Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Clin Res Cardiol ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353680

RESUMO

BACKGROUND: Transcatheter edge-to-edge mitral valve repair (M-TEER) is often performed in general anesthesia, and postprocedural monitoring is usually warranted on an intensive or intermediate care unit (ICU/IMC). We evaluated the implications of a dedicated valve unit (VU) instead of an ICU/IMC for monitoring after M-TEER. METHODS AND RESULTS: In total, 624 patients were retrospectively analyzed. A total of 312 patients were primarily transferred to either ICU or IMC following M-TEER, and 312 patients were scheduled for the VU in the absence of indications for ICU/IMC treatment. Hospital stay was significantly shorter in VU patients (median 6.0 days (interquartile range (IQR) 5.0 - 8.0) vs. 7.0 days (IQR 6.0 - 10.0), p < 0.001) and their risk for infections (2.9 vs. 7.7%, p = 0.008) and delirium (0.6 vs. 2.6%, p = 0.056) was substantially lower compared to ICU/IMC patients. In-hospital mortality was similar in both groups (0.6% vs. 1.3%, p = 0.41). Fifty patients (16.0%) in the VU group had to cross over to unplanned ICU/IMC admission. The most frequent indication was prolonged need for catecholamines (52.0%). Patients with ICU/IMC crossover had more advanced stages of heart failure (LV-EF < 30% in 36.0 vs. 16.0%, p = 0.001; severe concomitant tricuspid regurgitation in 48.0 vs. 27.8%, p = 0.005) and an LV-EF < 30% was independently associated with unplanned ICU/IMC admission. CONCLUSIONS: Following M-TEER postprocedural monitoring on a VU instead of an ICU/IMC is safe, reduces complications, and spares ICU capacities. Patients with advanced heart failure have a higher risk for unplanned ICU/IMC treatment after M-TEER.

2.
J Clin Med ; 13(8)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38673445

RESUMO

(1) Objective: We aimed to assess whether the candidate profile, the long-term outcomes and the predictors for long-term mortality after transcatheter edge-to-edge mitral valve repair (M-TEER) have changed over the last decade; (2) Methods: Long-term follow-up data (median time of 1202 days) including mortality, MACCE and functional status were available for 677 consecutive patients enrolled in the prospective MiTra Ulm registry from January 2010 to April 2019. The initial 340 patients treated in our institution before January 2016 were compared with the following 337 patients; (3) Results: Patients treated after 2016 showed significantly less ventricular dilatation (left ventricular end-systolic diameter of 43 ± 13 mm vs. 49 ± 16 mm, p < 0.007), lower systolic pulmonary pressures (50 ± 15 mmHg vs. 57 ± 21 mmHg, p = 0.01) and a lower prevalence of severe tricuspid regurgitation (27.2% vs. 47.3%, p < 0.001) at baseline than patients treated before 2016. Compared to the cohort treated before 2016, patients treated afterwards showed a significantly lower all-cause 3-year mortality (29.4% vs. 43.8%, p < 0.001) and lower MACCE (38.6% vs. 54.1%, p < 0.001), without differences for MR etiology. While severe tricuspid regurgitation and NYHA class IV remained independently associated with an increased long-term mortality over the last decade, severe left ventricular dilatation (hazard ratio, HR 2.12, p = 0.047) and severe pulmonary hypertension (HR 2.18, p = 0.047) were predictors of long-term mortality only in patients treated before 2016. (4) Conclusions: The M-TEER candidates are currently treated earlier in the course of disease and benefit significantly in terms of a better long-term survival than patients treated at the beginning of the M-TEER era.

3.
Clin Res Cardiol ; 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38270636

RESUMO

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is an established treatment for functional mitral regurgitation (FMR) associated with a risk of creating iatrogenic stenosis. OBJECTIVES: To investigate the impact of the P10 and its larger spacer compared to the narrower Ace and its smaller spacer on reduction of mitral valve orifice area (MVOA) during M-TEER. METHODS: Consecutive patients undergoing M-TEER for treatment of severe FMR were screened retrospectively. Patients with a single PASCAL device implantation within the central segments of the MV leaflets, non-complex anatomy, and baseline MVOA ≥ 3.5cm2 were selected. Intraprocedural transesophageal echocardiography was used to compare MVOA reduction with 3D multiplanar reconstruction and direct planimetry. Device selection did not follow a prespecified MVOA threshold. RESULTS: Seventy-two patients (81.0 years, IQR {74.3-85.0}) were included. In 32 patients, the P10 was implanted (44.4%). MR severity (p = 0.66), MR reduction (p = 0.73), and body surface area (p = 0.56) were comparable. Baseline MVOA tended to be smaller in P10 patients with the larger spacer (5.0 ± 1.1 vs. 5.4 ± 1.3cm2, p = 0.18), however, residual MVOA was larger in these patients (2.7 ± 0.7 vs. 2.3 ± 0.6cm2, p = 0.03). Accordingly, relative MVOA reduction was significantly less in P10 patients (- 45.9 ± 7.6 vs. - 56.3 ± 7.0%, p < 0.01). Indirect annuloplasty was more pronounced in Ace patients whereas mean transmitral gradients were similar. CONCLUSION: In FMR patients with non-complex anatomy, the larger spacer of the P10 maintains greater MVOA with similar MR reduction. Hence, the use of the PASCAL Ace device in patients with small MVOAs might correlate with a risk of both clinically relevant orifice reduction and even iatrogenic stenosis.

4.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38099912

RESUMO

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Idoso , Fatores de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Estudos de Viabilidade , Medição de Risco , Desenho de Prótese , Ecocardiografia Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA