Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sensors (Basel) ; 22(8)2022 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-35458883

RESUMO

Epilepsy is a chronic disease with a significant social impact, given that the patients and their families often live conditioned by the possibility of an epileptic seizure and its possible consequences, such as accidents, injuries, or even sudden unexplained death. In this context, ambulatory monitoring allows the collection of biomedical data about the patients' health, thus gaining more knowledge about the physiological state and daily activities of each patient in a more personalized manner. For this reason, this article proposes a novel monitoring system composed of different sensors capable of synchronously recording electrocardiogram (ECG), photoplethysmogram (PPG), and ear electroencephalogram (EEG) signals and storing them for further processing and analysis in a microSD card. This system can be used in a static and/or ambulatory way, providing information about the health state through features extracted from the ear EEG signal and the calculation of the heart rate variability (HRV) and pulse travel time (PTT). The different applied processing techniques to improve the quality of these signals are described in this work. A novel algorithm used to compute HRV and PTT robustly and accurately in ambulatory settings is also described. The developed device has also been validated and compared with other commercial systems obtaining similar results. In this way, based on the quality of the obtained signals and the low variability of the computed parameters, even in ambulatory conditions, the developed device can potentially serve as a support tool for clinical decision-taking stages.


Assuntos
Epilepsia , Fotopletismografia , Eletrocardiografia/métodos , Epilepsia/diagnóstico , Frequência Cardíaca/fisiologia , Humanos , Monitorização Ambulatorial , Pacientes Ambulatoriais , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador
2.
Sensors (Basel) ; 22(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36502071

RESUMO

Epileptic seizures have a great impact on the quality of life of people who suffer from them and further limit their independence. For this reason, a device that would be able to monitor patients' health status and warn them for a possible epileptic seizure would improve their quality of life. With this aim, this article proposes the first seizure predictive model based on Ear EEG, ECG and PPG signals obtained by means of a device that can be used in a static and outpatient setting. This device has been tested with epileptic people in a clinical environment. By processing these data and using supervised machine learning techniques, different predictive models capable of classifying the state of the epileptic person into normal, pre-seizure and seizure have been developed. Subsequently, a reduced model based on Boosted Trees has been validated, obtaining a prediction accuracy of 91.5% and a sensitivity of 85.4%. Thus, based on the accuracy of the predictive model obtained, it can potentially serve as a support tool to determine the status epilepticus and prevent a seizure, thereby improving the quality of life of these people.


Assuntos
Eletroencefalografia , Epilepsia , Humanos , Eletroencefalografia/métodos , Qualidade de Vida , Convulsões/diagnóstico , Epilepsia/diagnóstico , Aprendizado de Máquina
3.
Sensors (Basel) ; 21(7)2021 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-33810419

RESUMO

Endonasal surgery is a minimally invasive approach for the removal of pituitary tumors (sarcomas). In this type of procedure, the surgeon has to complete the surgical maneuvers for sarcoma resection with extreme precision, as there are many vital structures in this area. Therefore, the use of robots for this type of intervention could increase the success of the intervention by providing accurate movements. Research has focused on the development of teleoperated robots to handle a surgical instrument, including the use of virtual fixtures to delimit the working area. This paper aims to go a step further with a platform that includes a teleoperated robot and an autonomous robot dedicated to secondary tasks. In this way, the aim is to reduce the surgeon's workload so that he can concentrate on his main task. Thus, the article focuses on the description and implementation of a navigator that coordinates both robots via a force/position control. Finally, both the navigation and control scheme were validated by in-vitro tests.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Masculino
4.
Sensors (Basel) ; 19(19)2019 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-31590351

RESUMO

Blood pressure wave monitoring provides interesting information about the patient's cardiovascular function. For this reason, this article proposes a non-invasive device capable of capturing the vibrations (pressure waves) produced by the carotid artery by means of a pressure sensor encapsulated in a closed dome filled with air. When the device is placed onto the outer skin of the carotid area, the vibrations of the artery will exert a deformation in the dome, which, in turn, will lead to a pressure increase in its inner air. Then, the sensor inside the dome captures this pressure increase. By combining the blood pressure wave obtained with this device together with the ECG signal, it is possible to help the screening of the cardiovascular system, obtaining parameters such as heart rate variability (HRV) and pulse transit time (PTT). The results show how the pressure wave has been successfully obtained in the carotid artery area, discerning the characteristic points of this signal. The features of this device compare well with previous works by other authors. The main advantages of the proposed device are the reduced size, the cuffless condition, and the potential to be a continuous ambulatory device. These features could be exploited in ambulatory tests.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Monitorização Fisiológica , Análise de Onda de Pulso/métodos , Adulto , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Eletrocardiografia/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Fotopletismografia/métodos , Análise de Onda de Pulso/instrumentação , Transdutores
5.
Biosensors (Basel) ; 14(5)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38785725

RESUMO

Peripheral artery disease (PAD) is a common circulatory disorder characterized by the accumulation of fats, cholesterol, and other substances in the arteries that restrict blood flow to the extremities, especially the legs. The ankle brachial index (ABI) is a highly reliable and valid non-invasive test for diagnosing PAD. However, the traditional method has limitations. These include the time required, the need for Doppler equipment, the training of clinical staff, and patient discomfort. PWV refers to the speed at which an arterial pressure wave propagates along the arteries, and this speed is conditioned by arterial elasticity and stiffness. To address these limitations, we have developed a system that uses electrocardiogram (ECG) and photoplethysmography (PPG) signals to calculate pulse wave velocity (PWV). We propose determining the ABI based on this calculation. Validation was performed on 22 diabetic patients, and the results demonstrate the accuracy of the system, maintaining a margin of ±0.1 compared with the traditional method. This confirms the correlation between PWV and ABI and positions this technique as a promising alternative to overcome some of the limitations of the conventional method.


Assuntos
Índice Tornozelo-Braço , Fotopletismografia , Análise de Onda de Pulso , Humanos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Eletrocardiografia , Masculino , Feminino , Pessoa de Meia-Idade
6.
Biosensors (Basel) ; 14(3)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38534256

RESUMO

A proof-of-concept of a microwave imaging system for the fast detection of abdominal aortic aneurysms is shown. This experimental technology seeks to overcome the factors hampering the fast screening for these aneurysms with the usual equipment, such as high cost, long-time operation or hazardous exposure to chemical substances. The hardware system is composed of 16 twin antennas mastered by a microcontroller through a switching network, which connects the antennas to the measurement instrument for sequential measurement. The software system is run by a computer, mastering the whole system, automatizing the measurement process and running the signal processing and medical image generation algorithms. Two image generation algorithms are tested: Delay-and-Sum (DAS) and Improved Delay-and-Sum (IDAS). Own-modified versions of these algorithms adapted to the requirements of our system are proposed. The system is carefully calibrated and fine-tuned with known objects placed at known distances. An experimental proof-of-concept is shown with a human torso phantom, including an aorta phantom and an aneurysm phantom placed in different positions. The results show good imaging capabilities with the potential for detecting and locating possible abdominal aortic aneurysms and reporting acceptable errors.


Assuntos
Aneurisma da Aorta Abdominal , Imageamento de Micro-Ondas , Humanos , Aneurisma da Aorta Abdominal/diagnóstico , Software , Algoritmos , Imagens de Fantasmas
7.
Biosensors (Basel) ; 13(7)2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37504116

RESUMO

The heart rate (HR) is a widely used clinical variable that provides important information on a physical user's state. One of the most commonly used methods for ambulatory HR monitoring is photoplethysmography (PPG). The PPG signal retrieved from wearable devices positioned on the user's wrist can be corrupted when the user is performing tasks involving the motion of the arms, wrist, and fingers. In these cases, the obtained HR is altered as well. This problem increases when trying to monitor people with autism spectrum disorder (ASD), who are very reluctant to use foreign bodies, notably hindering the adequate attachment of the device to the user. This work presents a machine learning approach to reconstruct the user's HR signal using an own monitoring wristband especially developed for people with ASD. An experiment is carried out, with users performing different daily life activities in order to build a dataset with the measured signals from the monitoring wristband. From these data, an algorithm is applied to obtain a reliable HR value when these people are performing skill improvement activities where intensive wrist movement may corrupt the PPG.


Assuntos
Transtorno do Espectro Autista , Fotopletismografia , Humanos , Frequência Cardíaca/fisiologia , Fotopletismografia/métodos , Artefatos , Processamento de Sinais Assistido por Computador , Movimento (Física) , Algoritmos
8.
Med Biol Eng Comput ; 57(11): 2389-2405, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31473945

RESUMO

Self-management of blood glucose level is part and parcel of diabetes treatment, which involves invasive, painful, and uncomfortable methods. A proper non-invasive blood glucose monitor (NIBGM) is therefore desirable to deal better with it. Microwave resonators can potentially be used for such a purpose. Following the positive results from an in vitro previous work, a portable device based upon a microwave resonator was developed and assessed in a multicenter proof of concept. Its electrical response was analyzed when an individual's tongue was placed onto it. The study was performed with 352 individuals during their oral glucose tolerance tests, having four measurements per individual. The findings revealed that the accuracy must be improved before the diabetes community can make real use of the device. However, the relationship between the measuring parameter and the individual's blood glucose level is coherent with that from previous works, although with higher data dispersion. This is reflected in correlation coefficients between glycemia and the measuring magnitude consistently negative, although small, for the different datasets analyzed. Further research is proposed, focused on system improvements, individual calibration, and multitechnology approach. The study of the influence of other blood components different to glucose is also advised. Graphical abstract.


Assuntos
Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Adulto , Calibragem , Desenho de Equipamento , Estudos de Viabilidade , Teste de Tolerância a Glucose , Humanos , Micro-Ondas , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Língua/química , Adulto Jovem
9.
Artif Intell Med ; 78: 55-60, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28764873

RESUMO

BACKGROUND AND OBJECTIVES: On occasions, a surgical intervention can be associated with serious, potentially life-threatening complications. One of these complications is a haemorrhage during the operation, an unsolved issue that could delay the intervention or even cause the patient's death. On laparoscopic surgery this complication is even more dangerous, due to the limited vision and mobility imposed by the minimally invasive techniques. METHODS: In this paper it is described a computer vision algorithm designed to analyse the images captured by a laparoscopic camera, classifying the pixels of each frame in blood pixels and background pixels and finally detecting a massive haemorrhage. The pixel classification is carried out by comparing the parameter B/R and G/R of the RGB space colour of each pixel with a threshold obtained using the global average of the whole frame of these parameters. The detection of and starting haemorrhage is achieved by analysing the variation of the previous parameters and the amount of pixel blood classified. RESULTS: When classifying in vitro images, the proposed algorithm obtains accuracy over 96%, but during the analysis of an in vivo images obtained from real operations, the results worsen slightly due to poor illumination, visual interferences or sudden moves of the camera, obtaining accuracy over 88%. The detection of haemorrhages directly depends of the correct classification of blood pixels, so the analysis achieves an accuracy of 78%. CONCLUSIONS: The proposed algorithm turns out to be a good starting point for an automatic detection of blood and bleeding in the surgical environment which can be applied to enhance the surgeon vision, for example showing the last frame previous to a massive haemorrhage where the incision could be seen using augmented reality capabilities.


Assuntos
Algoritmos , Perda Sanguínea Cirúrgica , Hemorragia/diagnóstico , Processamento de Imagem Assistida por Computador , Laparoscopia/efeitos adversos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA