RESUMO
BACKGROUND: The increasing incidence of coeliac disease is leading to a growing interest in active search for associated factors, even the intrauterine and early life. The exposome approach to disease encompasses a life course perspective from conception onwards has recently been highlighted. Knowledge of early exposure to gluten immunogenic peptides (GIP) in utero could challenge the chronology of early prenatal tolerance or inflammation, rather than after the infant's solid diet after birth. METHODS: We developed an accurate and specific immunoassay to detect GIP in amniotic fluid (AF) and studied their accumulates, excretion dynamics and foetal exposure resulting from AF swallowing. One hundred twenty-five pregnant women with different gluten diets and gestational ages were recruited. RESULTS: GIP were detectable in AF from at least the 16th gestational week in gluten-consuming women. Although no significant differences in GIP levels were observed during gestation, amniotic GIP late pregnancy was not altered by maternal fasting, suggesting closed-loop entailing foetal swallowing of GIP-containing AF and subsequent excretion via the foetal kidneys. CONCLUSIONS: The study shows evidence, for the first time, of the foetal exposure to gluten immunogenic peptides and establishes a positive correlation with maternal gluten intake. The results obtained point to a novel physiological concept as they describe a plausible closed-loop circuit entailing foetal swallowing of GIP contained in AF and its subsequent excretion through the foetal kidneys. The study adds important new information to understanding the coeliac exposome.
Assuntos
Doença Celíaca , Glutens , Humanos , Feminino , Gravidez , Doença Celíaca/imunologia , Adulto , Líquido Amniótico/química , Líquido Amniótico/metabolismo , Expossoma , Peptídeos , Imunoensaio/métodos , Polipeptídeo Inibidor Gástrico , FetoRESUMO
INTRODUCTION AND HYPOTHESIS: The objective was to create and validate the usefulness of a convolutional neural network (CNN) for identifying different organs of the pelvic floor in the midsagittal plane via dynamic ultrasound. METHODS: This observational and prospective study included 110 patients. Transperineal ultrasound scans were performed by an expert sonographer of the pelvic floor. A video of each patient was made that captured the midsagittal plane of the pelvic floor at rest and the change in the pelvic structures during the Valsalva maneuver. After saving the captured videos, we manually labeled the different organs in each video. Three different architectures were tested-UNet, FPN, and LinkNet-to determine which CNN model best recognized anatomical structures. The best model was trained with the 86 cases for the number of epochs determined by the stop criterion via cross-validation. The Dice Similarity Index (DSI) was used for CNN validation. RESULTS: Eighty-six patients were included to train the CNN and 24 to test the CNN. After applying the trained CNN to the 24 test videos, we did not observe any failed segmentation. In fact, we obtained a DSI of 0.79 (95% CI: 0.73 - 0.82) as the median of the 24 test videos. When we studied the organs independently, we observed differences in the DSI of each organ. The poorest DSIs were obtained in the bladder (0.71 [95% CI: 0.70 - 0.73]) and uterus (0.70 [95% CI: 0.68 - 0.74]), whereas the highest DSIs were obtained in the anus (0.81 [95% CI: 0.80 - 0.86]) and levator ani muscle (0.83 [95% CI: 0.82 - 0.83]). CONCLUSIONS: Our results show that it is possible to apply deep learning using a trained CNN to identify different pelvic floor organs in the midsagittal plane via dynamic ultrasound.
RESUMO
OBJECTIVES: The changes of the extracellular matrix of the connective tissue have significantly contributed to the incidence of pelvic organ prolapse (POP). It seems reasonable that sonoelastography could be a useful tool to evaluate the elasticity of pelvic floor tissue in patients with POP and compare it to those without POP. The main aim of this pilot study was to determine if there are differences in the elasticity of the levator ani muscle (LAM) and vaginal tissue between patients with and without POP. METHODS: Prospective observation study, including 60 patients (30 with POP and 30 without POP). Sonoelastography was performed to evaluate the elasticity (in kilopascals, kPa) of the following regions of interest: vagina at the level of middle third of the urethra; vagina at the level of the bladder trigone; vagina in the anterior and posterior fornix; vagina at the level of middle third of the anorectal canal; posterior third of the LAM. RESULTS: A total of 60 patients completed the study (30 with POP, 30 without POP). In the POP group, 18/30 (60%) had an anterior vaginal wall prolapse, 3/30 (10%) a uterine prolapse, 15/30 (50%) a rectocele, and 6/30 (20%) a enterocele. Patients with POP had higher elasticity in all anatomical study areas, with statistically significant differences in the anterior fornix (13.6 vs 11.2 kPa; P: .012). A multiple regression (controlling age, menopausal stage, and parity) allowed to detect statistically significant differences in the elasticity of the middle third of the urethra (P: .03) and the middle third of the anorectal canal (P: .019). CONCLUSION: It is possible to evaluate the elasticity of the LAM and vaginal tissue using sonoelastography, detecting a higher elasticity in patients with POP than in those without POP.
Assuntos
Técnicas de Imagem por Elasticidade , Prolapso de Órgão Pélvico , Prolapso Uterino , Feminino , Humanos , Elasticidade , Diafragma da Pelve/diagnóstico por imagem , Prolapso de Órgão Pélvico/diagnóstico por imagem , Projetos Piloto , Estudos Prospectivos , Vagina/diagnóstico por imagemRESUMO
OBJECTIVE: To determine if the addition of the assessment of levator ani muscle (LAM) avulsion to the measurement of the difference in the pubis-uterine fundus distance between rest and with the Valsalva maneuver could increase the diagnostic capacity of ultrasound for uterine prolapse (UP). METHODS: This multicenter, observational and prospective study included 145 patients. Ultrasound assessment was performed, establishing the diagnosis of UP as a difference between the pubic-uterine fundus distance at rest and during the Valsalva maneuver ≥15 mm (standard technique), while LAM avulsion was defined as an abnormal LAM insertion in three central slices using multislice ultrasound. A binary multivariate logistic regression model was made using nonautomated methods to predict surgical UP (general population, premenopausal, and postmenopausal patients), including the difference between the pubis-uterine fundus distance at rest and with the Valsalva maneuver as well as LAM avulsion. RESULTS: A total of 143 patients completed the study. The addition of LAM avulsion criteria to the standard dynamic distance-based protocol for the diagnosis of UP resulted in a higher sensitivity for the general population (79.7 vs 68.1%) as well as for premenopausal (89.3 vs 79.9%) and postmenopausal patients (76 vs 66.1%). In contrast, the standard technique showed a higher specificity than the model based on the standard technique associated with LAM avulsion for the general population (89.2 vs 74.3%) and premenopausal women (91.7 vs 63.2%). For postmenopausal patients, the model based on the standard technique associated with LAM avulsion had a higher sensitivity (76 vs 66.1%) and specificity (91.7 vs 86.8%) than the ultrasound diagnosis of UP. CONCLUSION: The implementation of the assessment of LAM avulsion in the ultrasound diagnosis of UP is useful in postmenopausal patients, increasing sensitivity and specificity relative to the ultrasound assessment based only on the difference between the pubis-uterine fundus distance at rest and with the Valsalva maneuver.
Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Humanos , Feminino , Estudos Prospectivos , Ultrassonografia , Diafragma da Pelve/diagnóstico por imagemRESUMO
OBJECTIVES: To validate an ultrasound software that uses transperineal ultrasound to diagnose uterine prolapse (UP). METHODS: Multicenter, observational and prospective study with 155 patients that had indications for surgical intervention for dysfunctional pelvic floor pathology. Each patient underwent an examination with Pozzi tenaculum forceps was performed in the operating room with the patient anesthetized, followed by surgical correction of stages II-IV UP. Transperineal ultrasound was used to assess the difference in the pubis-uterine fundus measurement. With a multivariate logistic regression binary model (with the measurement ultrasound at rest, the Valsalva maneuver and age) using nonautomated methods to predict UP. With the purpose of evaluating the model, a table with coordinates of the receiver operating characteristic (ROC) curve, after which sensitivity and specificity were assessed. RESULTS: A total of 153 patients were included (73 with a diagnosis of surgical UP). It was obtained from the AUC (0.89) of the probabilities predicted by the model (95% confidence interval, 0.84-0.95; P < .0005). Based on the ROC curve for the model, obtaining a sensitivity of 91.8% and a specificity of 72.7%, values that were superior to those for the clinical exam for surgical UP (sensitivity: 80.8%; specificity: 71.3%). CONCLUSIONS: We validated software that uses transperineal ultrasound of the pelvic floor and patient age to generate a more reliable diagnosis of surgical UP than that obtained from clinical examinations.
RESUMO
OBJECTIVES: It is unknown whether diagnosing uterine prolapse (UP) via ultrasound or surgical criteria is superior. Our objective is to determine whether the diagnostic capacity of ultrasound with surgical criteria differs from that of surgical criteria only. METHODS: This was a multicenter prospective observational study with 54 premenopausal patients with surgical criteria for a dysfunctional pelvic floor pathology who were consecutively recruited for 1 year. Clinical UP with surgical criteria was defined when UP stage II-IV was identified (during pelvic floor consultation), and UP diagnosed by ultrasound with surgical criteria was established when a difference ≥15 mm was found between rest and Valsalva applied to the pubis-uterine fundus. The sensitivity, specificity and positive and negative predictive values were determined to evaluate clinical and ultrasound methodologies as diagnostic tests. RESULTS: UP diagnosed by ultrasound with surgical criteria presented better sensitivity (78.57 vs 35.71%), specificity (92.11 vs 81.58%), positive predictive value (61.83 vs 23.99%), and negative predictive value (96.35 vs 11.37%) than UP diagnosed by surgical criteria only. CONCLUSION: Ultrasound with surgical criteria is superior to surgical criteria alone when diagnosing UP.
Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Feminino , Humanos , Prolapso de Órgão Pélvico/diagnóstico por imagem , Prolapso de Órgão Pélvico/cirurgia , Útero/diagnóstico por imagem , Valor Preditivo dos Testes , Ultrassonografia/métodosRESUMO
Fetal magnetic resonance imaging (MRI) is increasingly being used worldwide as a complementary tool to prenatal ultrasound (US) for multiple fetal pathologies. The aim of this article is to describe and illustrate how MRI can help US to evaluate fetal abdominal anomalies, based on cases performed in a tertiary public university hospital. Prenatal US, fetal MRI and postnatal imaging of these cases will be shown side-by-side to describe and illustrate the added value of fetal MRI in the different organs/systems and its impact on clinical management.
Assuntos
Diagnóstico Pré-Natal , Ultrassonografia Pré-Natal , Gravidez , Feminino , Humanos , Diagnóstico Pré-Natal/métodos , Ultrassonografia Pré-Natal/métodos , Imageamento por Ressonância Magnética/métodos , Abdome/diagnóstico por imagem , Feto , Estudos RetrospectivosRESUMO
Congenital thoracic anomalies are uncommon malformations that require a precise diagnosis to guide parental counseling and possible prenatal treatment. Prenatal ultrasound (US) is the gold standard imaging modality to first detect and characterize these abnormalities and the best modality for follow-up. Fetal magnetic resonance imaging (MRI) is a complementary tool that provides multiplanar assessment and tissue characterization and can help estimate prognosis. Prenatal treatment is increasingly being used in fetuses with signs of distress and to potentially decrease morbidity and mortality. In this essay, the authors illustrate side-by-side US, MRI and therapeutic options for congenital thoracic anomalies in cases that presented to a tertiary pediatric hospital during the 7-year period 2014-2021. Entities included are congenital diaphragmatic hernia, congenital pulmonary airway malformation, bronchopulmonary sequestration, hybrid lesions, foregut duplications cysts and congenital lobar overinflation. Treatment options include maternal steroids, thoraco-amniotic shunt and fetal endotracheal occlusion. Recognition of typical findings in congenital thoracic anomalies is helpful to establish diagnosis, predict prognosis and plan perinatal treatment.
Assuntos
Malformação Adenomatoide Cística Congênita do Pulmão , Hérnias Diafragmáticas Congênitas , Gravidez , Feminino , Humanos , Criança , Diagnóstico Pré-Natal/métodos , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Hérnias Diafragmáticas Congênitas/cirurgia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Pré-Natal/métodosRESUMO
OBJECTIVES: Our study aims to determine the interobserver variability of different ultrasound measurements (pubis-cervix distance, pubis-uterine fundus distance, and pubis-Douglascul-de-sac distance) previously analyzed for the ultrasound differential diagnosis of uterine prolapse (UP) and cervical elongation CE without UP. MATERIALS AND METHODS: We conducted a prospective observational study with 40 patients scheduled to undergo surgical correction of UP and CE without UP. All patients underwent pelvic floor ultrasound examination by an examiner (E1) who acquired ultrasound images. Using these images, E1 measured the distances for the ultrasound differential diagnosis of UP and CE without UP, and these distances were compared with those measured by the other examiner (E2). Values were analyzed by calculating ICCs with 95% CIs. RESULTS: For UP, excellent reliability was obtained for all measurements except the pubis-Douglascul-de-sac measurement at rest, which was moderate (ICC 0.596; p = 0.028) and for the difference between the pubis-Douglascul-de-sac measurement at rest and during the Valsalva maneuver, which was good (ICC 0.691; p < 0.0005). For CE without UP, interobserver reliability was excellent for all measurements analyzed except the pubis-cervix measurement during the Valsalva maneuver, which was moderate (ICC 0.535; p = 0.052) and for the pubis-Douglascul-de-sac measurement at rest, which was good (ICC 0.768; p < 0.0005). CONCLUSIONS: There is excellent interobserver reliability in measurements of the difference in the distance from the pubic symphysis to the uterine fundus at rest and during the Valsalva maneuver for both UP and CE without UP, which are used for the ultrasound differential diagnosis of UP and CE without UP.
Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Diagnóstico Diferencial , Feminino , Humanos , Imageamento Tridimensional/métodos , Variações Dependentes do Observador , Prolapso de Órgão Pélvico/diagnóstico por imagem , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Prolapso Uterino/diagnóstico por imagem , Manobra de ValsalvaRESUMO
BACKGROUND: To determine whether severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2, the cause of COVID-19 disease) exposure in pregnancy, compared to non-exposure, is associated with infection-related obstetric morbidity. METHODS: We conducted a multicentre prospective study in pregnancy based on a universal antenatal screening program for SARS-CoV-2 infection. Throughout Spain 45 hospitals tested all women at admission on delivery ward using polymerase-chain-reaction (PCR) for COVID-19 since late March 2020. The cohort of positive mothers and the concurrent sample of negative mothers was followed up until 6-weeks post-partum. Multivariable logistic regression analysis, adjusting for known confounding variables, determined the adjusted odds ratio (aOR) with 95% confidence intervals (95% CI) of the association of SARS-CoV-2 infection and obstetric outcomes. MAIN OUTCOME MEASURES: Preterm delivery (primary), premature rupture of membranes and neonatal intensive care unit admissions. RESULTS: Among 1009 screened pregnancies, 246 were SARS-CoV-2 positive. Compared to negative mothers (763 cases), SARS-CoV-2 infection increased the odds of preterm birth (34 vs 51, 13.8% vs 6.7%, aOR 2.12, 95% CI 1.32-3.36, p = 0.002); iatrogenic preterm delivery was more frequent in infected women (4.9% vs 1.3%, p = 0.001), while the occurrence of spontaneous preterm deliveries was statistically similar (6.1% vs 4.7%). An increased risk of premature rupture of membranes at term (39 vs 75, 15.8% vs 9.8%, aOR 1.70, 95% CI 1.11-2.57, p = 0.013) and neonatal intensive care unit admissions (23 vs 18, 9.3% vs 2.4%, aOR 4.62, 95% CI 2.43-8.94, p < 0.001) was also observed in positive mothers. CONCLUSION: This prospective multicentre study demonstrated that pregnant women infected with SARS-CoV-2 have more infection-related obstetric morbidity. This hypothesis merits evaluation of a causal association in further research.
Assuntos
COVID-19/epidemiologia , Ruptura Prematura de Membranas Fetais/epidemiologia , Complicações Infecciosas na Gravidez/epidemiologia , Nascimento Prematuro/epidemiologia , Adolescente , Adulto , Estudos de Casos e Controles , Cesárea/estatística & dados numéricos , Feminino , Idade Gestacional , Humanos , Lactente Extremamente Prematuro , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Trabalho de Parto Induzido/estatística & dados numéricos , Modelos Logísticos , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Gravidez , Estudos Prospectivos , SARS-CoV-2 , Espanha/epidemiologia , Adulto JovemRESUMO
BACKGROUND: Gestational diabetes mellitus is associated with increased incidence of adverse perinatal outcomes including newborns large for gestational age, macrosomia, preeclampsia, polyhydramnios, stillbirth, and neonatal morbidity. Thus, fetal growth should be monitored by ultrasound to assess for fetal overnutrition, and thereby, its clinical consequence, macrosomia. However, it is not clear which reference curve to use to define the limits of normality. Our aim is to determine which method, INTERGROWTH21st or customized curves, better identifies the nutritional status of newborns of diabetic mothers. METHODS: This retrospective cohort study compared the risk of malnutrition in SGA newborns and the risk of overnutrition in LGA newborns using INTERGROWTH21st and customized birth weight references in gestational diabetes. The nutritional status of newborns was assessed using the ponderal index. Additionally, to determine the ability of both methods in the identification of neonatal malnutrition and overnutrition, we calculate sensitivity, specificity, positive predictive value, negative predictive value and likelihood ratios. RESULTS: Two hundred thirty-one pregnant women with GDM were included in the study. The rate of SGA indentified by INTERGROWTH21st was 4.7% vs 10.7% identified by the customized curves. The rate of LGA identified by INTERGROWTH21st was 25.6% vs 13.2% identified by the customized method. Newborns identified as SGA by the customized method showed a higher risk of malnutrition than those identified as SGA by INTERGROWTH21st. (RR 4.24 vs 2.5). LGA newborns according to the customized method also showed a higher risk of overnutrition than those classified as LGA according to INTERGROWTH21st. (RR 5.26 vs 3.57). In addition, the positive predictive value of the customized method was superior to that of INTERGROWTH21st in the identification of malnutrition (32% vs 27.27%), severe malnutrition (22.73% vs 20%), overnutrition (51.61% vs 32.20%) and severe overnutrition (28.57% vs 14.89%). CONCLUSIONS: In pregnant women with DMG, the ability of customized fetal growth curves to identify newborns with alterations in nutritional status appears to exceed that of INTERGROWTH21st.
Assuntos
Antropometria/métodos , Diabetes Gestacional , Desenvolvimento Fetal , Transtornos da Nutrição Fetal/epidemiologia , Estado Nutricional , Adulto , Peso ao Nascer , Estudos de Coortes , Feminino , Peso Fetal , Idade Gestacional , Gráficos de Crescimento , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Gravidez , Estudos Retrospectivos , Sensibilidade e Especificidade , EspanhaRESUMO
OBJECTIVES: The association between the use of forceps and levator ani muscle (LAM) avulsion seems to be clear-cut. However, whether the lesion is due to the mechanical trauma yielded by the instrument or to the intrinsic complexity of this type of delivery, is yet to be determined. This study aims at determining the difference in LAM avulsion rate between Kielland rotational forceps and non-rotational forceps. STUDY DESIGN: Prospective observational study with 94 nulliparous women with forceps-assisted deliveries (FD) between July 2015 and January 2016. 3D-TpUS was performed 6 months after every patient's delivery, during which LAM avulsion, and levator hiatus area and anteroposterior and transverse diameters were assessed. RESULTS: A total of 89 nulliparous were studied, comprising 27 rotational-FD, and 62 non-rotational-FD. No differences in obstetric, intrapartum, or neonatal characteristics were observed between study groups. There were no statistically significant differences in the presence of avulsion between cases of rotational forceps (44.4% vs 35.5%, OR: 1.5 [0.6-3.6]), correction of asinclitism of the fetal head (34.4% vs. 40.4% OR: 0.8 [0.3-1.9]) or station (midforceps: 32.8% vs low forceps: 50.0% OR: 2.0 [0.8-5.1]). CONCLUSIONS: We have not observed differences in the LAM-avulsion rate between rotational forceps and non-rotational forceps performed by highly experienced personnel in instrumental deliveries.
Assuntos
Canal Anal/diagnóstico por imagem , Parto Obstétrico/instrumentação , Diafragma da Pelve/diagnóstico por imagem , Instrumentos Cirúrgicos , Ultrassonografia , Adulto , Feminino , Humanos , Período Pós-Parto , Gravidez , Estudos Prospectivos , Adulto JovemRESUMO
OBJECTIVE: Description and assessment by 3-D transperineal ultrasound of modifications suffered by pelvic floor muscles during the passage of the fetal head through the birth canal during the second stage of labor, as well as the identification of the precise moment in which levator ani muscle avulsion takes place. MATERIALS AND METHODS: Patients included were 35 primigravidae, recruited during the first stage of labor, with at term pregnancy (37-42 weeks), without serious maternal-fetal pathology and cephalic presentation. A prospective observational study of 35 primigravidae, recruited during the first stage of labor, with at term pregnancy (37-42 weeks), with fetus in cephalic presentation and without serious maternal-fetal pathology. Sonographic evaluation was carried out by 3-D transperineal ultrasound during the first and second stages of labor (with fetal head in 1st, 2nd-3rd and 4th planes of Hodge), immediately postpartum and 6 months postpartum. Ultrasound parameters studied were antero-posterior and transverse diameters, as well as levator hiatus area and levator ani muscle thickness and area. RESULTS: Twenty-one patients were studied (15 spontaneous deliveries; 6 instrumental deliveries). When measured with fetal head in the 4th plane of Hodge, a significant increase both in the levator hiatus area (15.39 cm2 /15.68 cm2 /20.96 cm2 /42.55 cm2 /22.92 cm2 /18.18 cm2 ; P < 0.0005) and in the levator ani muscle area (8.78 cm2 /9.18 cm2 /9.69 cm2 /15.07 cm2 /11.33 cm2 /12.36 cm2 ; P < 0.0005) was identified. Four cases of unilateral right avulsion (two vacuum and two forceps deliveries) were identified. CONCLUSIONS: We conclude that the phase of delivery that causes a major increase in the area of the levator hiatus area and in the levator ani muscle area is when the fetal head reaches the 4th plane of Hodge. Furthermore, data in our paper indicates that the exact moment in which the avulsion of the levator ani muscle is produced is when the bulging of the fetal head on the maternal perineum occurs.
Assuntos
Parto Obstétrico , Imageamento Tridimensional , Trabalho de Parto , Diafragma da Pelve/diagnóstico por imagem , Períneo/diagnóstico por imagem , Ultrassonografia , Adulto , Feminino , Humanos , Gravidez , Estudos Prospectivos , Adulto JovemRESUMO
INTRODUCTION: Vaginal delivery can lead to pelvic floor disorders. Many authors have described pelvic floor injuries that can predict future defects such as urinary incontinence and pelvic organ prolapse. We propose the assessment of urinary stress incontinence and its association with levator ani muscle (LAM) microtrauma (>20% in the levator hiatus area during Valsalva) and macrotraumas (avulsion) identified by 3/4D transperineal ultrasound (3D-TpUS) 36 months post-partum. MATERIALS AND METHODS: This was a prospective observational study including 168 nulliparous women. All patients included were nulliparous with singleton gestation in cephalic presentation, at ≥37 weeks and were recruited on the first day after delivery. Thirty-six months after delivery, 3D-TpUS was carried out to identify LAM lesions (macro or micro). Clinical assessment of urinary stress incontinence (USI) was based on the ICIQ-UI-SF test; a simple stress test and urodynamic test were carried out in the same visit. RESULTS: A total of 105 nulliparous women were studied (51 spontaneous deliveries [SpD] and 54 vacuum-assisted deliveries [VD]). Microtraumas were identified in 35.3% of SpD and 20.4% of VD. Macrotraumas (avulsion) were identified in 9.8% of SpD and 35.2% of VD (p = 0.006). No differences were found in USI between study groups or in relation to the identification of LAM defects (19.2% in the no lesion group, 25% in the macrotrauma and 13.8% in the microtrauma groups; p = not significant). Nor were significant differences found in the results from the different study groups in the International Consultation on Incontinence Modular Questionnaire Urinary Incontinence Short Form (ICIQ-UI SF) test (12.7±2.2 in the no lesion group, 12.5±4.2 in the macrotrauma and 13.25±4.8 in the microtrauma groups; p = NS). CONCLUSION: No difference was observed in USI between patients with and without LAM lesions (microtrauma or macrotrauma) 36 months post-delivery.
Assuntos
Parto Obstétrico/efeitos adversos , Diafragma da Pelve/lesões , Incontinência Urinária por Estresse/etiologia , Adulto , Feminino , Humanos , Diafragma da Pelve/diagnóstico por imagem , Gravidez , Estudos Prospectivos , Ultrassonografia , Incontinência Urinária por Estresse/diagnóstico por imagem , Adulto JovemRESUMO
Background/Objectives: The diagnostic capacity of the preoperative pelvic organ prolapse quantification (POP-Q) system to define surgical pelvic organ prolapse (POP) is sometimes limited. On the other hand, pelvic floor ultrasound can influence the surgical indication for patients with symptomatic POP. Therefore, our objective is to determine how transperineal ultrasound can influence the surgical indication for symptomatic POP. Methods: This is a prospective observational study conducted over two years including patients who underwent corrective surgery for symptomatic POP. All patients underwent a preoperative examination using the POP-Q system to assess POP. Patients in whom the pelvic floor specialist had diagnostic doubts about the stage of POP underwent an ultrasound examination of the POP. Before the surgical procedure and with the patient anesthetized, a new clinical examination was performed using the POP-Q system and surgical correction of the POP was executed when the patient had a decline to stage II or higher. Cohen's kappa coefficient of agreement was used to assess the agreement. Results: Of the 180 patients who met the inclusion criteria, 167 were included (99 with preoperative clinical examination and 68 with preoperative clinical examination and ultrasound study). The kappa index for the diagnosis of surgical uterine prolapse of the preoperative clinical examination (moderate correlation) was lower than the ultrasound examination (very good correlation) (0.493 p < 0.001 and 0.924 p < 0.001). The kappa index for the diagnosis of cervical elongation without surgical uterine prolapse also showed differences between the preoperative clinical examination (good correlation) and the ultrasound examination (very good correlation) (0.749 p < 0.001 and 0.853 p < 0.001). Conclusions: Transperineal ultrasound has a higher concordance than presurgical clinical examination, based on the POP-Q system, for detecting POP with central compartment surgical indication.
RESUMO
BACKGROUND: Several ultrasound (US) features help ultrasound experts in the classification of benign vs. malignant adnexal masses. US scores serve in this differentiation, but they all have misdiagnoses. The main objective of this study is to evaluate what ultrasound characteristics are associated with malignancy influencing ultrasound scores. METHODS: This is a retrospective analysis of ultrasound features of adnexal lesions of women managed surgically. Ultrasound characteristics were analyzed, and masses were classified by subjective assessment of the ultrasonographer (SA) and other ultrasound scores (IOTA Simple Rules Risk Assessment SRRA, ADNEX model, and O-RADS). RESULTS: Of a total of 187 adnexal masses studied, 134 were benign (71.7%) and 53 were malignant (28.3%). SA, IOTA SRRA, ADNEX model with or without CA125 and O-RADS had high levels of sensitivity (93.9%, 81.1%, 94.3%, 88.7%, 98.1%) but lower specificity (80.2%, 82.1%, 82.8%, 77.6%, 73.1%) with similar AUC (0.87, 0.87, 0.92, 0.90, 0.86). Ultrasound features significantly related with malignancy were the presence of irregular contour, absence of acoustic shadowing, vascularized solid areas, ≥1 papillae, vascularized septum, and moderate-severe ascites. CONCLUSION: IOTA SRRA, ADNEX model, and O-RADS can help in the classification of benign and malignant masses. Certain ultrasound characteristics studied in ultrasound scores are associated with malignancy.
RESUMO
Background: The identification of late-onset fetal growth restriction (FGR) fetuses remains a challenge, given the difficulty to distinguish them from healthy small for gestational age (SGA) fetuses. Given the limitations of conventional Doppler for the identification of placental insufficiency, the appearance of superb microvascular imaging (SMI) Doppler seems promising. Our main objective was to evaluate the diagnostic capability of SMI Doppler for the detection of placental insufficiency findings. Methods: A prospective observational study was conducted at a tertiary care center, including 51 patients who had been diagnosed with late on-set SGA or FGR. A placental ultrasonographic evaluation was carried out using SMI Doppler. Patients were sorted into two groups attending to the histologic evaluation of the placentas after delivery: Group 1 (21 cases), Normal group; and Group 2 (30 cases), FGR group. Results: Placentas in the FGR group had lower peak systolic velocity (PV) values of the chorionic plate. The PV of the other vessels were consistently lower in the FGR group that in the normal group, although without reaching statistical significance. Conclusions: The PV of the chorionic plate measured with SMI Doppler, have the capacity to identify placental insufficiency findings. Ultrasonographic placental assessment using SMI Doppler appears to be a useful technique for the evaluation of suspected late on-set placental insufficiency.
RESUMO
Although the fetal head position has traditionally been evaluated by digital examination (DE), it has a failure rate ranging between 20 and 70%; hence, intrapartum transabdominal ultrasonography (TUS) has become relevant. We aimed to evaluate the utility of the TUS to identify the fetal head positions in vacuum-assisted deliveries. We performed a prospective observational study including 101 pregnant patients in active labor who required a vacuum-assisted delivery. The fetal head position was assessed by a DE and a TUS prior to vacuum cup placement. After delivery, the optimal vacuum cup placement was evaluated as the distance between the chignon and the flexion point ≤2 cm. The general concordance rate between the DE and TUS was 72.2%, with the poorest concordance rate for occiput posterior positions at 46.1%. In five cases (4.9%), it was not possible to determine the fetal head position through the DE. The correlation was higher in low and medium planes, with 77% and 68.1% concordance rates, respectively, while it was lower in high planes (60%). In 90.1% of cases, the vacuum cup placement was optimal. Our findings show that intrapartum transabdominal ultrasonography is a useful technique to identify the fetal head position allowing optimal placement of the vacuum cup necessary for correct vacuum-assisted delivery.
Assuntos
Feto , Apresentação no Trabalho de Parto , Feminino , Gravidez , Humanos , Ultrassonografia Pré-Natal/métodos , Ultrassonografia , Vácuo-Extração/métodosRESUMO
Background: The anorectal angle (ARA) has been assessed with different imaging methods and its measurement has traditionally been based on defecography or magnetic resonance studies. Different ultrasound methodologies have also been used for ARA assessment and have been validated as alternatives for the ARA measurement, such as three-dimensional (3D) endovaginal ultrasound and 3D transperineal ultrasound. 3D transperineal ultrasound does not require the introduction of ultrasound transducers inside the anal canal. Therefore, it is reasonable to think that the use of transperineal ultrasound can provide more reproducible ARA measurements, something that has not been established by 3D endovaginal probe or defecography. Our objective is to determine the intraobserver and interobserver variability of transperineal ultrasound for the assessment of ARA. Methods: A retrospective observational study was performed with 40 patients. The study of the ARA was performed from the mid-sagittal plane (at rest, Valsalva and maximum contraction), visualizing the anorectal canal, the anorectal junction and the rectal ampulla. ARA measurements were performed initially by explorer 1 (E1), subsequently by explorer 2 (E2) and finally again by E1. Intraobserver and interobserver variability was calculated by calculating the intraclass correlation coefficient (ICC) with 95% confidence interval (CI). Results: Intraobserver variability was excellent for all measurements of the ARA at rest, Valsalva and maximal contraction, with ICC ranging from 0.968 to 0.975. Interobserver variability was also superb for all measurements of the ARA at rest, Valsalva and maximal contraction, with ICC ranging from 0.971 to 0.979. Conclusions: Intraobserver and interobserver variability were excellent for the ARA measurements by transperineal ultrasound.
RESUMO
OBJECTIVE: To perform a multicenter study of muscle recovery in levator ani muscle (LAM) avulsion during the first 12 months postpartum according to the type of LAM avulsion suffered. METHODS: This was a multicenter prospective observational study including 242 primiparas. Transperineal ultrasound was performed at 6 months and 12 months after delivery. Type I LAM avulsion was present when most of the lateral fibers of the pubovisceral muscle were observed at the muscle's insertion at the pubic level. Type II LAM avulsion was defined as complete detachment of the pubovisceral muscle from its insertion at the pubic level. RESULTS: Among the 56 patients who completed the study (with ultrasound at 6 and 12 months after delivery), 76 avulsions (10 cases of bilateral avulsion) were identified at 6 months after delivery, and the total number of avulsions had decreased to 58 at 12 months after delivery (P < 0.001; 95% confidence interval [CI] 13.9%-33.5%). This decrease was due to the disappearance of 69.2% of the cases of Type I LAM avulsions (P < 0.001; 95% CI: 50.2%-88.2%). However, the number of Type II LAM avulsions remained constant at 6 months and 12 months after delivery. CONCLUSION: The spontaneous resolution of LAM avulsion during the first 12 months postpartum occurs in cases of Type I LAM avulsion but is not observed in Type II LAM avulsion.