Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Pediatr Diabetes ; 20(6): 794-799, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31140654

RESUMO

OBJECTIVE: To evaluate the experiences of families with very young children aged 1 to 7 years (inclusive) with type 1 diabetes using day-and-night hybrid closed-loop insulin delivery. METHODS: Parents/caregivers of 20 children aged 1 to 7 years with type 1 diabetes completed a closed-loop experience survey following two 3-week periods of unrestricted day-and-night hybrid closed-loop insulin therapy using Cambridge FlorenceM system at home. Benefits, limitations, and improvements of closed-loop technology were explored. RESULTS: Responders reported reduced burden of diabetes management, less time spent managing diabetes, and improved quality of sleep with closed-loop. Ninety percent of the responders felt less worried about their child's glucose control using closed-loop. Size of study devices, battery performance and connectivity issues were identified as areas for improvement. Parents/caregivers wished for more options to input information to the system such as temporary glucose targets. CONCLUSIONS: Parents/caregivers of very young children reported important quality of life benefits associated with using closed-loop, supporting adoption of this technology in this population.


Assuntos
Efeitos Psicossociais da Doença , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Qualidade de Vida , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia , Cuidadores/psicologia , Cuidadores/estatística & dados numéricos , Criança , Pré-Escolar , Ritmo Circadiano/fisiologia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/epidemiologia , Diabetes Mellitus Tipo 1/psicologia , Família/psicologia , Feminino , Humanos , Lactente , Insulina/efeitos adversos , Masculino , Pais/psicologia , Inquéritos e Questionários
2.
Front Endocrinol (Lausanne) ; 12: 721028, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34456876

RESUMO

Background: Type 1 diabetes in young children is a heavy parental burden. As part of pilot phase of the KIDSAP01 study, we conducted a baseline assessment in parents to study the association between hypoglycemia fear, parental well-being and child behavior. Methods: All parents were invited to fill in baseline questionnaires: hypoglycemia fear survey (HFS), WHO-5, Epworth Sleepiness Scale and Strength and Difficulties Questionnaire (SDQ). Results: 24 children (median age: 5-year, range 1-7 years, 63% male, mean diabetes duration: 3 ± 1.7 years) participated. 23/24 parents filled out the questionnaires. We found a higher score for the hypoglycemia fear behavior 33.9 ± 5.6 compared to hypoglycemia worry 34.6 ± 12.2. Median WHO-5 score was 16 (8 - 22) with poor well-being in two parents. Median daytime sleepiness score was high in five parents (>10). For six children a high total behavioral difficulty score (>16) was reported. Pro social behavior score was lower than normal in six children (<6). Parental well-being was negatively associated with HFS total (r = - 0.50, p <.05) and subscale scores (r = - 0.44, p <.05 for HFS-Worry and HFS-Behavior), child behavior (r = - 0.45, p = .05) and positively with child age and diabetes duration (r = 0.58, p <.01, r = 0.6, p <.01). HFS, parental well-being nor daytime sleepiness are associated with the HbA1c. Conclusion: Regular screening of parental well-being, hypoglycemia fear and child behavior should be part of routine care to target early intervention.


Assuntos
Diabetes Mellitus Tipo 1/psicologia , Pais/psicologia , Adulto , Idade de Início , Ansiedade/epidemiologia , Ansiedade/psicologia , Criança , Comportamento Infantil/psicologia , Pré-Escolar , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Europa (Continente)/epidemiologia , Medo/psicologia , Feminino , Humanos , Hipoglicemia/prevenção & controle , Hipoglicemia/psicologia , Lactente , Insulina/administração & dosagem , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Masculino , Inquéritos e Questionários
3.
Diabetes Care ; 42(4): 594-600, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30692242

RESUMO

OBJECTIVE: We aimed to assess the feasibility and safety of hybrid closed-loop insulin delivery in children with type 1 diabetes aged 1-7 years as well as evaluate the role of diluted insulin on glucose control. RESEARCH DESIGN AND METHODS: In an open-label, multicenter, multinational, randomized crossover study, 24 children with type 1 diabetes on insulin pump therapy (median age 5 years [interquartile range 3-6] and mean ± SD HbA1c 7.4 ± 0.7% [57 ± 8 mmol/mol] and total insulin 13.2 ± 4.8 units/day) underwent two 21-day periods of unrestricted living and we compared hybrid closed-loop with diluted insulin (U20) and hybrid closed-loop with standard strength insulin (U100) in random order. During both interventions, the Cambridge model predictive control algorithm was used. RESULTS: The proportion of time that sensor glucose was in the target range between 3.9 and 10 mmol/L (primary end point) was not different between interventions (mean ± SD 72 ± 8% vs. 70 ± 7% for closed-loop with diluted insulin vs. closed-loop with standard insulin, respectively; P = 0.16). There was no difference in mean glucose levels (8.0 ± 0.8 vs. 8.2 ± 0.6 mmol/L; P = 0.14), glucose variability (SD of sensor glucose 3.1 ± 0.5 vs. 3.2 ± 0.4 mmol/L; P = 0.16), or the proportion of time spent with sensor glucose <3.9 mmol/L (4.5 ± 1.7% vs. 4.7 ± 1.4%; P = 0.47) or <2.8 mmol/L (0.6 ± 0.5% vs. 0.6 ± 0.4%; P > 0.99). Total daily insulin delivery did not differ (17.3 ± 5.6 vs. 18.9 ± 6.9 units/day; P = 0.07). No closed-loop-related severe hypoglycemia or ketoacidosis occurred. CONCLUSIONS: Unrestricted home use of day-and-night closed-loop in very young children with type 1 diabetes is feasible and safe. The use of diluted insulin during closed-loop does not provide additional benefits compared with standard strength insulin.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Algoritmos , Glicemia , Criança , Pré-Escolar , Estudos Cross-Over , Feminino , Humanos , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Lactente , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA