1.
N Engl J Med ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38912654

RESUMO

BACKGROUND: Obstructive sleep apnea is characterized by disordered breathing during sleep and is associated with major cardiovascular complications; excess adiposity is an etiologic risk factor. Tirzepatide may be a potential treatment. METHODS: We conducted two phase 3, double-blind, randomized, controlled trials involving adults with moderate-to-severe obstructive sleep apnea and obesity. Participants who were not receiving treatment with positive airway pressure (PAP) at baseline were enrolled in trial 1, and those who were receiving PAP therapy at baseline were enrolled in trial 2. The participants were assigned in a 1:1 ratio to receive either the maximum tolerated dose of tirzepatide (10 mg or 15 mg) or placebo for 52 weeks. The primary end point was the change in the apnea-hypopnea index (AHI, the number of apneas and hypopneas during an hour of sleep) from baseline. Key multiplicity-controlled secondary end points included the percent change in AHI and body weight and changes in hypoxic burden, patient-reported sleep impairment and disturbance, high-sensitivity C-reactive protein (hsCRP) concentration, and systolic blood pressure. RESULTS: At baseline, the mean AHI was 51.5 events per hour in trial 1 and 49.5 events per hour in trial 2, and the mean body-mass index (BMI, the weight in kilograms divided by the square of the height in meters) was 39.1 and 38.7, respectively. In trial 1, the mean change in AHI at week 52 was -25.3 events per hour (95% confidence interval [CI], -29.3 to -21.2) with tirzepatide and -5.3 events per hour (95% CI, -9.4 to -1.1) with placebo, for an estimated treatment difference of -20.0 events per hour (95% CI, -25.8 to -14.2) (P<0.001). In trial 2, the mean change in AHI at week 52 was -29.3 events per hour (95% CI, -33.2 to -25.4) with tirzepatide and -5.5 events per hour (95% CI, -9.9 to -1.2) with placebo, for an estimated treatment difference of -23.8 events per hour (95% CI, -29.6 to -17.9) (P<0.001). Significant improvements in the measurements for all prespecified key secondary end points were observed with tirzepatide as compared with placebo. The most frequently reported adverse events with tirzepatide were gastrointestinal in nature and mostly mild to moderate in severity. CONCLUSIONS: Among persons with moderate-to-severe obstructive sleep apnea and obesity, tirzepatide reduced the AHI, body weight, hypoxic burden, hsCRP concentration, and systolic blood pressure and improved sleep-related patient-reported outcomes. (Funded by Eli Lilly; SURMOUNT-OSA ClinicalTrials.gov number, NCT05412004.).

2.
Artigo em Inglês | MEDLINE | ID: mdl-39042859

RESUMO

RATIONALE: Low arousal threshold and poor muscle responsiveness are common determinants of obstructive sleep apnea (OSA). Hypnotics were hypothesized as an alternative OSA treatment via raising the arousal threshold and possibly genioglossus responsiveness. OBJECTIVES: Effect of common hypnotics on arousal threshold, OSA severity and genioglossus responsiveness. METHODS: We searched MEDLINE, EMBASE, CENTRAL and ClinicalTrials.gov for randomized clinical trials, and ran meta-analyses to determine the effect of oral hypnotics on arousal threshold, OSA severity and genioglossus responsiveness. GRADE was used to rate the quality of evidence (QoE). The association between post-treatment AHI and arousal threshold percent reductions was explored in individual patient data (IPD) metanalyses (overall sample and low arousal threshold subgroups). MEASUREMENTS AND MAIN RESULTS: Based on our analysis (27 studies; 25 for AHI, 11 for arousal threshold, 4 for genioglossus responsiveness), hypnotics minimally raised arousal threshold (mean difference [95% CI]: 2.7 [1.5, 3.8] cmH2O epiglottic pressure swings; moderate QoE), but did not change OSA severity (1.4 [3.5, 0.7] events/h; moderate QoE). IPD meta-analysis (N=114) showed no association between changes in arousal threshold and AHI, independent of low arousal threshold subgrouping. However, people with very-low arousal threshold or those who exhibited 0-25% arousal threshold increase from placebo experienced the greatest-yet still modest-post-treatment AHI reductions (10%). Hypnotics did not affect genioglossus responsiveness (high QoE). CONCLUSIONS: Further research testing or clinical use of hypnotics as OSA alternative treatments should be discouraged, unless in the presence of comorbid insomnia or as part of combination therapy in individuals with very-low arousal threshold.

3.
Thorax ; 79(3): 259-268, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38286618

RESUMO

RATIONALE: Acetazolamide and atomoxetine-plus-oxybutynin ('AtoOxy') can improve obstructive sleep apnoea (OSA) by stabilising ventilatory control and improving dilator muscle responsiveness respectively. Given the different pathophysiological mechanisms targeted by each intervention, we tested whether AtoOxy-plus-acetazolamide would be more efficacious than AtoOxy alone. METHODS: In a multicentre randomised crossover trial, 19 patients with moderate-to-severe OSA received AtoOxy (80/5 mg), acetazolamide (500 mg), combined AtoOxy-plus-acetazolamide or placebo at bedtime for three nights (half doses on first night) with a 4-day washout between conditions. Outcomes were assessed at baseline and night 3 of each treatment period. Mixed model analysis compared the reduction in Apnoea-Hypopnoea Index (AHI) from baseline between AtoOxy-plus-acetazolamide and AtoOxy (primary outcome). Secondary outcomes included hypoxic burden and arousal index. RESULTS: Although AtoOxy lowered AHI by 49 (33, 62)%baseline (estimate (95% CI)) vs placebo, and acetazolamide lowered AHI by+34 (14, 50)%baseline vs placebo, AtoOxy-plus-acetazolamide was not superior to AtoOxy alone (difference: -2 (-18, 11)%baseline, primary outcome p=0.8). Likewise, the hypoxic burden was lowered with AtoOxy (+58 (37, 71)%baseline) and acetazolamide (+37 (5, 58)%baseline), but no added benefit versus AtoOxy occurred when combined (difference: -13 (-5, 39)%baseline). Arousal index was also modestly reduced with each intervention (11%baseline-16%baseline). Mechanistic analyses revealed that similar traits (ie, higher baseline compensation, lower loop gain) were associated with both AtoOxy and acetazolamide efficacy. CONCLUSIONS: While AtoOxy halved AHI, and acetazolamide lowered AHI by a third, the combination of these leading experimental interventions provided no greater efficacy than AtoOxy alone. Failure of acetazolamide to further increase efficacy suggests overlapping physiological mechanisms. TRIAL REGISTRATION NUMBER: NCT03892772.


Assuntos
Acetazolamida , Apneia Obstrutiva do Sono , Humanos , Estudos Cross-Over , Acetazolamida/uso terapêutico , Apneia Obstrutiva do Sono/terapia , Quimioterapia Combinada , Cloridrato de Atomoxetina/uso terapêutico
4.
Eur Respir J ; 63(3)2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38212076

RESUMO

BACKGROUND: Over half of all cases of obstructive sleep apnoea (OSA) are classified as supine-related OSA; however, the pathological endotype during supine position is not fully understood. This study aims to investigate the endotypic traits of supine-predominant OSA and explore the variations in endotypic traits between the supine and lateral positions. METHODS: We prospectively recruited 689 adult patients with OSA from a single sleep centre between April 2020 and December 2022. Endotypic traits, namely arousal threshold, collapsibility, loop gain and upper airway muscle compensation, were retrieved from polysomnographic signals. We identified spOSA by a supine to non-supine apnoea-hypopnoea index (AHI) ratio >2. We cross-sectionally compared demographic and endotypic traits between supine-predominant OSA and non-positional OSA and examined the associations between supine-predominant OSA and endotypic traits. Additionally, we compared the changes in endotypic traits between supine and lateral positions in patients with supine-predominant OSA and non-positional OSA. RESULTS: In our study sample, 75.8% of patients were identified as having supine-predominant OSA. Compared to non-positional OSA, supine-predominant OSA was associated with low collapsibility (ß= -3.46 %eupnoea, 95% CI -5.93- -1.00 %eupnoea) and reduced compensation (ß= -6.79 %eupnoea, 95% CI -10.60- -2.99 %eupnoea). When transitioning from the lateral to supine position, patients with supine-predominant OSA had a substantial decrease in compensation compared to those with non-positional OSA (-11.98 versus -6.28 %eupnoea). CONCLUSIONS: Supine-predominant OSA is the prevalent phenotype of OSA in Asian patients. Inadequate upper airway compensation appears to be a crucial underlying pathology in patients with supine-predominant OSA.


Assuntos
Apneia Obstrutiva do Sono , Adulto , Humanos , Decúbito Dorsal/fisiologia , Polissonografia , Apneia Obstrutiva do Sono/diagnóstico , Sono
5.
Eur Respir J ; 63(6)2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38548291

RESUMO

BACKGROUND: Differences in the pharyngeal site of collapse influence efficacy of non-continuous positive airway pressure therapies for obstructive sleep apnoea (OSA). Notably, complete concentric collapse at the level of the palate (CCCp) during drug-induced sleep endoscopy (DISE) is associated with reduced efficacy of hypoglossal nerve stimulation, but CCCp is currently not recognisable using polysomnography. Here we develop a means to estimate DISE-based site of collapse using overnight polysomnography. METHODS: 182 OSA patients provided DISE and polysomnography data. Six polysomnographic flow shape characteristics (mean during hypopnoeas) were identified as candidate predictors of CCCp (primary outcome variable, n=44/182), including inspiratory skewness and inspiratory scoopiness. Multivariable logistic regression combined the six characteristics to predict clear presence (n=22) versus absence (n=128) of CCCp (partial collapse and concurrent tongue base collapse excluded). Odds ratios for actual CCCp between predicted subgroups were quantified after cross-validation. Secondary analyses examined complete lateral wall, tongue base or epiglottis collapse. External validation was performed on a separate dataset (ntotal=466). RESULTS: CCCp was characterised by greater scoopiness (ß=1.5±0.6 per 2sd, multivariable estimate±se) and skewness (ß=11.4±2.4) compared with non-CCCp. The odds ratio for CCCp in predicted positive versus negative subgroups was 5.0 (95% CI 1.9-13.1). The same characteristics provided significant cross-validated prediction of lateral wall (OR 6.3, 95% CI 2.4-16.5), tongue base (OR 3.2, 95% CI 1.4-7.3) and epiglottis (OR 4.4, 95% CI 1.5-12.4) collapse. CCCp and lateral wall collapse shared similar characteristics (skewed, scoopy), diametrically opposed to tongue base and epiglottis collapse characteristics. External validation confirmed model prediction. CONCLUSIONS: The current study provides a means to recognise patients with likely CCCp or other DISE-based site of collapse categories using routine polysomnography. Since site of collapse influences therapeutic responses, polysomnographic airflow shape analysis could facilitate precision site-specific OSA interventions.


Assuntos
Endoscopia , Polissonografia , Apneia Obstrutiva do Sono , Humanos , Masculino , Feminino , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Pessoa de Meia-Idade , Adulto , Modelos Logísticos , Sono , Idoso , Língua/fisiopatologia , Faringe/fisiopatologia , Nervo Hipoglosso , Análise Multivariada , Palato , Epiglote/fisiopatologia , Pressão Positiva Contínua nas Vias Aéreas
6.
Eur Respir J ; 64(1)2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38575160

RESUMO

BACKGROUND: Pharyngeal flow limitation during pregnancy may be a risk factor for adverse pregnancy outcomes but was previously challenging to quantify. Our objective was to determine whether a novel objective measure of flow limitation identifies an increased risk of pre-eclampsia (primary outcome) and other adverse outcomes in a prospective cohort: Nulliparous Pregnancy Outcomes Study Monitoring Mothers-to-be (nuMoM2b). METHODS: Flow limitation severity scores (0%=fully obstructed, 100%=open airway), quantified from breath-by-breath airflow shape, were obtained from home sleep tests during early (6-15 weeks) and mid (22-31 weeks) pregnancy. Multivariable logistic regression quantified associations between flow limitation (median overnight severity, both time-points averaged) and pre-eclampsia, adjusting for maternal age, body mass index (BMI), race, ethnicity, chronic hypertension and flow limitation during wakefulness. Secondary outcomes were hypertensive disorders of pregnancy (HDP), gestational diabetes mellitus (GDM) and infant birthweight. RESULTS: Of 1939 participants with flow limitation data at both time-points (mean±sd age 27.0±5.4 years and BMI 27.7±6.1 kg·m-2), 5.8% developed pre-eclampsia, 12.7% developed HDP and 4.5% developed GDM. Greater flow limitation was associated with increased pre-eclampsia risk: adjusted OR 2.49 (95% CI 1.69-3.69) per 2sd increase in severity. Findings persisted in women without sleep apnoea (apnoea-hypopnoea index <5 events·h-1). Flow limitation was associated with HDP (OR 1.77 (95% CI 1.33-2.38)) and reduced infant birthweight (83.7 (95% CI 31.8-135.6) g), but not GDM. CONCLUSIONS: Greater flow limitation is associated with increased risk of pre-eclampsia, HDP and lower infant birthweight. Flow limitation may provide an early target for mitigating the consequences of sleep disordered breathing during pregnancy.


Assuntos
Pré-Eclâmpsia , Resultado da Gravidez , Humanos , Gravidez , Feminino , Adulto , Pré-Eclâmpsia/fisiopatologia , Estudos Prospectivos , Fatores de Risco , Adulto Jovem , Modelos Logísticos , Diabetes Gestacional/fisiopatologia , Sono/fisiologia , Peso ao Nascer , Análise Multivariada , Paridade , Polissonografia , Índice de Massa Corporal , Faringe/fisiopatologia , Hipertensão Induzida pela Gravidez/fisiopatologia , Recém-Nascido
7.
J Sleep Res ; 33(1): e13999, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37452710

RESUMO

Determining the endotypes of obstructive sleep apnea (OSA) has potential implications for precision interventions. Here we assessed whether continuous positive airway pressure (CPAP) treatment outcomes differ across endotypic subgroups. We conducted a retrospective analysis of data obtained from 225 patients with moderate-to-severe OSA from a single sleep centre. Polysomnographic and CPAP titration study data were collected between May 2020 and January 2022. One-month CPAP treatment adherence was followed. Obstructive sleep apnea endotypes, namely arousal threshold, collapsibility, loop gain, and upper airway gain were estimated from polysomnography and dichotomised as high versus low. We examined associations between endotypic subgroups and (1) optimal CPAP titration pressure, (2) CPAP-related improvements in sleep architecture (proportions of slow-wave and rapid eye movement (REM) sleep), and (3) CPAP adherence. We observed that patients with high collapsibility required a higher CPAP pressure than those with low collapsibility (∆ = 0.4 cmH2 O, 95% confidence interval [CI] = 0.3-1.7). A larger increase in slow-wave sleep and in REM sleep proportions after CPAP treatment were observed in patients with a high arousal threshold, high collapsibility, high loop gain, or high upper airway gain than in those with low levels of endotypes. High loop gain and high collapsibility were independently associated with longer CPAP use hours per night (∆ = 0.6 h, 95% CI = 0.2-1.5 and ∆ = 0.3 h, 95% CI = 0.03-1.5, respectively). In conclusion, different endotypic subgroups of OSA exhibit a difference in outcomes of CPAP treatment. Knowledge of endotypes may help clinicians to understand which patients are expected to benefit most from CPAP therapy prior to its administration.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Apneia Obstrutiva do Sono , Humanos , Estudos Retrospectivos , Apneia Obstrutiva do Sono/terapia , Sono , Polissonografia
8.
Am J Respir Crit Care Med ; 206(6): 767-774, 2022 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-35579605

RESUMO

Rationale: Randomized controlled trials of continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA) have not demonstrated protection against adverse cardiovascular outcomes. Recently, observational studies revealed that OSA-related cardiovascular risk is concentrated in patients with an elevated pulse rate response to respiratory events (ΔHR). Objectives: Here, in this post hoc analysis of a prospective clinical trial, we test the hypothesis that a greater pretreatment ΔHR is associated with greater CPAP-related protection against adverse cardiovascular outcomes. Methods: ΔHR was measured from baseline polysomnography of the RICCADSA (Randomized Intervention with CPAP in CAD and OSA) randomized controlled trial (patients with coronary artery disease [CAD] and OSA [apnea-hypopnea index ⩾ 15 events/h] with Epworth Sleepiness Scale score < 10; nCPAP:ncontrol = 113:113; male, 85%; age, 66 ± 8 [mean ± SD] yr). The primary outcome was a composite of repeat revascularization, myocardial infarction, stroke, and cardiovascular mortality. Multivariable Cox regression assessed whether the effect of CPAP was moderated by ΔHR (treatment-by-ΔHR interaction). Measurements and Main Results: The CPAP-related reduction in risk increased progressively with increasing pretreatment ΔHR (interaction hazard ratio [95% confidence interval], 0.49 [0.27 to 0.90] per SD increase in ΔHR; P < 0.05). This means that in patients with a ΔHR of 1 SD above the mean (i.e., 10 beats/min), CPAP was estimated to reduce cardiovascular risk by 59% (6% to 82%) (P < 0.05), but no significant risk reduction was estimated in patients with a mean ΔHR (6 beats/min; CPAP risk reduction, 16% [-53% to 54%]; P = 0.6). Conclusions: The protective effect of CPAP in patients with CAD and OSA without excessive sleepiness was modified by the ΔHR. Specifically, patients with higher ΔHR exhibit greater cardiovascular benefit from CPAP therapy.


Assuntos
Doença da Artéria Coronariana , Distúrbios do Sono por Sonolência Excessiva , Apneia Obstrutiva do Sono , Adulto , Idoso , Pressão Positiva Contínua nas Vias Aéreas , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/terapia , Sonolência , Resultado do Tratamento
9.
Am J Respir Crit Care Med ; 205(2): 219-232, 2022 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-34699338

RESUMO

Rationale: REM sleep is associated with reduced ventilation and greater obstructive sleep apnea (OSA) severity than non-REM (nREM) sleep for reasons that have not been fully elucidated. Objectives: Here, we use direct physiological measurements to determine whether the pharyngeal compromise in REM sleep OSA is most consistent with 1) withdrawal of neural ventilatory drive or 2) deficits in pharyngeal pathophysiology per se (i.e., increased collapsibility and decreased muscle responsiveness). Methods: Sixty-three participants with OSA completed sleep studies with gold standard measurements of ventilatory "drive" (calibrated intraesophageal diaphragm EMG), ventilation (oronasal "ventilation"), and genioglossus EMG activity. Drive withdrawal was assessed by examining these measurements at nadir drive (first decile of drive within a stage). Pharyngeal physiology was assessed by examining collapsibility (lowered ventilation at eupneic drive) and responsiveness (ventilation-drive slope). Mixed-model analysis compared REM sleep with nREM sleep; sensitivity analysis examined phasic REM sleep. Measurements and Main Results: REM sleep (⩾10 min) was obtained in 25 patients. Compared with drive in nREM sleep, drive in REM sleep dipped to markedly lower nadir values (first decile, estimate [95% confidence interval], -21.8% [-31.2% to -12.4%] of eupnea; P < 0.0001), with an accompanying reduction in ventilation (-25.8% [-31.8% to -19.8%] of eupnea; P < 0.0001). However, there was no effect of REM sleep on collapsibility (ventilation at eupneic drive), baseline genioglossus EMG activity, or responsiveness. REM sleep was associated with increased OSA severity (+10.1 [1.8 to 19.8] events/h), but this association was not present after adjusting for nadir drive (+4.3 [-4.2 to 14.6] events/h). Drive withdrawal was exacerbated in phasic REM sleep. Conclusions: In patients with OSA, the pharyngeal compromise characteristic of REM sleep appears to be predominantly explained by ventilatory drive withdrawal rather than by preferential decrements in muscle activity or responsiveness. Preventing drive withdrawal may be the leading target for REM sleep OSA.


Assuntos
Músculos Faciais/fisiopatologia , Hipotonia Muscular/fisiopatologia , Faringe/fisiopatologia , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Sono REM/fisiologia , Sono/fisiologia , Língua/fisiopatologia , Adulto , Idoso , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
Am J Respir Crit Care Med ; 206(10): 1271-1280, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-35822943

RESUMO

Rationale: Obstructive sleep apnea (OSA) is a common disorder associated with increased risk for cardiovascular disease, diabetes, and premature mortality. There is strong clinical and epidemiologic evidence supporting the importance of genetic factors influencing OSA but limited data implicating specific genes. Objectives: To search for rare variants contributing to OSA severity. Methods: Leveraging high-depth genomic sequencing data from the NHLBI Trans-Omics for Precision Medicine (TOPMed) program and imputed genotype data from multiple population-based studies, we performed linkage analysis in the CFS (Cleveland Family Study), followed by multistage gene-based association analyses in independent cohorts for apnea-hypopnea index (AHI) in a total of 7,708 individuals of European ancestry. Measurements and Main Results: Linkage analysis in the CFS identified a suggestive linkage peak on chromosome 7q31 (LOD = 2.31). Gene-based analysis identified 21 noncoding rare variants in CAV1 (Caveolin-1) associated with lower AHI after accounting for multiple comparisons (P = 7.4 × 10-8). These noncoding variants together significantly contributed to the linkage evidence (P < 10-3). Follow-up analysis revealed significant associations between these variants and increased CAV1 expression, and increased CAV1 expression in peripheral monocytes was associated with lower AHI (P = 0.024) and higher minimum overnight oxygen saturation (P = 0.007). Conclusions: Rare variants in CAV1, a membrane-scaffolding protein essential in multiple cellular and metabolic functions, are associated with higher CAV1 gene expression and lower OSA severity, suggesting a novel target for modulating OSA severity.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Caveolina 1/genética , Apneia Obstrutiva do Sono/genética , Análise de Sequência de DNA , Sequenciamento de Nucleotídeos em Larga Escala
11.
Sleep Breath ; 27(2): 495-503, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35551600

RESUMO

PURPOSE: Preliminary studies have shown a significant decrease in severity of obstructive sleep apnea (OSA) with the use of a combination of atomoxetine and oxybutynin, with patients having moderate pharyngeal collapsibility during sleep more likely to respond. This study evaluated the efficacy and safety of AD036 (atomoxetine 80 mg and oxybutynin 5 mg) in the treatment of OSA. METHODS: This trial was a phase 2, randomized, placebo-controlled crossover study comparing AD036, atomoxetine 80 mg alone, and placebo during three home sleep studies, each separated by about 1 week. The trial included patients with OSA and moderate pharyngeal collapsibility as defined by a higher proportion of hypopneas to apneas and mild oxygen desaturation. RESULTS: Of 62 patients who were randomized, 60 were included in efficacy analyses. The apnea-hypopnea index (AHI) from a median (interquartile range) of 14.2 (5.4 to 22.3) events/h on placebo to 6.2 (2.8 to 13.6) with AD036 and 4.8 (1.4 to 11.6) with atomoxetine alone (p < .0001). Both drugs also decreased the oxygen desaturation index (ODI) and the hypoxic burden (p < .0001). AD036, but not atomoxetine alone, reduced the respiratory arousal index and improved ventilation at the respiratory arousal threshold (greater Vactive). There was a trend for total sleep time to be decreased more with atomoxetine alone than with AD036. The most common adverse event was insomnia (12% with AD036, 18% with atomoxetine). CONCLUSION: AD036 significantly improved OSA severity in patients with moderate pharyngeal collapsibility. Atomoxetine may account for the majority of improvement in OSA severity, while the addition of oxybutynin may mitigate the disruptive effect of atomoxetine on sleep and further improve ventilation. TRIAL REGISTRATION: Clinical trial registered with www. CLINICALTRIALS: gov (NCT04445688).


Assuntos
Apneia Obstrutiva do Sono , Humanos , Cloridrato de Atomoxetina/farmacologia , Cloridrato de Atomoxetina/uso terapêutico , Estudos Cross-Over , Sono
12.
Thorax ; 77(7): 707-716, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35064045

RESUMO

BACKGROUND: In the classic model of obstructive sleep apnoea (OSA), respiratory events occur with sleep-related dilator muscle hypotonia, precipitating increased neural ventilatory 'drive'. By contrast, a drive-dependent model has been proposed, whereby falling drive promotes dilator muscle hypotonia to precipitate respiratory events. Here we determine the extent to which the classic versus drive-dependent models of OSA are best supported by direct physiological measurements. METHODS: In 50 OSA patients (5-91 events/hour), we recorded ventilation ('flow', oronasal mask and pneumotach) and ventilatory drive (calibrated intraoesophageal diaphragm electromyography, EMG) overnight. Flow and drive during events were ensemble averaged; patients were classified as drive dependent if flow fell/rose simultaneously with drive. Overnight effects of lower drive on flow, genioglossus muscle activity (EMGgg) and event risk were quantified (mixed models). RESULTS: On average, ventilatory drive fell (rather than rose) during events (-20 (-42 to 3)%baseline, median (IQR)) and was strongly correlated with flow (R=0.78 (0.24 to 0.94)). Most patients (30/50, 60%) were classified as exhibiting drive-dependent event pathophysiology. Lower drive during sleep was associated with lower flow (-17 (-20 to -14)%/drive) and EMGgg (-3.5 (-3.8 to -3.3)%max/drive) and greater event risk (OR: 2.2 (1.8 to 2.5) per drive reduction of 100%eupnoea); associations were concentrated in patients with drive-dependent OSA (ie, flow: -37 (-40 to -34)%/drive, OR: 6.8 (5.3 to 8.7)). Oesophageal pressure-without tidal volume correction-falsely suggested rising drive during events (classic model). CONCLUSIONS: In contrast to the prevailing view, patients with OSA predominantly exhibit drive-dependent event pathophysiology, whereby flow is lowest at nadir drive, and lower drive raises event risk. Preventing ventilatory drive decline is therefore considered a target for OSA intervention.


Assuntos
Hipotonia Muscular , Apneia Obstrutiva do Sono , Diafragma , Humanos , Hipotonia Muscular/complicações , Polissonografia , Respiração , Sono , Apneia Obstrutiva do Sono/complicações
13.
Pediatr Res ; 92(1): 255-264, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34552200

RESUMO

INTRODUCTION: Maternal-infant equilibrium occurs when cord blood docosahexaenoic acid (DHA) is less than or equal to maternal DHA at delivery. Equilibrium may be an indicator of sufficient DHA for optimal fetal and infant neurodevelopment. The purpose of this study was to test the effect of maternal DHA supplementation on equilibrium status and fetal neurodevelopment. METHODS: Women enrolled between 12 and 20 weeks gestation and were randomized to 200 or 800 mg DHA/day until delivery. Maternal red blood cell (RBC) phospholipids were measured at enrollment, 32 weeks, delivery, and in cord blood at delivery. Fetal neurodevelopment was measured at 32 and 36 weeks gestation. Intent-to-treat analyses were conducted to test differences in equilibrium status by group. Fetal outcomes were assessed by equilibrium status and group. RESULTS: Three hundred women enrolled and 262 maternal-infant dyads provided blood samples at delivery. No maternal-infant dyads with maternal RBC-DHA ≤ 6.96% at delivery achieved equilibrium. The incidence of equilibrium was significantly higher in the 800 mg group. There was no effect of maternal group or equilibrium status on fetal neurodevelopment. CONCLUSION: The significance of maternal-infant DHA equilibrium remains unknown. Ongoing research will test the effect of treatment group, equilibrium, and nutrient status on infant behavior and brain function. IMPACT: Pregnant women who received a higher dose of docosahexaenoic acid (DHA) were more likely to achieve maternal-infant DHA equilibrium at delivery. Equilibrium status had no effect on fetal neurodevelopment in this sample. While DHA is crucial for early life neurodevelopment, the significance of achieving maternal-infant equilibrium above the lower threshold is uncertain. There is a lower threshold of maternal DHA status where maternal-infant DHA equilibrium never occurs. The lack of equilibrium associated with low maternal DHA status may indicate insufficient maternal status for optimal placental transfer.


Assuntos
Ácidos Docosa-Hexaenoicos , Placenta , Suplementos Nutricionais , Feminino , Sangue Fetal , Humanos , Lactente , Gravidez , Cuidado Pré-Natal , Vitaminas
14.
Respirology ; 27(11): 975-982, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35811347

RESUMO

BACKGROUND AND OBJECTIVE: The combination of the noradrenergic atomoxetine plus the anti-muscarinic oxybutynin acutely increased genioglossus activity and reduced obstructive sleep apnoea (OSA) severity. However, oxybutynin has shorter half-life than atomoxetine and side effects that might discourage long-term usage. Accordingly, we aimed to test the combination of atomoxetine and fesoterodine (Ato-Feso), a newer anti-muscarinic with extended release formulation, on OSA severity and endotypes. METHODS: Twelve subjects with OSA underwent a randomized, double-blind, crossover trial comparing one night of atomoxetine plus fesoterodine (80-4 mg) to placebo. Parameters of OSA severity (e.g., apnoea-hypopnoea index [AHI], nadir oxygen desaturation and hypoxic burden) were calculated from two clinical, in-lab polysomnographic studies. OSA endotypes (including collapsibility per VMIN and arousal threshold) were derived from validated algorithms. RESULTS: Compared to placebo, Ato-Feso did not reduce the AHI (34.2 ± 19.1 vs. 30.1 ± 28.2 events/h, p = 0.493), but reduced the apnoea index (12.9 [28.8] vs. 1.8 [9.1] events/h, median [interquartile range], p = 0.027) and increased nadir desaturation (76.8 [8.0] vs. 82.2 [8.8] %, p = 0.003); a non-significant trend for improved hypoxic burden was observed (52.4 [50.5] vs. 29.7 [78.9] %min/h, p = 0.093). Ato-Feso lowered collapsibility (raised VMIN ; 43.7 [29.8-55.7] vs. 56.8 [43.8-69.8] %VEUPNOEA , mean [CI], p = 0.002), but reduced the arousal threshold (129.3 [120.1-138.6] vs. 116.7 [107.5-126] %VEUPNOEA , p = 0.038). In post hoc analysis, 6/6 patients with milder collapsibility (VMIN > 43%) exhibited OSA resolution (drop in AHI > 50% and residual AHI < 10 events/h) and improved hypoxaemia. CONCLUSION: While inefficacious in unselected patients, Ato-Feso administered for one night suppressed OSA in patients with milder collapsibility. Ato-Feso may hold some promise as an alternative OSA treatment in certain subgroups of individuals.


Assuntos
Apneia Obstrutiva do Sono , Cloridrato de Atomoxetina/farmacologia , Cloridrato de Atomoxetina/uso terapêutico , Compostos Benzidrílicos , Preparações de Ação Retardada/uso terapêutico , Humanos , Ácidos Mandélicos , Oxigênio , Apneia Obstrutiva do Sono/tratamento farmacológico
15.
Respirology ; 27(10): 890-899, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35598093

RESUMO

BACKGROUND AND OBJECTIVE: Upper airway surgery for obstructive sleep apnoea (OSA) is an alternative treatment for patients who are intolerant of continuous positive airway pressure (CPAP). However, upper airway surgery has variable treatment efficacy with no reliable predictors of response. While we now know that there are several endotypes contributing to OSA (i.e., upper airway collapsibility, airway muscle response/compensation, respiratory arousal threshold and loop gain), no study to date has examined: (i) how upper airway surgery affects all four OSA endotypes, (ii) whether knowledge of baseline OSA endotypes predicts response to surgery and (iii) whether there are any differences when OSA endotypes are measured using the CPAP dial-down or clinical polysomnographic (PSG) methods. METHODS: We prospectively studied 23 OSA patients before and ≥3 months after multilevel upper airway surgery. Participants underwent clinical and research PSG to measure OSA severity (apnoea-hypopnoea index [AHI]) and endotypes (measured in supine non-rapid eye movement [NREM]). Values are presented as mean ± SD or median (interquartile range). RESULTS: Surgery reduced the AHITotal (38.7 [23.4 to 79.2] vs. 22.0 [13.3 to 53.5] events/h; p = 0.009). There were no significant changes in OSA endotypes, however, large but variable improvements in collapsibility were observed (CPAP dial-down method: ∆1.9 ± 4.9 L/min, p = 0.09, n = 21; PSG method: ∆3.4 [-2.8 to 49.0]%Veupnoea , p = 0.06, n = 20). Improvement in collapsibility strongly correlated with improvement in AHI (%∆AHISupineNREM vs. ∆collapsibility: p < 0.005; R2  = 0.46-0.48). None of the baseline OSA endotypes predicted response to surgery. CONCLUSION: Surgery unpredictably alters upper airway collapsibility but does not alter the non-anatomical endotypes. There are no baseline predictors of response to surgery.


Assuntos
Apneia Obstrutiva do Sono , Nível de Alerta/fisiologia , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Sistema Respiratório/cirurgia , Resultado do Tratamento
16.
Am J Respir Crit Care Med ; 203(9): 1173-1182, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33285084

RESUMO

Rationale: Symptoms and morbidities associated with obstructive sleep apnea (OSA) vary across individuals and are not predicted by the apnea-hypopnea index (AHI). Respiratory event duration is a heritable trait associated with mortality that may further characterize OSA.Objectives: We evaluated how hypopnea and apnea durations in non-REM (NREM) sleep vary across demographic groups and quantified their associations with physiological traits (loop gain, arousal threshold, circulatory delay, and pharyngeal collapsibility).Methods: Data were analyzed from 1,546 participants from the Multi-Ethnic Study of Atherosclerosis with an AHI ≥5. Physiological traits were derived using a validated model fit to the polysomnographic airflow signal. Multiple linear regression models were used to evaluate associations of event duration with demographic and physiological factors.Measurements and Main Results: Participants had a mean age ± SD of 68.9 ± 9.2 years, mean NREM hypopnea duration of 21.73 ± 5.60, and mean NREM apnea duration of 23.87 ± 7.44 seconds. In adjusted analyses, shorter events were associated with younger age, female sex, higher body mass index (P < 0.01, all), and Black race (P < 0.05). Longer events were associated with Asian race (P < 0.01). Shorter event durations were associated with lower circulatory delay (2.53 ± 0.13 s, P < 0.01), lower arousal threshold (1.39 ± 0.15 s, P < 0.01), reduced collapsibility (-0.71 ± 0.16 s, P < 0.01), and higher loop gain (-0.27 ± 0.11 s, P < 0.05) per SD change. Adjustment for physiological traits attenuated age, sex, and obesity associations and eliminated racial differences in event duration.Conclusions: Average event duration varies across population groups and provides information on ventilatory features and airway collapsibility not captured by the AHI.


Assuntos
Etnicidade/estatística & dados numéricos , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/fisiopatologia , Sono REM/fisiologia , População Branca/estatística & dados numéricos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Nível de Alerta , Índice de Massa Corporal , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Faringe/fisiopatologia , Polissonografia , Taxa Respiratória , Fatores de Risco , Fatores Sexuais , Apneia Obstrutiva do Sono/diagnóstico , Fatores de Tempo
17.
Am J Respir Crit Care Med ; 204(6): 703-712, 2021 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-34156917

RESUMO

Rationale: Untreated obstructive sleep apnea (OSA) is associated with adverse outcomes in patients with coronary artery disease (CAD). Continuous positive airway pressure (CPAP) is the most common treatment, but despite interventions addressing established adherence determinants, CPAP use remains poor. Objectives: To determine whether physiological traits that cause OSA are associated with long-term CPAP adherence in patients with CAD. Methods: Participants in the RICCADSA (Randomized Intervention with CPAP in CAD and OSA) trial with objective CPAP adherence (h/night) over 2 years and analyzable raw polysomnography data were included (N = 249). The physiological traits-loop gain, arousal threshold (ArTH), pharyngeal collapsibility (Vpassive), and pharyngeal muscle compensation (Vcomp)-were measured by using polysomnography. Linear mixed models were used to assess the relationship between the traits and adherence. We also compared actual CPAP adherence between those with physiologically predicted "poor" adherence (lowest quartile of predicted adherence) and those with physiologically predicted "good" adherence (all others). Measurements and Main Results: The median (interquartile range) CPAP use declined from 3.2 (1.0-5.8) h/night to 3.0 (0.0-5.6) h/night over 24 months (P < 0.001). In analyses adjusted for demographics, anthropometrics, OSA characteristics, and clinical comorbidities, a lower ArTH was associated with worse CPAP adherence (0.7 h/SD of the ArTH; P = 0.021). Both high and low Vcomp were associated with lower adherence (P = 0.008). Those with predicted poor adherence exhibited markedly lower CPAP use than those with predicted good adherence for up to 2 years of follow-up (group differences of 2.0-3.2 h/night; P < 0.003 for all). Conclusions: A low ArTH, as well as a very low and high Vcomp, are associated with worse long-term CPAP adherence in patients with CAD and OSA. Physiological traits-alongside established determinants-may help predict and improve CPAP adherence. Clinical trial registered with www.clinicaltrials.gov (NCT00519597).


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Doença da Artéria Coronariana/complicações , Cooperação do Paciente , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Idoso , Feminino , Seguimentos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente/estatística & dados numéricos , Polissonografia , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/psicologia
18.
Am J Respir Crit Care Med ; 203(6): 746-755, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-32970962

RESUMO

Rationale: Approximately one-third of patients with obstructive sleep apnea (OSA) treated with hypoglossal nerve stimulation (HGNS) therapy are incomplete responders, despite careful patient selection based on baseline characteristics and drug-induced sleep endoscopy.Objectives: Here we use polysomnographic endotyping to assess the pathophysiological mechanisms underlying favorable versus incomplete responses to HGNS therapy.Methods: Baseline polysomnography data of the STAR (Stimulation Therapy for Apnea Reduction) trial were included. Raw baseline polysomnographic data from 91/126 patients were available for analysis. Traits-loop gain, arousal threshold, collapsibility, and muscle compensation-were calculated from the baseline polysomnography data according to Sands and colleagues (AJRCCM 2018, SLEEP 2018). Logistic regression assessed apnea-hypopnea index (AHI)-adjusted associations between HGNS response (>50% reduction in AHI to <10/h at 1 yr) and OSA traits.Measurements and Main Results: Overall, HGNS treatment reduced AHI from 30.7 (24.9-39.9) to 8.5 (4.0-19.5) events/h (P < 0.0001; median [quartiles 1-3]); N = 53/91 were responders. In adjusted analysis, a favorable response to therapy was independently associated with higher arousal threshold (odds ratio [95% confidence interval]: 6.76 [2.44-23.3], P = 0.001), greater compensation (odds ratio: 4.22 [1.70-12.55] per SD, P = 0.004), and lower loop gain (in milder collapsibility, per significant interaction, P = 0.003). The higher arousal threshold was evident in responders before adjusted analysis. Predicted responders had an approximately fourfold lower treatment AHI versus predicted nonresponders (4.9 [2.7-8.5] vs. 20.7 [10.9-29.7], P < 0.0001; median [quartiles 1-3]); differences remained significant after cross-validation.Conclusions: Favorable responses to HGNS therapy are associated with the pathophysiological traits causing OSA, particularly a higher arousal threshold. Along with established criteria, individuals with favorable traits could potentially be prioritized for precision HGNS therapy.This analysis was a secondary analysis of the STAR trial registered with clinicaltrials.gov (NCT01161420).


Assuntos
Nervo Hipoglosso/fisiologia , Apneia Obstrutiva do Sono/terapia , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
19.
Am J Respir Crit Care Med ; 203(12): 1546-1555, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33406013

RESUMO

Rationale: Randomized controlled trials have been unable to detect a cardiovascular benefit of continuous positive airway pressure in unselected patients with obstructive sleep apnea (OSA). We hypothesize that deleterious cardiovascular outcomes are concentrated in a subgroup of patients with a heightened pulse-rate response to apneas and hypopneas (ΔHR). Methods: We measured the ΔHR in the MESA (Multi-Ethnic Study of Atherosclerosis) (N = 1,395) and the SHHS (Sleep Heart Health Study) (N = 4,575). MESA data were used to determine the functional form of the association between the ΔHR and subclinical cardiovascular biomarkers, whereas primary analyses tested the association of the ΔHR with nonfatal or fatal cardiovascular disease (CVD) and all-cause mortality in longitudinal data from the SHHS. Measurements and Main Results: In the MESA, U-shaped relationships were observed between subclinical CVD biomarkers (coronary artery calcium, NT-proBNP [N-terminal prohormone BNP], and Framingham risk score) and the ΔHR; notably, a high ΔHR (upper quartile) was associated with elevated biomarker scores compared with a midrange ΔHR (25th-75th centiles). In the SHHS, individuals with a high ΔHR compared with a midrange ΔHR were at increased risk of nonfatal or fatal CVD and all-cause mortality (nonfatal adjusted hazard ratio [95% confidence interval (CI)], 1.60 [1.28-2.00]; fatal adjusted hazard ratio [95% CI], 1.68 [1.22-2.30]; all-cause adjusted hazard ratio [95% CI], 1.29 [1.07-1.55]). The risk associated with a high ΔHR was particularly high in those with a substantial hypoxic burden (nonfatal, 1.93 [1.36-2.73]; fatal, 3.50 [2.15-5.71]; all-cause, 1.84 [1.40-2.40]) and was exclusively observed in nonsleepy individuals. Conclusions: Individuals with OSA who demonstrate an elevated ΔHR are at increased risk of cardiovascular morbidity and mortality. This study identifies a prognostic biomarker for OSA that appears useful for risk stratification and patient selection for future clinical trials.


Assuntos
Biomarcadores , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Frequência Cardíaca , Prognóstico , Medição de Risco/métodos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade
20.
Am J Respir Crit Care Med ; 203(6): e11-e24, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33719931

RESUMO

Background: Central sleep apnea (CSA) is common among patients with heart failure and has been strongly linked to adverse outcomes. However, progress toward improving outcomes for such patients has been limited. The purpose of this official statement from the American Thoracic Society is to identify key areas to prioritize for future research regarding CSA in heart failure.Methods: An international multidisciplinary group with expertise in sleep medicine, pulmonary medicine, heart failure, clinical research, and health outcomes was convened. The group met at the American Thoracic Society 2019 International Conference to determine research priority areas. A statement summarizing the findings of the group was subsequently authored using input from all members.Results: The workgroup identified 11 specific research priorities in several key areas: 1) control of breathing and pathophysiology leading to CSA, 2) variability across individuals and over time, 3) techniques to examine CSA pathogenesis and outcomes, 4) impact of device and pharmacological treatment, and 5) implementing CSA treatment for all individualsConclusions: Advancing care for patients with CSA in the context of heart failure will require progress in the arenas of translational (basic through clinical), epidemiological, and patient-centered outcome research. Given the increasing prevalence of heart failure and its associated substantial burden to individuals, society, and the healthcare system, targeted research to improve knowledge of CSA pathogenesis and treatment is a priority.


Assuntos
Pesquisa Biomédica/estatística & dados numéricos , Pesquisa Biomédica/tendências , Insuficiência Cardíaca , Projetos de Pesquisa/tendências , Apneia do Sono Tipo Central , Sociedades Médicas/estatística & dados numéricos , Sociedades Médicas/tendências , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Projetos de Pesquisa/estatística & dados numéricos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA