Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Klin Monbl Augenheilkd ; 241(6): 772-779, 2024 Jun.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-38134909

RESUMO

BACKGROUND: The most important tool in glaucoma therapy is to lower the intraocular pressure to slow down the apoptosis of retinal ganglion cells. Trabeculectomy (TE) is considered the gold standard in glaucoma surgery. The aim of this study was to analyse the postoperative changes in retinal nerve fibre layer (RNFL) using optical coherence tomography (OCT) after TE. MATERIAL AND METHODS: We examined 40 patients naïve to prior glaucoma surgery retrospectively, who received a TE for medically uncontrolled primary open-angle glaucoma (POAG). Intraocular pressure (IOP), IOP-lowering medication, mean deviation of perimetry, visual acuity and peripapillary RNFL-thickness using OCT were evaluated during the first 24 month after TE. RESULTS: In total 40 eyes from 40 patients were treated with TE. Mean IOP decreased from 25.0 ± 0,9 to 13.9 ± 0.6 (p < 0.01), and the mean number of IOP-lowering eye drops from 3.3 ± 0.2 to 0.5 ± 0.2 (p < 0.01). Visual acuity and mean deviation in perimetry remained stable while mean global RNFL-thickness decreased from 67.8 ± 2.9 to 63.7 ± 2.9 (p < 0.01) and 63.4 ± 2.9 µm (p < 0.01) 12 and 24 months after TE. CONCLUSION: The TE is an effective method to reduce the IOD and the amount of IOP-lowering medication. Nevertheless, a significant further loss in RNFL thickness was observed in the first 12 months after TE. Thus, RNFL changes seem to stabilise only after a protracted period.


Assuntos
Glaucoma de Ângulo Aberto , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Trabeculectomia , Humanos , Trabeculectomia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/fisiopatologia , Células Ganglionares da Retina/patologia , Pressão Intraocular/fisiologia , Estudos Retrospectivos , Fibras Nervosas/patologia , Acuidade Visual , Estudos Longitudinais , Reprodutibilidade dos Testes
2.
Klin Monbl Augenheilkd ; 239(1): 86-93, 2022 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-34571551

RESUMO

BACKGROUND: Trabeculectomy (TE) has been the standard procedure in glaucoma surgery for a long time. This study examined the efficacy and safety profile of XEN45 Gel Stent (XEN) after failed and/or scarred trabeculectomy. MATERIAL AND METHODS: We analysed all files of patients, who received a XEN after insufficient TE and examined changes in intraocular pressure (IOP), IOP-lowering medication, best corrected visual acuity, visual field tests as well as the intra- and postoperative complications recorded within a 12-month follow-up period. RESULTS: 31 eyes of 28 patients were analysed in our study (mean age: 66,2 ± 13,4 years; 39% female; 48% right eye; mean follow-up after TE: 70,3 ± 64,9 months). The mean IOP decreased from 23,5 ± 6,5 to 18,0 ± 5,3 mmHg (- 23,5% compared to baseline-IOP; p = 0,01) while the mean IOP-lowering medication could be reduced from 2,8 ± 1,1 to 1,1 ± 1,5 (p < 0,01) 12 months after XEN-implantation. The mean visual acuity did not change significantly (pre-op: 0,5 ± 0,6 logMAR; 12 months post-op: 0,5 ± 0,6 logMAR). The most common complications postoperatively were choroideal detachment due to postoperative hypotony in 4 eyes (13%), a needling procedure in 9 eyes (29%), a Re-XEN-Implantation in 4 eyes (13%), an open revision of the conjunctiva in 3 eyes (10%), and a Re-TE in 1 eye (3%) as well as an Ahmed-Valve implantation in 2 eyes (6%). Overall, neither needling procedure nor further glaucoma surgery was necessary in 19 eyes (61%). In 10 of 22 evaluable eyes (45%) an IOP reduction of > 20% was achieved 12 months after XEN implantation. CONCLUSION: XEN could be an effective method to reduce IOP after failed TE. The rate of complications seems to be low and the rate of needling procedures and/or revisions is acceptable.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Trabeculectomia , Feminino , Seguimentos , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Recém-Nascido , Pressão Intraocular , Masculino , Implantação de Prótese , Estudos Retrospectivos , Stents , Tonometria Ocular , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA