cardiac conduction was measured using an optical mapping microscope and we imaged the endocardial cushions using OCT. Our results showed that, compared with controls, ethanol-exposed embryos exhibited abnormally fast AVJ conduction and reduced cushion size. However, this increased conduction velocity (CV) did not strictly correlate with decreased cushion volume and thickness. By matching the CV map to the cushion-size map along the inflow heart tube, we found that the slowest conduction location was consistently at the atrial side of the AVJ, which had the thinner cushions, not at the thickest cushion location at the ventricular side as expected. Our findings reveal regional differences in the AVJ myocardium even at this early stage in heart development. These findings reveal the early steps leading to the heterogeneity and complexity of conduction at the mature AVJ, a site where arrhythmias can be initiated.NEW & NOTEWORTHY To the best of our knowledge, this is the first study investigating the impact of ethanol exposure on the early cardiac conduction system. Our results showed that ethanol-exposed embryos exhibited abnormally fast atrioventricular conduction. In addition, our findings, in CV measurements and endocardial cushion thickness, reveal regional differences in the AVJ myocardium even at this early stage in heart development, suggesting that the differentiation and maturation at this site are complex and warrant further studies.


Assuntos
Depressores do Sistema Nervoso Central/farmacologia , Coxins Endocárdicos/efeitos dos fármacos , Etanol/farmacologia , Sistema de Condução Cardíaco/efeitos dos fármacos , Animais , Embrião não Mamífero , Coxins Endocárdicos/diagnóstico por imagem , Coxins Endocárdicos/embriologia , Gastrulação , Coração/diagnóstico por imagem , Coração/efeitos dos fármacos , Coração/embriologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/embriologia , Codorniz , Tomografia de Coerência Óptica , Imagens com Corantes Sensíveis à Voltagem
2.
Alcohol Clin Exp Res ; 45(1): 69-78, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33206417

RESUMO

BACKGROUND: Fetal alcohol spectrum disorder (FASD) is caused by prenatal alcohol exposure (PAE), the intake of ethanol (C2 H5 OH) during pregnancy. Features of FASD cover a range of structural and functional defects including congenital heart defects (CHDs). Folic acid and choline, contributors of methyl groups to one-carbon metabolism (OCM), prevent CHDs in humans. Using our avian model of FASD, we have previously reported that betaine, another methyl donor downstream of choline, prevents CHDs. The CHD preventions are substantial but incomplete. Ethanol causes oxidative stress as well as depleting methyl groups for OCM to support DNA methylation and other epigenetic alterations. To identify more compounds that can safely and effectively prevent CHDs and other effects of PAE, we tested glutathione (GSH), a compound that regulates OCM and is known as a "master antioxidant." METHODS/RESULTS: Quail embryos injected with a single dose of ethanol at gastrulation exhibited congenital defects including CHDs similar to those identified in FASD individuals. GSH injected simultaneously with ethanol not only prevented CHDs, but also improved survival and prevented other PAE-induced defects. Assays of hearts at 8 days (HH stage 34) of quail development, when the heart normally has developed 4-chambers, showed that this single dose of PAE reduced global DNA methylation. GSH supplementation concurrent with PAE normalized global DNA methylation levels. The same assays performed on quail hearts at 3 days (HH stage 19-20) of development, showed no difference in global DNA methylation between controls, ethanol-treated, GSH alone, and GSH plus ethanol-treated cohorts. CONCLUSIONS: GSH supplementation shows promise to inhibit effects of PAE by improving survival, reducing the incidence of morphological defects including CHDs, and preventing global hypomethylation of DNA in heart tissues.


Assuntos
Metilação de DNA/efeitos dos fármacos , Transtornos do Espectro Alcoólico Fetal/prevenção & controle , Glutationa/uso terapêutico , Cardiopatias Congênitas/prevenção & controle , Efeitos Tardios da Exposição Pré-Natal , Consumo de Bebidas Alcoólicas/efeitos adversos , Animais , Depressores do Sistema Nervoso Central/efeitos adversos , Avaliação Pré-Clínica de Medicamentos , Etanol/efeitos adversos , Feminino , Glutationa/farmacologia , Cardiopatias Congênitas/induzido quimicamente , Gravidez , Codorniz
3.
Opt Lett ; 42(14): 2738-2741, 2017 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-28708157

RESUMO

We demonstrate that complex decorrelation averaging can reduce the effect of multiple scattering and improve optical coherence tomography (OCT) imaging contrast. Complex decorrelation averaging calculates the product of an A-scan and the complex conjugate of a subsequent A-scan. The resultant signal is the product of the amplitudes and the phase difference. All these resulting complex signals at a particular location are then averaged. We take advantage of the fact that complex averaging, in contrast to conventional magnitude averaging, is sensitive to phase decorrelation. Sample motion that increases signal phase variance results in lower signal magnitude after complex averaging. Such motion preferentially results in a faster decorrelation of the multiple scattering signal when compared to the single scattering signal with each scattering event spreading the phase. This indicates that we may reduce multiple scattering by implementing complex decorrelation averaging to preferentially reduce the magnitude of the multiply scattered light signal in OCT images. By adjusting the time between phase-differenced A-scans, one can regulate the amount of measured decorrelation. We have performed experiments on liquid phantoms that give experimental evidence for this hypothesis. A substantial improvement in OCT image contrast using complex decorrelation averaging is demonstrated.

4.
Alcohol Clin Exp Res ; 41(11): 1917-1927, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28888041

RESUMO

BACKGROUND: Despite decades of public education about dire consequences of prenatal alcohol exposure (PAE), drinking alcohol during pregnancy remains prevalent. As high as 40% of live-born infants exposed to alcohol during gestation and diagnosed with fetal alcohol syndrome have congenital heart defects that can be life-threatening. In animal models, the methyl donor betaine, found in foods such as wheat bran, quinoa, beets, and spinach, ameliorated neurobehavioral deficits associated with PAE, but effects on heart development are unknown. METHODS: Previously, we modeled a binge drinking episode during the first trimester in avian embryos. Here, we investigated whether betaine could prevent adverse effects of alcohol on heart development. Embryos exposed to ethanol (EtOH) with and without an optimal dose of betaine (5 µM) were analyzed at late developmental stages. Cardiac morphology parameters were rapidly analyzed and quantified using optical coherence tomography. DNA methylation at early stages was detected by immunofluorescent staining for 5-methylcytosine in sections of embryos treated with EtOH or cotreated with betaine. RESULTS: Compared to EtOH-exposed embryos, betaine-supplemented embryos had higher late-stage survival rates and fewer gross head and body defects than seen after alcohol exposure alone. Betaine also reduced the incidence of late-stage cardiac defects such as absent vessels, abnormal atrioventricular (AV) valves, and hypertrophic ventricles. Furthermore, betaine cotreatment brought measurements of great vessel diameters, interventricular septum thickness, and AV leaflet volumes in betaine-supplemented embryos close to control values. Early-stage 5-methycytosine staining revealed that DNA methylation levels were reduced by EtOH exposure and normalized by co-administration with betaine. CONCLUSIONS: This is the first study demonstrating efficacy of the methyl donor betaine in alleviating cardiac defects associated with PAE. These findings highlight the therapeutic potential of low-concentration betaine doses in mitigating PAE-induced birth defects and have implications for prenatal nutrition policies, especially for women who may not be responsive to folate supplementation.


Assuntos
Betaína/administração & dosagem , Etanol/toxicidade , Cardiopatias Congênitas/induzido quimicamente , Cardiopatias Congênitas/prevenção & controle , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Efeitos Tardios da Exposição Pré-Natal/prevenção & controle , Animais , Coturnix , Suplementos Nutricionais , Desenvolvimento Embrionário/efeitos dos fármacos , Desenvolvimento Embrionário/fisiologia , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Gravidez , Efeitos Tardios da Exposição Pré-Natal/diagnóstico por imagem
5.
Am J Physiol Heart Circ Physiol ; 311(5): H1150-H1159, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27542407

RESUMO

Cardiac neural crest cell (CNCC) ablation creates congenital heart defects (CHDs) that resemble those observed in many syndromes with craniofacial and cardiac consequences. The loss of CNCCs causes a variety of great vessel defects, including persistent truncus arteriosus and double-outlet right ventricle. However, because of the lack of quantitative volumetric measurements, less severe defects, such as great vessel size changes and valve defects, have not been assessed. Also poorly understood is the role of abnormal cardiac function in the progression of CNCC-related CHDs. CNCC ablation was previously reported to cause abnormal cardiac function in early cardiogenesis, before the CNCCs arrive in the outflow region of the heart. However, the affected functional parameters and how they correlate with the structural abnormalities were not fully characterized. In this study, using a CNCC-ablated quail model, we contribute quantitative phenotyping of CNCC ablation-related CHDs and investigate abnormal early cardiac function, which potentially contributes to late-stage CHDs. Optical coherence tomography was used to assay early- and late-stage embryos and hearts. In CNCC-ablated embryos at four-chambered heart stages, great vessel diameter and left atrioventricular valve leaflet volumes are reduced. Earlier, at cardiac looping stages, CNCC-ablated embryos exhibit abnormally twisted bodies, abnormal blood flow waveforms, increased retrograde flow percentage, and abnormal cardiac cushions. The phenotypes observed in this CNCC-ablation model were also strikingly similar to those found in an established avian fetal alcohol syndrome model, supporting the contribution of CNCC dysfunction to the development of alcohol-induced CHDs.


Assuntos
Comunicação Atrioventricular/embriologia , Coração/embriologia , Crista Neural/cirurgia , Animais , Aorta/anormalidades , Aorta/diagnóstico por imagem , Aorta/embriologia , Embrião não Mamífero , Comunicação Atrioventricular/diagnóstico por imagem , Transtornos do Espectro Alcoólico Fetal , Coração/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/embriologia , Valvas Cardíacas/anormalidades , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/embriologia , Terapia a Laser , Crista Neural/embriologia , Tamanho do Órgão , Fenótipo , Artéria Pulmonar/anormalidades , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/embriologia , Codorniz , Tomografia de Coerência Óptica
6.
Dev Dyn ; 244(4): 607-18, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25546089

RESUMO

BACKGROUND: The most commonly used method to analyze congenital heart defects involves serial sectioning and histology. However, this is often a time-consuming process where the quantification of cardiac defects can be difficult due to problems with accurate section registration. Here we demonstrate the advantages of using optical coherence tomography, a comparatively new and rising technology, to phenotype avian embryo hearts in a model of fetal alcohol syndrome where a binge-like quantity of alcohol/ethanol was introduced at gastrulation. RESULTS: The rapid, consistent imaging protocols allowed for the immediate identification of cardiac anomalies, including ventricular septal defects and misaligned/missing vessels. Interventricular septum thicknesses and vessel diameters for three of the five outflow arteries were also significantly reduced. Outflow and atrioventricular valves were segmented using image processing software and had significantly reduced volumes compared to controls. This is the first study to our knowledge that has 3D reconstructed the late-stage cardiac valves in precise detail to examine their morphology and dimensions. CONCLUSIONS: We believe, therefore, that optical coherence tomography, with its ability to rapidly image and quantify tiny embryonic structures in high resolution, will serve as an excellent and cost-effective preliminary screening tool for developmental biologists working with a variety of experimental/disease models.


Assuntos
Etanol/efeitos adversos , Cardiopatias Congênitas/induzido quimicamente , Coração/embriologia , Exposição Materna/efeitos adversos , Tomografia de Coerência Óptica , Animais , Coturnix , Modelos Animais de Doenças , Feminino , Transtornos do Espectro Alcoólico Fetal/patologia , Transtornos do Espectro Alcoólico Fetal/fisiopatologia , Análise de Fourier , Coração/efeitos dos fármacos , Cardiopatias Congênitas/etiologia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Fenótipo
7.
Catheter Cardiovasc Interv ; 85(4): E108-15, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25178981

RESUMO

BACKGROUND: While the current methodology for determining fibrous cap (FC) thickness of lipid plaques is based on manual measurements of arbitrary points, which could lead to high variability and decreased accuracy, it ignores the three-dimensional (3-D) morphology of coronary artery disease. OBJECTIVE: To compare, utilizing optical coherence tomography (OCT) assessments, volumetric quantification of FC, and macrophage detection using both visual assessment and automated image processing algorithms in non-culprit lesions of STEMI and stable angina pectoris (SAP) patients. METHODS: Lipid plaques were selected from 67 consecutive patients (1 artery/patient). FC was manually delineated by a computer-aided method and automatically classified into three thickness categories: FC < 65 µm (i.e., thin-cap fibroatheroma [TCFA]), 65-150 µm, and >150 µm. Minimum thickness, absolute categorical surface area, and fractional luminal area of FC were analyzed. Automated detection and quantification of macrophage was performed within the segmented FC. RESULTS: A total of 5,503 cross-sections were analyzed. STEMI patients when compared with SAP patients had more absolute categorical surface area for TCFA (0.43 ± 0.45 mm(2) vs. 0.15 ± 0.25 mm(2) ; P = 0.011), thinner minimum FC thickness (31.63 ± 17.09 µm vs. 47.27 ± 26.56 µm, P = 0.012), greater fractional luminal area for TCFA (1.65 ± 1.56% vs. 0.74 ± 1.2%, P = 0.046), and greater macrophage index (0.0217 ± 0.0081% vs. 0.0153 ± 0.0045%, respectively, P < 0.01). CONCLUSION: The novel OCT-based 3-D quantification of the FC and macrophage demonstrated thinner FC thickness and larger areas of TCFA coupled with more inflammation in non-culprit sites of STEMI compared with SAP.


Assuntos
Angina Estável/diagnóstico , Vasos Coronários/patologia , Inflamação/diagnóstico , Infarto do Miocárdio/diagnóstico , Tomografia de Coerência Óptica , Idoso , Algoritmos , Angina Estável/metabolismo , Angina Estável/patologia , Automação , Vasos Coronários/química , Feminino , Fibrose , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Inflamação/metabolismo , Inflamação/patologia , Lipídeos/análise , Macrófagos/patologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/patologia , Placa Aterosclerótica , Valor Preditivo dos Testes , Estudos Retrospectivos
8.
Birth Defects Res C Embryo Today ; 102(3): 227-50, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25220155

RESUMO

Neural crest cells play many key roles in embryonic development, as demonstrated by the abnormalities that result from their specific absence or dysfunction. Unfortunately, these key cells are particularly sensitive to abnormalities in various intrinsic and extrinsic factors, such as genetic deletions or ethanol-exposure that lead to morbidity and mortality for organisms. This review discusses the role identified for a segment of neural crest in regulating the morphogenesis of the heart and associated great vessels. The paradox is that their derivatives constitute a small proportion of cells to the cardiovascular system. Findings supporting that these cells impact early cardiac function raises the interesting possibility that they indirectly control cardiovascular development at least partially through regulating function. Making connections between insults to the neural crest, cardiac function, and morphogenesis is more approachable with technological advances. Expanding our understanding of early functional consequences could be useful in improving diagnosis and testing therapies.


Assuntos
Cardiopatias Congênitas/patologia , Crista Neural/efeitos dos fármacos , Teratogênicos/toxicidade , Animais , Modelos Animais de Doenças , Etanol/toxicidade , Feminino , Coração/efeitos dos fármacos , Coração/embriologia , Coração/fisiopatologia , Cardiopatias Congênitas/etiologia , Humanos , Morfogênese/efeitos dos fármacos , Crista Neural/citologia , Gravidez , Efeitos Tardios da Exposição Pré-Natal/etiologia , Efeitos Tardios da Exposição Pré-Natal/patologia
9.
Am J Physiol Heart Circ Physiol ; 306(3): H414-21, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24271490

RESUMO

Alcohol-induced congenital heart defects are frequently among the most life threatening and require surgical correction in newborns. The etiology of these defects, collectively known as fetal alcohol syndrome, has been the focus of much study, particularly involving cellular and molecular mechanisms. Few studies have addressed the influential role of altered cardiac function in early embryogenesis because of a lack of tools with the capability to assay tiny beating hearts. To overcome this gap in our understanding, we used optical coherence tomography (OCT), a nondestructive imaging modality capable of micrometer-scale resolution imaging, to rapidly and accurately map cardiovascular structure and hemodynamics in real time under physiological conditions. In this study, we exposed avian embryos to a single dose of alcohol/ethanol at gastrulation when the embryo is sensitive to the induction of birth defects. Late-stage hearts were analyzed using standard histological analysis with a focus on the atrio-ventricular valves. Early cardiac function was assayed using Doppler OCT, and structural analysis of the cardiac cushions was performed using OCT imaging. Our results indicated that ethanol-exposed embryos developed late-stage valvuloseptal defects. At early stages, they exhibited increased regurgitant flow and developed smaller atrio-ventricular cardiac cushions, compared with controls (uninjected and saline-injected embryos). The embryos also exhibited abnormal flexion/torsion of the body. Our evidence suggests that ethanol-induced alterations in early cardiac function have the potential to contribute to late-stage valve and septal defects, thus demonstrating that functional parameters may serve as early and sensitive gauges of cardiac normalcy and abnormalities.


Assuntos
Etanol/toxicidade , Cardiopatias Congênitas/etiologia , Coração/efeitos dos fármacos , Animais , Coturnix , Ecocardiografia Doppler , Embrião não Mamífero/efeitos dos fármacos , Etanol/farmacologia , Gastrulação , Coração/embriologia , Coração/fisiologia , Hemodinâmica , Tomografia de Coerência Óptica
10.
Opt Lett ; 39(17): 5066-9, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-25166075

RESUMO

An all-fiber optic catheter-based polarization-sensitive optical coherence tomography system is demonstrated. A novel multiplexing method was used to illuminate the sample, splitting the light from a 58.5 kHz Fourier-domain mode-locked laser such that two different polarization states, alternated in time, are generated by two semiconductor optical amplifiers. A 2.3 mm forward-view cone-scanning catheter probe was designed, fabricated, and used to acquire sample scattering intensity and phase retardation images. The system was first verified with a quarter-wave plate and then by obtaining intensity and phase retardation images of high-birefringence plastic, human skin in vivo, and untreated and thermally ablated porcine myocardium ex vivo. The system can potentially in vivo image of the cardiac wall to aid radio-frequency ablation therapy for cardiac arrhythmias.


Assuntos
Ablação por Cateter/instrumentação , Tomografia de Coerência Óptica/instrumentação , Animais , Arritmias Cardíacas/terapia , Birrefringência , Desenho de Equipamento , Humanos , Lasers , Monitorização Fisiológica/instrumentação , Fibras Ópticas , Suínos
11.
J Biomed Opt ; 29(2): 028001, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419756

RESUMO

Significance: Radiofrequency ablation (RFA) procedures for atrial fibrillation frequently fail to prevent recurrence, partially due to limitations in assessing extent of ablation. Optical spectroscopy shows promise in assessing RFA lesion formation but has not been validated in conditions resembling those in vivo. Aim: Catheter-based near-infrared spectroscopy (NIRS) was applied to porcine hearts to demonstrate that spectrally derived optical indices remain accurate in blood and at oblique incidence angles. Approach: Porcine left atria were ablated and mapped using a custom-fabricated NIRS catheter. Each atrium was mapped first in phosphate-buffered saline (PBS) then in porcine blood. Results: NIRS measurements showed little angle dependence up to 60 deg. A trained random forest model predicted lesions with a sensitivity of 81.7%, a specificity of 86.1%, and a receiver operating characteristic curve area of 0.921. Predicted lesion maps achieved a mean structural similarity index of 0.749 and a mean normalized inner product of 0.867 when comparing maps obtained in PBS and blood. Conclusions: Catheter-based NIRS can precisely detect RFA lesions on left atria submerged in blood. Optical parameters are reliable in blood and without perpendicular contact, confirming their ability to provide useful feedback during in vivo RFA procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Suínos , Espectroscopia de Luz Próxima ao Infravermelho , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia
12.
Arterioscler Thromb Vasc Biol ; 32(5): 1150-7, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22308042

RESUMO

OBJECTIVE: The goal of this study was to evaluate the feasibility of imaging the aorta of apolipoprotein E-deficient (ApoE(-/-)) mice for the detection of atherosclerosis and macrophages using optical coherence tomography (OCT) compared with histology. METHODS AND RESULTS: Atherosclerosis was induced by high-fat diet in 7-week-old ApoE(-/-) mice for 10 (n=7) and 22 (n=7) weeks. Nine-week-old ApoE(-/-) mice (n=7) fed a standard chow diet were used as controls. OCT images of a 10-mm descending aorta in situ were performed in 4 mice for each, and plaque and macrophages were determined at 0.5-mm intervals. Automated detection and quantification of macrophages were performed independently using a customized algorithm. Coregistered histological cross-sections were stained with hematoxylin-eosin, Mac-3, and von Kossa. Three mice in each group had en face OCT imaging to detect macrophages, which were compared with lipid-positive area with Sudan IV. OCT images were successfully acquired in all mice. OCT and histology were able to discriminate macrophages and plaque among the 3 groups and showed excellent correlation for (1) visual detection of plaque (r=0.98) and macrophages (r=0.93), (2) automated detection and quantification of macrophages by OCT versus Mac-3-positive area (r=0.92), and (3) en face OCT detection of macrophages versus Sudan IV-positive area (r=0.92). CONCLUSIONS: Murine intra-aortic OCT is feasible and shows excellent correlation with histology for detection of atherosclerotic plaque and macrophages.


Assuntos
Aorta Torácica/patologia , Aterosclerose/patologia , Inflamação/patologia , Tomografia de Coerência Óptica/métodos , Animais , Apolipoproteínas E/deficiência , Aterosclerose/complicações , Modelos Animais de Doenças , Inflamação/complicações , Macrófagos/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Índice de Gravidade de Doença
13.
Dev Dyn ; 241(3): 534-44, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22275053

RESUMO

BACKGROUND: The trajectory to heart defects may start in tubular and looping heart stages when detailed analysis of form and function is difficult by currently available methods. We used a novel method, Doppler optical coherence tomography (OCT), to follow changes in cardiovascular function in quail embryos during acute hypoxic stress. Chronic fetal hypoxia is a known risk factor for congenital heart diseases (CHDs). Decreased fetal heart rates during maternal obstructive sleep apnea suggest that studying fetal heart responses under acute hypoxia is warranted. RESULTS: We captured responses to hypoxia at the critical looping heart stages. Doppler OCT revealed detailed vitelline arterial pulsed Doppler waveforms. Embryos tolerated 1 hr of hypoxia (5%, 10%, or 15% O(2) ), but exhibited changes including decreased systolic and increased diastolic duration in 5 min. After 5 min, slower heart rates, arrhythmic events and an increase in retrograde blood flow were observed. These changes suggested slower filling of the heart, which was confirmed by four-dimensional Doppler imaging of the heart itself. CONCLUSIONS: Doppler OCT is well suited for rapid noninvasive screening for functional changes in avian embryos under near physiological conditions. Analysis of the accessible vitelline artery sensitively reflected changes in heart function and can be used for rapid screening. Acute hypoxia caused rapid hemodynamic changes in looping hearts and may be a concern for increased CHD risk.


Assuntos
Sistema Cardiovascular/fisiopatologia , Embrião não Mamífero/irrigação sanguínea , Embrião não Mamífero/fisiopatologia , Hipóxia Fetal/fisiopatologia , Cardiopatias Congênitas/embriologia , Hemodinâmica , Animais , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Codorniz , Tomografia de Coerência Óptica
14.
Biomed Opt Express ; 14(3): 1228-1242, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36950243

RESUMO

Radiofrequency ablation (RFA) is a minimally invasive procedure that is commonly used for the treatment of atrial fibrillation. However, it is associated with a significant risk of arrhythmia recurrence and complications owing to the lack of direct visualization of cardiac substrates and real-time feedback on ablation lesion transmurality. Within this manuscript, we present an automated deep learning framework for in vivo intracardiac optical coherence tomography (OCT) analysis of swine left atria. Our model can accurately identify cardiac substrates, monitor catheter-tissue contact stability, and assess lesion transmurality on both OCT intensity and polarization-sensitive OCT data. To the best of our knowledge, we have developed the first automatic framework for in vivo cardiac OCT analysis, which holds promise for real-time monitoring and guidance of cardiac RFA therapy..

15.
Transl Vis Sci Technol ; 12(3): 25, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36971678

RESUMO

Purpose: The purpose of this work is to determine the sensitivity of phase-decorrelation optical coherence tomography (OCT) to protein aggregation associated with cataracts in the ocular lens, as compared to OCT signal intensity. Methods: Six fresh porcine globes were held at 4°C until cold cataracts developed. As the globes were re-warmed to ambient temperature, reversing the cold cataract, each lens was imaged repeatedly using a conventional OCT system. Throughout each experiment, the internal temperature of the globe was recorded using a needle-mounted thermocouple. OCT scans were acquired, their temporal fluctuations were analyzed, and the rates of decorrelation were spatially mapped. Both decorrelation and intensity were evaluated as a function of recorded temperature. Results: Both signal decorrelation and intensity were found to change with lens temperature, a surrogate of protein aggregation. However, the relationship between signal intensity and temperature was not consistent across different samples. In contrast, the relationship between decorrelation and temperature was found to be consistent across samples. Conclusions: In this study, signal decorrelation was shown to be a more repeatable metric for quantification of crystallin protein aggregation in the ocular lens than OCT intensity-based metrics. Thus, OCT signal decorrelation measurements could enable more detailed and sensitive study of methods to prevent cataract formation. Translational Relevance: This dynamic light scattering-based approach to early cataract assessment can be implemented on existing clinical OCT systems without hardware additions, so it could quickly become part of a clinical study workflow or an indication for use for a pharmaceutical cataract intervention.


Assuntos
Catarata , Cristalino , Animais , Suínos , Tomografia de Coerência Óptica/métodos , Agregados Proteicos , Catarata/diagnóstico , Cristalino/diagnóstico por imagem
16.
Front Med Technol ; 5: 1162174, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37181098

RESUMO

Objective: A medical device must undergo rigorous regulatory processes to verify its safety and effectiveness while in use. In low-and middle-income countries like Uganda however, medical device innovators and designers face challenges around bringing a device from ideation to being market-ready. This is mainly attributed to a lack of clear regulatory procedures among other factors. In this paper, we illustrate the current landscape of investigational medical devices regulation in Uganda. Methods: Information about the different bodies involved in regulation of medical devices in Uganda was obtained online. Nine medical device teams whose devices have gone through the Ugandan regulatory system were interviewed to gain insights into their experiences with the regulatory system. Interviews focused on the challenges they faced, how they navigated them, and factors that supported their progress towards putting their devices on the market. Results: We identified different bodies that are part of the stepwise regulatory pathway of investigational medical devices in Uganda and roles played by each in the regulatory process. Experiences of the medical device teams collected showed that navigation through the regulatory system was different for each team and progress towards market readiness was fuelled by funding, simplicity of device, and mentorship. Conclusion: Medical devices regulation exists in Uganda but is characterised by a landscape that is still in development which thereby affects the progress of investigational medical devices.

17.
Biomed Opt Express ; 14(5): 1945-1958, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37206115

RESUMO

Optical coherence tomography (OCT) has been used to investigate heart development because of its capability to image both structure and function of beating embryonic hearts. Cardiac structure segmentation is a prerequisite for the quantification of embryonic heart motion and function using OCT. Since manual segmentation is time-consuming and labor-intensive, an automatic method is needed to facilitate high-throughput studies. The purpose of this study is to develop an image-processing pipeline to facilitate the segmentation of beating embryonic heart structures from a 4-D OCT dataset. Sequential OCT images were obtained at multiple planes of a beating quail embryonic heart and reassembled to a 4-D dataset using image-based retrospective gating. Multiple image volumes at different time points were selected as key-volumes, and their cardiac structures including myocardium, cardiac jelly, and lumen, were manually labeled. Registration-based data augmentation was used to synthesize additional labeled image volumes by learning transformations between key-volumes and other unlabeled volumes. The synthesized labeled images were then used to train a fully convolutional network (U-Net) for heart structure segmentation. The proposed deep learning-based pipeline achieved high segmentation accuracy with only two labeled image volumes and reduced the time cost of segmenting one 4-D OCT dataset from a week to two hours. Using this method, one could carry out cohort studies that quantify complex cardiac motion and function in developing hearts.

18.
J Med Imaging (Bellingham) ; 10(6): 061107, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37794884

RESUMO

Purpose: Retinopathy of prematurity (ROP) is a retinal vascular disease affecting premature infants that can culminate in blindness within days if not monitored and treated. A disease stage for scrutiny and administration of treatment within ROP is "plus disease" characterized by increased tortuosity and dilation of posterior retinal blood vessels. The monitoring of ROP occurs via routine imaging, typically using expensive instruments ($50 to $140 K) that are unavailable in low-resource settings at the point of care. Approach: As part of the smartphone-ROP program to enable referrals to expert physicians, fundus images are acquired using smartphone cameras and inexpensive lenses. We developed methods for artificial intelligence determination of plus disease, consisting of a preprocessing pipeline to enhance vessels and harmonize images followed by deep learning classification. A deep learning binary classifier (plus disease versus no plus disease) was developed using GoogLeNet. Results: Vessel contrast was enhanced by 90% after preprocessing as assessed by the contrast improvement index. In an image quality evaluation, preprocessed and original images were evaluated by pediatric ophthalmologists from the US and South America with years of experience diagnosing ROP and plus disease. All participating ophthalmologists agreed or strongly agreed that vessel visibility was improved with preprocessing. Using images from various smartphones, harmonized via preprocessing (e.g., vessel enhancement and size normalization) and augmented in physically reasonable ways (e.g., image rotation), we achieved an area under the ROC curve of 0.9754 for plus disease on a limited dataset. Conclusions: Promising results indicate the potential for developing algorithms and software to facilitate the usage of cell phone images for staging of plus disease.

19.
IEEE J Sel Top Quantum Electron ; 18(3): 1166-1175, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-26236147

RESUMO

Optical coherence tomography (OCT) has great potential for deciphering the role of mechanics in normal and abnormal heart development. OCT images tissue microstructure and blood flow deep into the tissue (1-2mm) at high spatiotemporal resolutions allowing unprecedented images of the developing heart. Here, we review the advancement of OCT technology to image heart development and report some of our recent findings utilizing OCT imaging under environmental control for longitudinal imaging. Precise control of the environment is absolutely required in longitudinal studies that follow the growth of the embryo or studies comparing normal versus perturbed heart development to obtain meaningful in vivo results. These types of studies are essential to tease out the influence of cardiac dynamics on molecular expression and their role in the progression of congenital heart defects.

20.
Skin Res Technol ; 18(2): 225-31, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22092854

RESUMO

BACKGROUND: Non-invasive methods are desirable for longitudinal studies examining drug efficacy and disease resolution defined as decreases in epidermal thickness in mouse models of psoriasiform skin disease. This would eliminate the need for either sacrificing animals or collecting serial skin biopsies to evaluate changes in disease progression during an individual study. The quantitation of epidermal thickness using optical coherence tomography (OCT) provides an alternative to traditional histology techniques. METHODS: Using the KC-Tie2 doxycycline-repressible psoriasiform skin disease mouse model, OCT imaging was completed on diseased back skin of adult KC-Tie2 (n = 3-4) and control (n = 3-4) mice, followed immediately by the surgical excision of the same region for histologic analyses. Animals were then treated with doxycycline to suppress transgene expression and to reverse the skin disease and additional OCT images and tissues were collected 2 and 4 weeks following. Epidermal thickness was measured using OCT and histology. RESULTS: Optical coherence tomography and histology both demonstrated that KC-Tie2 mice had significantly thicker epidermis (~4-fold; P < 0.0001) than control animals. By 2 weeks following gene repression, decreases in epidermal thickness were observed using both OCT and histology, and were sustained through 4 weeks. Correlation analyses between histology and OCT values at all time points and in all animals revealed high significance (R(2) = 0.78); with correlation being highest in KC-Tie2 mice (R(2) = 0.92) compared to control animals (R(2) = 0.16). CONCLUSION: Non-invasive OCT imaging provided similar values as those collected using standard histologic measures in thick skin of KC-Tie2 mice but became less reliable in thinner control mouse skin, possibly reflecting limitations in resolution of OCT. Future advances in resolution of OCT may improve and allow greater accuracy of epidermal thickness measurements.


Assuntos
Dermatite/patologia , Epiderme/patologia , Psoríase/patologia , Tomografia de Coerência Óptica/métodos , Animais , Antibacterianos/farmacologia , Biópsia , Doença Crônica , Dermatite/genética , Modelos Animais de Doenças , Doxiciclina/farmacologia , Expressão Gênica/efeitos dos fármacos , Queratinócitos/patologia , Estudos Longitudinais , Camundongos , Camundongos Mutantes , Psoríase/genética , Receptores Proteína Tirosina Quinases/genética , Receptor TIE-2 , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Tomografia de Coerência Óptica/normas , Transgenes/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA