Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Appl Biomed ; 17(2): 91-98, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34907736

RESUMO

Magnetic Resonance (MR) compatible ergometers are specialized ergometers used inside the MR scanners for the characterization of tissue metabolism changes during physical stress. They are most commonly used for dynamic phosphorous magnetic resonance spectroscopy (31P MRS), but can also be used for lactate production measurements, perfusion studies using arterial spin labelling or muscle oxygenation measurements by blood oxygen dependent contrast sequences. We will primarily discuss the importance of ergometers in the context of dynamic 31P MRS. Dynamic 31P MRS can monitor muscle fatigue and energy reserve during muscle contractions as well as the dynamics of recuperation of skeletal muscle tissue during the following recovery through signal changes of phosphocreatine (PCr), inorganic phosphate and adenosine triphosphate (ATP). Based on the measured data it is possible to calculate intracellular pH, metabolic flux of ATP through creatine-kinase reaction, anaerobic glycolysis and oxidative phosphorylation and other metabolic parameters as mitochondrial capacity. This review primarily focuses on describing various technical designs of MR compatible ergometers for dynamic 31P MRS that must be constructed with respect to the presence of magnetic field. It is also expected that the construction of ergometers will be easy for the handling and well accepted by examined subjects.

2.
Psychiatr Danub ; 27 Suppl 1: S269-72, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26417778

RESUMO

It has been repeatedly shown that schizophrenia patients have immense alterations in goal-directed behaviour, social cognition, and social interactions, cognitive abilities that are presumably driven by the mirror neurons system (MNS). However, the neural bases of these deficits still remain unclear. Along with the task-related fMRI and EEG research tapping into the mirror neuron system, the characteristics of the resting state activity in the particular areas that encompass mirror neurons might be of interest as they obviously determine the baseline of the neuronal activity. Using resting state fMRI, we investigated resting state functional connectivity (FC) in four predefined brain structures, ROIs (inferior frontal gyrus, superior parietal lobule, premotor cortex and superior temporal gyrus), known for their mirror neurons activity, in 12 patients with first psychotic episode and 12 matched healthy individuals. As a specific hypothesis, based on the knowledge of the anatomical inputs of thalamus to all preselected ROIs, we have investigated the FC between thalamus and the ROIs. Of all ROIs included, seed-to-voxel connectivity analysis revealed significantly decreased FC only in left posterior superior temporal gyrus (STG) and the areas in visual cortex and cerebellum in patients as compared to controls. Using ROI-to-ROI analysis (thalamus and selected ROIs), we have found an increased FC of STG and bilateral thalamus whereas the FC of these areas was decreased in controls. Our results suggest that: (1) schizophrenia patients exhibit FC of STG which corresponds to the previously reported changes of superior temporal gyrus in schizophrenia and might contribute to the disturbances of specific functions, such as emotional processing or spatial awareness; (2) as the thalamus plays a pivotal role in the sensory gating, providing the filtering of the redundant stimulation, the observed hyperconnectivity between the thalami and the STGs in patients with schizophrenia might explain the sequential overload with sensory inputs that leads to the abnormal cognitive processing.


Assuntos
Mapeamento Encefálico , Encéfalo/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Neurônios-Espelho/fisiologia , Vias Neurais/fisiopatologia , Esquizofrenia/fisiopatologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Lobo Temporal/fisiopatologia , Adulto Jovem
3.
Med Phys ; 50(12): 8063-8068, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37665757

RESUMO

BACKGROUND: During and after exercise, dynamic 31 P MR parameters are typically measured using an MR-compatible ergometer. Self-built equipment for local condition can be constructed where possible. PURPOSE: To develop a pedal resistance ergometer with rocker arm based on a system that combines electric weight displacement, visual self-monitoring, and exercise triggering. The repeatability and reproducibility were tested. METHODS: The hardware and software for the ergometer were constructed from commercial components in a home laboratory. Twelve volunteers participated in the testing of the ergometer. RESULTS: A fully automated ergometer system was developed, allowing the pedal resistance to be adjusted during the examination. The system includes a self-monitoring and triggering mechanism that enables both the operator and subject to monitor pedal frequency and force. The operator can modify the pedal resistance as desired during the exercise. This self-monitoring solution is simple and cost-effective, requiring only a commercial potentiometer, an Arduino converter, and a conventional video projector with a personal computer (PC). Additionally, all system components are located outside the magnetic resonance (MR) room, avoiding interference with the MR system. Results of several test of the reproducibility/repeatability of power at three pedal resistance values (15%, 24%, 25% maximal voluntary force) were expressed both as a coefficient of variation ranging from 6% to 3.1% and as an intraclass correlation of coefficient ranging from 0.96 to 0.99. Similar values were also found for other dynamic parameters of 31 P MR spectroscopy. These findings are similar to published data obtained on different types of ergometers. CONCLUSIONS: Based on more than 1 year of usage, the ergometer proved successful in handling stationary and variable loads, and can be easily operated by a single user.


Assuntos
Retroalimentação Sensorial , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Espectroscopia de Ressonância Magnética/métodos , Exercício Físico
4.
Psychophysiology ; 59(10): e14075, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35460523

RESUMO

Functional connectivity analysis is a common approach to the characterization of brain function. While studies of functional connectivity have predominantly focused on resting-state fMRI, naturalistic paradigms, such as movie watching, are increasingly being used. This ecologically valid, yet relatively unconstrained acquisition state has been shown to improve subject compliance and, potentially, enhance individual differences. However, unlike the reliability of resting-state functional connectivity, the reliability of functional connectivity during naturalistic viewing has not yet been fully established. The current study investigates the intra-session reliability of functional connectivity during naturalistic viewing sessions to extend its understanding. Using fMRI data of 24 subjects measured at rest as well as during six naturalistic viewing conditions, we quantified the split-half reliability of each condition, as well as cross-condition reliabilities. We find that intra-session reliability is relatively high for all conditions. While cross-condition reliabilities are higher for pairings of two naturalistic viewing conditions, split-half reliability is highest for the resting state. Potential sources of variability across the conditions, as well as the strengths and limitations of using intra-session reliability as a measure in naturalistic viewing, are discussed.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Humanos , Individualidade , Filmes Cinematográficos , Reprodutibilidade dos Testes
5.
Eur J Phys Rehabil Med ; 57(3): 356-365, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32935954

RESUMO

BACKGROUND: Imaging methods bring new possibilities for describing the brain plasticity processes that underly the improvement of clinical function after physiotherapy in people with multiple sclerosis (pwMS). Although these processes have been described mainly in connection with task-oriented physiotherapy and aerobic training, they have not been properly verified in neuroproprioceptive "facilitation, inhibition" (facilitation) approaches. AIM: The study determined whether facilitation physiotherapy could enhance brain plasticity, compared two facilitation methods and looked for any relation to clinical improvement in pwMS. DESIGN: The study was designed as parallel group randomized comparison of two kinds of physiotherapeutic interventions referred to healthy controls. SETTING: Thirty-eight outpatients were involved in the study. POPULATION: The study had 80 participants (38 pwMS and 42 healthy controls). METHODS: PwMS were divided into two groups and underwent a two-month physiotherapy program: Vojta reflex locomotion (VRL) or Motor program activating therapy (MPAT), (1 hour, twice a week). Functional magnetic resonance imaging (fMRI) and clinical examination was performed before and after therapy. Healthy controls underwent one fMRI examination. RESULTS: Physiotherapy in pwMS leads to extension of brain activity in specific brain areas (cerebellum, supplementary motor areas and premotor areas) in connection with the improvement of the clinical status of individual patients after therapy (P=0.05). Greater changes (P=0.001) were registered after MPAT than after VRL. The extension of activation was a shift to the examined activation of healthy controls, whose activation was higher in the cerebellum and secondary visual area (P=0.01). CONCLUSIONS: Neuroproprioceptive "facilitation, inhibition" physiotherapy may enhance brain activity and could involve processes connected with the processing of motion activation. CLINICAL REHABILITATION IMPACT: The study showed that facilitation approach can modulate brain activity. This could be useful for developing of effective physiotherapeutic treatment in MS.


Assuntos
Encéfalo/diagnóstico por imagem , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/terapia , Modalidades de Fisioterapia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
6.
PLoS One ; 15(6): e0232570, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32484832

RESUMO

In the last years, there has been a considerable increase of research into the neuroimaging correlates of inter-individual temperament and character variability-an endeavour for which the term 'personality neuroscience' was coined. Among other neuroimaging modalities and approaches, substantial work focuses on functional connectivity in resting state (rs-FC) functional magnetic resonance imaging data. In the current paper, we set out to independently query the questions asked in a highly cited study that reported a range of functional connectivity correlates of personality dimensions assessed by the widely used 'Big Five' Personality Inventory. Using a larger sample (84 subjects) and an equivalent data analysis pipeline, we obtained widely disagreeing results compared to the original study. Overall, the results were in line with the hypotheses of no relation between functional connectivity and personality, when more precise permutation-based multiple testing procedures were applied. The results demonstrate that as with other neuroimaging studies, great caution should be applied when interpreting the findings, among other reasons due to multiple testing problem involved at several levels in many neuroimaging studies. Of course, the current study results can not ultimately disprove the existence of some link between personality and brain's intrinsic functional architecture, but clearly shows that its form is very likely different and much more subtle and elusive than was previously reported.


Assuntos
Encéfalo/fisiologia , Personalidade/fisiologia , Adulto , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Vias Neurais/diagnóstico por imagem , Vias Neurais/fisiologia , Testes de Personalidade , Descanso
7.
Schizophr Bull ; 42(4): 916-25, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26685867

RESUMO

BACKGROUND: The phenomenology of the clinical symptoms indicates that disturbance of the sense of self be a core marker of schizophrenia. AIMS: To compare neural activity related to the self/other-agency judgment in patients with first-episode schizophrenia-spectrum disorders (FES, n = 35) and healthy controls (HC, n = 35). METHOD: A functional magnetic resonance imaging (fMRI) using motor task with temporal distortion of the visual feedback was employed. A task-related functional connectivity was analyzed with the use of independent component analysis (ICA). RESULTS: (1) During self-agency experience, FES showed a deficit in cortical activation in medial frontal gyrus (BA 10) and posterior cingulate gyrus, (BA 31; P < .05, Family-Wise Error [FWE] corrected). (2) Pooled-sample task-related ICA revealed that the self/other-agency judgment was dependent upon anti-correlated default mode and central-executive networks (DMN/CEN) dynamic switching. This antagonistic mechanism was substantially impaired in FES during the task. DISCUSSION: During self-agency experience, FES demonstrate deficit in engagement of cortical midline structures along with substantial attenuation of anti-correlated DMN/CEN activity underlying normal self/other-agency discriminative processes.


Assuntos
Conectoma/métodos , Giro do Cíngulo/fisiopatologia , Rede Nervosa/fisiopatologia , Transtornos da Percepção/fisiopatologia , Córtex Pré-Frontal/fisiopatologia , Esquizofrenia/fisiopatologia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Atividade Motora , Transtornos da Percepção/etiologia , Desempenho Psicomotor , Esquizofrenia/complicações
8.
Med Phys ; 42(4): 1678-89, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25832057

RESUMO

PURPOSE: Dynamic phosphorus magnetic resonance spectroscopy ((31)P MRS) during and after acute exercise enables the noninvasive in vivo determination of the mitochondrial capacity of skeletal muscle. Nevertheless, the lack of standardization in experimental setups leads to significant variations in published values of maximal aerobic capacity, even in the population of healthy volunteers. Thus, in this study, we aimed to assess the impact of the ergometer type (pneumatic and mechanical resistance construction), radiofrequency (RF)-coil diameter, and different magnetic field strengths (3 and 7 T) on the metabolic parameters measured by dynamic (31)P MRS during a plantar flexion isotonic exercise protocol within the same group of healthy volunteers. METHODS: Dynamic (31)P MRS measurements of the calf muscle in 11 volunteers (mean age, 36 ± 13 yrs; mean BMI, 23.5 ± 2.5 kg/m(2)), on a 3 T MR system with a custom-made mechanical ergometer in the first research laboratory (RL1) and on 3 and 7 T MR systems equipped with a commercial pneumatic ergometer in the second research laboratory (RL2), were performed at three different workloads. RF-coils differed slightly between the sites and MR systems used. The repeatability of the experimental protocol was tested in every setup. The basal concentrations of phosphocreatine (PCr), exercise-induced depletion of PCr (ΔPCr), initial PCr resynthesis rate (VPCr), and mitochondrial capacity (Qmax) were calculated and compared between the research sites and field strengths. RESULTS: High repeatability of the measurement protocol was found in every experimental setup. No significant differences at any workload were found in these metabolic parameters assessed at different magnetic field strengths (3 T vs 7 T), using the same ergometer (in RL2) and a similar RF-coil. In the inter-research laboratory comparison at the same field strength (3 T), but with using different ergometers and RF-coils, differences were found in the concentration of PCr measured at rest and in the drop in PCr signal intensity. These differences translated into difference in the value of mitochondrial capacity at a workload of 15% of maximal voluntary contraction (MVC) force (0.45 ± 0.16 mM/s vs 0.31 ± 0.08 mM/s, in the RL1 and RL2, respectively). CONCLUSIONS: Metabolic parameters measured during exercise challenge by dynamic (31)P MRS do not depend upon the magnetic field strength used. For multicenter studies with different ergometers, it is important to set the same workload, measurement, and evaluation protocols, especially when the effects of very mild exercise (15% MVC) are to be compared. However, a higher workload (24% MVC) decreases the influence of imperfections and intersite differences for the assessed value of maximal mitochondrial capacity.


Assuntos
Ergometria/instrumentação , Contração Isotônica/fisiologia , Perna (Membro)/fisiologia , Espectroscopia de Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/métodos , Músculo Esquelético/metabolismo , Adulto , Desenho de Equipamento , Ergometria/métodos , Exercício Físico/fisiologia , Feminino , Humanos , Campos Magnéticos , Masculino , Mitocôndrias/metabolismo , Fosfocreatina/metabolismo , Isótopos de Fósforo , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA