Med Phys ; 51(1): 447-463, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37947472

RESUMO

BACKGROUND: Carbon nanotube-based cold cathode technology has revolutionized the miniaturization of X-ray tubes. However, current applications of these devices required optimization for large, uniform fields with low intensity. PURPOSE: This work investigated the feasibility and radiological characteristics of a novel conical X-ray target optimized for high intensity and high directionality to be used in a compact X-ray tube. METHODS: The proposed device uses an ultrathin, conical tungsten-diamond target that exhibits significant heat loading while maintaining a small focal spot size and promoting forward-directedness of the X-ray field through preferential attenuation of oblique-angled photons. The electrostatic and thermal properties of the theoretical tube were calculated and analyzed using COMSOL Multiphysics software. The production, transport, and calculation of radiological properties associated with the resultant X-ray field were performed using the Geant4 toolkit via its wrapper, TOPAS. RESULTS: Heat transfer analysis of this X-ray tube demonstrated the feasibility of a 200-kV electron beam bombarding the proposed target at a maximum current of 100 mA using a 1-ms symmetric duty cycle. The cathode of the X-ray tube was designed to be segmented into nine switchable electrical segments for modulation of the focal spot size from 0.4- to 10.8-mm. After importing the COMSOL-derived electron beam into TOPAS for X-ray production simulations, radiological analysis of the resultant field demonstrated high levels of intrinsic beam collimation while maintaining high intensity. A maximum dose rate of 17,887 cGy/min was calculated for 1-mm depth in water at 7-cm distance. CONCLUSIONS: The proposed X-ray tube design can create highly directional X-ray fields with superior fluence compared to that of current commercial X-ray tubes of comparable size.


Assuntos
Nanotubos de Carbono , Raios X , Radiografia , Fluoroscopia , Software , Método de Monte Carlo
2.
Phys Med Biol ; 69(10)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38588671

RESUMO

Objective. A novel x-ray field produced by an ultrathin conical target is described in the literature. However, the optimal design for an associated collimator remains ambiguous. Current optimization methods using Monte Carlo calculations restrict the efficiency and robustness of the design process. A more generic optimization method that reduces parameter constraints while minimizing computational load is necessary. A numerical method for optimizing the longitudinal collimator hole geometry for a cylindrically-symmetrical x-ray tube is demonstrated and compared to Monte Carlo calculations.Approach. The x-ray phase space was modelled as a four-dimensional histogram differential in photon initial position, final position, and photon energy. The collimator was modeled as a stack of thin washers with varying inner radii. Simulated annealing was employed to optimize this set of inner radii according to various objective functions calculated on the photon flux at a specified plane.Main results. The analytical transport model used for optimization was validated against Monte Carlo calculations using Geant4 via its wrapper, TOPAS. Optimized collimators and the resulting photon flux profiles are presented for three focal spot sizes and five positions of the source. Optimizations were performed with multiple objective functions based on various weightings of precision, intensity, and field flatness metrics. Finally, a select set of these optimized collimators, plus a parallel-hole collimator for comparison, were modeled in TOPAS. The evolution of the radiation field profiles are presented for various positions of the source for each collimator.Significance. This novel optimization strategy proved consistent and robust across the range of x-ray tube settings regardless of the optimization starting point. Common collimator geometries were re-derived using this algorithm while simultaneously optimizing geometry-specific parameters. The advantages of this strategy over iterative Monte Carlo-based techniques, including computational efficiency, radiation source-specificity, and solution flexibility, make it a desirable optimization method for complex irradiation geometries.


Assuntos
Método de Monte Carlo , Raios X , Fótons , Modelos Teóricos
3.
Med Phys ; 50(7): 4637-4644, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36893446

RESUMO

BACKGROUND: Monte Carlo particle simulation has become the primary tool for designing low-energy miniature x-ray tubes due to the difficulties of physically prototyping these devices and characterizing their radiation fields. Accurate simulation of electronic interactions within their targets is necessary for modeling both photon production and heat transfer. Voxel-averaging can conceal hot spots in the target heat deposition profile that can threaten the integrity of the tube. PURPOSE: This research seeks a computationally-efficient method of estimating voxel-averaging error in energy deposition simulations of electron beams penetrating thin targets to inform the appropriate scoring resolution for a desired accuracy level. METHODS: An analytical model to estimate voxel-averaging along the target depth was developed and compared to results from Geant4 via its wrapper, TOPAS. A 200 keV planar electron beam was simulated to impinge tungsten targets of thicknesses between 1.5- and 12.5- µ m ${{\umu {\rm m}}}$ . For each target, the model was used to calculate the energy deposition ratio between voxels of varying sizes centered on the longitudinal midpoint of the target. Model-calculated ratios were compared to simulation outputs to gauge the model's accuracy. Then, the model was used to approximate the error between the point value of electron energy deposition and a voxel-based measurement. RESULTS: The model underestimates error to within 5% for targets less than 7.5- µ m ${{\umu {\rm m}}}$ in thickness with increasing error for greater thicknesses. For the 1.5- µ m ${{\umu {\rm m}}}$ target, calculations of the point-vs.-voxel energy deposition show an 11% averaging effect between the midpoint and a 1.5- µ m ${{\umu {\rm m}}}$ voxel. Energy deposition profiles along the target depth were also calculated in the Monte Carlo for reference. CONCLUSION: A simple analytical model was developed with reasonable accuracy to guide Monte Carlo users in estimating the appropriate depth-voxel size for thin-target x-ray tube simulations. This methodology can be adapted for other radiological contexts to increase robustness in point-value estimations.


Assuntos
Elétrons , Fótons , Simulação por Computador , Método de Monte Carlo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radiometria/métodos
4.
Arch Bone Jt Surg ; 11(11): 704-710, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38058974

RESUMO

Objectives: Total knee arthroplasty (TKA) serves as an effective surgical treatment method for advanced osteoarthritis (OA). Nonetheless, it is associated with postoperative pain that can influence patients' functional outcome. This study aimed to compare the analgesic effect of subperiosteal and periarticular injection methods of a special local anesthetic in patients who underwent TKA. Methods: This double-blind prospective clinical study was conducted on patients with advanced knee OA who underwent TKA. Patients were randomly divided into two groups, with a local anesthetic (21 ml) administered either in periarticular (P group) or subperiosteal (S group) forms prior to wound closure. The local anesthetic consisted of lidocaine 2% (15 cc), dexmedetomidine (1 cc), and marcaine 0.5% (5 cc). A study-blinded orthopedic resident recorded postoperative pain levels using a 10-point visual analogue score (VAS) (0 indicating no pain, 10 indicating worst pain) at 6, 12, 24, and 48 hours after surgery. Results: A total of 40 patients (P and S group; n=20 each), consisting of 10 males (mean age=67.4 years old), were included in this study. The intensity of pain in the S group was significantly lower than in the P group 24 hours after surgery (mean VAS scores in the P group: 4±1 vs. the S group: 3.3±0.7, P=0.024). Furthermore, VAS scores at 6, 12, and 48 hours post-surgery were lower in the S group compared to the P group; however, the difference was not statistically significant (P>0.05). Conclusion: Our study indicated that subperiosteal injection of lidocaine, dexmedetomidine, and marcaine is more effective than periarticular injection, providing effective postoperative pain management after TKA.

5.
Pract Radiat Oncol ; 13(3): 217-230, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36115498

RESUMO

PURPOSE: Using evidence-based radiation therapy to direct care for patients with breast cancer is critical to standardize practice, improve safety, and optimize outcomes. To address this need, the Veterans Affairs (VA) National Radiation Oncology Program (NROP) established the VA Radiation Oncology Quality Surveillance Program to develop clinical quality measures (QMs). The VA NROP contracted with the American Society for Radiation Oncology to commission 5 Blue Ribbon Panels for breast, lung, prostate, rectal, and head and neck cancers. METHODS AND MATERIALS: The Breast Cancer Blue Ribbon Panel experts worked collaboratively with the NROP to develop consensus QMs for use throughout the VA system, establishing a set of QMs for patients in several areas, including consultation and work-up; simulation, treatment planning, and treatment; and follow-up care. As part of this initiative, consensus dose-volume histogram (DVH) constraints were outlined. RESULTS: In total, 36 QMs were established. Herein, we review the process used to develop QMs and final consensus QMs pertaining to all aspects of radiation patient care, as well as DVH constraints. CONCLUSIONS: The QMs and expert consensus DVH constraints are intended for ongoing quality surveillance within the VA system and centers providing community care for Veterans. They are also available for use by greater non-VA community measures of quality care for patients with breast cancer receiving radiation.


Assuntos
Neoplasias da Mama , Radioterapia (Especialidade) , Veteranos , Masculino , Humanos , Estados Unidos , Neoplasias da Mama/radioterapia , Indicadores de Qualidade em Assistência à Saúde , Radioterapia (Especialidade)/métodos , Consenso
6.
Phys Med Biol ; 67(7)2022 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-35272282

RESUMO

Objective. A novel treatment modality is currently being developed that produces converging monoenergetic x-rays. Conventional application of dosimetric calibration as presented in protocol TG61 is not applicable. Furthermore, the dosimetry of the focal point of the converging beam is on the order of a few millimeters, requiring a high-resolution dosimeter. Here we present a procedure to calibrate radiochromic film for narrow-beam monoenergetic 60 keV photons as well as absolute dosimetry of monoenergetic focused x-rays. A study of the focal spot dose rate after passing through a bone-equivalent material was also done to quantify the effects of heterogeneous materials.Approach.This was accomplished by configuring a polyenergetic beam of equivalent energy using a clinical orthovoltage machine. Calibrated films were then used to perform absolute dosimetry of the converging beam by measuring the beam profile at various depths in water. Main Results.A method for calibrating radiochromic film has been developed and detailed that allows absolute dosimetry of a monoenergetic photon beam. Absolute dosimetry of a focused, mono-energetic beam resulted in a focal spot dose rate of ∼30 cGy min-1at a depth of 5 cm in water.Significance.This work serves to establish a dosimetry protocol for mono-energetic beam absolute dosimetry as well as the use of such a method for measurement of a novel teletherapy modality.


Assuntos
Dosimetria Fotográfica , Radiometria , Calibragem , Dosimetria Fotográfica/métodos , Fótons/uso terapêutico , Radiometria/métodos , Água
7.
Med Phys ; 38(5): 2651-64, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21776802

RESUMO

PURPOSE: The deterministic Acuros XB (AXB) algorithm was recently implemented in the Eclipse treatment planning system. The goal of this study was to compare AXB performance to Monte Carlo (MC) and two standard clinical convolution methods: the anisotropic analytical algorithm (AAA) and the collapsed-cone convolution (CCC) method. METHODS: Homogeneous water and multilayer slab virtual phantoms were used for this study. The multilayer slab phantom had three different materials, representing soft tissue, bone, and lung. Depth dose and lateral dose profiles from AXB v10 in Eclipse were compared to AAA v10 in Eclipse, CCC in Pinnacle3, and EGSnrc MC simulations for 6 and 18 MV photon beams with open fields for both phantoms. In order to further reveal the dosimetric differences between AXB and AAA or CCC, three-dimensional (3D) gamma index analyses were conducted in slab regions and subregions defined by AAPM Task Group 53. RESULTS: The AXB calculations were found to be closer to MC than both AAA and CCC for all the investigated plans, especially in bone and lung regions. The average differences of depth dose profiles between MC and AXB, AAA, or CCC was within 1.1, 4.4, and 2.2%, respectively, for all fields and energies. More specifically, those differences in bone region were up to 1.1, 6.4, and 1.6%; in lung region were up to 0.9, 11.6, and 4.5% for AXB, AAA, and CCC, respectively. AXB was also found to have better dose predictions than AAA and CCC at the tissue interfaces where backscatter occurs. 3D gamma index analyses (percent of dose voxels passing a 2%/2 mm criterion) showed that the dose differences between AAA and AXB are significant (under 60% passed) in the bone region for all field sizes of 6 MV and in the lung region for most of field sizes of both energies. The difference between AXB and CCC was generally small (over 90% passed) except in the lung region for 18 MV 10 x 10 cm2 fields (over 26% passed) and in the bone region for 5 x 5 and 10 x 10 cm2 fields (over 64% passed). With the criterion relaxed to 5%/2 mm, the pass rates were over 90% for both AAA and CCC relative to AXB for all energies and fields, with the exception of AAA 18 MV 2.5 x 2.5 cm2 field, which still did not pass. CONCLUSIONS: In heterogeneous media, AXB dose prediction ability appears to be comparable to MC and superior to current clinical convolution methods. The dose differences between AXB and AAA or CCC are mainly in the bone, lung, and interface regions. The spatial distributions of these differences depend on the field sizes and energies.


Assuntos
Modelos Biológicos , Método de Monte Carlo , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Software , Simulação por Computador , Interpretação Estatística de Dados , Humanos , Modelos Estatísticos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Validação de Programas de Computador
8.
Sci Rep ; 11(1): 19180, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34584192

RESUMO

We describe the development and analysis of a new teletherapy modality that, through a novel approach to targeted radiation delivery, has the potential to provide greater conformality than conventional photon-based treatments. The proposed system uses an X-ray lens to reflect photons from a conventional X-ray tube toward a focal spot. The resulting dose distributions have a highly localized peak dose, with lower doses in the converging radiation cone. Physical principles governing the design of this system are presented, along with a series of measurements analyzing various characteristics of the converging beam. The beam was designed to be nearly monoenergetic (~ 59 keV), with an energy bandwidth of approximately 10 keV allowing for treatment energies lower than conventional therapies. The focal spot was measured to be approximately 2.5 cm long and 4 mm wide. Mounting the proposed X-ray delivery system on a robotic arm would allow sub-millimeter accuracy in focal spot positioning, resulting in highly conformal dose distribution via the optimal placement of individual focal spots within the target volume. Aspects of this novel radiation beam are discussed considering their possible clinical application as a treatment approach that takes maximum advantage of the unique properties afforded by converging X-ray beam therapy.


Assuntos
Lentes , Fótons/uso terapêutico , Radioterapia Conformacional/instrumentação , Desenho de Equipamento , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica
9.
Adv Radiat Oncol ; 6(4): 100683, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33824935

RESUMO

PURPOSE: To provide a series of suggestions for other Medical Physics practices to follow in order to provide effective radiation therapy treatments during the COVID-19 pandemic. METHODS AND MATERIALS: We reviewed our entire Radiation Oncology infrastructure to identify a series of workflows and policy changes that we implemented during the pandemic that yielded more effective practices during this time. RESULTS: We identified a structured list of several suggestions that can help other Medical Physics practices overcome the challenges involved in delivering high quality radiotherapy services during this pandemic. CONCLUSIONS: Our facility encompasses 4 smaller Houston Area Locations (HALs), a main campus with 8 distinct services based on treatment site (ie. Thoracic, Head and Neck, Breast, Gastrointestinal, Gynecology, Genitourinary, Hematologic Malignancies, Melanoma and Sarcoma and Central Nervous System/Pediatrics), a Proton Center facility, an MR-Linac, a Gamma Knife clinic and an array of brachytherapy services. Due to the scope of our services, we have gained experience in dealing with the rapidly changing pandemic effects on our clinical practice. Our paper provides a resource to other Medical Physics practices in search of workflows that have been resilient during these challenging times.

10.
J Appl Clin Med Phys ; 11(1): 3146, 2010 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-20160700

RESUMO

We conducted a metrological evaluation of the dosimetric impact due to the polysulfone cap used with the Fletcher-Williamson (FW) colpostat for 192Ir high-dose rate and pulsed-dose rate intracavitary brachytherapy using Monte Carlo simulations. Polysulfone caps with diameter of 30 mm, 25 mm, 20 mm, and 16 mm (mini-ovoid) were simulated and the absorbed dose rate in the surrounding water was calculated and compared to the dose rate for a bare 192Ir source in water. The dose perturbation depended on the cap diameter, distance away from the cap surface, and angular position around the cap. The largest dose rate reductions were found to be in the direction of the tumor bed where the cap is thickest. The range of perturbation over all depths and cap diameters was +2.8% (dose enhancement) to -6.8% (dose reduction). The FW colpostat cap's material composition should be modified to reduce this dosimetric effect or brachytherapy treatment planning dose algorithms should be improved to account for this perturbation.


Assuntos
Braquiterapia/instrumentação , Radioisótopos de Irídio/uso terapêutico , Método de Monte Carlo , Polímeros/química , Sulfonas/química , Neoplasias do Colo do Útero/radioterapia , Algoritmos , Feminino , Humanos , Mucosa/efeitos da radiação , Equipamentos de Proteção , Radiometria , Dosagem Radioterapêutica , Reto , Eficiência Biológica Relativa , Tungstênio/química , Bexiga Urinária , Vagina/efeitos da radiação
11.
J Appl Clin Med Phys ; 11(4): 3294, 2010 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-21081889

RESUMO

In this work, we develop and test a matchline dosimetry analysis tool (MDAT) to examine the dose distribution within the abutment region of two or more adjoining radiotherapy fields that employ different blocking mechanisms and geometries in forming a match. This objective and quantitative tool uses calibrated radiographic film to measure the dose in the abutment region, and uses a frequency distribution of area versus dose (a dose-area histogram) to visualize the spatial dose distribution. We tested the MDAT's clinical applicability and parameters by evaluating the dose between adjacent photon fields incident on a flat phantom using field-matching techniques employing collimator-jaw and multileaf collimator (MLC) configurations. Additionally, we evaluated the dose in the abutment regions of four different clinical tangential-breast and supraclavicular matching techniques using various combinations of collimator and MLC matches. Using the MDAT tool, it was deter-mined that a 1 cm abutment region width (centered about the theoretical matchline between fields) is the most appropriate width to determine dose homogeneity in a field matching region. Using the MDAT, both subtle and large differences were seen between fields that used MLCs to form the match, compared to flat edge devices such as collimators and external cerrobend blocks. We conclude that the MDAT facilitates a more precise evaluation of the distribution of dose within the region of abutment of radiotherapy fields.


Assuntos
Neoplasias da Mama/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador , Clavícula/efeitos da radiação , Feminino , Humanos , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica
12.
Radiother Oncol ; 91(1): 132-7, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19147246

RESUMO

PURPOSE: To evaluate the photon and neutron out-of-field dose equivalents from 6- and 18-MV intensity-modulated radiation therapy (IMRT) and to investigate the impact of the differences on the associated risk of induced second malignancy using a Monte Carlo model. METHODS AND MATERIALS: A Monte Carlo model created with MCNPX was used to calculate the out-of-field photon dose and neutron dose equivalent from simulated IMRT of the prostate conducted at beam energies of 6 and 18MV. The out-of-field dose equivalent was calculated at the locations of sensitive organs in an anthropomorphic phantom. Based on these doses, the risk of secondary malignancy was calculated based on organ-, gender-, and age-specific risk coefficients for a 50-year-old man. RESULTS: The Monte Carlo model predicted much lower neutron dose equivalents than had been determined previously. Further analysis illuminated the large uncertainties in the neutron dose equivalent and demonstrated the need for better determination of this value, which plays a large role in estimating the risk of secondary malignancies. The Monte Carlo calculations found that the differences in the risk of secondary malignancies conferred by high-energy IMRT versus low-energy IMRT are minimal and insignificant, contrary to prior findings. CONCLUSIONS: The risk of secondary malignancy associated with high-energy radiation therapy may not be as large as previously reported, and likely should not deter the use of high-energy beams. However, the large uncertainties in neutron dose equivalents at specific locations within the patient warrant further study so that the risk of secondary cancers can be estimated with greater accuracy.


Assuntos
Método de Monte Carlo , Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/fisiopatologia , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada , Humanos , Masculino , Nêutrons , Fótons , Neoplasias da Próstata/fisiopatologia , Dosagem Radioterapêutica , Risco
13.
Biomed Microdevices ; 11(4): 925-33, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19381816

RESUMO

Gold nanoparticles can enhance the biological effective dose of radiation delivered to tumors, but few data exist to quantify this effect. The purpose of this project was to build a Monte Carlo simulation model to study the degree of dose enhancement achievable with gold nanoparticles. A Monte Carlo simulation model was first built using Geant4 code. An Ir-192 brachytherapy source in a water phantom was simulated and the calculation model was first validated against previously published data. We then introduced up to 10(13) gold nanospheres per cm(3) into the water phantom and examined their dose enhancement effect. We compared this enhancement against a gold-water mixture model that has been previously used to attempt to quantify nanoparticle dose enhancement. In our benchmark test, dose-rate constant, radial dose function, and two-dimensional anisotropy function calculated with our model were within 2% of those reported previously. Using our simulation model we found that the radiation dose was enhanced up to 60% with 10(13) gold nanospheres per cm(3) (9.6% by weight) in a water phantom selectively around the nanospheres. The comparison study indicated that our model more accurately calculated the dose enhancement effect and that previous methodologies overestimated the dose enhancement up to 16%. Monte Carlo calculations demonstrate that biologically-relevant radiation dose enhancement can be achieved with the use of gold nanospheres. Selective tumor labeling with gold nanospheres may be a strategy for clinically enhancing radiation effects.


Assuntos
Braquiterapia/métodos , Fracionamento da Dose de Radiação , Ouro , Radioisótopos de Irídio/uso terapêutico , Nanopartículas Metálicas , Modelos Teóricos , Neoplasias/radioterapia , Animais , Humanos , Método de Monte Carlo
14.
Med Phys ; 36(4): 1244-50, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19472632

RESUMO

Neutrons are by-products of high-energy radiation therapy and a source of dose to normal tissues. Thus, the presence of neutrons increases a patient's risk of radiation-induced secondary cancer. Although neutrons have been thoroughly studied in air, little research has been focused on neutrons at depths in the patient where radiosensitive structures may exist, resulting in wide variations in neutron dose equivalents between studies. In this study, we characterized properties of neutrons produced during high-energy radiation therapy as a function of their depth in tissue and for different field sizes and different source-to-surface distances (SSD). We used a previously developed Monte Carlo model of an accelerator operated at 18 MV to calculate the neutron fluences, energy spectra, quality factors, and dose equivalents in air and in tissue at depths ranging from 0.1 to 25 cm. In conjunction with the sharply decreasing dose equivalent with increased depth in tissue, the authors found that the neutron energy spectrum changed drastically as a function of depth in tissue. The neutron fluence decreased gradually as the depth increased, while the average neutron energy decreased sharply with increasing depth until a depth of approximately 7.5 cm in tissue, after which it remained nearly constant. There was minimal variation in the quality factor as a function of depth. At a given depth in tissue, the neutron dose equivalent increased slightly with increasing field size and decreasing SSD; however, the percentage depth-dose equivalent curve remained constant outside the primary photon field. Because the neutron dose equivalent, fluence, and energy spectrum changed substantially with depth in tissue, we concluded that when the neutron dose equivalent is being determined at a depth within a patient, the spectrum and quality factor used should be appropriate for depth rather than for in-air conditions. Alternately, an appropriate percent depth-dose equivalent curve should be used to correct the dose equivalent at the patient surface.


Assuntos
Neoplasias/radioterapia , Nêutrons , Radiometria/métodos , Radioterapia de Alta Energia/métodos , Algoritmos , Humanos , Modelos Estatísticos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/efeitos adversos , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Propriedades de Superfície
15.
J Appl Clin Med Phys ; 10(1): 22-32, 2009 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-19223838

RESUMO

It may be possible to use a single device to measure the in vivo dose delivered during radiotherapy, as well as to localize the target volume. This potential, as well as the detectors' ability to relate dosimetry and localization, were evaluated using two implantable MOSFET dosimeters placed inside an acrylic pelvic phantom. A wedged-field photon plan and an eight-field prostate treatment plan were developed. For each plan, conditions were simulated so that detectors were in their correct positions or slightly displaced to represent patient setup error and/or organ motion. Doses measured by the two detectors after irradiation were compared to those calculated by the treatment planning software. Additionally, using localization software and kilovoltage images of each setup, the displacement of the detectors from their correct locations was calculated and compared to the induced physical displacement. For all alignments and detector positions, measured and calculated doses showed an average disagreement of 2.7%. The detectors were easily visualized radiographically and the induced detector displacements were typically recognized by the localization software to within 0.1 cm. The implantable detector functioned well as both an internal dosimeter and as an internal fiducial marker, and thus may be useful as a clinical tool to localize the target volume and verify dose delivery in vivo.


Assuntos
Próteses e Implantes , Radiometria/instrumentação , Humanos , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Software
16.
J Appl Clin Med Phys ; 10(4): 177-187, 2009 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-19918226

RESUMO

Modern dual photon energy linear accelerators often come with a few megavoltage electron beams. The megavoltage electron beam has limited range and relative sharp distal falloff in its depth dose curve compared to that of megavoltage photon beam. Its radiation dose is often delivered appositionally to cover the target volume to its distal 90% depth dose (d90), while avoiding the normal--sometimes critical--structure immediately distal to the target. Varian linear accelerators currently offer selected electron beams of 4, 6, 9, 12, 16 and 20 MeV electron beam energies. However, intermediate electron energy is often needed for optimal dose distribution. In this study we investigated electron beam characteristics and implemented two intermediate 7 and 11 MeV electron beams on Varian linear accelerators. Comprehensive tests and measurements indicated the new electron beams met all dosimetry parameter criteria and operational safety standards. Between the two new electron beams and the existing electron beams we were able to provide a choice of electron beams of 4, 6, 7, 9, 11, 12, 16 and 20 MeV electron energies, which had d90 depth between 1.5 cm and 6.0 cm (from 1.5 cm to 4.0 cm in 0.5 cm increments) to meet our clinical needs.


Assuntos
Elétrons/uso terapêutico , Aceleradores de Partículas/instrumentação , Aceleradores de Partículas/normas , Humanos , Projetos Piloto , Controle de Qualidade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
17.
Med Phys ; 35(5): 1906-11, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18561666

RESUMO

Neutron production is an unwanted result of high-energy radiation therapy and results in secondary exposure of patients and radiation therapists to radiation. Recent studies have shown that delivering therapy using a standard medical accelerator with the flattening filter removed may reduce neutron fluence by nearly 70% over the course of prostate intensity-modulated radiation therapy (IMRT). In the current study, the 197Au Bonner sphere technique was used to compare the neutron spectrum produced when the filter is present and when it is absent. In addition, the following was calculated: (1) the neutron-shielding parameters of source strength and ambient dose equivalent (H0) and (2) using the Monte Carlo technique, the sources of neutron production in the accelerator head. It was found that the neutron spectrum was nearly constant, regardless of the presence of the flattening filter; however, the total fluence and ambient dose equivalent over the course of prostate IMRT were more than 70% lower when the filter was removed. Similarly, shielding parameters were lower when the filter was removed. Finally, the primary collimator and jaws accounted for the majority of neutron production, both with and without the flattening filter; however, with the flattening filter removed, the upper jaw accounted for much more neutron production relative to when the filter was present. Ultimately, removal of the flattening filter may offer several clinical advantages, including a reduction in the dose from neutrons to the patient and to radiation personnel.


Assuntos
Nêutrons , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Desenho de Equipamento , Humanos , Masculino , Método de Monte Carlo , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Espalhamento de Radiação , Software
18.
Med Phys ; 45(4): 1614-1621, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29493803

RESUMO

PURPOSE: Using 3D printing to fabricate patient-specific devices such as tissue compensators, boluses, and phantoms is inexpensive and relatively simple. However, most 3D printing materials have not been well characterized, including their radiologic tissue equivalence. The purposes of this study were to (a) determine the variance in Hounsfield Units (HU) for printed objects, (b) determine if HU varies over time, and (c) calculate the clinical dose uncertainty caused by these material variations. METHODS: For a sample of 10 printed blocks each of PLA, NinjaFlex, ABS, and Cheetah, the average HU and physical density were tracked at initial printing and over the course of 5 weeks, a typical timeframe for a standard course of radiotherapy. After initial printing, half the blocks were stored in open boxes, the other half in sealed bags with desiccant. Variances in HU and density over time were evaluated for the four materials. Various clinical photon and electron beams were used to evaluate potential errors in clinical depth dose as a function of assumptions made during treatment planning. The clinical depth error was defined as the distance between the correctly calculated 90% isodose line and the 90% isodose line calculated using clinically reasonable, but simplified, assumptions. RESULTS: The average HU measurements of individual blocks of PLA, ABS, NinjaFlex, and Cheetah varied by as much as 121, 30, 178, and 30 HU, respectively. The HU variation over 5 weeks was much smaller for all materials. The magnitude of clinical depth errors depended strongly on the material, energy, and assumptions, but some were as large as 9.0 mm. CONCLUSIONS: If proper quality assurance steps are taken, 3D printed objects can be used accurately and effectively in radiation therapy. It is critically important, however, that the properties of any material being used in patient care be well understood and accounted for.


Assuntos
Impressão Tridimensional , Radioterapia (Especialidade) , Incerteza , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica
19.
PLoS One ; 13(10): e0205003, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30286184

RESUMO

PURPOSE: To evaluate the uncertainty of radiomics features from contrast-enhanced breath-hold helical CT scans of non-small cell lung cancer for both manual and semi-automatic segmentation due to intra-observer, inter-observer, and inter-software reliability. METHODS: Three radiation oncologists manually delineated lung tumors twice from 10 CT scans using two software tools (3D-Slicer and MIM Maestro). Additionally, three observers without formal clinical training were instructed to use two semi-automatic segmentation tools, Lesion Sizing Toolkit (LSTK) and GrowCut, to delineate the same tumor volumes. The accuracy of the semi-automatic contours was assessed by comparison with physician manual contours using Dice similarity coefficients and Hausdorff distances. Eighty-three radiomics features were calculated for each delineated tumor contour. Informative features were identified based on their dynamic range and correlation to other features. Feature reliability was then evaluated using intra-class correlation coefficients (ICC). Feature range was used to evaluate the uncertainty of the segmentation methods. RESULTS: From the initial set of 83 features, 40 radiomics features were found to be informative, and these 40 features were used in the subsequent analyses. For both intra-observer and inter-observer reliability, LSTK had higher reliability than GrowCut and the two manual segmentation tools. All observers achieved consistently high ICC values when using LSTK, but the ICC value varied greatly for each observer when using GrowCut and the manual segmentation tools. For inter-software reliability, features were not reproducible across the software tools for either manual or semi-automatic segmentation methods. Additionally, no feature category was found to be more reproducible than another feature category. Feature ranges of LSTK contours were smaller than those of manual contours for all features. CONCLUSION: Radiomics features extracted from LSTK contours were highly reliable across and among observers. With semi-automatic segmentation tools, observers without formal clinical training were comparable to physicians in evaluating tumor segmentation.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Incerteza , Humanos , Variações Dependentes do Observador , Software , Tomografia Computadorizada por Raios X
20.
Phys Imaging Radiat Oncol ; 8: 38-43, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33458415

RESUMO

BACKGROUND AND PURPOSE: Postmastectomy radiotherapy (PMRT) is complex to plan and deliver, but could be improved with 3D-printed, patient-specific electron tissue compensators. The purposes of this study were to develop an algorithm to design patient-specific compensators that achieve clinical goals, to 3D-print the planned compensators, and validate calculated dose distributions with film and thermoluminescent dosimeter (TLD) measurements in 3D-printed phantoms of PMRT patients. MATERIALS AND METHODS: An iterative algorithm was developed to design compensators corresponding to single-field, single-energy electron plans for PMRT patients. The 3D-printable compensators were designed to fit into the electron aperture, with cerrobend poured around it. For a sample of eight patients, calculated dose distributions for compensator plans were compared with patients' (multi-field, multi-energy) clinical treatment plans. For all patients, dosimetric parameters were compared including clinical target volume (CTV), lung, and heart metrics. For validation, compensators were fabricated and irradiated for a set of six 3D-printed patient-specific phantoms. Dose distributions in the phantoms were measured with TLD and film. These measurements were compared with the treatment planning system calculated dose distributions. RESULTS: The compensator treatment plans achieved superior CTV coverage (97% vs 89% of the CTV receiving the prescription dose, p < 0.0025), and similar heart and lung doses (p > 0.35) to the conventional treatment plans. Average differences between calculated and measured TLD values were 2%, and average film profile differences were <2 mm. CONCLUSIONS: We developed a new compensator based treatment methodology for PMRT and demonstrated its validity and superiority to conventional multi-field plans through end-to-end testing.