Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
AAPS PharmSciTech ; 18(7): 2808-2813, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28382602

RESUMO

Secondary drying is the final step of lyophilization before stoppering, during which water is desorbed from the product to yield the final moisture content. We studied how chamber pressure and partial pressure of water vapor during this step affected the time course of water content of aqueous solutions of polyvinylpyrrolidone (PVP) in glass vials. The total chamber pressure had no effect when the partial pressure of water vapor was very low. However, when the vapor phase contained a substantial fraction of water vapor, the PVP moisture content was much higher. We carried out dynamic vapor sorption experiments (DVS) to demonstrate that the higher PVP moisture content was a straightforward result of the higher water vapor content in the lyophilizer. The results highlight that the partial pressure of water vapor is extremely important during secondary drying in lyophilization, and that lower chamber pressure set points for secondary drying may sometimes be justified as a strategy for ensuring low partial pressure of water vapor, especially for lyophilizers that do not inject dry gas to control pressure. These findings have direct application for process transfers/scale ups from freeze-dryers that do not inject dry gas for pressure control to those that do, and vice versa.


Assuntos
Liofilização/métodos , Pressão Parcial , Pressão , Vapor
2.
J Pharm Sci ; 111(9): 2639-2644, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35613684

RESUMO

We compared "ice-fog" controlled ice nucleation at -6 °C to annealing at the same temperature for a 50 mg/mL monoclonal antibody formulation, using shelf-ramp freezing as a control. Cake structure, drying time, reconstitution time, specific surface area, calculated cake resistance and size exclusion chromatography were all compared. Controlled nucleation resulted in the fastest reconstitution, shortest primary drying, lowest calculated cake resistance, lowest specific surface area and highest moisture content. There was no effect upon the results for size exclusion chromatography. Results for annealing were between those for controlled nucleation and shelf-ramp freezing. All results were consistent with "ice-fog" controlled nucleation at -6 °C having greater impact upon the ice crystal morphology than annealing at the same temperature for 3 h.


Assuntos
Anticorpos Monoclonais , Gelo , Anticorpos Monoclonais/química , Liofilização/métodos , Congelamento , Gelo/análise , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA