Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Arthroscopy ; 34(2): 513-518, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29100765

RESUMO

PURPOSE: To determine whether (1) tunnels that breach the anterior cortex of the patella result in increased fracture risk and (2) transosseous tunnels drilled across the patella significantly reduce the tensile force needed to fracture the patella. METHODS: Twenty-six fresh-frozen cadaveric human patellas were randomized to 1 of 3 groups: a control group with unmodified patellas, a group with 2 transverse tunnels (TT) that did not breach the anterior cortex, and a group with 2 TT that breached the anterior cortex of the patella (PA). Patellas were connected in series to a load cell via freeze clamp attachments to the quadriceps and patellar tendons. Pull was fixed at 45° with the patella set in the trochlear groove of a synthetic femur. Patellas were loaded cyclically, then to failure. RESULTS: Twenty-six patellas were tested (mean age = 71.4 years; range = 37-95, standard deviation [STD] = 11.5 years). PA patellas were more likely to fracture through the tunnel than TT patellas (100% vs 25%, P = .033). Control, TT, and PA groups failed at 1,915 N (STD = 508 N), 1,901 N (STD = 884 N), and 1,640 N (STD = 625 N), respectively. There was no statistically significant difference in overall load to failure between control and TT (P = .969), control and PA (P = .321), and TT and PA (P = .488) groups. CONCLUSIONS: Transosseous patellar tunnels for medial patellofemoral ligament reconstruction that breached the anterior cortex were more likely to fracture during longitudinal load than those that did not breach the anterior cortex. However, we found no statistically significant difference in the tensile load to failure between native patellas and patellas with either type of transosseous tunnel. CLINICAL RELEVANCE: The results of this study show that breaching the anterior cortex during transosseous drilling increases the risk of a patellar fracture occurring through the transosseous tunnel.


Assuntos
Fraturas Ósseas/etiologia , Ligamentos Articulares/cirurgia , Patela/lesões , Articulação Patelofemoral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Feminino , Fêmur/cirurgia , Humanos , Traumatismos do Joelho/etiologia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Ligamento Patelar/cirurgia , Complicações Pós-Operatórias , Músculo Quadríceps/cirurgia , Distribuição Aleatória , Medição de Risco/métodos , Suporte de Carga
2.
J Shoulder Elbow Surg ; 26(3): 409-415, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27745810

RESUMO

BACKGROUND: Double-strand lateral ulnar collateral ligament (LUCL) reconstruction is an effective treatment for posterolateral rotatory instability (PLRI) of the elbow, but anatomic landmarks for ulnar tunnel placement are often difficult to identify intraoperatively, which potentially can result in a nonanatomic LUCL reconstruction. This study investigated the effect of ulnar tunnel location on joint stability in double-strand LUCL reconstruction. METHODS: PLRI was artificially created in 7 cadaveric elbows, and double-strand LUCL reconstruction was performed. Five different ulnar tunnels were made along the length of the ulna. In each specimen, each possible pair of 2 tunnels (10 total) were used for graft passage. Varus and posterolateral joint gapping was measured after joint loading using a 3-dimensional digitizer system and X-ray image intensifier. RESULTS: No significant gapping was observed at the posterolateral ulnohumeral joint regardless of the location of the ulnar tunnels (P > .05). In contrast, the lateral radiocapitellar joint showed statistically significant varus gapping when both ulnar tunnels were placed proximal to the radial head-neck junction (P < .05). DISCUSSION: This findings of study suggest that the location of the ulnar tunnels may not be as critical as that of the humeral tunnel during double-strand LUCL reconstruction and that posterolateral rotatory elbow stability can be achieved reasonably well as long as at least 1 of the 2 ulnar tunnels is located at or distal to the radial head-neck junction level.


Assuntos
Pontos de Referência Anatômicos , Ligamento Colateral Ulnar/cirurgia , Lesões no Cotovelo , Instabilidade Articular/cirurgia , Adulto , Cadáver , Ligamento Colateral Ulnar/lesões , Articulação do Cotovelo/fisiologia , Articulação do Cotovelo/cirurgia , Feminino , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade
3.
J Shoulder Elbow Surg ; 25(11): 1874-1881, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27364146

RESUMO

BACKGROUND: Selecting a properly sized radial head prosthesis is imperative during radial head replacement. Although there has been much emphasis on avoiding overlengthening of the radius, little has been studied about how to avoid shortening. The purpose of this study was to characterize how a radial head replacement appears on intraoperative fluoroscopy depending on the height of the prosthetic radial head. METHODS: Articular cartilage thickness of the radial head was measured in 9 cadaveric elbows. Radial head replacement was performed in each specimen with 4 different prosthetic head heights: 4 mm and 2 mm shortening, anatomic, and 2 mm overlengthening. Anteroposterior fluoroscopic images were obtained for each head height, and the prosthetic radial head height was measured at 3 forearm positions (supination, neutral, and pronation) using the subchondral bone of the lateral edge of the coronoid at the reference point. RESULTS: The mean cartilage thickness of the radial head was 1.3 ± 0.4 mm. The prosthetic radial head appeared 2.2 ± 0.4 mm more proximal than the subchondral bone of the coronoid lateral edge in anteroposterior radiographs when the articular surface of the prosthesis was completely even with the coronoid articular surface. Unlike the native radial head, a prosthetic radial head showed a significant change of height with different forearm rotation (P < .001). DISCUSSION: This study found that a perfectly anatomic radial head replacement appears overlengthened by approximately 2 mm in intraoperative radiographs. This finding can be useful in guiding the appropriate height of a prosthetic radial head.


Assuntos
Artroplastia de Substituição do Cotovelo , Prótese de Cotovelo , Ajuste de Prótese , Rádio (Anatomia)/diagnóstico por imagem , Adulto , Cadáver , Cartilagem Articular/anatomia & histologia , Cartilagem Articular/diagnóstico por imagem , Articulação do Cotovelo/cirurgia , Feminino , Fluoroscopia , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Rádio (Anatomia)/cirurgia , Fraturas do Rádio/cirurgia
4.
J Foot Ankle Surg ; 55(6): 1175-1179, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27545512

RESUMO

Medial displacement calcaneal osteotomies have been shown to be successful in the surgical management of adult acquired flatfoot, in particular, stage 2 deformity. Classically, the medial displacement calcaneal osteotomy technique has been performed. However, a calcaneal Z osteotomy has been more recently described and applied in the surgical management of flatfoot deformity. Although the potential advantages of the calcaneal Z technique have been reported, data on its effect on the subtalar joint are lacking. A validated flatfoot model was induced in 8 cadaveric feet that had been randomly assigned to either medial displacement calcaneal osteotomy (n = 4) or calcaneal Z osteotomy (n = 4). The feet were loaded through the tibia with a constant ground reaction force of 400 N, with a simultaneous increase in the Achilles tendon force to 300 or 500 N. The subtalar joint pressures were recorded before and after osteotomy. We did not detect any statistically significant differences between the 2 techniques in terms of their effects on subtalar joint pressure.


Assuntos
Calcâneo/cirurgia , Pé Chato/cirurgia , Osteotomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Pé Chato/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Articulação Talocalcânea/fisiopatologia , Adulto Jovem
5.
Toxicol Pathol ; 41(3): 519-27, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22700648

RESUMO

Repeated bolus intravenous (IV) administration of large doses of beta-lactams and aminoglycosides has previously been associated with the development of eosinophilic and occlusive arterial lesions limited to the lungs in calves. Reviewing 13 years worth of records from left ventricular assist device implantation studies, morphologically identical segmental arterial lesions were present in 32 of the 56 calves receiving IV antibiotics, affecting lungs (6/50), kidneys (12/56), or lungs and kidneys (14/50). In 16 of these calves, renal arterial lesions spatially colocalized with renal cortical infarctions. Lesions were noted in additional abdominal organs in 4 of the 50 calves and were exclusively present in the liver in a single calf. Similar arterial lesions were also noted in the lungs (3/4), kidneys (1/4), liver (1/4), and spleen (1/4) of unimplanted calves receiving similar IV antibiotic regimens for bacterial infections. Lesions were observed with therapeutic IV doses of cephalosporins with or without aminoglycosides over shorter intervals than previously implicated. Lesions were significantly associated with increased peripheral eosinophil counts and mildly elevated, not reduced, arterial pulse pressures. This report documents the features of an idiosyncratic drug reaction with features strongly suggestive of an acute type-I hypersensitivity in this species.


Assuntos
Antibacterianos/efeitos adversos , Arterite/induzido quimicamente , Eosinofilia/induzido quimicamente , Coração Auxiliar , Animais , Arterite/etiologia , Arterite/fisiopatologia , Pressão Sanguínea , Bovinos , Ensaios Clínicos como Assunto , Eosinofilia/etiologia , Eosinofilia/fisiopatologia , Eosinófilos/citologia , Eosinófilos/efeitos dos fármacos , Infarto/patologia , Rim/irrigação sanguínea , Rim/patologia , Córtex Renal/irrigação sanguínea , Córtex Renal/patologia , Contagem de Leucócitos , Pulmão/irrigação sanguínea , Pulmão/patologia , Masculino , Artéria Pulmonar/patologia , beta-Lactamas/efeitos adversos
6.
Hand (N Y) ; 16(2): 241-247, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-31179742

RESUMO

Background: The purpose of the study was to determine the biomechanical effect of distal pin configuration in unilateral external fixation of distal radius fracture in a cadaveric model. Methods: A standardized 2-part extra-articular distal radius fracture model with dorsal comminution was created in 6 matched pairs of cadaveric upper extremities. Specimens within each matched pair were randomly assigned to either 4 or 6 cortices of distal pin metacarpal fixation. Cyclic, compressive loads were applied to the palmar hand. Results: No significant differences were detected in maximum forces. Six-cortex metacarpal fixation showed significantly lower magnitude of actuator displacement at 100 N cyclic loading. The difference in construct stiffness did not translate to disparities in angular and translational interfragmentary displacement at the fracture gap. Conclusions: Utilizing only 4 cortices and sparing the middle finger metacarpal avoids the need for a more transverse orientation required with 6-cortex fixation, which may otherwise impede thumb motion.


Assuntos
Ossos Metacarpais , Fraturas do Rádio , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Humanos , Ossos Metacarpais/cirurgia , Fraturas do Rádio/cirurgia
7.
J Orthop Res ; 38(12): 2619-2624, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32510162

RESUMO

Dwyer (lateral calcaneal closing wedge) osteotomy is commonly used in surgical correction of heel varus deformity. The purpose of this study was to determine the effect of wedge size and angle of osteotomy on deformity correction using preoperative imaging analysis with three-dimensional (3D) printed modeling. Seven patients diagnosed with pes cavovarus deformity who underwent Dwyer calcaneal osteotomy were identified retrospectively. Preoperative computed tomogrphy scans were used to create 3D printed models of the foot. After18 variations of osteotomy and fixation performed for each foot, Harris heel and Saltzman images were obtained. The angle between the tibia-talus axis and calcaneal-tuber axis was measured and compared to pre-osteotomy state. Change in the calcaneal lengths was also analyzed. The average degree correction of deformity per mm of bone resected was 3.8 ± 0.2 degrees in the Harris Heel view and 2.7 ± 0.8 degrees in the Saltzman view. A significant increase in correction was obtained with 10 mm compared with 5 mm wide wedges (P < .001). The difference in correction was not statistically significant between 30 and 45 degree cuts or osteotomy distance from the posterior calcaneal tuberosity, but a 45 degree sagittal angle resulted in less calcaneal shortening compared to 30 degrees (P = .02). A clinically driven method using patient-specific 3D models for determining effects of calcaneal osteotomy variables in correcting hindfoot alignment was developed. In summary, the amount of wedge resected impacts hindfoot alignment more than location and sagittal angle of the cut. Calcaneal shortening depends on sagittal angle of the cut.


Assuntos
Mau Alinhamento Ósseo/cirurgia , Calcâneo/cirurgia , Osteotomia/métodos , Modelagem Computacional Específica para o Paciente , Humanos , Osteotomia/estatística & dados numéricos , Impressão Tridimensional
8.
J Orthop Trauma ; 34(9): e298-e303, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32815840

RESUMO

OBJECTIVE: To determine if the addition of a dorsal ulnar pin plate provides improved stability characteristics in the management of intra-articular distal radius fractures with an associated dorsal ulnar fragment. METHODS: OTA/AO type C3 fractures, with a dorsal ulnar fragment of one-third or one-half the width of the distal radius, were simulated in 9 matched pairs of fresh-frozen cadaveric arms randomized between fixed-angle volar plate only versus volar plate with addition of a dorsal ulnar pin plate. Prepared specimens were mounted in a custom load frame and loaded in extension with stepwise cyclic load increase. Dorsal plane interfragmentary displacements were compared between the 2 fixation constructs at 50-N and 100-N cyclic load. RESULTS: The addition of the dorsal ulnar pin plate significantly reduced interfragmentary displacements for the dorsal ulnar fragment at the 50 N load application, resulting in mean interfragmentary displacements of -0.1 ± 0.2 mm in comparison to -0.3 ± 0.2 mm with the volar plate-only construct. No other interfragmentary displacement comparisons were significant. No differences were found comparing the one-third and one-half size fragments. CONCLUSIONS: The addition of a dorsal ulnar pin plate improved stability characteristics with respect to the dorsal ulnar fragment. CLINICAL RELEVANCE: The addition of the dorsal ulnar pin plate, although statistically significant, improved displacement by less than 0.3 mm on average and thus may not prove to be important in clinical scenarios.


Assuntos
Placas Ósseas , Fraturas do Rádio , Rádio (Anatomia) , Fenômenos Biomecânicos , Cadáver , Fixação Interna de Fraturas , Humanos , Fraturas do Rádio/cirurgia
9.
Foot Ankle Int ; 40(5): 596-602, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30822130

RESUMO

BACKGROUND: The structural importance of the spring ligament complex in arch stability has been described. Furthermore, the pathology of this complex is often noted in patients with posterior tibial tendon dysfunction. The purpose of this biomechanical study was to evaluate spring ligament repair alone versus augmentation with the FiberTape device in a cadaveric flatfoot model. METHODS: Eight paired, below-the-knee, cadaveric specimens underwent flatfoot creation and reconstruction. The experimental group received augmentation with FiberTape (InternalBrace). After potting, specimens were loaded statically to measure talonavicular contact pressures and flatfoot correction. Cyclic loading was performed in a stepwise fashion. Loading was performed at 1 Hz and 100 cycles, at 100-N intervals from 500 to 1800 N, with the Achilles tendon also loaded to simulate weightbearing in the postoperative period. RESULTS: Control specimen analysis demonstrated failures of 8 of 8 (100%) spring ligament suture repairs, occurring through suture cut-through (5 specimens), suture fatigue and elongation (2), or knot failure (1). One of 8 (12.5%) FiberTape-augmented repairs failed after cyclic loading. The difference in number of repair failures was statistically significant between the 2 groups ( P = .0014). Analysis revealed that at forces of 1600 N ( P = .03) and 1700 N ( P = .02) there were statistically significant differences between the FiberTape-augmented group and the control group, with a greater collapse in the lateral Meary talo-first metatarsal angle in the controls. There was no significant difference or abnormal increase in contact pressures of the talonavicular joint in both groups. CONCLUSION: FiberTape augmentation of the spring ligament appears biomechanically safe and effective under cyclic loading. CLINICAL RELEVANCE: Spring ligament augmentation with this device may be another biomechanically safe and reasonable treatment modality for surgeons during flatfoot reconstruction. It is possible that early protected weightbearing after these procedures may be performed.


Assuntos
Pé Chato/cirurgia , Ligamentos Articulares/cirurgia , Procedimentos de Cirurgia Plástica/instrumentação , Técnicas de Sutura/instrumentação , Suporte de Carga , Adulto , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
Foot Ankle Int ; 40(2): 231-236, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30345830

RESUMO

BACKGROUND:: Lesser toe proximal interphalangeal (PIP) joint arthrodesis is one of the most common foot and ankle elective procedures often using K-wires for fixation. K-wire associated complications led to development of intramedullary fixation devices. We hypothesized that X Fuse (Stryker) and Smart Toe (Stryker) would provide stronger and stiffer fixation than K-wire fixation. METHODS:: 12 cadaveric second toe pairs were used. In one group, K-wires stabilized 6 PIP joints, and 6 contralateral PIP joints were fixed with X Fuse. A second group used K-wires to stabilize 6 PIP joints, and 6 contralateral PIP joints were fixed with Smart Toe. Specimens were loaded cyclically with extension bending using 2-N step increases (10 cycles per step). Load to failure and initial stiffness were assessed. Statistical analysis used paired t tests. RESULTS:: K-wire average failure force, 91.0 N (SD 28.3), was significantly greater than X Fuse, 63.3 N (SD 12.9) ( P < .01). K-wire average failure force, 102.3 N (SD 17.7), was also significantly greater than Smart Toe, 53.3 N (SD 18.7) ( P < .01). K-wire initial stiffness 21.3 N/mm (SD 5.7) was greater than Smart Toe 14.4 N/mm (SD 9.3) ( P = .02). K-wire failure resulted from bending of K-wire or breaching cortical bone. X Fuse typically failed by implant pullout. Smart Toe failure resulted from breaching cortical bone. CONCLUSION:: K-wires may provide stiffer and stronger constructs in extension bending than the X Fuse or Smart Toe system. This cadaver study assessed stability of the fusion site at time zero after surgery. CLINICAL RELEVANCE:: Our findings provide new data supporting biomechanical stability of K-wires for lesser toe PIP arthrodesis, at least in this clinically relevant mode of cyclic loading.


Assuntos
Artrodese/instrumentação , Fios Ortopédicos , Síndrome do Dedo do Pé em Martelo/cirurgia , Fixadores Internos , Instabilidade Articular/cirurgia , Articulação do Dedo do Pé/cirurgia , Adulto , Fenômenos Biomecânicos , Cadáver , Feminino , Síndrome do Dedo do Pé em Martelo/fisiopatologia , Humanos , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Articulação do Dedo do Pé/fisiopatologia
11.
Clin Biomech (Bristol, Avon) ; 62: 23-27, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30658156

RESUMO

BACKGROUND: Successful tibiotalar joint fusion relies on adequate compression. Compression following joint preparation may be affected by the extent to which the fibula holds the joint out to anatomical length. The purpose of this study was to evaluate the effect of various distal fibula osteotomies on tibiotalar joint compression. METHODS: Eight adult cadaveric lower extremity specimens with an intact ankle joint and syndesmotic complex were evaluated. The ankle joint cartilage was denuded to subchondral bone. The fibula was surgically modified with three progressing procedures including an oblique fibula osteotomy, 1 cm resection, and distal fibula resection. A transducer was utilized to measure tibiotalar joint force, contact area, and peak pressure values while compressive forces of 30 N, 50 N, and 100 N were applied to the proximal tibia/fibula. FINDINGS: Distal fibula resection significantly increased tibiotalar joint force, contact area, and peak pressure the most of all fibula conditions tested compared to intact fibula control (p < .05). Tibiotalar joint force and peak pressures were significantly increased with a distal fibula oblique osteotomy, 1 cm resection, and complete resection under both 30 and 50 N applied compressive force (p < .05). INTERPRETATION: Complete distal fibular resection results in higher tibiotalar joint force, contact area, and peak pressure which may improve clinical rates of successful ankle fusion.


Assuntos
Articulação do Tornozelo/cirurgia , Fíbula/cirurgia , Osteotomia/métodos , Adulto , Articulação do Tornozelo/fisiologia , Artrodese , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tíbia , Suporte de Carga/fisiologia
12.
Foot Ankle Spec ; 12(4): 316-321, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30168360

RESUMO

Background: The pathophysiology of adult-acquired flatfoot deformity (AAFD) is not fully explained by degeneration of the posterior tibial tendon alone. While a shortened or dysplastic lateral column has been implicated in flatfoot deformity in pediatrics, there is no study that has quantified the degree of dysplasia in adults with a stage IIb flatfoot deformity, or if any exists at all. Methods: An institutional radiology database was queried for patients with posterior tibial tendon dysfunction (PTTD) who had computed tomography (CT) performed. Controls were patients receiving CT scan for an intra-articular distal tibia fracture without preexisting foot or calcaneal pathology. Clinical notes, physical examination, and weightbearing radiographs were used to find patients that met clinical criteria for stage IIb PTTD. Morphometric measurements of the calcanei were performed involving the length of the calcaneal axis (LCA), height of the anterior process (HAP), and length of the anterior process (LAP). All measurements were performed independently by separate observers, with observers blinded to group assignment. We considered a difference of ±4 mm as our threshold. Results: 7 patients and 7 controls were available for reconstruction and analysis. On average, the LCA was 3.1 mm shorter in patients with stage IIb PTTD compared with controls (P < .05). The LAP was shorter in PTTD patients compared with controls 3.4 mm (P < .001). Conclusions: Our results support the hypothesis that the calcaneus of adult patients with stage IIb AAFD is dysplastic when compared with healthy controls, which further supports the utility of lateral column lengthening. Levels of Evidence: Level III: Case-control study.


Assuntos
Antropometria/métodos , Calcâneo/patologia , Imageamento Tridimensional/métodos , Disfunção do Tendão Tibial Posterior/patologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Disfunção do Tendão Tibial Posterior/diagnóstico por imagem , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Adulto Jovem
13.
J Orthop Res ; 35(4): 800-804, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27279527

RESUMO

Destruction of the normal metatarsal arch by a long metatarsal is often a cause for metatarsalgia. When surgery is warranted, distal oblique, or proximal dorsiflexion osteotomies of the long metatarsal bones are commonly used. The plantar fascia has anatomical connection to all metatarsal heads. There is controversial scientific evidence on the effect of plantar fascia release on forefoot biomechanics. In this cadaveric biomechanical study, we hypothesized that plantar fascia release would augment the plantar metatarsal pressure decreasing effects of two common second metatarsal osteotomy techniques. Six matched pairs of foot and ankle specimens were mounted on a pressure mat loading platform. Two randomly assigned surgery groups, which had received either distal oblique, or proximal dorsiflexion osteotomy of the second metatarsal, were evaluated before and after plantar fasciectomy. Specimens were loaded up to a ground reaction force of 400 N at varying Achilles tendon forces. Average pressures, peak pressures, and contact areas were analyzed. Supporting our hypothesis, average pressures under the second metatarsal during 600 N Achilles load were decreased by plantar fascia release following proximal osteotomy (p < 0.05). However contrary to our hypothesis, peak pressures under the second metatarsal were significantly increased by plantar fascia release following modified distal osteotomy, under multiple Achilles loading conditions (p < 0.05). Plantar fasciotomy should not be added to distal metatarsal osteotomy in the treatment of metatarsalgia. If proximal dorsiflexion osteotomy would be preferred, plantar fasciotomy should be approached cautiously not to disturb the forefoot biomechanics. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:800-804, 2017.


Assuntos
Fáscia/fisiopatologia , Pé/cirurgia , Metatarsalgia/cirurgia , Osteotomia/métodos , Tendão do Calcâneo/fisiopatologia , Fenômenos Biomecânicos , Cadáver , Feminino , Pé/fisiopatologia , Antepé Humano , Humanos , Masculino , Ossos do Metatarso/fisiopatologia , Metatarsalgia/fisiopatologia , Pessoa de Meia-Idade , Pressão , Distribuição Aleatória , Procedimentos Cirúrgicos Operatórios , Tíbia/fisiologia , Suporte de Carga
14.
J Orthop Res ; 35(5): 997-1006, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27381807

RESUMO

The time-course of cancellous bone regeneration surrounding mechanically loaded implants affects implant fixation, and is relevant to determining optimal rehabilitation protocols following orthopaedic surgeries. We investigated the influence of controlled mechanical loading of titanium-coated polyether-ether ketone (PEEK) implants on osseointegration using time-lapsed, non-invasive, in vivo micro-computed tomography (micro-CT) scans. Implants were inserted into proximal tibial metaphyses of both limbs of eight female Sprague-Dawley rats. External cyclic loading (60 or 100 µm displacement, 1 Hz, 60 s) was applied every other day for 14 days to one implant in each rat, while implants in contralateral limbs served as the unloaded controls. Hind limbs were imaged with high-resolution micro-CT (12.5 µm voxel size) at 2, 5, 9, and 12 days post-surgery. Trabecular changes over time were detected by 3D image registration allowing for measurements of bone-formation rate (BFR) and bone-resorption rate (BRR). At day 9, mean %BV/TV for loaded and unloaded limbs were 35.5 ± 10.0% and 37.2 ± 10.0%, respectively, and demonstrated significant increases in bone volume compared to day 2. BRR increased significantly after day 9. No significant differences between bone volumes, BFR, and BRR were detected due to implant loading. Although not reaching significance (p = 0.16), an average 119% increase in pull-out strength was measured in the loaded implants. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:997-1006, 2017.


Assuntos
Interface Osso-Implante/diagnóstico por imagem , Osseointegração , Microtomografia por Raio-X/métodos , Animais , Imageamento Tridimensional , Modelos Animais , Ratos , Ratos Sprague-Dawley , Suporte de Carga
15.
Injury ; 47(8): 1624-30, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27324325

RESUMO

INTRODUCTION: Variable angle (VA) locking plates in fracture fixation surgery allow screws to be fastened to the plate within a conical "locus of vectors" in order to avoid existing prostheses, joint surfaces, or poor quality bone. Clinical failures of VA constructs in which screws have rotated at the plate/screw interface have been reported raising the concern that there may be a biomechanical cost for the increased flexibility that VA provides. The objective of this study was to test the mechanical properties of one commonly used VA locking mechanism with screws placed in both nominal and off-axis trajectories and compare these against the standard locking mechanism. METHODS: VA locking screws were inserted into plates for distal femur fractures (VA Curved Condylar) at various angles (0° to 15° away from perpendicular). A control group of standard locking screws/plates was also tested. Maximum moment at the screw/plate interface and moment at two reference displacements were determined. RESULTS: VA screws locked perpendicular to the plate provided the greatest maximum moment and moment at the reference displacements when using the VA system, and demonstrated lower moments compared to standard locking screws/plates (p<0.001). Based on linear regression, there was an average decrease of approximately 0.4 Nm screw-plate interface strength for every 1° increase in screw-plate angle (p<0.001). Decreases (p<0.05) were discovered in both maximum moment and moment at the reference displacements for screws locked at 5° relative to those locked at 0°, 10° relative to 0°, and 15° relative to 10°. DISCUSSION: Standard locking systems provided greater resistance to rotational failure at the screw/plate interface than variable angle locking systems. Variable angle systems provided the greatest resistance to rotation when the screw was inserted perpendicular to the plate. As the off-axis angle increased, the resistance to rotation at the screw/plate interface decreased almost linearly. It is unknown if these differences are clinically significant in an actual fracture construct, but recent reported failures in the distal femur suggest that they might be. CONCLUSION: Surgeons should weigh the risks and benefits of VA systems and attempt to minimize the off-axis angle magnitude when VA systems are selected.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Teste de Materiais/métodos , Fenômenos Biomecânicos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Impressão Tridimensional , Estresse Mecânico
16.
J Orthop Res ; 34(4): 666-74, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26356804

RESUMO

Restoration of joint stability during total shoulder arthroplasty can be challenging in the face of severe glenoid retroversion. A novel technique of humeral head component anterior-offsetting has been proposed to address posterior instability. We evaluated the biomechanical benefits of this technique in cadaveric specimens. Total shoulder arthroplasty was performed in 14 cadaveric shoulders from 7 donors. Complementary shoulders were assigned to either 10° or 20° glenoid retroversion, with retroversion created by eccentric reaming. Two humeral head component offset positions were tested in each specimen: The anatomic (posterior) and anterior (reverse). With loads applied to the rotator cuff and deltoid, joint contact pressures and the force and energy required for posterior humeral head translation were measured. The force and energy required to displace the humeral head posteriorly increased significantly with the anterior offset position compared to the anatomic offset position. The joint contact pressures were significantly shifted anteriorly, and the joint contact area significantly increased with the anterior offset position. Anterior offsetting of the humeral head component increased the resistance to posterior humeral head translation, shifted joint contact pressures anteriorly, and increased joint contact area, thus, potentially increasing the joint stability in total shoulder arthroplasty with simulated glenoid retroversion.


Assuntos
Artroplastia/métodos , Articulação do Ombro/cirurgia , Adulto , Humanos , Úmero/fisiologia , Pessoa de Meia-Idade , Articulação do Ombro/fisiologia
17.
J Bone Joint Surg Am ; 97(23): 1945-51, 2015 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-26631995

RESUMO

BACKGROUND: The optimal surgery for reducing pressure under the second metatarsal head to treat metatarsalgia is unknown. We tested our hypothesis that a proximal oblique dorsiflexion osteotomy of the second metatarsal would decrease second-metatarsal plantar pressures in a cadaver model with varying Achilles tendon tension. We also tested the plantar pressure effects of two popular techniques of distal oblique osteotomy. METHODS: Twelve fresh-frozen feet from six cadavers were randomly assigned to either the distal osteotomy group (a classic distal oblique osteotomy followed by a modified distal oblique osteotomy) or proximal metatarsal osteotomy group. Each specimen was tested intact and then after the osteotomy or osteotomies. The feet were loaded with 0, 300, and 600 N of Achilles tendon tension and a 400-N ground reaction force. Plantar pressures were measured by a pressure sensitive mat and analyzed in sections located under each metatarsal. RESULTS: The proximal metatarsal osteotomy significantly reduced average pressures beneath the second metatarsal head during both 300 and 600 N of Achilles tendon loading by an average of 19.4 and 29.7 kPa, respectively (p < 0.05). The modified distal oblique osteotomy significantly decreased these pressures during 600 N of Achilles tendon loading, by a mean of 20.2 kPa, which was to a lesser extent than the proximal metatarsal osteotomy. Interestingly, the classic distal oblique osteotomy was not found to have significant effects on pressures beneath the second metatarsal head. CONCLUSIONS: The proximal oblique dorsiflexion metatarsal osteotomy may be the most effective procedure for decreasing plantar pressures under the second metatarsal. The modified distal oblique osteotomy may be the second most effective. CLINICAL RELEVANCE: The findings of this biomechanical study help shed light on which of the common second metatarsal osteotomies are best for decreasing plantar pressures.


Assuntos
Tendão do Calcâneo/fisiologia , Ossos do Metatarso/cirurgia , Osteotomia/métodos , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Distribuição Aleatória , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA