Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artif Organs ; 47(8): 1386-1394, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37039965

RESUMO

BACKGROUND: Post-acute myocardial infarction papillary muscle rupture (post-AMI PMR) may present variable clinical scenarios and degree of emergency due to result of cardiogenic shock. Veno-arterial extracorporeal life support (V-A ECLS) has been proposed to improve extremely poor pre- or postoperative conditions. Information in this respect is scarce. METHODS: From the CAUTION (meChanical complicAtion of acUte myocardial infarcTion: an InternatiOnal multiceNter cohort study) database (16 different Centers, data from 2001 to 2018), we extracted adult patients who were surgically treated for post-AMI PMR and underwent pre- or/and postoperative V-A ECLS support. The end-points of this study were in-hospital survival and ECLS complications. RESULTS: From a total of 214 post-AMI PMR patients submitted to surgery, V-A ECLS was instituted in 23 (11%) patients. The median age was 61.7 years (range 46-81 years). Preoperatively, ECLS was commenced in 10 patients (43.5%), whereas intra/postoperative in the remaining 13. The most common V-A ECLS indication was post-cardiotomy shock, followed by preoperative cardiogenic shock and cardiac arrest. The median duration of V-A ECLS was 4 days. V-A ECLS complications occurred in more than half of the patients. Overall, in-hospital mortality was 39.2% (9/23), compared to 22% (42/219) for the non-ECLS group. CONCLUSIONS: In post-AMI PMR patients, V-A ECLS was used in almost 10% of the patients either to promote bridge to surgery or as postoperative support. Further investigations are required to better evaluate a potential for increased use and its effects of V-A ECLS in such a context based on the still high perioperative mortality.


Assuntos
Cardiomiopatias , Oxigenação por Membrana Extracorpórea , Doenças das Valvas Cardíacas , Infarto do Miocárdio , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Oxigenação por Membrana Extracorpórea/métodos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Estudos de Coortes , Músculos Papilares/cirurgia , Infarto do Miocárdio/complicações , Cardiomiopatias/complicações , Doenças das Valvas Cardíacas/complicações
2.
J Card Surg ; 37(7): 1959-1966, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35385588

RESUMO

BACKGROUND: Aim of this study is to analyse the performances of Clinical Risk Score (CRS) and European System for Cardiac Operative Risk Evaluation (EuroSCORE)-II in isolated tricuspid surgery. METHODS: Three hundred and eighty-three patients (54 ± 16 year; 54% female) were enrolled. Receiver operating characteristic analysis was performed to evaluate the relationship between the true positive fraction of test results and the false-positive fraction for a procedure. RESULTS: Considering the 30-day mortality the area under the curve was 0.6 (95% confidence interval [CI] 0.50-0.72) for EuroSCORE II and 0.7 (95% CI 0.56-0.84) for CRS-score. The ratio of expected/observed mortality showed underestimation when considering EuroSCORE-II (min. 0.46-max. 0.6). At multivariate analysis, the CRS score (p = .005) was predictor of late cardiac death. CONCLUSION: We suggest using both scores to obtain a range of expected mortality. CRS to speculate on late survival.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Tricúspide , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Valva Tricúspide/cirurgia
3.
J Card Surg ; 35(7): 1548-1555, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32490568

RESUMO

BACKGROUND: The aim of this multicenter prospective study was to evaluate the prognostic weight of preoperative right ventricular assessment on early mortality in cardiac surgery. METHODS: This is a multicenter prospective observational study performed by the Italian Group of Research for Outcome in Cardiac Surgery (GIROC) including 11 centers. From October 2017 to March 2019, out of 923 patients undergoing cardiac surgery, 28 patients with some missing data were excluded and 895 patients were enrolled in the study right ventricular dilatation was defined as a basal end-diastolic diameter >42 mm. The right ventricle (RV) function was assessed using the combination of three parameters: fractional area changing (FAC), tricuspid annular plane systolic excursion (TAPSE), and S'-wave using tissue Doppler imaging (TDI-S'); RV dysfunction was defined as the presence of at least two of the following cutoffs: FAC <35%, TAPSE <17 mm, and TDI S' <9.5 mm RESULTS: Among the entire cohort, 624 (70%) showed normal RV, 92 (10%) isolated RV dilatation, 154 (17%) isolated RV dysfunction, and 25 (3%) both RV dilatation and dysfunction. Non-surviving patients showed a significantly higher rate of RV alteration at multivariable analysis, RV status was found to be an independent predictor for higher in-hospital mortality beside Euroscore II. CONCLUSIONS: This prospective multicenter observation study shows the importance to assess RV preoperatively and to include both RV function and dimension in a risk score model such as Euroscore II to implement its predictivity, since PH cannot always mirror the status of the right ventricle.


Assuntos
Procedimentos Cirúrgicos Cardíacos/mortalidade , Ventrículos do Coração/patologia , Avaliação de Resultados em Cuidados de Saúde/métodos , Projetos de Pesquisa , Função Ventricular Direita , Adulto , Idoso , Idoso de 80 Anos ou mais , Dilatação Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Prognóstico , Estudos Prospectivos , Risco , Disfunção Ventricular Direita , Adulto Jovem
4.
J Card Surg ; 34(6): 514-517, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30981216

RESUMO

Infective endocarditis following a Mitraclip procedure might be an under-recognized complication. We describe the case of infective endocarditis by Bartonella henselae as a late complication in a patient with a previously implanted MitraClip system for mitral valve repair. Due to the severity of infection, surgical treatment was performed despite the high preoperative surgical risk, but recurrence of endocarditis of the biological valve implanted occurred. Although infection with Bartonella is known as a possible source of endocarditis, it has never been described before in relation to failed MitraClip therapy.


Assuntos
Cateterismo Cardíaco/métodos , Doença da Arranhadura de Gato/cirurgia , Endocardite Bacteriana/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/cirurgia , Idoso , Feminino , Próteses Valvulares Cardíacas/microbiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Recidiva , Índice de Gravidade de Doença , Falha de Tratamento
5.
Sci Rep ; 14(1): 8304, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594376

RESUMO

Impaired cardiac function has been described as a frequent complication of COVID-19-related pneumonia. To investigate possible underlying mechanisms, we represented the cardiovascular system by means of a lumped-parameter 0D mathematical model. The model was calibrated using clinical data, recorded in 58 patients hospitalized for COVID-19-related pneumonia, to make it patient-specific and to compute model outputs of clinical interest related to the cardiocirculatory system. We assessed, for each patient with a successful calibration, the statistical reliability of model outputs estimating the uncertainty intervals. Then, we performed a statistical analysis to compare healthy ranges and mean values (over patients) of reliable model outputs to determine which were significantly altered in COVID-19-related pneumonia. Our results showed significant increases in right ventricular systolic pressure, diastolic and mean pulmonary arterial pressure, and capillary wedge pressure. Instead, physical quantities related to the systemic circulation were not significantly altered. Remarkably, statistical analyses made on raw clinical data, without the support of a mathematical model, were unable to detect the effects of COVID-19-related pneumonia in pulmonary circulation, thus suggesting that the use of a calibrated 0D mathematical model to describe the cardiocirculatory system is an effective tool to investigate the impairments of the cardiocirculatory system associated with COVID-19.


Assuntos
COVID-19 , Sistema Cardiovascular , Humanos , Reprodutibilidade dos Testes , Circulação Pulmonar , Modelos Teóricos
6.
Transl Pediatr ; 13(1): 146-163, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38323181

RESUMO

Background and Objective: Computational models of the cardiovascular system allow for a detailed and quantitative investigation of both physiological and pathological conditions, thanks to their ability to combine clinical-possibly patient-specific-data with physical knowledge of the processes underlying the heart function. These models have been increasingly employed in clinical practice to understand pathological mechanisms and their progression, design medical devices, support clinicians in improving therapies. Hinging upon a long-year experience in cardiovascular modeling, we have recently constructed a computational multi-physics and multi-scale integrated model of the heart for the investigation of its physiological function, the analysis of pathological conditions, and to support clinicians in both diagnosis and treatment planning. This narrative review aims to systematically discuss the role that such model had in addressing specific clinical questions, and how further impact of computational models on clinical practice are envisaged. Methods: We developed computational models of the physical processes encompassed by the heart function (electrophysiology, electrical activation, force generation, mechanics, blood flow dynamics, valve dynamics, myocardial perfusion) and of their inherently strong coupling. To solve the equations of such models, we devised advanced numerical methods, implemented in a flexible and highly efficient software library. We also developed computational procedures for clinical data post-processing-like the reconstruction of the heart geometry and motion from diagnostic images-and for their integration into computational models. Key Content and Findings: Our integrated computational model of the heart function provides non-invasive measures of indicators characterizing the heart function and dysfunctions, and sheds light on its underlying processes and their coupling. Moreover, thanks to the close collaboration with several clinical partners, we addressed specific clinical questions on pathological conditions, such as arrhythmias, ventricular dyssynchrony, hypertrophic cardiomyopathy, degeneration of prosthetic valves, and the way coronavirus disease 2019 (COVID-19) infection may affect the cardiac function. In multiple cases, we were also able to provide quantitative indications for treatment. Conclusions: Computational models provide a quantitative and detailed tool to support clinicians in patient care, which can enhance the assessment of cardiac diseases, the prediction of the development of pathological conditions, and the planning of treatments and follow-up tests.

7.
J Clin Med ; 13(6)2024 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-38541805

RESUMO

Background: An unexplained condition that follows transcatheter aortic valve implantation (TAVI) is platelet count reduction (PR). According to published research, patients with balloon-expandable valves (BEVs) had a greater PR than those with self-expandable valves (SEVs). Objectives: The purpose of this study was to investigate the incidence and clinical effects of PR following TAVI. Methods: In total, 1.122 adult TAVI patients were enrolled. Propensity score matching was carried out in a 1:1 ratio between patients with BEVs and those with SEVs. The analysis included changes in platelet count, in-hospital mortality, and early postoperative adverse events. Results: Notably, 632 patients were matched (BEV:316; SEV:316). All patients' post-procedural platelet counts changed according to a parabolic curve, using a mixed regression model for repeated analyses (estimate = -0.931; standard error = 0.421; p = 0.027). The platelet count varied comparably in patients with BEVs and SEVs (estimate = -4.276, standard error = 4.760, p = 0.369). The average time for obtaining the nadir platelet count value was three days after implantation (BEV: 146 (108-181) vs. SEV: 149 (120-186); p = 0.142). Overall, 14.6% of patients (92/632) had post-procedural platelet count <100,000/µL. There was no difference between the two prosthesis types (BEV:51/316; SEV:41/316; p = 0.266). Thrombocytopenia was found to be significantly linked to blood product transfusions, lengthier stays in the intensive care unit and hospital, and in-hospital mortality. Conclusions: TAVI, irrespective of the type of implanted valve, is linked to a significant but temporary PR. Thrombocytopenia increases the risk of serious complications and in-hospital death in TAVI patients. To explore and clarify the causes and associated effects, further prospective research is necessary.

8.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38212996

RESUMO

OBJECTIVES: In the last decades, 4 different scores for the prediction of mortality following surgery for type A acute aortic dissection (TAAD) were proposed. We aimed to validate these scores in a large external multicentre cohort. METHODS: We retrospectively analysed patients who underwent surgery for TAAD between 2000 and 2020. Patients were enrolled from 10 centres from 2 European countries. Outcomes were the early (30-day and/or in-hospital) and 1-year mortality. Discrimination, calibration and observed/expected (O/E) ratio were evaluated. RESULTS: A total of 1895 patients (31.7% females, mean age 63.72 ± 12.8 years) were included in the study. Thirty-day mortality and in-hospital mortality were 21.7% (n = 412) and 22.5% (n = 427) respectively. The German Registry of Acute Aortic Dissection Type A (GERAADA) score shows to have the best discrimination [area under the curve (AUC) 0.671 and 0.672] in predicting as well the early and the 1-year mortality, followed by the International Registry of Acute Aortic Dissection (IRAD) model 1 (AUC 0.658 and 0.672), the Centofanti (AUC 0.645 and 0.66) and the UK aortic score (AUC 0.549 and 0.563). According to Hosmer-Lemeshow and Brier tests, the IRAD model I and GERAADA, respectively, were well calibrated for the early mortality, while the GERAADA and Centofanti for the 1-year mortality. The O/E analysis showed a marked underestimation for patients labelled as low-risk for UK aortic score and IRAD model I for both outcomes. CONCLUSIONS: The GERAADA score showed the best performance in comparison with other scores. However, none of them achieved together a fair discrimination and a good calibration for predicting either the early or the 1-year mortality.


Assuntos
Dissecção Aórtica , Azidas , Desoxiglucose/análogos & derivados , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estudos Retrospectivos , Dissecção Aórtica/cirurgia , Mortalidade Hospitalar , Europa (Continente) , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
9.
Artigo em Inglês | MEDLINE | ID: mdl-38327179

RESUMO

BACKGROUND AND AIMS: Mechanical complications (MCs) are rare but potentially fatal sequelae of acute myocardial infarction (AMI). Surgery, though challenging, is considered the treatment of choice. The authors sought to study early and long-term results of patients undergoing surgical treatment for post-AMI MCs. METHODS: Patients undergone surgical treatment for post-infarction MCs between 2001 through 2019 in 27 centers worldwide were retrieved from the database of CAUTION study. In-hospital and long-term mortality were the primary outcomes. Cox proportional hazards regression models were used to determine independent factors associated with overall mortality. RESULTS: The study included 720 patients. The median age was 70.0 [62.0-77.0] years, with a male predominance (64.6%). The most common MC encountered was ventricular septal rupture (VSR) (59.4%). Cardiogenic shock was seen on presentation in 56.1% of patients. In-hospital mortality rate was 37.4%; in more than 50% of cases, the cause of death was low cardiac output syndrome (LCOS). Late mortality occurred in 133 patients, with a median follow-up of 4.4 [1.0-8.6] years. Overall survival at 1, 5 and 10 years was 54.0%, 48.1% and 41.0%, respectively. Older age (p < 0.001) and postoperative LCOS (p < 0.001) were independent predictors of overall mortality. For hospital survivors, 10-year survival was 65.7% and was significant higher for patients with VSR than those with papillary muscle rupture (long-rank P = 0.022). CONCLUSIONS: Contemporary data from a multicenter cohort study show that surgical treatment for post-AMI MCs continues to be associated with high in-hospital mortality rates. However, long-term survival in patients surviving the immediate postoperative period is encouraging.Trial registration number: NCT03848429.

10.
Circulation ; 125(4): 604-14, 2012 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-22203696

RESUMO

BACKGROUND: The present study was aimed at determining the impact of type 2 diabetes mellitus (DM) on postoperative bioprosthetic structural valve degeneration. METHODS AND RESULTS: Twelve Italian centers participated in the study. Patient data refer to bioprosthetic implantations performed from November 1988 to December 2009, which resulted in 6184 patients (mean age 71.3±5.4 years, 60.1% male) being enrolled. Of these patients, 1731 (27.9%) had type 2 DM. The propensity score-matching algorithm successfully matched 1113 patients with type 2 DM with the same number of no-DM patients. The postmatching standard differences were less than 0.1 for each of the covariates, and 64.2% of DM patients were matched. The early (30 days) mortality rate was 7.8% (n=87) versus 2.9% (n=33) in patients with or without type 2 DM (P<0.001), respectively. Seven-year freedom from valve deterioration was significantly lower in patients with DM (73.2% [95% confidence interval, 61.6-85.5] versus 95.4% [95% confidence interval, 83.9-100], P<0.001). In Cox regression models with robust SEs that accounted for the clustering of matched pairs, DM was the strongest predictor of structural valve degeneration (hazard ratio 2.39 [95% confidence interval 2.28-3.52]). When we allowed for interaction between type 2 DM and other key risk factors, DM remained a significant predictor beyond any potentially associated variable. CONCLUSIONS: Patients with type 2 DM undergoing bioprosthetic valve implantation are at high risk of early and long-term mortality, as well as of structural valve degeneration.


Assuntos
Bioprótese/estatística & dados numéricos , Diabetes Mellitus Tipo 2/mortalidade , Doenças das Valvas Cardíacas/mortalidade , Próteses Valvulares Cardíacas/estatística & dados numéricos , Complicações Pós-Operatórias/mortalidade , Falha de Prótese/efeitos adversos , Idoso , Feminino , Seguimentos , Hemoglobinas Glicadas/metabolismo , Doenças das Valvas Cardíacas/cirurgia , Humanos , Hiperglicemia/mortalidade , Incidência , Unidades de Terapia Intensiva/estatística & dados numéricos , Itália/epidemiologia , Masculino , Análise Multivariada , Valor Preditivo dos Testes , Fatores de Risco
11.
J Clin Med ; 12(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38068466

RESUMO

Background: Platelet count reduction (PR) is a common but unclear phenomenon that occurs after aortic bioprosthesis valve implantation (bio-AVR). This study aimed to investigate the occurrence and clinical impact of PR in patients receiving stented, rapid deployment (RDV), or stentless bioprostheses. Methods: 1233 adult bio-AVR patients were enrolled. Platelet count variation, early post-operative adverse events, and in-hospital mortality were analysed. Results: 944 patients received a stented valve, an RDV was implanted in 218 patients, and 71 patients had a stentless bioprosthesis. In all groups, the platelet count at discharge was lower than the baseline values (p < 0.001). The percentage of PR was 27% in the stented group, 56% in the RDV group, and 55% in the stentless group. A higher platelet reduction, reaching the minimum platelet value, was observed in the RDV (mean: -30.84, standard error (SE): 5.91, p < 0.001) and stentless (mean: 22.54, SE: 9.10, p = 0.03) groups compared to the stented group. A greater PR occurred as the size of the bioprosthesis increased in RDV (p = 0.01), while platelet count variation was not directly proportional to the stented bioprosthesis size (p < 0.001). PR was not affected by cardiopulmonary bypass (mean: -0.00, SE: 0.001, p = 0.635) or cross-clamp (mean: -0.00, SE: 0.002, p = 0.051) times in any of the groups. RDV subjects experienced more in-hospital adverse events. PR was found to be associated with ischemic strokes in the overall population. Conclusions: Bio-AVR is associated with significant but transient PR. RDV patients more likely experience significant PR and related adverse clinical events. PR is associated with ischemic strokes, regardless of the bioprosthesis type.

12.
Am J Cardiol ; 189: 86-92, 2023 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-36516701

RESUMO

The intra-aortic balloon pump (IABP) is the most widely available mechanical support device, but its use has been disputed in recent decades. Although several efforts have been made to reduce the associated complication rate, contemporary data on this matter is lacking. The present study aims to evaluate the differences in vascular complications between the sheathless and the sheathed IABP implantation technique in cardiac surgery patients. A retrospective multi-center cohort, consisting of patients treated in 8 cardiac surgical centers, was evaluated. Patients who underwent cardiac surgery with peri-operative IABP support were included. Primary outcome was a composite end point of vascular complications. Propensity score matching (PSM) was performed, and a multivariable regression model was applied to evaluate predictors of vascular complications. The unmatched cohort consisted of 2,615 patients (sheathless n = 1,414, 54%, sheathed n = 1,201, 46%). A total of 878 patients were matched (n = 439 for both groups). The composite vascular complication end point occurred in 3% of patients in the sheathless group, compared with 8% in the sheathed group (p <0.001). Vascular complications were significantly associated with mortality (odds ratio [OR] 3.86, 95% confidence interval [CI] 2.01 to 7.40, p <0.001). Peripheral arterial disease was associated with vascular complications (OR 3.10, 95% CI 1.46 to 6.55, p = 0.003), whereas the sheathless implantation technique was found to be protective (OR 0.36, 95% CI 0.18 to 0.73, p = 0.005). In conclusion, the present retrospective multi-center analysis demonstrated the sheathless implantation technique to be associated with a significant reduction in vascular complication rate. Future studies should focus on even less invasive implantation techniques using smaller-sized catheters, sheathless implantation, and imaging guiding.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Doença Arterial Periférica , Humanos , Fatores de Risco , Balão Intra-Aórtico , Estudos Retrospectivos , Doença Arterial Periférica/etiologia , Resultado do Tratamento
13.
Int J Cardiol ; 371: 116-120, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36108764

RESUMO

OBJECTIVES: The role of the underlying etiology in isolated tricuspid valve surgery has not been investigated extensively in current literature. Aim of this study was to analyse outcomes of patients undergoing surgery due to endocarditis compared to other pathologies. METHODS: The SURTRI study is a multicenter study enrolling adult patients who underwent isolated tricuspid valve surgery (n = 406, 55 ± 16 y.o.; 56% female) at 13 international sites. Propensity weighted analysis was performed to compare groups (IE group n = 107 vs Not-IE group n = 299). RESULTS: No difference was found regarding the 30-day mortality (Group IE: 2.8% vs Group Not-IE = 6.8%; OR = 0.45) and major adverse events. Weighted cumulative incidence of cardiac death was significantly higher for patients with endocarditis (p = 0.01). The composite endpoint of cardiac death and reoperation at 6 years was reduced in the Group IE (63.2 ± 6.8% vs 78.9 ± 3.1%; p = 0.022). Repair strategy resulted in an increased late survival even in IE cases. CONCLUSIONS: Data from SURTRI study report acceptable 30-day results but significantly reduced late survival in the setting of endocarditis of the tricuspid valve. Multi-disciplinary approach, repair strategy and earlier treatment may improve outcomes.


Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Adulto , Humanos , Feminino , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Prognóstico , Resultado do Tratamento , Endocardite/diagnóstico , Endocardite/cirurgia , Endocardite/etiologia , Reoperação , Morte , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos
14.
Artigo em Inglês | MEDLINE | ID: mdl-38109676

RESUMO

OBJECTIVES: Post-acute myocardial infarction mechanical complications (post-AMI MCs) represent rare but life-threatening conditions, including free-wall rupture, ventricular septal rupture and papillary muscle rupture. During the coronavirus disease-19 (COVID-19) pandemic, an overwhelming pressure on healthcare systems led to delayed and potentially suboptimal treatments for time-dependent conditions. As AMI-related hospitalizations decreased, limited information is available whether higher rates of post-AMI MCs and related deaths occurred in this setting. This study was aimed to assess how COVID-19 in Europe has impacted the incidence, treatment and outcome of MCs. METHODS: The CAUTION-COVID19 study is a multicentre retrospective study collecting 175 patients with post-AMI MCs in 18 centres from 6 European countries, aimed to compare the incidence of such events, related patients' characteristics, and outcomes, between the first year of pandemic and the 2 previous years. RESULTS: A non-significant increase in MCs was observed [odds ratio (OR) = 1.15, 95% confidence interval (CI) 0.85-1.57; P = 0.364], with stronger growth in ventricular septal rupture diagnoses (OR = 1.43, 95% CI 0.95-2.18; P = 0.090). No significant differences in treatment types and mortality were found between the 2 periods. In-hospital mortality was 50.9% and was higher for conservatively managed cases (90.9%) and lower for surgical patients (44.0%). Patients admitted during COVID-19 more frequently had late-presenting infarction (OR = 2.47, 95% CI 1.24-4.92; P = 0.010), more stable conditions (OR = 2.61, 95% CI 1.27-5.35; P = 0.009) and higher EuroSCORE II (OR = 1.04, 95% CI 1.01-1.06; P = 0.006). CONCLUSIONS: A non-significant increase in MCs incidence occurred during the first year of COVID-19, characterized by a significantly higher rate of late-presenting infarction, stable conditions and EuroSCORE-II if compared to pre-pandemic data, without affecting treatment and mortality.

15.
Eur Heart J Open ; 3(5): oead091, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37840585

RESUMO

Aims: Many historical and recent reports showed that post-infarction ventricular septal rupture (VSR) represents a life-threatening condition and the strategy to optimally manage it remains undefined. Therefore, disparate treatment policies among different centres with variable results are often described. We analysed data from European centres to capture the current clinical practice in VSR management. Methods and results: Thirty-nine centres belonging to eight European countries participated in a survey, filling a digital form of 38 questions from April to October 2022, to collect information about all the aspects of VSR treatment. Most centres encounter 1-5 VSR cases/year. Surgery remains the treatment of choice over percutaneous closure (71.8% vs. 28.2%). A delayed repair represents the preferred approach (87.2%). Haemodynamic conditions influence the management in almost all centres, although some try to achieve patients stabilization and delayed surgery even in cardiogenic shock. Although 33.3% of centres do not perform coronarography in unstable patients, revascularization approaches are widely variable. Most centres adopt mechanical circulatory support (MCS), mostly extracorporeal membrane oxygenation, especially pre-operatively to stabilize patients and achieve delayed repair. Post-operatively, such MCS are more often adopted in patients with ventricular dysfunction. Conclusion: In real-life, delayed surgery, regardless of the haemodynamic conditions, is the preferred strategy for VSR management in Europe. Extracorporeal membrane oxygenation is becoming the most frequently adopted MCS as bridge-to-operation. This survey provides a useful background to develop dedicated, prospective studies to strengthen the current evidence on VSR treatment and to help improving its currently unsatisfactory outcomes.

16.
J Clin Med ; 13(1)2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38202159

RESUMO

BACKGROUND: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years. METHODS: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test. RESULTS: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period (p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322-0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077-0.933, p = 0.039). CONCLUSIONS: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients.

17.
Med Eng Phys ; 107: 103849, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36068037

RESUMO

Left ventricular assist devices (LVADs) are used to provide haemodynamic support to patients with critical cardiac failure. Severe complications can occur because of the modifications of the blood flow in the aortic region. In this work, the effect of a continuous flow LVAD device on the aortic flow is investigated by means of a non-intrusive reduced order model (ROM) built using the proper orthogonal decomposition with interpolation (PODI) method based on radial basis functions (RBF). The full order model (FOM) is represented by the incompressible Navier-Stokes equations discretized by using a Finite Volume (FV) technique, coupled with three-element Windkessel models to enforce outlet boundary conditions in a multi-scale approach. A patient-specific framework is proposed: a personalized geometry reconstructed from Computed Tomography (CT) images is used and the individualization of the coefficients of the three-element Windkessel models is based on experimental data provided by the Right Heart Catheterization (RHC) and Echocardiography (ECHO) tests. At FOM level, we also consider the pre-surgery configuration in order to further validate the predictive capabilities of the model in several contexts. The ROM has been tested by considering a parametric setting with respect to the LVAD flow, which is a crucial parameter of the problem. We consider a parameter range that covers typical clinical values. The accuracy of the ROM is assessed against results obtained with the FOM both for primal, velocity and pressure, and derived quantities, wall shear stress (WSS). Finally, we briefly discuss the efficiency of our ROM approach.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Aorta/fisiologia , Ecocardiografia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Hemodinâmica , Humanos
18.
Artigo em Inglês | MEDLINE | ID: mdl-35381083

RESUMO

OBJECTIVES: Although the intra-aortic balloon pump (IABP) has been the most widely adopted temporary mechanical support device in cardiac surgical patients, its use has declined. The current study aimed to evaluate the occurrence and predictors of early mortality and complication rates in contemporary cardiac surgery patients supported by an IABP. METHODS: A multicentre, retrospective analysis was performed of all consecutive cardiac surgical patients receiving perioperative balloon pump support in 8 centres between January 2010 to December 2019. The primary outcome was early mortality, and secondary outcomes were balloon-associated complications. A multivariable binary logistic regression model was applied to evaluate predictors of the primary outcome. RESULTS: The study cohort consisted of 2615 consecutive patients. The median age was 68 years [25th percentile 61, 75th percentile 75 years], with the majority being male (76.9%), and a mean calculated 30-day mortality risk of 10.0%. Early mortality was 12.7% (n = 333), due to cardiac causes (n = 266), neurological causes (=22), balloon-related causes (n = 5) and other causes (n = 40). A composite end point of all vascular complications occurred in 7.2% of patients, and leg ischaemia was observed in 1.3% of patients. The most important predictors of early mortality were peripheral vascular disease [odds ratio (OR) 1.63], postoperative dialysis requirement (OR 10.40) and vascular complications (OR 2.57). CONCLUSIONS: The use of the perioperative IABP proved to be safe and demonstrated relatively low complication rates, particularly for leg ischaemia. As such, we believe that specialists should not be held back to use this widely available treatment in high-risk cardiac surgical patients when indicated.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Balão Intra-Aórtico , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Humanos , Balão Intra-Aórtico/efeitos adversos , Isquemia/etiologia , Masculino , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
19.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35448903

RESUMO

OBJECTIVES: The interest in isolated tricuspid valve disease has rapidly increased recently. However, clinical trials and registry data are rare in the surgical literature. This study aimed to describe the early and long-term outcomes of a real-world experience in isolated tricuspid procedures comparing repair and replacement strategies. METHODS: The Surgical-Tricuspid study is a multicentre retrospective study that enrolled adult patients who had undergone isolated tricuspid valve surgery at 13 international sites. Propensity score-matched analysis was used to compare repair versus replacement. RESULTS: A cohort of 426 patients was enrolled [mean age: 55 (16) years; 56% female]. After matching, 175 comparable pairs were analysed. Preoperative left ventricular ejection fraction was 55(9) vs 56(9) (P = 0.8) while moderate-severe tricuspid regurgitation was present in 95% of cases. The 30-day mortality rate was 4.0% vs 8.0% in the repair and replacement groups, respectively (P = 0.115). The rates of re-exploration for bleeding (6.9% vs 13.1% P = 0.050), permanent pacemaker implantation (5.1% vs 12.0%; P = 0.022) and blood transfusion (46% vs 62%; P = 0.002) were higher in the replacement group. Cumulative survival rates at 3, 5 and 7 years in the repair group were 84 (3)%, 75 (4)% and 56 (9)% vs 71 (4)%, 66 (5)% and 58 (5)% in the replacement group (P = 0.001) while cumulative incidence for reoperation at 10 years did not differ between groups [repair 10 (1)% vs replacement 9 (1)%; P = 0.469]. CONCLUSIONS: The data from the Surgical-Tricuspid study reported a high risk for patients undergoing tricuspid surgery. Isolated valve repair offered reduced early and late mortality with no difference regarding reoperation rate when compared with replacement.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Adulto , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/etiologia , Função Ventricular Esquerda
20.
Ann Thorac Surg ; 113(2): 585-592, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33831392

RESUMO

BACKGROUND: Isolated tricuspid valve (TV) surgery is a rare procedure generally considered at high risk for perioperative mortality and poor long-term outcomes. Surgical treatment can be performed with either an arrested heart (AH) or beating heart (BH) technique. The aim of this study was to compare the outcomes of isolated tricuspid surgery with 2 different approaches. METHODS: The Surgical-Tricuspid Study is a multicenter international retrospective study enrolling adult patients who underwent isolated TV procedures (n = 406; age 56 ± 16 years; 56% female) at 13 international sites. The AH and BH strategies were performed in 253 and 153 patients, respectively. Propensity score-matched analysis was used to compare groups. RESULTS: After matching, 129 pairs were obtained and analyzed. The 30-day mortality rate was 6.2% versus 5.0% in the AH and BH groups, respectively (P = .9). The rates of acute renal failure requiring replacement therapy (10% versus 3%; P = .02) and stroke (1.6% versus 0%; P = .08) were numerically higher in the AH group. The 6-year survival rate was 67% ± 6% versus 78% ± 5% in the AH and BH groups, respectively (P = .18), whereas freedom from cardiac death was 75% ± 5% versus 84% ± 4% (P = .21). The 6-year composite cardiac end point of cardiac death and reoperation rate was 60% ± 9% versus 86% ± 5% (P = .024) comparing AH-TV replacement and BH-TV repair groups. CONCLUSIONS: Isolated TV surgery performed with a BH strategy is a safe option and resulted in a trend of increased long-term survival and freedom from reoperation compared with the standard AH technique. Patients undergoing BH valve repair had the best long-term outcome.


Assuntos
Parada Cardíaca Induzida/métodos , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/epidemiologia , Pontuação de Propensão , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA