Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Anal Chem ; 96(23): 9493-9502, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38790145

RESUMO

The health hazards of micro- and nanoplastic contaminants in drinking water has recently emerged as an area of concern to policy makers and industry. Plastic contaminants range in size from micro- (5 mm to 1 µm) to nanoplastics (<1 µm). Microfluidics provides many tools for particle manipulation at the microscale, particularly in diagnostics and biomedicine, but has in general a limited capacity to process large volumes. Drinking water and environmental samples with low-level contamination of microplastics require processing of deciliter to liter sample volumes to achieve statistically relevant particle counts. Here, we introduce the EchoGrid, an acoustofluidics device for high throughput continuous flow particle enrichment into a robust array of particle clusters. The EchoGrid takes advantage of highly efficient particle capture through the integration of a micropatterned transducer for surface displacement-based acoustic trapping in a glass and polymer microchannel. Silica seed particles were used as anchor particles to improve capture performance at low particle concentrations and high flow rates. The device was able to maintain the silica grids at a flow rate of 50 mL/min. In terms of enrichment, the device is able to double the final pellet's microplastic concentration every 78 s for 23 µm particles and every 51 s for 10 µm particles at a flow rate of 5 mL/min. In conclusion, we demonstrate the usefulness of the EchoGrid by capturing microplastics in challenging conditions, such as large sample volumes with low microparticle concentrations, without sacrificing the potential of integration with downstream analysis for environmental monitoring.

2.
J Transl Med ; 22(1): 530, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831317

RESUMO

BACKGROUND: Cancer stem-like cells (CSCs) have been extensively researched as the primary drivers of therapy resistance and tumor relapse in patients with breast cancer. However, due to lack of specific molecular markers, increased phenotypic plasticity and no clear clinicopathological features, the assessment of CSCs presence and functionality in solid tumors is challenging. While several potential markers, such as CD24/CD44, have been proposed, the extent to which they truly represent the stem cell potential of tumors or merely provide static snapshots is still a subject of controversy. Recent studies have highlighted the crucial role of the tumor microenvironment (TME) in influencing the CSC phenotype in breast cancer. The interplay between the tumor and TME induces significant changes in the cancer cell phenotype, leading to the acquisition of CSC characteristics, therapeutic resistance, and metastatic spread. Simultaneously, CSCs actively shape their microenvironment by evading immune surveillance and attracting stromal cells that support tumor progression. METHODS: In this study, we associated in vitro mammosphere formation assays with bulk tumor microarray profiling and deconvolution algorithms to map CSC functionality and the microenvironmental landscape in a large cohort of 125 breast tumors. RESULTS: We found that the TME score was a significant factor associated with CSC functionality. CSC-rich tumors were characterized by an immune-suppressed TME, while tumors devoid of CSC potential exhibited high immune infiltration and activation of pathways involved in the immune response. Gene expression analysis revealed IFNG, CXCR5, CD40LG, TBX21 and IL2RG to be associated with the CSC phenotype and also displayed prognostic value for patients with breast cancer. CONCLUSION: These results suggest that the characterization of CSCs content and functionality in tumors can be used as an attractive strategy to fine-tune treatments and guide clinical decisions to improve patients therapy response.


Assuntos
Neoplasias da Mama , Regulação Neoplásica da Expressão Gênica , Células-Tronco Neoplásicas , Microambiente Tumoral , Humanos , Neoplasias da Mama/patologia , Neoplasias da Mama/genética , Células-Tronco Neoplásicas/metabolismo , Células-Tronco Neoplásicas/patologia , Feminino , Transcrição Gênica , Perfilação da Expressão Gênica , Linhagem Celular Tumoral , Esferoides Celulares/patologia , Esferoides Celulares/metabolismo , Fenótipo
3.
Methods Mol Biol ; 2804: 127-138, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753145

RESUMO

Within the vast field of medical biotechnology, the biopharmaceutical industry is particularly fast-growing and highly competitive, so reducing time and costs associated to process optimization becomes instrumental to ensure speed to market and, consequently, profitability. The manufacturing of biopharmaceutical products, namely, monoclonal antibodies (mAbs), relies mostly on mammalian cell culture processes, which are highly dynamic and, consequently, difficult to optimize. In this context, there is currently an unmet need of analytical methods that can be integrated at-line in a bioreactor, for systematic monitoring and quantification of key metabolites and proteins. Microfluidic-based assays have been extensively and successfully applied in the field of molecular diagnostics; however, this technology remains largely unexplored for Process Analytical Technology (PAT), despite holding great potential for the at-line measurement of different analytes in bioreactor processes, combining low reagent/molecule consumption with assay sensitivity and rapid turnaround times.Here, the fabrication and handling of a microfluidic cartridge for protein quantification using bead-based affinity assays is described. The device allows geometrical multiplexed immunodetection of specific protein analytes directly from bioreactor samples within 2.5 h and minimal hands-on time. As a proof-of-concept, quantification of Chinese hamster ovary (CHO) host cell proteins (HCP) as key impurities, IgG as product of interest, and lactate dehydrogenase (LDH) as cell viability marker was demonstrated with limits of detection (LoD) in the low ng/mL range. Negligible matrix interference and no cross-reactivity between the different immunoassays on chip were found. The results highlight the potential of the miniaturized analytical method for PAT at reduced cost and complexity in comparison with sophisticated instruments that are currently the state-of-the-art in this context.


Assuntos
Cricetulus , Células CHO , Animais , Anticorpos Monoclonais/imunologia , Reatores Biológicos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Imunoensaio/métodos , Imunoensaio/instrumentação , Microfluídica/métodos , Microfluídica/instrumentação , Cricetinae
4.
Life Sci ; 354: 122982, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39151886

RESUMO

AIMS: While enhanced tumor cell migration is a key process in the tumor dissemination, mechanistic insights into causal relationships between tumor cells and mechanical confinement are still limited. Here we combine the use of microfluidic platforms to characterize confined cell migration with genomic tools to systematically unravel the global signaling landscape associated with the migratory phenotype of breast cancer (BC) cells. METERIALS AND METHODS: The spontaneous migration capacity of seven BC cell lines was evaluated in 3D microfluidic devices and their migration capacity was correlated with publicly available molecular signatures. The role of identified signaling pathways on regulating BC migration capacity was determined by receptor stimulation through ligand binding or inhibition through siRNA silencing. Downstream effects on cell migration were evaluated in microfluidic devices, while the molecular changes were monitored by RT-qPCR. KEY FINDINGS: Expression of 715 genes was correlated with BC cells migratory phenotype, revealing TNF-α as one of the top upstream regulators. Signal transduction experiments revealed that TNF-α stimulates the confined migration of triple negative, mesenchymal-like BC cells that are also characterized by high TNFR1 expression, but inhibits the migration of epithelial-like cells with low TNFR1 expression. TNFR1 was strongly associated with the migration capacity and triple-negative, mesenchymal phenotype. Downstream of TNF/TNFR1 signaling, transcriptional regulation of NFKB seems to be important in driving cell migration in confined spaces. SIGNIFICANCE: TNF-α/TNFR1 signaling axis reveals as a key player in driving BC cells confined migration, emerging as a promising therapeutic strategy in targeting dissemination and metastasis of triple negative, mesenchymal BC cells.

5.
Microsyst Nanoeng ; 10: 87, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38919163

RESUMO

The combination of flow elasticity and inertia has emerged as a viable tool for focusing and manipulating particles using microfluidics. Although there is considerable interest in the field of elasto-inertial microfluidics owing to its potential applications, research on particle focusing has been mostly limited to low Reynolds numbers (Re<1), and particle migration toward equilibrium positions has not been extensively examined. In this work, we thoroughly studied particle focusing on the dynamic range of flow rates and particle migration using straight microchannels with a single inlet high aspect ratio. We initially explored several parameters that had an impact on particle focusing, such as the particle size, channel dimensions, concentration of viscoelastic fluid, and flow rate. Our experimental work covered a wide range of dimensionless numbers (0.05 < Reynolds number < 85, 1.5 < Weissenberg number < 3800, 5 < Elasticity number < 470) using 3, 5, 7, and 10 µm particles. Our results showed that the particle size played a dominant role, and by tuning the parameters, particle focusing could be achieved at Reynolds numbers ranging from 0.2 (1 µL/min) to 85 (250 µL/min). Furthermore, we numerically and experimentally studied particle migration and reported differential particle migration for high-resolution separations of 5 µm, 7 µm and 10 µm particles in a sheathless flow at a throughput of 150 µL/min. Our work elucidates the complex particle transport in elasto-inertial flows and has great potential for the development of high-throughput and high-resolution particle separation for biomedical and environmental applications.

6.
Micromachines (Basel) ; 15(6)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38930678

RESUMO

Laboratory automation effectively increases the throughput in sample analysis, reduces human errors in sample processing, as well as simplifies and accelerates the overall logistics. Automating diagnostic testing workflows in peripheral laboratories and also in near-patient settings -like hospitals, clinics and epidemic control checkpoints- is advantageous for the simultaneous processing of multiple samples to provide rapid results to patients, minimize the possibility of contamination or error during sample handling or transport, and increase efficiency. However, most automation platforms are expensive and are not easily adaptable to new protocols. Here, we address the need for a versatile, easy-to-use, rapid and reliable diagnostic testing workflow by combining open-source modular automation (Opentrons) and automation-compatible molecular biology protocols, easily adaptable to a workflow for infectious diseases diagnosis by detection on paper-based diagnostics. We demonstrated the feasibility of automation of the method with a low-cost Neisseria meningitidis diagnostic test that utilizes magnetic beads for pathogen DNA isolation, isothermal amplification, and detection on a paper-based microarray. In summary, we integrated open-source modular automation with adaptable molecular biology protocols, which was also faster and cheaper to perform in an automated than in a manual way. This enables a versatile diagnostic workflow for infectious diseases and we demonstrated this through a low-cost N. meningitidis test on paper-based microarrays.

7.
BMJ Glob Health ; 8(12)2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38114235

RESUMO

Diagnostics are widely considered crucial in the fight against antimicrobial resistance (AMR), which is expected to kill 10 million people annually by 2030. Nevertheless, there remains a substantial gap between the need for AMR diagnostics versus their development and implementation. To help address this problem, target product profiles (TPP) have been developed to focus developers' attention on the key aspects of AMR diagnostic tests. However, during discussion between a multisectoral working group of 51 international experts from industry, academia and healthcare, it was noted that specific AMR-related TPPs could be extended by incorporating the interdependencies between the key characteristics associated with the development of such TPPs. Subsequently, the working group identified 46 characteristics associated with six main categories (ie, Intended Use, Diagnostic Question, Test Description, Assay Protocol, Performance and Commercial). The interdependencies of these characteristics were then identified and mapped against each other to generate new insights for use by stakeholders. Specifically, it may not be possible for diagnostics developers to achieve all of the recommendations in every category of a TPP and this publication indicates how prioritising specific TPP characteristics during diagnostics development may influence (or not) a range of other TPP characteristics associated with the diagnostic. The use of such guidance, in conjunction with specific TPPs, could lead to more efficient AMR diagnostics development.


Assuntos
Testes Diagnósticos de Rotina , Resistência Microbiana a Medicamentos , Humanos , Testes Diagnósticos de Rotina/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA