Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am Heart J ; 244: 54-65, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34774802

RESUMO

OBJECTIVE: To evaluate the epidemiology and outcomes of non-ST-segment-elevation myocardial infarction-cardiogenic shock (NSTEMI-CS) in the United States. METHODS: Adult (>18 years) NSTEMI-CS admissions were identified using the National Inpatient Sample (2000-2017) and classified by tertiles of admission year (2000-2005, 2006-2011 and 2012-2017). Outcomes of interest included temporal trends of prevalence and in-hospital mortality, use of cardiac procedures, in-hospital mortality, hospitalization costs, and length of stay. RESULTS: In over 7.3 million NSTEMI admissions, CS was noted in 189,155 (2.6%). NSTEMI-CS increased from 1.5% in 2000 to 3.6% in 2017 (adjusted odds ratio 2.03 [95% confidence interval 1.97-2.09]; P < .001). Rates of non-cardiac organ failure and cardiac arrest increased during the study period. Between 2000 and 2017, coronary angiography (43.9%-63.9%), early coronary angiography (13.6%-25.6%), percutaneous coronary intervention (14.8%-31.6%), and coronary artery bypass grafting use (19.0%-25.8%) increased (P < .001). Over the study period, the use of intra-aortic balloon pump remained stable (28.6%-28.8%), and both percutaneous left ventricular assist devices (0%-9.1%) and extra-corporeal membrane oxygenation (0.1%-1.6%) increased (all P < .001). In hospital mortality decreased from 50.2% in 2000 to 32.3% in 2017 (adjusted odds ratio 0.27 [95% confidence interval 0.25-0.29]; P < .001). During the 18-year period, hospital lengths of stay decreased, and hospitalization costs increased. CONCLUSIONS: In the United States, prevalence of CS in NSTEMI has increased 2-fold between 2000 and 2017, while in-hospital mortality has decreased during the study period. Use of coronary angiography and percutaneous coronary intervention increased during the study period.


Assuntos
Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Adulto , Mortalidade Hospitalar , Humanos , Balão Intra-Aórtico/efeitos adversos , Infarto do Miocárdio sem Supradesnível do Segmento ST/complicações , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Estados Unidos/epidemiologia
2.
Catheter Cardiovasc Interv ; 97(3): E274-E279, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32442332

RESUMO

OBJECTIVES: The purpose of this study was to explore the feasibility and safety of robotic PCI performed using an off-siteremote-control system in an animal model. BACKGROUND: Access to primary percutaneous coronary intervention (PCI) remains a challenge in acute myocardial infarction management. The combination of telemedicine and robotic PCI allow the potential delivery of primary PCI to remote locations without the delay of transfer. METHODS: This single-center prospective pilot preclinical feasibility study compared robotic PCI with remote PCI on swine across three stages (adjacent room, different floor of the same building, two different buildings). Latency up to 1,000 ms was introduced into the operating environment to simulate decreased network quality (blinded to operator). The primary outcome measures were technical success and acute safety. The secondary outcome measures included lesion wiring time, procedural time and qualitative scoring of the PCI experience by the operator. RESULTS: Across 52 experiments in 15 animals, technical success was 100%. No procedural complications occurred during the study. No significant difference in lesion treatment time was detected between stages (p = .11) and between time per target vessel when latency up to 1,000 ms was introduced (p = .58). Injected delay >250 ms had the greatest impact on procedure perceived lag. Longer procedure time was associated with lower procedure impact score, regardless of injected latency. CONCLUSIONS: Remote robotic PCI was feasible and safe in an animal model. Procedural duration was acceptable and unaffected by network latency. Future studies are needed to determine the safety and feasibility of remote PCI in humans.


Assuntos
Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Animais , Estudos de Viabilidade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Suínos , Fatores de Tempo , Resultado do Tratamento
3.
J Med Syst ; 45(4): 53, 2021 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-33704592

RESUMO

The Transcatheter Aortic Valve Replacement (TAVR) procedure requires an initial consultation and a subsequent procedure by an interventionalist (IC) and surgeon. The IC-surgeon pair coordination is extremely challenging, especially at Mayo Clinic due to provider time commitments distributed across practice, research, and education activities. Current practice aims to establish the coordination manually, resulting in a scheduling process that is cumbersome and time consuming for the schedulers. We develop an algorithm for pairing ICs and surgeons that minimizes the lead time (days elapsed between the clinic consult and procedure). As compared to current practice, this algorithm is able to reduce average lead time by 59% and increase possible IC-surgeon pairs by 7%. The proposed algorithm is shown to be flexible enough to incorporate practice variations such as lead time upper bound and two procedure days for a single consult day. Algorithm alternatives are also presented for practices who may find the proposed algorithm infeasible for their practice.


Assuntos
Estenose da Valva Aórtica , Cirurgiões , Substituição da Valva Aórtica Transcateter , Algoritmos , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Resultado do Tratamento
4.
Am Heart J ; 199: 156-162, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29754655

RESUMO

BACKGROUND: Patients with acute coronary syndrome (ACS) due to unprotected culprit left main coronary artery disease (LMCAD) treated with percutaneous coronary intervention (PCI) are rare, high-risk, and not represented in trials. Data regarding long term outcome after PCI are limited. METHODS: Between January 2000 and December 2014, there were 8,794 patients hospitalized with unstable angina/non-ST elevation myocardial infarction (UA/NSTEMI) or ST-elevation myocardial infarction (STEMI) treated with PCI at our institution; of these, 83 (0.94%) patients were identified as having culprit LMCAD ACS. RESULTS: Of the 83 patients with unprotected LMCAD ACS, 40 patients presented with STEMI and 43 patients presented with UA/NSTEMI. As compared to LM UA/NSTEMI, LM STEMI patients were younger and had less hypertension, with a trend towards greater frequency of cardiogenic shock. Distal LM involvement was common in both groups and did not differ by ACS type. In-hospital mortality was 33% in LM STEMI and 9% in LM UA/NSTEMI (P = .009). Over median follow up of 6.3 years, long term survival rates in both groups were similar (46% for STEMI vs 51% for UA/NSTEMI; P = .50 by log-rank). CONCLUSIONS: Unprotected culprit LMCAD ACS necessitating PCI is uncommon, occurring in <1% of cases, but is associated with reduced survival, with long term follow-up noting continued and similar risk of death regardless of index ACS type.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Estenose Coronária/complicações , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/etiologia , Idoso , Angiografia Coronária , Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
5.
J Card Surg ; 33(5): 243-249, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29654615

RESUMO

OBJECTIVE: To identify variables predictive of increased mortality within 1 year of transcatheter aortic valve replacement (TAVR). METHODS: We retrospectively reviewed the records of 723 consecutive patients who received TAVR from November 2008 through April 2016. Patient and procedure-related characteristics were analyzed with logistic regression for an association with death within 1 year of TAVR. RESULTS: Patient mean age was 81 ± 9 years, male sex was present in 428 patients (59%), and STS predicted risk of mortality was 9.2 ± 6.2%. There were 107 deaths (15%) within 1 year of operation. Multivariable analysis identified increased risk of death with severe chronic lung disease (odds ratio [OR] 2.01; 95% confidence interval [CI] 1.23-3.29; P = 0.006), severe tricuspid valve regurgitation (OR 2.35; 95%CI 1.17-4.30; P = 0.017), vascular injury (OR 2.23; 95%CI 1.15-4.30; P = 0.017), and new-onset dialysis (OR 8.49; 95%CI 3.00-24.03; P < 0.001) (Area under the curve 0.687). When stratified by arterial access, there was increased risk of death following severe tricuspid valve regurgitation, vascular injury, or new-onset dialysis for transfemoral access and severe chronic lung disease or new-onset dialysis for alternative access. CONCLUSION: Patient characteristics and procedure-related complications are both significantly associated with increased risk of death within 1 year of TAVR. Patients with the baseline findings of severe chronic lung disease or severe tricuspid valve regurgitation may not experience mortality benefit from TAVR, and they should be assessed and counselled accordingly. Avoiding procedure-related complications is paramount to a good outcome. The findings have important implications for health care delivery services.


Assuntos
Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Atenção à Saúde , Diálise , Feminino , Previsões , Humanos , Modelos Logísticos , Pneumopatias , Masculino , Análise Multivariada , Estudos Retrospectivos , Risco , Índice de Gravidade de Doença , Fatores de Tempo , Insuficiência da Valva Tricúspide
6.
Am Heart J ; 187: 98-103, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28454813

RESUMO

OBJECTIVES: To assess coronary revascularization outcomes in patients with previous thoracic radiation therapy (XRT). BACKGROUND: Previous chest radiation has been reported to adversely affect long term survival in patients with coronary disease treated with percutaneous coronary interventions (PCI). METHODS: Retrospective, single center cohort study of patients previously treated with thoracic radiation and PCI. Patients were propensity matched against control patients without radiation undergoing revascularization during the same time period. RESULTS: We identified 116 patients with radiation followed by PCI (XRT-PCI group) and 408 controls. Acute procedural complications were similar between groups. There were no differences in all-cause and cardiac mortality between groups (all-cause mortality HR 1.31, P=.078; cardiac mortality 0.78, P=.49). CONCLUSION: Patients with prior thoracic radiation and coronary disease treated with PCI have similar procedural complications and long term mortality when compared to control subjects.


Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea , Neoplasias Torácicas/radioterapia , Idoso , Causas de Morte , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pontuação de Propensão , Radioterapia/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
7.
J Magn Magn Mater ; 427: 100-104, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28286359

RESUMO

Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

8.
Catheter Cardiovasc Interv ; 88(7): 1057-1065, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26698371

RESUMO

OBJECTIVES: To investigate the utility and safety of the GuideLiner "mother-and-child" catheter system during transradial and transfemoral percutaneous coronary intervention (PCI). BACKGROUND: In patients with complex coronary anatomy, stent delivery can be challenging and result in procedural failure and complications. The GuideLiner is a coaxial guide extension system designed to enable deep vessel engagement and facilitate device delivery. The purpose of this study was to evaluate procedural success and safety in a series of GuideLiner-facilitated PCI. METHODS: Single center retrospective study of PCI utilizing the GuideLiner catheter between February 2010 and October 2014. Patients who underwent PCI without GuideLiner use during the same time period were used as controls for comparison. RESULTS: A total of 363 cases of GuideLiner-facilitated PCI were identified from 6,088 unique PCI procedures performed during this same time period. Patients in the GuideLiner group were older (mean age 71.5 vs. 67.8, P < 0.001) and had more multivessel disease (72% vs. 63%, P = 0.001) compared with controls. Type C lesions were present in 78% of GuideLiner cases. Procedural success resulting in successful device delivery with the GuideLiner catheter was 80.2%. Stent deformation associated with GuideLiner use occurred in 2.2% (8/363), with the incidence of this complication decreasing over device iterations. Coronary dissection attributed to GuideLiner occurred in 3.3% (12/363) and became less frequent over the study period. CONCLUSIONS: In this consecutive series of GuideLiner supported PCI, the guide extension system enabled procedural success in the majority. A decline in device-associated complications over time may be attributed to operator learning curve, patient selection, and improvement in catheter design. © 2015 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Cateterismo Periférico/instrumentação , Competência Clínica , Doença da Artéria Coronariana/terapia , Artéria Femoral , Curva de Aprendizado , Intervenção Coronária Percutânea/instrumentação , Artéria Radial , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Periférico/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota , Seleção de Pacientes , Intervenção Coronária Percutânea/efeitos adversos , Punções , Artéria Radial/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
9.
J Korean Med Sci ; 30(6): 716-24, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26028923

RESUMO

Conventional coronary angiography (CAG) has limitations in evaluating lesions producing ischemia. Three dimensional quantitative coronary angiography (3D-QCA) shows reconstructed images of CAG using computer based algorithm, the Cardio-op B system (Paieon Medical, Rosh Ha'ayin, Israel). The aim of this study was to evaluate whether 3D-QCA can reliably predict ischemia assessed by myocardial fractional flow reserve (FFR) < 0.80. 3D-QCA images were reconstructed from CAG which also were evaluated with FFR to assess ischemia. Minimal luminal diameter (MLD), percent diameter stenosis (%DS), minimal luminal area (MLA), and percent area stenosis (%AS) were obtained. The results of 3D-QCA and FFR were compared. A total of 266 patients was enrolled for the present study. FFR for all lesions ranged from 0.57 to 1.00 (0.85 ± 0.09). Measurement of MLD, %DS, MLA, and %AS all were significantly correlated with FFR (r = 0.569, 0609, 0.569, 0.670, respectively, all P < 0.001). In lesions with MLA < 4.0 mm(2), %AS of more than 65.5% had a 80% sensitivity and a 83% specificity to predict FFR < 0.80 (area under curve, AUC was 0.878). 3D-QCA can reliably predict coronary lesions producing ischemia and may be used to guide therapeutic approach for coronary artery disease.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Imageamento Tridimensional/métodos , Isquemia Miocárdica/diagnóstico por imagem , Idoso , Circulação Coronária , Estenose Coronária/etiologia , Feminino , Humanos , Masculino , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Catheter Cardiovasc Interv ; 84(4): 660-7, 2014 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-24327388

RESUMO

BACKGROUND: We sought to determine the utility of a magnetic navigation system (MNS) in treating a variety of coronary artery lesions including those that could not be revascularized with standard percutaneous coronary intervention (PCI). MNS may add value in the treatment of tortuous arteries and bifurcation lesions; however its widespread adoption has lagged because of cost and a lack of clear advantage over conventional PCI. We performed a retrospective analysis to determine whether MNS improved procedural success for highly complex lesions. METHODS AND RESULTS: One hundred and forty-eight patients underwent treatment with MNS at Mayo Clinic, Rochester. Clinical data, angiographic and procedural characteristics, lesion crossing success and outcomes were reviewed. Overall 133 patients underwent successful revascularization with 87% (143) of 164 lesions crossed using MNS alone. Another six lesions required a combination of MNS and conventional devices resulting in overall success of 91% (149/164). Eighteen complex lesions had previously failed PCI and 12 (67%) were successfully treated with MNS. Success after failed PCI was higher (88%) when a frequent user operated MNS, but occasional users also noted incremental success (30%). Twenty-five chronic total occlusions were included amongst these 164 lesions, with observed antegrade MNS lesion crossing rates of 78% for regular and 14% for occasional users. CONCLUSIONS: MNS is a useful adjunct to performance of PCI. This specialized technology has a clear learning curve and can facilitate treatment of highly complex lesions.


Assuntos
Doença da Artéria Coronariana/terapia , Magnetismo , Intervenção Coronária Percutânea/métodos , Terapia Assistida por Computador , Idoso , Competência Clínica , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Minnesota , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
11.
Ann Thorac Surg ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38763221

RESUMO

BACKGROUND: Limited data exist on the long-term outcomes of transcatheter aortic valve insertion (TAVI) in nonagenarian patients. This study investigated the relationship between patient baseline comorbidity and frailty on the long-term outcome of the nonagenarian population. METHODS: A retrospective analysis was conducted of 187 consecutive nonagenarian patients who underwent TAVI from 2009 to 2020. Multivariable models were used to analyze the association between baseline patient and frailty variables and mortality, stroke, and repeat hospitalization. Long-term survival was compared with an age- and sex-matched United States population. RESULTS: The median Society of Thoracic Surgeons predicted risk of mortality was 10% (interquartile range, 7%-17%). Frailty was met in 72% of patients based on the 5-meter walk test, 13% based on the Kansas City Cardiomyopathy Questionnaire 12-item instrument score, 12% based on Katz Index of Independence in Activities of Daily Living, and 8% based on serum albumin levels. Procedure-related death occurred in 3 patients (2%) and stroke in 8 (4%). The median duration of follow-up was 3.4 years. Outcomes included death in 150 patients (80%), stroke in 15, and repeat hospitalization in 114. Multivariable analysis identified no association between any of the baseline patient variables with mortality, stroke, repeat hospitalization, or the combined outcomes (all P > .05). The 1- and 5-year survival rates in TAVI-treated nonagenarians were similar to age- and sex-matched controls (P = .27). CONCLUSIONS: Long-term death or stroke is independent of The Society of Thoracic Surgeons predicted risk of mortality and frailty risk variables in this nonagenarian patient population who received TAVI. Furthermore, survival is similar to age- and sex-matched controls.

12.
Circulation ; 125(4): 592-603, 2012 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-22203692

RESUMO

BACKGROUND: Hematopoiesis originates from the dorsal aorta during embryogenesis. Although adult blood vessels harbor progenitor populations for endothelial and smooth muscle cells, it is not known if they contain hematopoietic progenitor or stem cells. Here, we hypothesized that the arterial wall is a source of hematopoietic progenitor and stem cells in postnatal life. METHODS AND RESULTS: Single-cell aortic disaggregates were prepared from adult chow-fed C57BL/6 and apolipoprotein E-null (ApoE(-/-)) mice. In short- and long-term methylcellulose-based culture, aortic cells generated a broad spectrum of multipotent and lineage-specific hematopoietic colony-forming units, with a preponderance of macrophage colony-forming units. This clonogenicity was higher in lesion-free ApoE(-/-) mice and localized primarily to stem cell antigen-1-positive cells in the adventitia. Expression of stem cell antigen-1 in the aorta colocalized with canonical hematopoietic stem cell markers, as well as CD45 and mature leukocyte antigens. Adoptive transfer of labeled aortic cells from green fluorescent protein transgenic donors to irradiated C57BL/6 recipients confirmed the content of rare hematopoietic stem cells (1 per 4 000 000 cells) capable of self-renewal and durable, low-level reconstitution of leukocytes. Moreover, the predominance of long-term macrophage precursors was evident by late recovery of green fluorescent protein-positive colonies from recipient bone marrow and spleen that were exclusively macrophage colony-forming units. Although trafficking from bone marrow was shown to replenish some of the hematopoietic potential of the aorta after irradiation, the majority of macrophage precursors appeared to arise locally, suggesting long-term residence in the vessel wall. CONCLUSIONS: The postnatal murine aorta contains rare multipotent hematopoietic progenitor/stem cells and is selectively enriched with stem cell antigen-1-positive monocyte/macrophage precursors. These populations may represent novel, local vascular sources of inflammatory cells.


Assuntos
Aorta/citologia , Aorta/crescimento & desenvolvimento , Células-Tronco Hematopoéticas/citologia , Células-Tronco Hematopoéticas/imunologia , Monócitos/citologia , Transferência Adotiva , Animais , Antígenos Ly/metabolismo , Apolipoproteínas E/genética , Biomarcadores/metabolismo , Transplante de Medula Óssea , Linhagem da Célula/imunologia , Endotélio Vascular/citologia , Endotélio Vascular/crescimento & desenvolvimento , Proteínas de Fluorescência Verde/genética , Imunofenotipagem , Macrófagos/citologia , Proteínas de Membrana/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Mutantes , Células-Tronco Multipotentes/citologia , Células-Tronco Multipotentes/imunologia , Músculo Liso Vascular/citologia , Músculo Liso Vascular/crescimento & desenvolvimento , Quimeras de Transplante , Irradiação Corporal Total
13.
Tissue Eng Part A ; 29(15-16): 413-423, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37130041

RESUMO

Recruitment of endothelial cells to cardiovascular device surfaces could solve issues of thrombosis, neointimal hyperplasia, and restenosis. Since current targeting strategies are often nonspecific, new technologies to allow for site-specific cell localization and capture in vivo are needed. The development of cytocompatible superparamagnetic iron oxide nanoparticles has allowed for the use of magnetism for cell targeting. In this study, a magnetic polyurethane (PU)-2205 stainless steel (2205-SS) nanofibrous composite biomaterial was developed through analysis of composite sheets and application to stent-grafts. The PU nanofibers provide strength and elasticity while the 2205-SS microparticles provide ferromagnetic properties. Sheets were electrospun at mass ratios of 0-4:1 (2205-SS:PU) and stent-grafts with magnetic or nonmagnetic stents were coated at the optimal ratio of 2:1. These composite materials were characterized by microscopy, mechanical testing, a sessile drop test, magnetic field measurement, magnetic cell capture assays, and cytocompatibility after 14 days of culturing with endothelial cells. Results of this study show that an optimal ratio of 2:1 2205-SS:PU results in a hydrophobic material that balanced mechanical and magnetic properties and was cytocompatible up to 14 days. Significant cell capture required a thicker material of 0.5 mm thickness. Stent-grafts fabricated from a magnetic coating and a magnetic stent demonstrated uniform cell capture throughout the device surface. This novel biomaterial exhibits a combination of mechanical and magnetic properties that enables magnetic capture of cells and other therapeutic agents for vascular and other tissue engineering applications.


Assuntos
Materiais Biocompatíveis , Nanofibras , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química , Engenharia Tecidual , Nanofibras/química , Poliuretanos/farmacologia , Células Endoteliais , Fenômenos Magnéticos , Materiais Revestidos Biocompatíveis/química
14.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-36645236

RESUMO

OBJECTIVES: Low forced expiratory volume in 1 s (FEV1) and elevated N-terminal pro-B-type natriuretic peptide (NT-Pro-BNP) have been individually associated with poor outcomes after transcatheter aortic valve replacement (TAVR). We hypothesized a combination of the 2 would provide prognostic indication after TAVR. METHODS: We categorized 871 patients who received TAVR from 2008 to 2018 into 4 groups according to baseline FEV1 (<60% or ≥60% predicted) and NT-Pro-BNP (<1601 or ≥1601 pg/ml): group A (n = 312, high FEV1, low NT-Pro-BNP), group B (n = 275, high FEV1, high NT-Pro-BNP), group C (n = 123 low FEV1, low NT-Pro-BNP) and group D (n = 161, low FEV1, high NT-Pro-BNP). The primary end point was survival at 1 and 5 years. RESULTS: Patients in group A had more severe aortic stenosis and achieved the best long-term survival at 1 [93% (95% CI: 90-96)] and 5 [45.3% (95% CI: 35.4-58)] years. Low FEV1 and high NT-Pro-BNP (group D) patients had more severe symptoms, higher Society of Thoracic Surgeons predicted risk of operative mortality, lower ejection fraction and aortic valve gradient at baseline. Patients in group D had the worst survival at 1 [76% (95% CI: 69-83)] and 5 years [13.1% (95% CI: 7-25)], hazard ratio compared to group A: 2.29 (95% CI: 1.6-3.2, P < 0.001) with 25.7% of patients in New York Heart Association class III-IV. Patients in groups B and C had intermediate outcomes. CONCLUSIONS: The combination of FEV1 and NT-Pro-BNP stratifies patients into 4 groups with distinct risk profiles and clinical outcomes. Patients with low FEV1 and high NT-Pro-BNP have increased comorbidities, poor functional outcomes and decreased long-term survival after TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Peptídeo Natriurético Encefálico , Volume Expiratório Forçado , Prognóstico , Fragmentos de Peptídeos , Biomarcadores , Valva Aórtica/cirurgia
15.
Blood ; 116(10): 1787-94, 2010 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-20516367

RESUMO

The antithrombotic surface of endothelium is regulated in a coordinated manner. Tissue factor pathway inhibitor (TFPI) localized at the endothelial cell surface regulates the production of FXa by inhibiting the TF/VIIa complex. Systemic homozygotic deletion of the first Kunitz (K1) domain of TFPI results in intrauterine lethality in mice. Here we define the cellular sources of TFPI and their role in development, hemostasis, and thrombosis using TFPI conditional knockout mice. We used a Cre-lox strategy and generated mice with a floxed exon 4 (TFPI(Flox)) which encodes for the TFPI-K1 domain. Mice bred into Tie2-Cre and LysM-Cre lines to delete TFPI-K1 in endothelial (TFPI(Tie2)) and myelomonocytic (TFPI(LysM)) cells resulted in viable and fertile offspring. Plasma TFPI activity was reduced in the TFPI(Tie2) (71% ± 0.9%, P < .001) and TFPI(LysM) (19% ± 0.6%, P < .001) compared with TFPI(Flox) littermate controls. Tail and cuticle bleeding were unaffected. However, TFPI(Tie2) mice but not TFPI(LysM) mice had increased ferric chloride-induced arterial thrombosis. Taken together, the data reveal distinct roles for endothelial- and myelomonocytic-derived TFPI.


Assuntos
Células Endoteliais/metabolismo , Hemostasia , Lipoproteínas/sangue , Trombose/sangue , Animais , Artérias/metabolismo , Artérias/patologia , Feminino , Estimativa de Kaplan-Meier , Lipoproteínas/genética , Lipoproteínas/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Camundongos Transgênicos , Monócitos/citologia , Monócitos/metabolismo , Receptores Proteína Tirosina Quinases/genética , Receptores Proteína Tirosina Quinases/metabolismo , Receptor TIE-2 , Trombose/metabolismo
16.
Catheter Cardiovasc Interv ; 79(1): 3-19, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22215566

RESUMO

The retrograde approach has revolutionized the treatment of chronic total occlusions. Several retrograde techniques have recently been described. In this article, we present a practical review with step-by-step instructions on the indications for retrograde interventions, equipment and retrograde channel selection, and techniques for retrograde crossing and treatment of chronic total occlusions.


Assuntos
Angioplastia Coronária com Balão/métodos , Oclusão Coronária/terapia , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Catéteres , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Desenho de Equipamento , Humanos , Resultado do Tratamento
17.
J Vis Exp ; (179)2022 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-35068481

RESUMO

The endothelium is a dynamic integrated structure that plays an important role in many physiological functions such as angiogenesis, hemostasis, inflammation, and homeostasis. The endothelium also plays an important role in pathophysiologies such as atherosclerosis, hypertension, and diabetes. Endothelial cells form the inner lining of blood and lymphatic vessels and display heterogeneity in structure and function. Various groups have evaluated the functionality of endothelial cells derived from human peripheral blood with a focus on endothelial progenitor cells derived from hematopoietic stem cells or mature blood outgrowth endothelial cells (or endothelial colony-forming cells). These cells provide an autologous resource for therapeutics and disease modeling. Xenogeneic cells may provide an alternative source of therapeutics due to their availability and homogeneity achieved by using genetically similar animals raised in similar conditions. Hence, a robust protocol for the isolation and expansion of highly proliferative blood outgrowth endothelial cells from porcine peripheral blood has been presented. These cells can be used for numerous applications such as cardiovascular tissue engineering, cell therapy, disease modeling, drug screening, studying endothelial cell biology, and in vitro co-cultures to investigate inflammatory and coagulation responses in xenotransplantation.


Assuntos
Aterosclerose , Células Progenitoras Endoteliais , Animais , Coagulação Sanguínea , Terapia Baseada em Transplante de Células e Tecidos , Suínos , Engenharia Tecidual/métodos
18.
Semin Thorac Cardiovasc Surg ; 34(1): 80-89, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33691188

RESUMO

The survival benefits of pulmonary thromboendarterectomy (PTE) for the treatment of chronic thromboembolic pulmonary hypertension have been well described. However, the significance of right heart hemodynamic changes and their impact on survival remains poorly understood. We sought to characterize the effects of these changes. We conducted a single center, retrospective review of 159 patients who underwent PTE between 1993 and 2015. Echocardiographic and right heart catheterization data were compared longitudinally before and after PTE in order to establish the extent of hemodynamic response to surgery. Kaplan Meier estimates were used to characterize patient survival over time. Univariable and multivariable Cox proportional hazards regression models were used to assess factors associated with long-term mortality. Among the 159 patients studied, 74 (46.5%) were male with a median age of 55 (IQR: 42-66). One-, 5-, 10-, and 15-year survival was 91.0% (95% CI: 86.6-95.6), 79.6% (73.5-86.3), 66.5% (59.2-74.7), and 56.2% (48.1-65.8). Of the 9 candidate risk factors that were evaluated, only advanced age and increased cardiopulmonary bypass time were found to be significantly associated with increased risk of mortality. Pre- and postsurgical echocardiographic imaging data, when available, revealed a median reduction in right ventricular systolic pressure of 29.0 mm Hg (P < 0.0001) and improvement of tricuspid regurgitation (P < 0.0001), both of which appeared to be sustained across long-term follow-up. Improvements in right heart hemodynamics and tricuspid valvular regurgitation persist on long term surveillance following PTE. While patient selection is often driven by the distribution of disease, close postoperative follow up may improve outcomes.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Insuficiência da Valva Tricúspide , Doença Crônica , Endarterectomia/efeitos adversos , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/cirurgia , Masculino , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/cirurgia , Resultado do Tratamento
19.
Am J Cardiol ; 167: 118-124, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35031110

RESUMO

This study aimed to evaluate the use and frequency of complementary and integrative medicine (CIM) therapies in an outpatient cohort with cardiovascular disease (CVD) and compare trends over time. This cross-sectional point-of-care prospective study assessed patients attending a cardiology outpatient clinic. As in our 2009 cohort, data were collected with a 17-question survey on demographic characteristics, CVD history, current use and future interest in CIM. In total, 964 patients completed the survey. CIM use continues to be high (2009 vs 2018, 83.4% vs 81.8%) (p = 0.34), with dietary supplements the most common therapy (75% in both studies). We observed increased use of mind-body therapies (28.5% vs 23.9%, p = 0.02), especially meditation, yoga, and tai chi. Of the patients receiving CIM therapies, 41.9% reported using CIM for heart-related symptoms. Relaxation, stress management, and meditation were the top three mind-body therapies for CVD-related symptoms in both cohorts. Reporting of CIM use to clinicians is low (15%) and interest on future use is high (47%). In conclusion, CIM is highly used in cardiology patients-4 of 10 patients use CIM for CVD-related symptoms. Most take dietary supplements, with an increased use of mind-body therapies. Our data highlight the importance of documenting CIM use in practice and the need for research to document efficacy.


Assuntos
Doenças Cardiovasculares , Terapias Complementares , Medicina Integrativa , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/terapia , Estudos Transversais , Humanos , Estudos Prospectivos
20.
J Am Soc Echocardiogr ; 35(1): 116-123, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34506919

RESUMO

BACKGROUND: Doppler mean gradient (MG) may underestimate aortic stenosis (AS) severity when obtained during atrial fibrillation (AF) because of lower forward flow compared with sinus rhythm (SR). Whether AS is more advanced at the time of referral for aortic valve intervention in AF compared with SR is unknown. The aim of this study was to examine flow-independent computed tomographic aortic valve calcium scores (AVCS) and their concordance to MG in AF versus SR in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: Patients who underwent TAVR from 2016 to 2020 for native valve severe AS with left ventricular ejection fraction ≥ 50% were identified from an institutional TAVR database. MGs during AF and SR in high-gradient AS (HGAS) and low-gradient AS (LGAS) were compared with AVCS (AVCS/MG ratio). AVCS were obtained within 90 days of pre-TAVR echocardiography. RESULTS: Six hundred thirty-three patients were included; median age was 82 years (interquartile range [IQR], 76-86 years), and 46% were women. AF was present in 109 (17%) and SR in 524 (83%) patients during echocardiography. Aortic valve area index was slightly smaller in AF versus SR (0.43 cm2/m2 [IQR, 0.39-0.47 cm2/m2] vs 0.46 cm2/m2 [IQR, 0.41-0.51 cm2/m2], P = .0003). Stroke volume index, transaortic flow rate, and MG were lower in AF (P < .0001 for all). AVCS were higher in men with AF compared with SR (3,510 Agatston units [AU] [IQR, 2,803-4,030 AU] vs 2,722 AU [IQR, 2,180-3,467 AU], P < .0001) in HGAS but not in LGAS. AVCS were not different in women with AF versus SR. Overall AVCS/MG ratios were higher in AF versus SR in HGAS and LGAS (P < .03 for all), except in women with LGAS. CONCLUSIONS: AVCS were higher than expected by MG in AF compared with SR. The very high AVCS in men with AF and HGAS at the time of TAVR suggests late diagnosis of severe AS because of underestimated AS severity during progressive AS and/or late referral to TAVR. Additional studies are needed to examine the extent to which echocardiography may be underestimating AS severity in AF.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cálcio , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA