1.
Radiat Meas ; 46(9): 923-928, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21949482

RESUMO

Biological dosimetry is an essential tool for estimating radiation doses received to personnel when physical dosimetry is not available or inadequate. The current preferred biodosimetry method is based on the measurement of radiation-specific dicentric chromosomes in exposed individuals' peripheral blood lymphocytes. However, this method is labour-, time- and expertise-demanding. Consequently, for mass casualty applications, strategies have been developed to increase its throughput. One such strategy is to develop validated cytogenetic biodosimetry laboratory networks, both national and international. In a previous study, the dicentric chromosome assay (DCA) was validated in our cytogenetic biodosimetry network involving five geographically dispersed laboratories. A complementary strategy to further enhance the throughput of the DCA among inter-laboratory networks is to use a triage DCA where dose assessments are made by truncating the labour-demanding and time-consuming metaphase-spread analysis to 20 to 50 metaphase spreads instead of routine 500 to 1000 metaphase spread analysis. Our laboratory network also validated this triage DCA, however, these dose estimates were made using calibration curves generated in each laboratory from the blood samples irradiated in a single laboratory. In an emergency situation, dose estimates made using pre-existing calibration curves which may vary according to radiation type and dose rate and therefore influence the assessed dose. Here, we analyze the effect of using a pre-existing calibration curve on assessed dose among our network laboratories. The dose estimates were made by analyzing 1000 metaphase spreads as well as triage quality scoring and compared to actual physical doses applied to the samples for validation. The dose estimates in the laboratory partners were in good agreement with the applied physical doses and determined to be adequate for guidance in the treatment of acute radiation syndrome.

2.
Radiat Res ; 171(1): 127-39, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19138057

RESUMO

The World Health Organization (WHO) held a consultation meeting at WHO Headquarters, Geneva, Switzerland, December 17-18, 2007, to develop the framework for a global biodosimetry network. The WHO network is envisioned to enable dose assessment using multiple methods [cytogenetics, electron paramagnetic resonance (EPR), radionuclide bioassays, etc.]; however, the initial discussion focused on the cytogenetic bioassay (i.e., metaphase-spread dicentric assay). Few regional cytogenetic biodosimetry networks have been established so far. The roles and resources available from United Nations (UN) agencies that provide international cooperation in biological dosimetry after radiological emergencies were reviewed. In addition, extensive reliance on the use of the relevant International Standards Organization (ISO) standards was emphasized. The results of a WHO survey of global cytogenetic biological dosimetry capability were reported, and while the survey indicates robust global capability, there was also a clear lack of global leadership and coordination. The expert group, which had a concentrated focus on cytogenetic biodosimetry, formulated the general scope and concept of operations for the development of a WHO global biodosimetry laboratory network for radiation emergencies (BioDoseNet). Follow-on meetings are planned to further develop technical details for this network.


Assuntos
Internacionalidade , Laboratórios/organização & administração , Liberação Nociva de Radioativos , Radiometria/métodos , Organização Mundial da Saúde , Coleta de Dados , Humanos , Laboratórios/normas , Seleção de Pacientes , Médicos , Radiometria/normas , Valores de Referência , Manejo de Espécimes
3.
Radiat Res ; 169(5): 551-60, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18439045

RESUMO

This interlaboratory comparison validates the dicentric chromosome assay for assessing radiation dose in mass casualty accidents and identifies the advantages and limitations of an international biodosimetry network. The assay's validity and accuracy were determined among five laboratories following the International Organization for Standardization guidelines. Blood samples irradiated at the Armed Forces Radiobiology Research Institute were shipped to all laboratories, which constructed individual radiation calibration curves and assessed the dose to dose-blinded samples. Each laboratory constructed a dose-effect calibration curve for the yield of dicentrics for (60)Co gamma rays in the 0 to 5-Gy range, using the maximum likelihood linear-quadratic model, Y = c + alphaD + betaD(2). For all laboratories, the estimated coefficients of the fitted curves were within the 99.7% confidence intervals (CIs), but the observed dicentric yields differed. When each laboratory assessed radiation doses to four dose-blinded blood samples by comparing the observed dicentric yield with the laboratory's own calibration curve, the estimates were accurate in all laboratories at all doses. For all laboratories, actual doses were within the 99.75% CI for the assessed dose. Across the dose range, the error in the estimated doses, compared to the physical doses, ranged from 15% underestimation to 15% overestimation.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Cromossomos Humanos/genética , Laboratórios , Incidentes com Feridos em Massa , Radiometria/métodos , Adulto , Calibragem , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Radiat Prot Dosimetry ; 124(2): 115-23, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18073230

RESUMO

The aim of biological dosimetry is to estimate the dose and the associated uncertainty to which an accident victim was exposed. This process requires the use of the maximum-likelihood method for fitting a calibration curve, a procedure that is not implemented in most statistical computer programs. Several laboratories have produced their own programs, but these are frequently not user-friendly and not available to outside users. We developed a software for fitting a linear-quadratic dose-response relationship by the method of maximum-likelihood and for estimating a dose from the number of aberrations observed. The program called as CABAS consists of the main curve-fitting and dose estimating module and modules for calculating the dose in cases of partial body exposure, for estimating the minimum number of cells necessary to detect a given dose of radiation and for calculating the dose in the case of a protracted exposure. The program is freely available at http://www.pu.kielce.pl/ibiol/cabas.


Assuntos
Aberrações Cromossômicas/efeitos dos fármacos , Análise Citogenética/instrumentação , Análise Citogenética/normas , Radiometria/instrumentação , Radiometria/normas , Software , Algoritmos , Bioensaio/instrumentação , Bioensaio/métodos , Bioensaio/normas , Análise Citogenética/métodos , Europa (Continente) , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Int J Radiat Biol ; 93(1): 127-135, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27572921

RESUMO

PURPOSE: Reliable dose estimation is an important factor in appropriate dosimetric triage categorization of exposed individuals to support radiation emergency response. MATERIALS AND METHODS: Following work done under the EU FP7 MULTIBIODOSE and RENEB projects, formal methods for defining uncertainties on biological dose estimates are compared using simulated and real data from recent exercises. RESULTS: The results demonstrate that a Bayesian method of uncertainty assessment is the most appropriate, even in the absence of detailed prior information. The relative accuracy and relevance of techniques for calculating uncertainty and combining assay results to produce single dose and uncertainty estimates is further discussed. CONCLUSIONS: Finally, it is demonstrated that whatever uncertainty estimation method is employed, ignoring the uncertainty on fast dose assessments can have an important impact on rapid biodosimetric categorization.


Assuntos
Algoritmos , Bioensaio/métodos , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Triagem/métodos , Teorema de Bayes , Europa (Continente) , Humanos , Guias de Prática Clínica como Assunto , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Int J Radiat Biol ; 93(1): 110-117, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27547893

RESUMO

PURPOSE: To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners. MATERIALS AND METHODS: Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies. RESULTS: The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes. CONCLUSIONS: Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network.


Assuntos
Bioensaio/métodos , Análise Citogenética/métodos , Internet/organização & administração , Linfócitos/efeitos da radiação , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Europa (Continente) , Humanos , Laboratórios/estatística & dados numéricos , Linfócitos/citologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Int J Radiat Biol ; 93(1): 136-141, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27557790

RESUMO

PURPOSE: To identify and assess, among the participants in the RENEB (Realizing the European Network of Biodosimetry) project, the emergency preparedness, response capabilities and resources that can be deployed in the event of a radiological or nuclear accident/incident affecting a large number of individuals. These capabilities include available biodosimetry techniques, infrastructure, human resources (existing trained staff), financial and organizational resources (including the role of national contact points and their articulation with other stakeholders in emergency response) as well as robust quality control/assurance systems. MATERIALS AND METHODS: A survey was prepared and sent to the RENEB partners in order to acquire information about the existing, operational techniques and infrastructure in the laboratories of the different RENEB countries and to assess the capacity of response in the event of radiological or nuclear accident involving mass casualties. The survey focused on several main areas: laboratory's general information, country and staff involved in biological and physical dosimetry; retrospective assays used, the number of assays available per laboratory and other information related to biodosimetry and emergency preparedness. Following technical intercomparisons amongst RENEB members, an update of the survey was performed one year later concerning the staff and the available assays. CONCLUSIONS: The analysis of RENEB questionnaires allowed a detailed assessment of existing capacity of the RENEB network to respond to nuclear and radiological emergencies. This highlighted the key importance of international cooperation in order to guarantee an effective and timely response in the event of radiological or nuclear accidents involving a considerable number of casualties. The deployment of the scientific and technical capabilities existing within the RENEB network members seems mandatory, to help other countries with less or no capacity for biological or physical dosimetry, or countries overwhelmed in case of a radiological or nuclear accident involving a large number of individuals.


Assuntos
Pesquisa Biomédica/organização & administração , Planejamento em Desastres/organização & administração , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Liberação Nociva de Radioativos , Gestão da Segurança/organização & administração , Europa (Continente) , Modelos Organizacionais , Radiobiologia/organização & administração
8.
Int J Radiat Biol ; 93(1): 2-14, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27707245

RESUMO

PURPOSE: A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. RESULTS: The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. CONCLUSIONS: RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/organização & administração , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Gestão da Segurança/organização & administração , Emergências , Europa (Continente) , Humanos , Objetivos Organizacionais , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Liberação Nociva de Radioativos/prevenção & controle
9.
Int J Radiat Biol ; 93(1): 20-29, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27766931

RESUMO

PURPOSE: Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. MATERIALS AND METHODS: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. RESULTS: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. CONCLUSIONS: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Humanos , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Radiat Prot Dosimetry ; 172(1-3): 192-200, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27412509

RESUMO

The BioDoseNet was founded by the World Health Organization as a global network of biodosimetry laboratories for building biodosimetry laboratory capacities in countries. The newly established BioDoseNet image repository is a databank of ~25 000 electronically captured images of metaphases from the dicentric assay, which have been previously analysed by international experts. The detailed scoring results and dose estimations have, in most cases, already been published. The compilation of these images into one image repository provides a valuable tool for training and research purposes in biological dosimetry. No special software is needed to view and score the image galleries. For those new to the dicentric assay, the BioDoseNet Image Repository provides an introduction to and training for the dicentric assay. It is an excellent instrument for intra-laboratory training purposes or inter-comparisons between laboratories, as recommended by the International Organization for Standardisation standards. In the event of a radiation accident, the repository can also increase the surge capacity and reduce the turnaround time for dose estimations. Finally, it provides a mechanism for the discussion of scoring discrepancies in difficult cases.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Análise Citogenética/métodos , Bases de Dados Factuais , Internet , Microscopia/métodos , Radiometria/métodos , Sistemas de Gerenciamento de Base de Dados , Humanos , Doses de Radiação
11.
Radiat Prot Dosimetry ; 164(1-2): 57-64, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25527180

RESUMO

In 1983, a young man inhaled accidentally a large amount of plutonium and americium. This case was carefully followed until 2013. Since no decorporation measures had been taken, the undisturbed metabolism of Pu and Am can be derived from the data. First objective was to determine the amount of inhaled radionuclides and to estimate committed effective dose. In vivo and excretion measurements started immediately after the inhalation, and for quality assurance, all types of measurements were performed by different labs in Europe and the USA. After dose assessment by various international groups were completed, the measurements were continued to produce scientific data for model validation. The data have been analysed here to estimate lung absorption parameter values for the inhaled plutonium and americium oxide using the proposed new ICRP Human Respiratory Tract Model. As supplement to the biokinetic modelling, biological data from three different cytogenetic markers have been added. The estimated committed effective dose is in the order of 1 Sv. The subject is 30 y after the inhalation, of good health, according to a recent medical check-up.


Assuntos
Poluentes Radioativos do Ar/farmacocinética , Amerício/farmacocinética , Plutônio/farmacocinética , Contagem Corporal Total/métodos , Administração por Inalação , Adulto , Carga Corporal (Radioterapia) , Simulação por Computador , Seguimentos , Humanos , Estudos Longitudinais , Modelos Biológicos , Doses de Radiação
12.
Radiat Prot Dosimetry ; 164(1-2): 165-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25274532

RESUMO

In the event of a large-scale radiological emergency, the triage of individuals according to their degree of exposure forms an important initial step of the accident management. Although clinical signs and symptoms of a serious exposure may be used for radiological triage, they are not necessarily radiation specific and can lead to a false diagnosis. Biodosimetry is a method based on the analysis of radiation-induced changes in cells of the human body or in portable electronic devices and enables the unequivocal identification of exposed people who should receive medical treatment. The MULTIBIODOSE (MBD) consortium developed and validated several biodosimetric assays and adapted and tested them as tools for biological dose assessment in a mass-casualty event. Different biodosimetric assays were validated against the 'gold standard' of biological dosimetry-the dicentric assay. The assays were harmonised in such a way that, in an emergency situation, they can be run in parallel in a network of European laboratories. The aim of this guidance is to give a concise overview of the developed biodosimetric tools as well as how and when they can be used in an emergency situation.


Assuntos
Bioensaio/normas , Exposição à Radiação/análise , Lesões por Radiação/diagnóstico , Monitoramento de Radiação/normas , Liberação Nociva de Radioativos , Triagem/métodos , Emergências , Europa (Continente) , Guias como Assunto , Humanos , Doses de Radiação , Lesões por Radiação/prevenção & controle
13.
Health Phys ; 107(1): 83-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24849907

RESUMO

In this note, the authors describe the MULTIBIODOSE software, which has been created as part of the MULTIBIODOSE project. The software enables doses estimated by networks of laboratories, using up to five retrospective (biological and physical) assays, to be combined to give a single estimate of triage category for each individual potentially exposed to ionizing radiation in a large scale radiation accident or incident. The MULTIBIODOSE software has been created in Java. The usage of the software is based on the MULTIBIODOSE Guidance: the program creates a link to a single SQLite database for each incident, and the database is administered by the lead laboratory. The software has been tested with Java runtime environment 6 and 7 on a number of different Windows, Mac, and Linux systems, using data from a recent intercomparison exercise. The Java program MULTIBIODOSE_1.0.jar is freely available to download from http://www.multibiodose.eu/software or by contacting the software administrator: MULTIBIODOSE-software@gmx.com.


Assuntos
Doses de Radiação , Software , Triagem , Humanos , Estudos Retrospectivos
14.
Int J Radiat Biol ; 90(2): 193-202, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24289146

RESUMO

PURPOSE: The European Union's Seventh Framework Programme-funded project 'Multi-disciplinary biodosimetric tools to manage high scale radiological casualties' (MULTIBIODOSE) has developed a multiparametric approach to radiation biodosimetry, with a particular emphasis on triage of large numbers of potentially exposed individuals following accidental exposures. In November 2012, an emergency exercise took place which tested the capabilities of the MULTIBIODOSE project partners. The exercise described here had a dual purpose: Intercomparison of (i) three biodosimetric assays, and (ii) the capabilities of the seven laboratories, with regards to provision of triage status for suspected radiation exposed individuals. MATERIALS AND METHODS: Three biological dosimetry tools - the dicentric, micronucleus and gamma-H2AX (the phosphorylated form of member X of histone H2A, in response to DNA double-strand breaks) foci assays - were tested, in addition to provision of the triage status results (low exposure: < 1 Gy; medium exposure: 1-2 Gy; high exposure: > 2 Gy) by the MULTIBIODOSE software. The exercise was run in two modes: An initial triage categorisation of samples (based on the first dose estimates for each assay received from each laboratory) followed by collation of the full set of estimated doses (all the results from all modes of each assay carried out by the participating laboratories) calculated using as many modes of operation as possible of the different assays developed during the project. Simulated acute whole body and partial body exposures were included. RESULTS: The results of the initial triage categorisation and the full comparison of assays and methods within and between laboratories are presented here. CONCLUSIONS: The data demonstrate that the MULTIBIODOSE approach of applying multiparametric tools to radiation emergencies is valid and effective.


Assuntos
Radiometria , Triagem , Histonas/análise , Humanos , Laboratórios , Testes para Micronúcleos , Fatores de Tempo
15.
Int J Hyg Environ Health ; 216(5): 541-52, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23507632

RESUMO

The use of micronucleus (MN) assays in in vitro genetic toxicology testing, radiation biodosimetry and population biomonitoring to study the genotoxic impacts of environment gene-interactions has steadily increased over the past two decades. As a consequence there has been a strong interest in developing automated systems to score micronuclei, a biomarker of chromosome breakage or loss, in mammalian and human cells. This paper summarises the outcomes of a workshop on this topic, organised by the HUMN project, at the 6th International Conference on Environmental Mutagenesis in Human Populations at Doha, Qatar, 2012. The aim of this paper is to summarise the outcomes of the workshop with respect to the set objectives which were: (i) Review current developments in automation of micronucleus assays by image cytometry; (ii) define the performance characteristics of automated MN scoring using image cytometry and methods of assessment for instrument validation and quality control and (iii) discuss the design of inter-laboratory comparisons and standardisation of micronucleus assays using automated image cytometry systems. It is evident that automated scoring of micronuclei by automated image cytometry using different commercially available platforms [e.g. Metafer (MetaSystems), Pathfinder™ (IMSTAR), iCyte(®) (Compucyte)], particularly for lymphocytes, is at a mature stage of development with good agreement between visual and automated scoring across systems (correlation factors ranging from 0.58 to 0.99). However, a standardised system of validation and calibration is required to enable more reliable comparison of data across laboratories and across platforms. This review identifies recent progress, important limitations and steps that need to be taken into account to enable the successful universal implementation of automated micronucleus assays by image cytometry.


Assuntos
Automação Laboratorial , Citometria por Imagem/instrumentação , Animais , Humanos , Testes para Micronúcleos , Mutagênicos/toxicidade , Controle de Qualidade , Reprodutibilidade dos Testes
16.
Radiat Res ; 175(3): 397-404, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21388284

RESUMO

Biological dosimetry is an essential tool for estimating radiation dose. The dicentric chromosome assay (DCA) is currently the tool of choice. Because the assay is labor-intensive and time-consuming, strategies are needed to increase throughput for use in radiation mass casualty incidents. One such strategy is to truncate metaphase spread analysis for triage dose estimates by scoring 50 or fewer metaphases, compared to a routine analysis of 500 to 1000 metaphases, and to increase throughput using a large group of scorers in a biodosimetry network. Previously, the National Institutes for Allergies and Infectious Diseases (NIAID) and the Armed Forces Radiobiology Research Institute (AFRRI) sponsored a double-blinded interlaboratory comparison among five established international cytogenetic biodosimetry laboratories to determine the variability in calibration curves and in dose measurements in unknown, irradiated samples. In the present study, we further analyzed the published data from this previous study to investigate how the number of metaphase spreads influences dose prediction accuracy and how this information could be of value in the triage and management of people at risk for the acute radiation syndrome (ARS). Although, as expected, accuracy decreased with lower numbers of metaphase spreads analyzed, predicted doses by the laboratories were in good agreement and were judged to be adequate to guide diagnosis and treatment of ARS. These results demonstrate that for rapid triage, a network of cytogenetic biodosimetry laboratories can accurately assess doses even with a lower number of scored metaphases.


Assuntos
Síndrome Aguda da Radiação/diagnóstico , Síndrome Aguda da Radiação/terapia , Cromossomos Humanos/efeitos da radiação , Incidentes com Feridos em Massa , Liberação Nociva de Radioativos , Radiometria/métodos , Triagem/métodos , Síndrome Aguda da Radiação/genética , Calibragem , Relação Dose-Resposta a Droga , Humanos , Incidentes com Feridos em Massa/mortalidade , Metáfase/efeitos da radiação , Liberação Nociva de Radioativos/mortalidade
17.
Radiat Prot Dosimetry ; 138(4): 397-401, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19951985

RESUMO

In recent years, a number of events have occurred that highlight the necessity of being prepared for a possible large-scale radiological event. An important question is how well are European Union (EU) Member States prepared to cope with mass radiological casualties. A survey to establish the current status of biological dosimetry across the EU was carried out with the aim of assessing capacity to perform biodosimetric triage of accident victims. Information was sought from the radiation protection authorities of the 27 Member States plus Switzerland and Norway. Biology dosimetry is established in 15 EU countries. Their total capacity for dosimetric triage is about 1500 cases per week analysed with a dicentric assay or about 800 cases analysed with a micronucleus assay. Although these numbers appear encouraging, there is not much collaboration between the laboratories and what is required is a network at the EU level.


Assuntos
Planejamento em Desastres/organização & administração , União Europeia , Incidentes com Feridos em Massa , Monitoramento de Radiação , Liberação Nociva de Radioativos , Triagem/métodos , Bioensaio , Análise Citogenética , Humanos , Testes para Micronúcleos , Lesões por Radiação
18.
Int J Radiat Biol ; 86(1): 2-11, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20070210

RESUMO

PURPOSE: In case of a large-scale radiation accident when hundreds of people may be exposed, it is important to distinguish the severely exposed individuals (> or =1 gray), who require early medical treatment, from those less exposed. The aim of our study was to develop a quick population triage method based on automated micronucleus (MN) scoring. MATERIALS AND METHODS: Using the MN software module developed by MetaSystems specifically for the Metafer4 platform, about 60 blood samples can be scored in one day. Standard dose response curves were determined for manual and automated MN scoring. RESULTS: The automated MN assay results were closely correlated with MN yields obtained with the manual procedure. A dose of 1 Gy can be estimated with an uncertainty of 0.2 Gy. Corrections for false positives and false negatives by visual inspection of the image gallery did not result in an improved accuracy or reproducibility. To test the automated MN assay in a multicenter setting, an inter-laboratory comparison was performed whereby irradiated blood samples were processed in Ghent University (Belgium) and BfS (Bundesamt fuer Strahlenschutz; Germany). Both laboratories obtained comparable results. CONCLUSIONS: These results confirm the efficacy of the automated MN assay for fast population triage in a multicenter setting, in the case of large radiation accidents.


Assuntos
Testes para Micronúcleos , Liberação Nociva de Radioativos , Triagem , Adulto , Relação Dose-Resposta à Radiação , Feminino , Humanos , Indóis , Masculino , Pessoa de Meia-Idade
19.
Ann Ist Super Sanita ; 45(3): 251-9, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19861729

RESUMO

Biological dosimetry, based on the analysis of dicentric chromosomes, is an internationally established, independent method applied in the area of radiation protection. The biodosimetry is mainly performed, in addition to physical dosimetry, with the aim of individual dose assessment, especially after unclear or suspected radiation dose exposures. However, a new biodosimetrical challenge has emerged in recent years in the form of a possible large scale radiation accident potentially involving large numbers of exposed persons. In order to be prepared to act in an efficient manner in such an accident, the established cytogenetic laboratories have increased their cooperation at the national and international level. General experience and results of intercomparisons are reported and future options to increase sample throughput are outlined.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Cromossomos/efeitos da radiação , Radiometria/métodos , Células Sanguíneas/efeitos da radiação , Células Sanguíneas/ultraestrutura , Relação Dose-Resposta à Radiação , Humanos , Liberação Nociva de Radioativos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA