Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Klin Monbl Augenheilkd ; 241(4): 392-397, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38653293

RESUMO

PURPOSE: To introduce a novel technique of the aseptic manufacture of autologous serum eye drops (ASEDs) with a prefiltered closed system and to analyze the sterility of the produced ophtioles between 2018 and 2022. METHODS: This is a prospective single-center study conducted at the Department of Ophthalmology at a Swiss University Hospital between 2018 and 2022. For regulatory reasons, closed systems for manufacturing ASEDs are strongly recommended. We attached an upstream sterile filter (Sterivex PES0.22 µm Burlington, USA) to a commercially available closed system (COL System Modena, Italy) for manufacturing ASEDs. The goal of this novel approach was to reduce the microbiological contamination of the donated autologous blood. Using the presented manufacturing method, we are able to produce, on average, 56 ophtioles per batch, containing either 1.45 mL or 2.5 mL of autologous serum per ophtiole. For each batch of ASEDs, we performed a microbiological analysis by automated blood culture testing (BACTEC). This system examines the presence of bacteria and fungi. RESULTS: We analyzed all manufactured batches between 2018 and 2022. None of the 2297 batches and the resulting 129 060 ophtioles showed bacterial or mycotic contamination. During the analyzed period, two batches were discarded: one due to fibrin-lipid aggregations, further microbiological and histological work-up excluded any contamination; another due to false-positive HIV in serological testing. Overall, the contamination rate was 0%, and the batch discharge rate was 0.09%. CONCLUSIONS: The combination of upstream sterile filtration with a commercial closed system for manufacturing ASEDs proved to be effective in ensuring sterility without any contamination over the past 4 years. This is becoming crucial, as the demand for autologous blood products for treating ocular surface disorders, such as refractory dry eyes or nonhealing defects of the corneal epithelium, is on the rise.


Assuntos
Contaminação de Medicamentos , Soluções Oftálmicas , Soro , Humanos , Contaminação de Medicamentos/prevenção & controle , Estudos Prospectivos , Esterilização/métodos , Assepsia/métodos
2.
Klin Monbl Augenheilkd ; 241(4): 412-416, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38653295

RESUMO

PURPOSE: To establish a national consensus on contraindications for corneal donation for transplantation in Switzerland. METHODS: Swisstransplant (SWT), the Swiss national foundation coordinating tissue and organ donations, convened a working group consisting of six national corneal surgeons and eye bankers and donation experts to create a contraindication list for corneal donation. The group reviewed available national and international guidelines and recommendations, while adhering to Swiss law and transplant regulations. In cases of opposing opinions, the group held follow-up meetings until a consensus was reached. A consensus was defined as agreement among all parties present. RESULTS: From March 2021 to November 2021, the study group held six meetings and created a standardized minimal contraindication list for corneal donation in Switzerland. Thanks to this list, SWT has created a mandatory working and documentation file for donor coordinators to use when evaluating multiorgan donors for corneal harvesting. The authors agreed that while the national consensus list provides standardized minimal contraindication criteria, local eye banks may choose to introduce additional, more rigorous criteria. CONCLUSION: Given that corneal transplantation is the most commonly performed transplantation, establishing a consensus on contraindications is crucial for recipient safety. The creation of a consensus on contraindications for corneal donation in Switzerland is an essential contribution to fulfil the legal requirements concerning quality assurance and provides sufficient high-quality donor tissue within the country. Therefore, periodic review and revision of the consensus is considered critical.


Assuntos
Transplante de Córnea , Obtenção de Tecidos e Órgãos , Suíça , Transplante de Córnea/legislação & jurisprudência , Humanos , Obtenção de Tecidos e Órgãos/legislação & jurisprudência , Doadores de Tecidos/legislação & jurisprudência , Consenso , Bancos de Olhos/legislação & jurisprudência , Contraindicações de Procedimentos
3.
Klin Monbl Augenheilkd ; 241(4): 441-444, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38653296

RESUMO

PURPOSE: To evaluate the increase in retinal thickness as a marker in predicting the onset of central retinal artery occlusions. METHODS: Retrospective clinical study conducted at one Swiss hospital. Electronic records were filtered for patients with artery occlusions. Optical coherence tomography data, including time between the imaging and ischemic event, were reviewed. Increase in relative retinal thickness was measured, defined as an increase in retinal thickness compared to the unaffected partner eye. This was correlated with the time from symptom onset. A cutoff value of relative increase of < 24.5% was applied, as suggested in previous studies. The results were compared to the time gathered from the electronic records, and sensitivity, specificity, positive predictive value as well as negative predictive value were calculated for predicting an ischemia time of < 4.5 h. RESULTS: Forty-two eyes from 41 patients with central artery occlusions were identified. Fourteen were female. Mean age was 66.4 ± 15.8 years. Initial corrected visual acuity was 2.41 ± 0.68 logMAR, and 2.13 ± 0.87 logMAR at the last follow-up (p > 0.05). Of eyes with a visual acuity of counting fingers (n = 38) or worse, 89.5% showed no improvement during follow-up, while eyes with logMAR 1 or better (n = 4) improved. Thirteen eyes (13 patients) presented within 4.5 h of the ischemic event. Four patients received i. v. thrombolysis, with visual recovery in one. In 12 eyes with an ischemia time of < 4.5 h, relative increase was below 24.5%. In the remaining 29 eyes with > 4.5 h, relative increase was below 24.5% in 4 eyes and above 24.5% in 25 eyes. This yielded a sensitivity of 92.3%, a specificity of 86.2%, with a positive predictive value of 75.0% and a negative predictive value of 96.2%. CONCLUSION: Central retinal artery occlusion is associated with severe vision loss. There is no current established therapy. Parameters that objectify the presence of a therapeutic window for thrombolysis are gaining in importance as patient history is often imprecise. Relative retinal thickness increase proved a noninvasive imaging parameter demonstrating adequate performance in detecting patients within the therapeutic window of thrombolysis. Further investigation of this parameter in central retinal occlusion is warranted.


Assuntos
Oclusão da Artéria Retiniana , Sensibilidade e Especificidade , Tomografia de Coerência Óptica , Humanos , Oclusão da Artéria Retiniana/diagnóstico por imagem , Feminino , Masculino , Idoso , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Retina/diagnóstico por imagem , Retina/patologia , Tamanho do Órgão , Idoso de 80 Anos ou mais
4.
Klin Monbl Augenheilkd ; 241(4): 477-481, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38653298

RESUMO

BACKGROUND: To report ophthalmological outcomes and treatment regimen in patients with Susac syndrome. METHODS: This is a retrospective analysis of patients with Susac syndrome treated between November 2015 and March 2023. Multimodal imaging findings, ophthalmic examination data, information on neurological and sensorineural involvement, and therapeutic regimen were reviewed. Visual acuity was recorded as the logarithm of the minimum angle of resolution (logMAR). Ophthalmological manifestations and disease severity were assessed using the previously described clinical activity score (CAS). RESULTS: Ten patients with Susac syndrome m : f = 5 : 5 were identified. The mean follow-up time was 31.2 ± 23.3 months (range 1 to 78 months). The mean age was 41.4 ± 13.8 years (range 21 to 59 years). At baseline, corrected distance visual acuity (CDVA) was 0.03 ± 0.08 logMAR. At the last follow-up, CDVA improved to 0.00 ± 0.03 logMAR (p = 0.029). Three of 20 eyes showed an improvement of 5 letters, while no loss of visual acuity was recorded during the follow-up time. Baseline CAS was 10.65 ± 12.69, and CAS at the last follow-up was 5.15 ± 5.49 (p = 0.068). Except for one patient, all were initially treated with intravenous (i. v.) steroids and subsequent oral tapering. Depending on the treatment response, cyclophosphamide (n = 4), i. v. immunoglobulins (IVIGs) (n = 4), anti-CD20 antibodies (n = 3), or plasmapheresis (n = 1) were applied. All patients under treatment for more than 1 month (n = 9) showed improvement in CAS and CDVA. CONCLUSION: Susac syndrome is a rare autoimmune vascular endotheliopathy. Treatment of Susac syndrome appears to result in improving CAS and CDVA. The majority of patients, in addition to the systemic steroids, required systemic immunosuppressive agents. Interdisciplinary communication is crucial to reduce the time to diagnosis and initiation of therapy in patients with Susac syndrome.


Assuntos
Síndrome de Susac , Acuidade Visual , Humanos , Síndrome de Susac/complicações , Síndrome de Susac/diagnóstico , Síndrome de Susac/terapia , Síndrome de Susac/tratamento farmacológico , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem , Resultado do Tratamento , Imunossupressores/uso terapêutico , Seguimentos
5.
Klin Monbl Augenheilkd ; 240(4): 369-378, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37164391

RESUMO

PURPOSE: To present a case series of rare and severe complications after corneal collagen cross-linking (CXL) of keratoconus patients. METHODS: Single-center descriptive case series covering the period of 2012 to 2022 at the Department of Ophthalmology at the University Hospital, Zurich, Switzerland. RESULTS: We present four eyes of four patients that showed severe unusual complications within the first month after CXL. Three patients had been treated with the classical epithelium-off "Dresden" protocol. One patient had been treated with the accelerated epithelium-off protocol. One patient presented with extensive corneal edema due to rubbing the eye after treatment. Two patients showed a bacterial infectious keratitis: one due to Streptococcus pneumoniae and the other due to Staphylococcus hominis, Micrococcus luteus, and Streptococcus epidermidis. The latter of the two patients exhibited extensive infectious crystalline keratopathy. The fourth patient showed a severe ulcerative lesion where no infectious cause could be found. Therefore, an autoimmune keratolytic process had to be suspected. Apart from the corneal edema, which resolved ad integrum, the other complications resulted in permanent corneal scarring and thinning. One patient needed an emergency amniotic transplant. CONCLUSION: Severe complications after CXL remain rare. Most common causes are complications that are not directly associated with the treatment as such. Those indirect complications occur after the treatment during the healing course of the epithelium. Associations with bandage contact lenses, topical steroids, atopic disease, and inappropriate patient behavior are often suspected. Correctly performed corneal scrapings with repeated microbiological analysis and a detailed patient history are essential for establishing the correct diagnosis, especially in complicated cases that do not respond to a standard therapeutic regimen. This case series supports the efforts that are currently taken to improve the CXL technique in a way that postoperative complications are further reduced. A more efficient epithelium-on technique might be a step in that direction.


Assuntos
Crosslinking Corneano , Ceratocone , Humanos , Crosslinking Corneano/efeitos adversos , Ceratocone/complicações , Ceratocone/terapia , Resultado do Tratamento , Ceratite/microbiologia , Edema da Córnea , Masculino , Criança , Adolescente , Adulto
6.
Klin Monbl Augenheilkd ; 240(4): 608-612, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37164413

RESUMO

PURPOSE: To assess optic nerve head (ONH) and macular blood flow in young healthy volunteers using laser speckle flowgraphy (LSFG). METHODS: This is a prospective single-center study conducted at the Department of Ophthalmology, University Hospital Zurich from May to November 2021. Young, healthy men aged ≥ 18 years without ocular or systemic diseases were included. A corrected visual acuity (VA) of 0.0 logMAR or better in both eyes and an intraocular pressure (IOP) of 21 mmHg or lower were required for inclusion. Subjects exceeding a spherical equivalent (SE) of ± 6 diopters (dpt) were excluded. Blood flow in the macula and the ONH was recorded using the Nidek LSFG RetFlow device (Nidek Company, Ltd., Hirioshi-cho, Japan). Laser power was set to 0.5 Millivolts (mV). Mean blur rate (MBR) was recorded as a parameter for blood flow. MBR is a calculated parameter that represents relative blood flow velocity correlated with the real anatomical blood flow rate. Colored heat maps of the recorded retinal area were generated automatically by the RetFlow device. RESULTS: Final analyses included 83 eyes of 43 male volunteers. Mean age was 21.9 years (SD ± 1.5, range: 20 to 29). Mean corrected VA was - 0.1 logMAR (SD ± 0.05, range: - 0.2 to 0.0), mean IOP was 15.4 mmHg (SD ± 2.5, range: 8.5 to 18.5), and mean SE was - 0.3 dpt (SD ± 1.2, range: - 5.0 to 1.2). Mean ONH MBR was 37.44 (SD ± 7.9, range: 22.5 to 53.5) and mean macular MBR was 27.8 (SD ± 9.7, range: 6.4 to 57.7). Pearson's Test showed a strong correlation between macular and papillary blood flow (p < 0.05, coefficient: 0.647). CONCLUSION: This study provides both ONH and macular blood flow data in a healthy young male population, showing a strong correlation between ONH and macular blood flow in the examined eyes. Further investigations are required to assess the validity of MBR as a parameter for the combined evaluation of retinal blood flow at the macula and ONH in healthy volunteers and patients with various diseases.


Assuntos
Disco Óptico , Humanos , Masculino , Adulto Jovem , Adulto , Disco Óptico/diagnóstico por imagem , Disco Óptico/irrigação sanguínea , Voluntários Saudáveis , Estudos Prospectivos , Fluxo Sanguíneo Regional/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Lasers
7.
Klin Monbl Augenheilkd ; 240(4): 516-521, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37164408

RESUMO

BACKGROUND: Solar and laser-associated retinopathies are rare occurrences. The two retinopathies are both photo-induced but differ in the involved intensity and duration of exposure. The purpose of this study was to evaluate the clinical features and natural course of these two entities, with a focus on the changes in the outer retina over time. PATIENTS AND METHODS: This retrospective analysis assessed patients with solar or laser maculopathy seen at the Department of Ophthalmology of the University Hospital Zurich in Switzerland over the last 10 years. Visual acuity (VA; Snellen) and optical coherence tomography (OCT) findings were reviewed and analyzed at baseline and last follow-up visit. Areas of damaged outer retina, identified on en face OCT images as hyporeflective areas, were tagged and compared between visits. Descriptive analysis was performed by calculating mean values ± standard deviation (SD). Statistical evaluation was done using the Wilcoxon signed rank test. A p value < 0.05 was considered statistically significant. RESULTS: Five patients with solar retinopathy and six patients with laser-associated retinopathy were identified. In the solar retinopathy group, mean VA at baseline was 0.80 (SD ± 0.37) and improved to 0.90 (SD ± 0.36). This was not statistically significant (p = 0.066). In the laser-associated retinopathy group, mean VA at baseline was 0.89 (SD ± 0.18) and improved to 1.03 (SD ± 0.09), which was not statistically significant either (p = 0.063). At baseline, in OCT cross-sections, initial changes were observed in the interdigitation, myoid, and ellipsoid zone, as well as the outer nuclear layer and the Henle fiber layer. At follow-up, most cases presented an alteration in the residual ellipsoid zone, with the degree of the aforementioned alterations depending on the size of the initial defect. A decrease of the hyporeflective alterations measured in en face OCT scans was observed in both groups but was only statistically significant in the laser-associated retinopathy group (p = 0.018 versus p = 0.172). CONCLUSIONS: OCT can help to detect and monitor solar and laser-associated retinal injuries. Most injuries are minor, with good functional restitution. Minor changes in the ellipsoid zone often persist, even in cases with full visual recovery.


Assuntos
Retina , Degeneração Retiniana , Humanos , Estudos Retrospectivos , Suíça/epidemiologia , Retina/diagnóstico por imagem , Atenção Primária à Saúde , Hospitais , Tomografia de Coerência Óptica/métodos
8.
BMC Anesthesiol ; 22(1): 167, 2022 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-35637450

RESUMO

BACKGROUND: Cognitive ergonomics design of patient monitoring may reduce human factor errors in high-stress environments. Eye-tracking is a suitable tool to gain insight into the distribution of visual attention of healthcare professionals with patient monitors, which may facilitate their further development. METHODS: This prospective, exploratory, high-fidelity simulation study compared anesthesia personnel's visual attention (fixation count and dwell-time) to 15 areas of interest on the patient monitor during non-critical and critical anesthesia situations. Furthermore, we examined the extent to which participants' experience influenced visual attention and which vital signs displayed on the patient monitor received the most visual attention. We used mixed zero-inflated Poisson regression and mixed linear models to analyze the data. RESULTS: Analyzing 23 ten-minute scenarios, we found significantly more fixations to the areas of interest on the patient monitor during critical than non-critical situations (rate ratio of 1.45; 95% CI 1.33 to 1.59; p < 0.001). However, the dwell-time on the areas of interest did not significantly differ between the non-critical and critical situations (coefficient of - 1.667; 95% CI - 4.549 to 1.229; p = 0.27). The professional experience did not significantly influence the visual attention (fixation: rate ratio of 0.88; 95% CI 0.54 to 1.43; p = 0.61 and dwell-time: coefficient of 0.889; 95% CI - 1.465 to 3.229; p = 0.27). Over all situations, anesthesia personnel paid the most attention to the vital signs blood pressure (fixation: mean [SD] of 108 [74.83]; dwell-time: mean [SD] of 27 [15.90] seconds), end-expiratory carbon dioxide (fixation: mean [SD] of 59 [47.39]; dwell-time: mean [SD] of 30 [21.51] seconds), and the electrocardiogram (fixation: mean [SD] of 58 [64.70]; dwell-time: mean [SD] of 15 [14.95] seconds). CONCLUSIONS: Critical anesthesia situations increased anesthesia personnel's visual interaction with the patient monitor. Furthermore, we found that their visual attention focused mainly on a few vital signs. To assist clinicians in critical situations, manufacturers should optimize monitors to convey necessary information as easily and quickly as possible and optimize the visibility of less frequently observed but equally critical vital signs, especially when they are in an abnormal range.


Assuntos
Anestesia , Anestesiologia , Tecnologia de Rastreamento Ocular , Humanos , Monitorização Fisiológica , Estudos Prospectivos
9.
Ergonomics ; 65(10): 1326-1337, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35023811

RESUMO

Acute bleeding during surgery or after trauma harms patients, and challenges involved physicians. Protocols and cognitive aids can help in such situations. This dual-centre study investigated physicians' opinions regarding two ways to present cognitive aids, graphic 'Haemostasis Traffic Light' and text-based, using the example of a coagulation management algorithm to identify the strengths and limitations of both presentation modalities. Using qualitative research methods, we identified recurring answer patterns and derived major topics and subthemes through inductive coding. Eighty-four physicians participated. We assigned each half randomly to one of the cognitive aids (graphic/text-based) and determined 447 usable statements. We qualitatively deduced the importance of having a cognitive aid for physicians. Furthermore, it is noticeable that the graphic group made more positive comments (154 of 242 (64%) statements), while the text-based participants made more negative annotations (126 of 205 (61%) statements), suggesting a generally stronger approval of this cognitive aid. Practitioner summary: This qualitative study provides an overview of physicians` positive and negative perceptions regarding two presentation ways for a coagulation management algorithm. Participants perceived the graphic method created according to user-centred design principles more positively. The analysis reveals components that an ideal algorithm should have to help streamline the decision-making process.


Assuntos
Recursos Audiovisuais , Médicos , Algoritmos , Humanos , Pesquisa Qualitativa
10.
N Engl J Med ; 389(4): e6, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37486778
11.
Br J Anaesth ; 127(5): 769-777, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34454710

RESUMO

BACKGROUND: Acoustic alarms in medical devices are vital for patient safety. State-of-the-art patient monitoring alarms are indistinguishable and contribute to alarm fatigue. There are two promising new sound modalities for vital sign alarms. Auditory icons convey alarms as brief metaphorical sounds, and voice alerts transmit information using a clear-spoken language. We compared how reliably healthcare professionals identified alarms using these two modalities. METHODS: This investigator-initiated computer-based multicentre simulation study included 28 anaesthesia providers who were asked to identify vital sign alarms in randomised order, once with voice alerts and once with auditory icons. We further assessed time to decision, diagnostic confidence, and perceived helpfulness. We analysed the results using mixed models, adjusted for possible confounders. RESULTS: We assessed 14 alarms for each modality, resulting in 392 comparisons across all participants. Compared with auditory icons, healthcare providers had 58 times higher odds of correctly identifying alarms using voice alerts (odds ratio 58.0; 95% confidence interval [CI]: 25.1-133.6; P<0.001), made their decisions about 14 s faster (coefficient -13.9; 95% CI: -15.8 to -12.1 s; P<0.001), perceived higher diagnostic confidence (100% [392 of 392] vs 43% [169 of 392; P<0.001]), and rated voice alerts as more helpful (odds ratio 138.2; 95% CI: 64.9-294.1; P<0.001). The participants were able to identify significantly higher proportions of alarms with voice alerts (98.5%; P<0.001) and auditory icons (54.1%; P<0.001) compared with state-of-the-art alarms (17.9%). CONCLUSIONS: Voice alerts were superior to auditory icons, and both were superior to current state-of-the-art auditory alarms. These findings demonstrate the potential that voice alerts hold for patient monitoring.


Assuntos
Acústica , Alarmes Clínicos , Monitorização Fisiológica/métodos , Voz , Adulto , Percepção Auditiva , Simulação por Computador , Tomada de Decisões , Desenho de Equipamento , Feminino , Pessoal de Saúde/estatística & dados numéricos , Humanos , Masculino , Fatores de Tempo
12.
Br J Anaesth ; 126(5): 1046-1054, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33879327

RESUMO

BACKGROUND: Failures in situation awareness cause two-thirds of anaesthesia complications. Avatar-based patient monitoring may promote situation awareness in critical situations. METHODS: We conducted a prospective, randomised, high-fidelity simulation study powered for non-inferiority. We used video analysis to grade anaesthesia teams managing three 10 min emergency scenarios using three randomly assigned monitoring modalities: only conventional, only avatar, and split-screen showing both modalities side by side. The primary outcome was time to performance of critical tasks. Secondary outcomes were time to verbalisation of vital sign deviations and the correct cause of the emergency, perceived workload, and usability. We used mixed Cox and linear regression models adjusted for various potential confounders. The non-inferiority margin was 10%, or hazard ratio (HR) 0.9. RESULTS: We analysed 52 teams performing 154 simulations. For performance of critical tasks during a scenario, split-screen was non-inferior to conventional (HR=1.13; 95% confidence interval [CI], 0.96-1.33; not significant in test for superiority); the result for avatar was inconclusive (HR=0.98; 95% CI, 0.83-1.15). Avatar was associated with a higher probability for verbalisation of the cause of the emergency (HR=1.78; 95% CI, 1.13-2.81; P=0.012). We found no evidence for a monitor effect on perceived workload. Perceived usability was lower for avatar (coefficient=-23.0; 95% CI, -27.2 to -18.8; P<0.0001) and split-screen (-6.7; 95% CI, -10.9 to -2.4; P=0.002) compared with conventional. CONCLUSIONS: This study showed non-inferiority of split-screen compared with conventional monitoring for performance of critical tasks during anaesthesia crisis situations. The patient avatar improved verbalisation of the correct cause of the emergency. These results should be interpreted considering participants' minimal avatar but extensive conventional monitoring experience.


Assuntos
Anestesia/métodos , Treinamento com Simulação de Alta Fidelidade/métodos , Monitorização Intraoperatória/métodos , Interface Usuário-Computador , Anestesia/efeitos adversos , Conscientização , Feminino , Humanos , Masculino , Estudos Prospectivos , Carga de Trabalho
13.
BMC Anesthesiol ; 21(1): 43, 2021 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-33568050

RESUMO

BACKGROUND: Acute bleeding is an omnipresent challenge for all physicians. Uncontrolled hemorrhage is the most common preventable cause of death after trauma worldwide. In different surgical disciplines, hemorrhage represents an independent risk factor for increased postoperative morbimortality, directly affecting patients' outcomes. This study asked anesthesiologists about their personal perceived challenges when treating bleeding patients. METHODS: This investigator-initiated, prospective, international, dual-center, mixed qualitative and quantitative study interrogated anesthesiologists about what they found easy and what difficult in treating acutely bleeding patients. Following the template approach for qualitative research, we identified major and minor topics through free inductive coding and word count. In a second step, we derived ten statements from the participants' answers. Using a field survey, we then asked the participants to rate their level of agreement with the derived statements. We analyzed the answers using one sample Wilcoxon test and the Mann-Whitney test. RESULTS: We included a total of 84 physicians in the qualitative interrogations and a different group of 42 anesthesiologists in the quantitative part. We identified 11 major topics and 19 associated subtopics. The main topics and the degree of agreement (here as agree or strongly agree) were as follows: "Complexity of the topic" (52.4% agreed to find the topic complex), "Cognitive aids" (92.9% agreed to find them helpful), "Time management" (64.3% agreed to feeling time pressure), "Human factors" (95.2% agreed that human factors are essential), "Resources" (95.2% agreed that resources are essential), "Experience" and "Low frequency of cases" (57.1% agreed to lack practice), "Diagnostic methods" (31.0% agreed that the interpretation of test results is difficult), "Anticoagulation" (85.7% agreed to it being difficult), "Treatment" (81.0% agreed to knowing the first therapeutic steps), and "Nothing". CONCLUSIONS: Anesthesiologists in two large tertiary care facilities in different parts of the world found coagulation management, especially in anticoagulated patients, complex. We identified the delayed diagnostic test results and their interpretation as challenges. Resources, treatment protocols and human factors such as team communication were perceived to facilitate management. Future studies should explore the challenges in smaller hospitals and other parts of the world and test new technologies addressing the identified difficulties.


Assuntos
Anestesiologistas/estatística & dados numéricos , Atitude do Pessoal de Saúde , Hemorragia/terapia , Inquéritos e Questionários/estatística & dados numéricos , Doença Aguda , Anestesiologistas/psicologia , Argentina , Hemorragia/psicologia , Humanos , Médicos/estatística & dados numéricos , Estudos Prospectivos , Pesquisa Qualitativa , Suíça
14.
J Med Internet Res ; 23(5): e27124, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-33843602

RESUMO

BACKGROUND: Viscoelastic test-guided coagulation management has become increasingly important in assessing hemostasis. We developed Visual Clot, an animated, 3D blood clot that illustrates raw rotational thromboelastometry (ROTEM) parameters in a user-centered and situation awareness-oriented method. OBJECTIVE: This study aimed to evaluate the applicability of Visual Clot by examining its effects on users that are novices in viscoelastic-guided resuscitation. METHODS: We conducted an investigator-initiated, international, multicenter study between September 16, 2020, and October 6, 2020, in 5 tertiary care hospitals in central Europe. We randomly recruited medical students and inexperienced resident physicians without significant prior exposure to viscoelastic testing. The 7 participants per center managed 9 different ROTEM outputs twice, once as standard ROTEM tracings and once as the corresponding Visual Clot. We randomly presented the 18 viscoelastic cases and asked the participants for their therapeutic decisions. We assessed the performance, diagnostic confidence, and perceived workload in managing the tasks using mixed statistical models and adjusted for possible confounding factors. RESULTS: Analyzing a total of 630 results, we found that the participants solved more cases correctly (odds ratio [OR] 33.66, 95% CI 21.13-53.64; P<.001), exhibited more diagnostic confidence (OR 206.2, 95% CI 93.5-454.75; P<.001), and perceived less workload (coefficient -41.63; 95% CI -43.91 to -39.36; P<.001) using Visual Clot compared to using standard ROTEM tracings. CONCLUSIONS: This study emphasizes the practical benefit of presenting viscoelastic test results in a user-centered way. Visual Clot may allow inexperienced users to be involved in the decision-making process to treat bleeding-associated coagulopathy. The increased diagnostic confidence, diagnostic certainty, reduced workload, and positive user feedback associated with this visualization may promote the further adoption of viscoelastic methods in diverse health care settings.


Assuntos
Transtornos da Coagulação Sanguínea , Trombose , Hemostasia , Humanos , Tecnologia , Tromboelastografia
15.
J Med Internet Res ; 22(9): e19472, 2020 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-32780712

RESUMO

BACKGROUND: Patient monitoring is indispensable in any operating room to follow the patient's current health state based on measured physiological parameters. Reducing workload helps to free cognitive resources and thus influences human performance, which ultimately improves the quality of care. Among the many methods available to assess perceived workload, the National Aeronautics and Space Administration Task Load Index (NASA-TLX) provides the most widely accepted tool. However, only few studies have investigated the validity of the NASA-TLX in the health care sector. OBJECTIVE: This study aimed to validate a modified version of the raw NASA-TLX in patient monitoring tasks by investigating its correspondence with expected lower and higher workload situations and its robustness against nonworkload-related covariates. This defines criterion validity. METHODS: In this pooled analysis, we evaluated raw NASA-TLX scores collected after performing patient monitoring tasks in four different investigator-initiated, computer-based, prospective, multicenter studies. All of them were conducted in three hospitals with a high standard of care in central Europe. In these already published studies, we compared conventional patient monitoring with two newly developed situation awareness-oriented monitoring technologies called Visual Patient and Visual Clot. The participants were resident and staff anesthesia and intensive care physicians, and nurse anesthetists with completed specialization qualification. We analyzed the raw NASA-TLX scores by fitting mixed linear regression models and univariate models with different covariates. RESULTS: We assessed a total of 1160 raw NASA-TLX questionnaires after performing specific patient monitoring tasks. Good test performance and higher self-rated diagnostic confidence correlated significantly with lower raw NASA-TLX scores and the subscores (all P<.001). Staff physicians rated significantly lower workload scores than residents (P=.001), whereas nurse anesthetists did not show any difference in the same comparison (P=.83). Standardized distraction resulted in higher rated total raw NASA-TLX scores (P<.001) and subscores. There was no gender difference regarding perceived workload (P=.26). The new visualization technologies Visual Patient and Visual Clot resulted in significantly lower total raw NASA-TLX scores and all subscores, including high self-rated performance, when compared with conventional monitoring (all P<.001). CONCLUSIONS: This study validated a modified raw NASA-TLX questionnaire for patient monitoring tasks. The scores obtained correctly represented the assumed influences of the examined covariates on the perceived workload. We reported high criterion validity. The NASA-TLX questionnaire appears to be a reliable tool for measuring subjective workload. Further research should focus on its applicability in a clinical setting.


Assuntos
Monitorização Fisiológica/normas , Análise e Desempenho de Tarefas , Carga de Trabalho/psicologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Inquéritos e Questionários , Suíça , Carga de Trabalho/normas
16.
Sensors (Basel) ; 20(7)2020 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-32283625

RESUMO

Visual Patient technology is a situation awareness-oriented visualization technology that translates numerical and waveform patient monitoring data into a new user-centered visual language. Vital sign values are converted into colors, shapes, and rhythmic movements-a language humans can easily perceive and interpret-on a patient avatar model in real time. In this review, we summarize the current state of the research on the Visual Patient, including the technology, its history, and its scientific context. We also provide a summary of our primary research and a brief overview of research work on similar user-centered visualizations in medicine. In several computer-based studies under various experimental conditions, Visual Patient transferred more information per unit time, increased perceived diagnostic certainty, and lowered perceived workload. Eye tracking showed the technology worked because of the way it synthesizes and transforms vital sign information into new and logical forms corresponding to the real phenomena. The technology could be particularly useful for improving situation awareness in settings with high cognitive demand or when users must make quick decisions. This comprehensive review of Visual Patient research is the foundation for an evaluation of the technology in clinical applications, starting with a high-fidelity simulation study in early 2020.


Assuntos
Monitorização Fisiológica/métodos , Conscientização , Movimentos Oculares , Frequência Cardíaca , Humanos , Reconhecimento Automatizado de Padrão , Taxa Respiratória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA