Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Prehosp Emerg Care ; 28(1): 114-117, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-36857205

RESUMO

BACKGROUND: Tenets of high-quality out-of-hospital cardiac arrest (OHCA) resuscitation include early recognition and treatment of shockable rhythms, and minimizing interruptions in compressions. Little is known about how use of a mechanical compression device affects these elements. We hypothesize that use of such a device is associated with prolonged pauses in compressions to apply the device, and long compression intervals overall. METHODS: We systematically abstracted CPR metrics from 4 months of adult non-traumatic OHCA cases, each of which had at least 10 minutes of resuscitation, used a LUCAS device, and had a valid monitor file attached to the patient care report. Our primary outcomes of interest were the duration of each pause in compressions and the duration of compressions between pauses, stratified by whether or not the LUCAS device was used/applied during the segment. Each pause was further evaluated for a possible associated procedure based on pre-defined criteria. Descriptive statistics, chi-square, and Kruskal-Wallis tests were used as appropriate. RESULTS: Fifty-eight cases were included, median age 62.5 years (IQR 49.3-70.8), 47% female, 66% nonwhite. Overall, 633 compression-pause segments were analyzed (517 with and 116 without LUCAS applied). Spacing of pauses was significantly longer with the LUCAS than without [median (IQR) 133 (82-213) seconds vs. 38 (18-62) seconds, p < 0.05]. When using a LUCAS, compressions were continuous for at least 3 min in 166/517 segments, at least 4 min in 89/517 segments, and at least 5 min in 56/517 segments. Without a LUCAS, compressions were longer than 3 min in 7/116 segments. Pauses exceeded 10 s more frequently with LUCAS application (32/38) than airway management or defibrillation (27/80, p < 0.05). Peri-LUCAS pauses exceeded 30 s in 6/38 cases. CONCLUSION: LUCAS use was associated with long compression intervals without identifiable pauses to assess for pulse or cardiac rhythm, and device application was associated with longer pauses than airway management or defibrillation. The clinical significance and effect on patient outcomes remain uncertain and require further study.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Reanimação Cardiopulmonar/métodos , Serviços Médicos de Emergência/métodos , Parada Cardíaca Extra-Hospitalar/terapia , Manuseio das Vias Aéreas
2.
Prehosp Emerg Care ; 28(1): 118-125, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-36857489

RESUMO

INTRODUCTION: Fewer than 10% of individuals who suffer out-of-hospital cardiac arrest (OHCA) survive with good neurologic function. Bystander CPR more than doubles the chance of survival, and telecommunicator-CPR (T-CPR) during a 9-1-1 call substantially improves the frequency of bystander CPR. OBJECTIVE: We examined the barriers to initiation of T-CPR. METHODS: We analyzed the 9-1-1 call audio from 65 EMS-treated OHCAs from a single US 9-1-1 dispatch center. We initially conducted a thematic analysis aimed at identifying barriers to the initiation of T-CPR. We then conducted a conversation analysis that examined the interactions between telecommunicators and bystanders during the recognition phase (i.e., consciousness and normal breathing). RESULTS: We identified six process themes related to barriers, including incomplete or delayed recognition assessment, delayed repositioning, communication gaps, caller emotional distress, nonessential questions and assessments, and caller refusal, hesitation, or inability to act. We identified three suboptimal outcomes related to arrest recognition and delivery of chest compressions, which are missed OHCA identification, delayed OHCA identification and treatment, and compression instructions not provided following OHCA identification. A primary theme observed during missed OHCA calls was incomplete or delayed recognition assessment and included failure to recognize descriptors indicative of agonal breathing (e.g., "snoring", "slow") or to confirm that breathing was effective in an unconscious victim. CONCLUSIONS: We observed that modifiable barriers identified during 9-1-1 calls where OHCA was missed, or treatment was delayed, were often related to incomplete or delayed recognition assessment. Repositioning delays were a common barrier to the initiation of chest compressions.


Assuntos
Reanimação Cardiopulmonar , Despacho de Emergência Médica , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Humanos , Parada Cardíaca Extra-Hospitalar/terapia , Sistemas de Comunicação entre Serviços de Emergência
4.
Resuscitation ; 182: 109662, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36481240

RESUMO

BACKGROUND: Clinical guidelines for adult out-of-hospital cardiac arrest (OHCA) recommend a ventilation rate of 8-10 per minute yet acknowledge that few data exist to guide recommendations. The goal of this study was to evaluate the utility of continuous capnography to measure ventilation rates and the association with return of spontaneous circulation (ROSC). METHODS: This was a retrospective observational cohort study. We included all OHCA during a two-year period and excluded traumatic and pediatric patients. Ventilations were recorded using non-invasive continuous capnography. Blinded medically trained team members manually annotated all ventilations. Four techniques were used to analyze ventilation rate. The primary outcome was sustained prehospital ROSC. Secondary outcomes were vital status at the end of prehospital care and survival to hospital admission. Univariable and multivariable logistic regression models were constructed. RESULTS: A total of 790 OHCA were analyzed. Only 386 (49%) had useable capnography data. After applying inclusion and exclusion criteria, the final study cohort was 314 patients. The median ventilation rate per minute was 7 (IQR 5.4-8.5). Only 70 (22%) received a guideline-compliant ventilation rate of 8-10 per minute. Sixty-two (20%) achieved the primary outcome. No statistically significant associations were observed between any of the ventilation parameters and patient outcomes in both univariable and multivariable logistic regression models. CONCLUSIONS: We failed to detect an association between intra-arrest ventilation rates measured by continuous capnography and proximal patient outcomes after OHCA. Capnography has poor reliability as a measure of ventilation rate. Achieving guideline-compliant ventilation rates remains challenging.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Adulto , Humanos , Criança , Capnografia , Reanimação Cardiopulmonar/métodos , Estudos de Coortes , Serviços Médicos de Emergência/métodos , Reprodutibilidade dos Testes , Retorno da Circulação Espontânea
5.
Resuscitation ; 178: 102-108, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35483496

RESUMO

OBJECTIVE: Telecommunicator cardiopulmonary resuscitation (T-CPR) is a critical component of optimized out-of-hospital cardiac arrest (OHCA) care. We assessed a pilot tool to capture American Heart Association (AHA) T-CPR measures and T-CPR coaching by telecommunicators using audio review. METHODS: Using a pilot tool, we conducted a retrospective review of 911 call audio from 65 emergency medical services-treated out-of-hospital cardiac arrest (OHCA) patients. Data collection included events (e.g., OHCA recognition), time intervals, and coaching quality measures. We calculated summary statistics for all performance and quality measures. RESULTS: Among 65 cases, the patients' mean age was 64.7 years (SD: 14.6) and 17 (26.2%) were women. Telecommunicator recognition occurred in 72% of cases (47/65). Among 18 non-recognized cases, reviewers determined 12 (66%) were not recognizable based on characteristics of the call. Median time-to-recognition was 76 seconds (n = 40; IQR:39-138), while median time-to-first-instructed-compression was 198 seconds (n = 26; IQR:149-233). In 36 cases where coaching was needed, coaching on compression-depth occurred in 27 (75%); -rate in 28 (78%); and chest recoil in 10 (28%) instances. In 30 cases where repositioning was needed, instruction to position the patient's body flat occurred in 18 (60%) instances, on-back in 22 (73%) instances, and on-ground in 22 (73%) instances. CONCLUSIONS: Successful collection of data to calculate AHA T-CPR measures using a pilot tool for audio review revealed performance near AHA benchmarks, although coaching instructions did not occur in many instances. Application of this standardized tool may aid in T-CPR quality review.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , American Heart Association , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/terapia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA