Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Clin Microbiol ; 58(11)2020 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-32817144

RESUMO

A total of 1,200 serum samples that were tested for SARS-CoV-2 IgG antibody using the Abbott Architect immunoassay targeting the nucleocapsid protein were run in 3 SARS-CoV-2 IgG immunoassays targeting spike proteins (DiaSorin Liaison, Ortho Vitros, and Euroimmun). Consensus-positive and consensus-negative interpretations were defined as qualitative agreement in at least 3 of the 4 assays. Agreement of the 4 individual assays with a consensus-negative interpretation (n = 610) ranged from 96.7% to 100%, and agreement with a consensus-positive interpretation (n = 584) ranged from 94.3% to 100%. Laboratory-developed inhibition assays were utilized to evaluate 49 consensus-negative samples that were positive in only one assay; true-positive reactivity was confirmed in only 2 of these 49 (4%) samples. These findings demonstrate very high levels of agreement among 4 SARS-CoV-2 IgG assays authorized for emergency use, regardless of antigen target or assay format. Although false-positive reactivity was identified, its occurrence was rare (no more than 1.7% of samples for a given assay).


Assuntos
Infecções por Coronavirus , Nucleocapsídeo , Pandemias , Pneumonia Viral , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave , Anticorpos Antivirais , Betacoronavirus , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Humanos , Imunoensaio , Imunoglobulina G , SARS-CoV-2 , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus
2.
Transpl Infect Dis ; 19(1)2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27925350

RESUMO

We present a case of JC polyomavirus (JCV)-associated nephropathy (PyVAN) in an asymptomatic deceased-donor kidney transplant recipient. Despite the presence of viral cytopathic effect in the kidney biopsy and positive BK polyomavirus (BKV) in situ hybridization (ISH), BKV real-time polymerase chain reaction (PCR) results of plasma and urine were negative. JCV ISH was performed and was found to be positive. JCV real-time PCR on urine, plasma, and the kidney biopsy tissue was positive. Reduction in immunosuppression resulted in resolution of JCV viremia. This case highlights that JC-PyVAN is a distinct clinical entity and is likely to have a better clinical outcome than BK-PyVAN. Concurrent infection with BKV and JCV may occur, but may be difficult to confirm due to the potential for cross-reactivity between BKV and JCV ISH stains.


Assuntos
DNA Viral/isolamento & purificação , Vírus JC/isolamento & purificação , Nefropatias/diagnóstico , Transplante de Rim/efeitos adversos , Infecções por Polyomavirus/diagnóstico , Infecções Tumorais por Vírus/diagnóstico , Viremia/virologia , Soro Antilinfocitário/administração & dosagem , Soro Antilinfocitário/efeitos adversos , Soro Antilinfocitário/uso terapêutico , Vírus BK/isolamento & purificação , Biópsia , Feminino , Humanos , Terapia de Imunossupressão/efeitos adversos , Imunossupressores/administração & dosagem , Imunossupressores/efeitos adversos , Imunossupressores/uso terapêutico , Hibridização In Situ , Rim/patologia , Nefropatias/patologia , Nefropatias/virologia , Falência Renal Crônica/cirurgia , Pessoa de Meia-Idade , Infecções por Polyomavirus/patologia , Infecções por Polyomavirus/virologia , Reação em Cadeia da Polimerase em Tempo Real , Transplantados , Infecções Tumorais por Vírus/patologia , Infecções Tumorais por Vírus/virologia
4.
Diagn Microbiol Infect Dis ; 100(1): 115303, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33503569

RESUMO

Published studies show that >99% of sera reactive in the reverse syphilis testing algorithm (RSTA) screening assay with an index above an assay-specific threshold confirm as reactive, with either a rapid plasma reagin-reactive (RPRR) or RPR-nonreactive/Treponema pallidum particle agglutination-reactive (TPPAR) result. However, the relationship between screen indices and confirmatory patterns has not been characterized. We thus assessed confirmatory testing results for 577 sera submitted for RSTA testing and a screen-reactive result in the DiaSorin Liaison assay. The median screen index was significantly higher for RPRR samples than TPPAR samples (55.6 versus 10.4), and the proportion with indices >28.3 (median for all 577 samples) was significantly higher for RPRR versus TPPAR samples (82% versus 26%). However, RPRR titers did not significantly correlate with screen indices (R2 = 0.02). These findings demonstrate a significant relationship between RSTA screen indices and confirmatory assay results. The clinical utility of this relationship requires further study.


Assuntos
Algoritmos , Sorodiagnóstico da Sífilis , Sífilis/diagnóstico , Treponema pallidum/imunologia , Adulto , Anticorpos Antibacterianos/sangue , Feminino , Humanos , Imunoensaio , Modelos Lineares , Masculino , Sífilis/imunologia , Sífilis/microbiologia , Sorodiagnóstico da Sífilis/métodos , Sorodiagnóstico da Sífilis/normas
5.
Diagn Microbiol Infect Dis ; 95(3): 114864, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31395403

RESUMO

CDC guidelines recommend confirmatory testing of sera with low-positive indices (1.10-3.50) in the HerpeSelect® (HSLT) HSV-2 IgG screening assay. To determine if this recommendation is adequate for our patient population, we reviewed HSLT HSV-2 IgG screening indices for 262 screen-positive sera (index >1.10) tested in our confirmatory assay, which assesses inhibition of binding to recombinant gG2 by HSV-1- and HSV-2-infected cell lysates. To determine how the recommendation affects other screening assays, we tested these samples in the Liaison® HSV-2 IgG assay. Of 124 false-positive sera, 20% and 39% had an index >3.50 in the HSLT and Liaison screening assays, respectively. In both assays, 51% of 63 indeterminate sera (inhibition by HSV-1 lysate) had indices >3.50. Similarly, ≥75% of 75 true-positive samples exhibited indices >3.50 in both assays. Thus, confirmatory testing only of sera with low-positive HSV-2 IgG indices misses some false-positive and indeterminate samples, leading to misdiagnosis of HSV-2 infection.


Assuntos
Herpes Genital/diagnóstico , Herpesvirus Humano 2/isolamento & purificação , Imunoensaio/normas , Testes Sorológicos/normas , Anticorpos Antivirais/sangue , Reações Falso-Positivas , Herpesvirus Humano 1/imunologia , Herpesvirus Humano 2/imunologia , Humanos , Imunoglobulina G/sangue , Proteínas do Envelope Viral/imunologia
6.
Diagn Microbiol Infect Dis ; 67(3): 234-8, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20542204

RESUMO

Pyrosequence identification of 117 isolates of acid-fast bacilli (AFB) was compared to both routine phenotypic methods and Sanger sequencing. Two (2) vendor-provided pyrosequencing primers specific for AFB were used for the study. Pyrosequence analysis correctly identified 114 (98%) of the tested 117 AFB isolates. Among the test Mycobacterium spp., 18 of 20 Mycobacterium spp. were identified correctly to the species level. All rapidly growing mycobacteria were correctly identified to species by pyrosequencing. Other slowly growing mycobacteria such as Mycobacterium tuberculosis, Mycobacterium kansasii, Mycobacterium avium-intracellulare, and others were easily identified by pyrosequencing. Only Mycobacterium simiae and Mycobacterium scrofulaceum were not identifiable by the pyrosequence method. Among the 25 Nocardia isolates, all were correctly identified to the genus level. Identification of AFB by pyrosequence analysis provides both a rapid and accurate method for this group of organisms.


Assuntos
Técnicas Bacteriológicas/métodos , Infecções por Mycobacterium/diagnóstico , Mycobacterium/isolamento & purificação , Nocardiose/diagnóstico , Nocardia/isolamento & purificação , Análise de Sequência de DNA/métodos , Humanos , Mycobacterium/classificação , Mycobacterium/genética , Infecções por Mycobacterium/microbiologia , Nocardia/classificação , Nocardia/genética , Nocardiose/microbiologia , Sensibilidade e Especificidade
7.
AIDS ; 23(12): 1602-5, 2009 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-19474648

RESUMO

We investigated the phenotypic impact of a number of uncommon amino acid substitutions at HIV-1 reverse transcriptase positions 103 and 138, which are not part of the etravirine resistance score and were found in combination with the high-impact mutation K101P. Etravirine phenotypic fold changes were 380-1400 for K101P + E138A/G/Q + K103N/S/T + V179I and 12-130 for K101P + (K103S +/- V179I) in the absence of E138A/G/Q. Although the effect of K103S is unclear, additional position 138 substitutions seem important for etravirine susceptibility.


Assuntos
Fármacos Anti-HIV/farmacologia , HIV-1/genética , Mutação , Piridazinas/farmacologia , Farmacorresistência Viral/genética , Genótipo , Transcriptase Reversa do HIV/antagonistas & inibidores , Transcriptase Reversa do HIV/genética , HIV-1/efeitos dos fármacos , Humanos , Nitrilas , Fenótipo , Pirimidinas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA