Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Nanotechnology ; 30(37): 37LT03, 2019 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-31212258

RESUMO

One-dimensional metal nanowires offer great potential in printing transparent electrodes for next-generation optoelectronic devices such as flexible displays and flexible solar cells. Printing fine patterns of metal nanowires with widths <100 µm is critical for their practical use in the devices. However, the fine printing of metal nanowires onto polymer substrates remains a major challenge owing to their unintended alignment. This paper reports on a fine-printing method for transparent silver nanowires (AgNWs) electrodes miniaturized to a width of 50 µm on ultrathin (1 µm) polymer substrate, giving a high yield of >90%. In this method, the AgNW dispersion, which is swept by a glass rod, is spontaneously deposited to the hydrophilic areas patterned on a hydrophobic-coated substrate. The alignment and accumulation of AgNWs at the pattern periphery are enhanced by employing a high sweeping rate of >3.2 mm s-1, improving electrical conductivity and pattern definition. The more aligned and more accumulated AgNWs lower the sheet resistance by a factor of up to 6.8. In addition, a high pattern accuracy ≤ 3.6 µm, which is the deviation from the pattern designs, is achieved. Quantitative analyses are implemented on the nanowire alignment to understand the nanowire geometry. This fine-printing method of the AgNW electrodes will provide great opportunities for realizing flexible and high-performance optoelectronic devices.

2.
Nature ; 499(7459): 458-63, 2013 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-23887430

RESUMO

Electronic devices have advanced from their heavy, bulky origins to become smart, mobile appliances. Nevertheless, they remain rigid, which precludes their intimate integration into everyday life. Flexible, textile and stretchable electronics are emerging research areas and may yield mainstream technologies. Rollable and unbreakable backplanes with amorphous silicon field-effect transistors on steel substrates only 3 µm thick have been demonstrated. On polymer substrates, bending radii of 0.1 mm have been achieved in flexible electronic devices. Concurrently, the need for compliant electronics that can not only be flexed but also conform to three-dimensional shapes has emerged. Approaches include the transfer of ultrathin polyimide layers encapsulating silicon CMOS circuits onto pre-stretched elastomers, the use of conductive elastomers integrated with organic field-effect transistors (OFETs) on polyimide islands, and fabrication of OFETs and gold interconnects on elastic substrates to realize pressure, temperature and optical sensors. Here we present a platform that makes electronics both virtually unbreakable and imperceptible. Fabricated directly on ultrathin (1 µm) polymer foils, our electronic circuits are light (3 g m(-2)) and ultraflexible and conform to their ambient, dynamic environment. Organic transistors with an ultra-dense oxide gate dielectric a few nanometres thick formed at room temperature enable sophisticated large-area electronic foils with unprecedented mechanical and environmental stability: they withstand repeated bending to radii of 5 µm and less, can be crumpled like paper, accommodate stretching up to 230% on prestrained elastomers, and can be operated at high temperatures and in aqueous environments. Because manufacturing costs of organic electronics are potentially low, imperceptible electronic foils may be as common in the future as plastic wrap is today. Applications include matrix-addressed tactile sensor foils for health care and monitoring, thin-film heaters, temperature and infrared sensors, displays, and organic solar cells.


Assuntos
Eletrônica/instrumentação , Plásticos/química , Atenção à Saúde , Elastômeros/química , Desenho de Equipamento , Dedos , Temperatura Alta , Humanos , Raios Infravermelhos , Arcada Osseodentária/anatomia & histologia , Modelos Anatômicos , Maleabilidade , Transistores Eletrônicos
3.
Proc Natl Acad Sci U S A ; 112(47): 14533-8, 2015 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-26554008

RESUMO

We report a fabrication method for flexible and printable thermal sensors based on composites of semicrystalline acrylate polymers and graphite with a high sensitivity of 20 mK and a high-speed response time of less than 100 ms. These devices exhibit large resistance changes near body temperature under physiological conditions with high repeatability (1,800 times). Device performance is largely unaffected by bending to radii below 700 µm, which allows for conformal application to the surface of living tissue. The sensing temperature can be tuned between 25 °C and 50 °C, which covers all relevant physiological temperatures. Furthermore, we demonstrate flexible active-matrix thermal sensors which can resolve spatial temperature gradients over a large area. With this flexible ultrasensitive temperature sensor we succeeded in the in vivo measurement of cyclic temperatures changes of 0.1 °C in a rat lung during breathing, without interference from constant tissue motion. This result conclusively shows that the lung of a warm-blooded animal maintains surprising temperature stability despite the large difference between core temperature and inhaled air temperature.


Assuntos
Temperatura Corporal , Animais , Grafite/química , Polímeros/química , Ratos , Difração de Raios X
4.
Nat Mater ; 20(11): 1460-1461, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34697426
5.
Nanotechnology ; 28(1): 01LT01, 2017 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-27893449

RESUMO

A biaxially wave-shaped polydimethylsiloxane (PDMS) surface was developed simply by using a taro leaf as the template. The resulting leaf-templated PDMS (L-PDMS) possesses a micro-sized curved interface structure, which is greatly beneficial for the exact embedding of a silver nanowire (AgNW) network conductive film covering the L-PDMS surface. The intrinsically curved AgNW/L-PDMS film surface, without any dangling nanowire, could prevent the fracture of AgNWs due to stretching stress even after cyclic stretching. More importantly, it also exhibited a biaxial stretchability, which showed ultra-stable resistance after continuous stretching for 100 cycles each in X- and Y-directions. This biaxially stretchable AgNW/L-PDMS film could extend the application fields in stretchable electronics.

6.
Nanotechnology ; 27(45): 45LT02, 2016 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-27713190

RESUMO

Silver nanowires (AgNWs) are excellent candidate electrode materials in next-generation wearable devices due to their high flexibility and high conductivity. In particular, patterning techniques for AgNWs electrode manufacture are very important in the roll-to-roll printing process to achieve high throughput and special performance production. It is also essential to realize a non-contact mode patterning for devices in order to keep the pre-patterned components away from mechanical damages. Here, we report a successful non-contact patterning of AgNWs-based stretchable and transparent electrodes by laser-induced forward transfer (LIFT) technique. The technique was used to fabricate a 100% stretchable electrode with a width of 200 µm and electrical resistivity 10-4 Ωcm. Experiments conducted integrating the stretchable electrode on rubber substrate in which LED was pre-fabricated showed design flexibility resulting from non-contact printing. Further, a patterned transparent electrode showed over 80% in optical transmittance and less than 100 Ω sq-1 in sheet resistance by the optimized LIFT technique.

7.
J Prosthodont Res ; 68(1): 122-131, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37197948

RESUMO

PURPOSE: To evaluate the reproducibility and reliability of a novel electromyogram (EMG) device with a flexible sheet sensor for measuring muscle activity related to mastication and swallowing. METHODS: We developed a new EMG device made of elastic sheet electrodes to measure the masseter and digastric muscle activities for evaluating mastication and swallowing. To examine the measurement reproducibility of the new EMG device, masseter muscle activity was analyzed using the intraclass correlation coefficient (ICC). Further, we measured the maximum amplitude, duration, integrated value, and signal-to-noise ratio (SNR) using the new EMG device and conventional EMG devices and evaluated the reliability using ICC and Bland-Altman analysis. RESULTS: We confirmed high ICC (1,1) and ICC (2,1) scores (0.92 and 0.88, respectively) while measuring the reproducibility of the new EMG device. When compared to the active electrode EMG device, we found a high correlation for the maximum amplitude (0.90), duration (0.99), integrated values (0.90), and SNR (0.75), with no observation of significant fixed errors. Moreover, the regression coefficient was not significant for any of the evaluation items and no proportional error was observed. Compared with the passive electrode EMG device, the maximum amplitude and duration were highly correlated (0.73 and 0.89). In addition, the SNR exhibited a significant fixed error. In contrast, the regression coefficient was not significant for any of the evaluation items and no proportional error was observed. CONCLUSIONS: Our results suggest that the new EMG device can be used to reliably and reproducibly evaluate muscle activity during mastication and swallowing.


Assuntos
Músculo Masseter , Mastigação , Músculo Masseter/fisiologia , Eletromiografia/métodos , Reprodutibilidade dos Testes , Mastigação/fisiologia , Eletrodos
8.
Adv Mater ; 36(15): e2309864, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38213132

RESUMO

Flexible imagers are currently under intensive development as versatile optical sensor arrays, designed to capture images of surfaces and internals, irrespective of their shape. A significant challenge in developing flexible imagers is extending their detection capabilities to encompass a broad spectrum of infrared light, particularly terahertz (THz) light at room temperature. This advancement is crucial for thermal and biochemical applications. In this study, a flexible infrared imager is designed using uncooled carbon nanotube (CNT) sensors and organic circuits. The CNT sensors, fabricated on ultrathin 2.4 µm substrates, demonstrate enhanced sensitivity across a wide infrared range, spanning from near-infrared to THz wavelengths. Moreover, they retain their characteristics under bending and crumpling. The design incorporates light-shielded organic transistors and circuits, functioning reliably under light irradiation, and amplifies THz detection signals by a factor of 10. The integration of both CNT sensors and shielded organic transistors into an 8 × 8 active-sensor matrix within the imager enables sequential infrared imaging and nondestructive assessment for heat sources and in-liquid chemicals through wireless communication systems. The proposed imager, offering unique functionality, shows promise for applications in biochemical analysis and soft robotics.

9.
Science ; 380(6646): 690-691, 2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37200412

RESUMO

Artificial skin mimics the sensory feedback of biological skin.


Assuntos
Retroalimentação Sensorial , Pele Artificial , Pele , Humanos
10.
Adv Mater ; : e2304048, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37403808

RESUMO

The integration of flexible electronics with optics can help realize a powerful tool that facilitates the creation of a smart society wherein internal evaluations can be easily performed nondestructively from the surface of various objects that is used or encountered in daily lives. Here, organic-material-based stretchable optical sensors and imagers that possess both bending capability and rubber-like elasticity are reviewed. The latest trends in nondestructive evaluation equipment that enable simple on-site evaluations of health conditions and abnormalities are discussed without subjecting the targeted living bodies and various objects to mechanical stress. Real-time performance under real-life conditions is becoming increasingly important for creating smart societies interwoven with optical technologies. In particular, the terahertz (THz)-wave region offers a substance- and state-specific fingerprint spectrum that enables instantaneous analyses. However, to make THz sensors accessible, the following issues must be addressed: broadband and high-sensitivity at room temperature, stretchability to follow the surface movements of targets, and digital transformation compatibility. The materials, electronics packaging, and remote imaging systems used to overcome these issues are discussed in detail. Ultimately, stretchable optical sensors and imagers with highly sensitive and broadband THz sensors can facilitate the multifaceted on-site evaluation of solids, liquids, and gases.

11.
Adv Sci (Weinh) ; 10(2): e2204746, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36373679

RESUMO

Optical transparency is highly desirable in bioelectronic sensors because it enables multimodal optical assessment during electronic sensing. Ultrathin (<5 µm) organic electrochemical transistors (OECTs) can be potentially used as a highly efficient bioelectronic transducer because they demonstrate high transconductance during low-voltage operation and close conformability to biological tissues. However, the fabrication of fully transparent ultrathin OECTs remains a challenge owing to the harsh etching processes of nanomaterials. In this study, fully transparent, ultrathin, and flexible OECTs are developed using additive integration processes of selective-wetting deposition and thermally bonded lamination. These processes are compatible with Ag nanowire electrodes and conducting polymer channels and realize unprecedented flexible OECTs with high visible transmittance (>90%) and high transconductance (≈1 mS) in low-voltage operations (<0.6 V). Further, electroencephalogram acquisition and nitrate ion sensing are demonstrated in addition to the compatibility of simultaneous assessments of optical blood flowmetry when the transparent OECTs are worn, owing to the transparency. These feasibility demonstrations show promise in contributing to human stress monitoring in bioelectronics.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Humanos , Polímeros , Eletrodos
12.
Small ; 8(1): 73-9, 2012 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-22095923

RESUMO

Bottom-gate, top-contact organic thin-film transistors (TFTs) with excellent static characteristics (on/off ratio: 10(7) ; intrinsic mobility: 3 cm(2) (V s)(-1) ) and fast unipolar ring oscillators (signal delay as short as 230 ns per stage) are fabricated. The significant contribution of the transfer length to the relation between channel length, contact length, contact resistance, effective mobility, and cutoff frequency of the TFTs is theoretically and experimentally analyzed.

13.
ACS Appl Electron Mater ; 4(12): 6308-6321, 2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36588622

RESUMO

Flexible electronics has paved the way toward the development of next-generation wearable and implantable healthcare devices, including multimodal sensors. Integrating flexible circuits with transducers on a single substrate is desirable for processing vital signals. However, the trade-off between low power consumption and high operating speed is a major bottleneck. Organic thin-film transistors (OTFTs) are suitable for developing flexible circuits owing to their intrinsic flexibility and compatibility with the printing process. We used a photoreactive insulating polymer poly((±)endo,exo-bicyclo[2.2.1]hept-ene-2,3-dicarboxylic acid, diphenylester) (PNDPE) to modulate the power consumption and operating speed of ultraflexible organic circuits fabricated on a single substrate. The turn-on voltage (V on) of the p- and n-type OTFTs was controlled through a nanoscale interfacial photochemical reaction. The time-of-flight secondary ion mass spectrometry revealed the preferential occurrence of the PNDPE photochemical reaction in the vicinity of the semiconductor-dielectric interface. The power consumption and operating speed of the ultraflexible complementary inverters were tuned by a factor of 6 and 4, respectively. The minimum static power consumption was 30 ± 9 pW at transient and 4 ± 1 pW at standby. Furthermore, within the tuning range of the operating speed and at a supply voltage above 2.5 V, the minimum stage delay time was of the order of hundreds of microseconds. We demonstrated electromyogram measurements to emphasize the advantage of the nanoscale interfacial photochemical reaction. Our study suggests that a nanoscale interfacial photochemical reaction can be employed to develop imperceptible and wearable multimodal sensors with organic signal processing circuits that exhibit low power consumption.

14.
Sci Adv ; 8(19): eabm4349, 2022 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-35544563

RESUMO

Chemical monitoring communicates diverse environmental information from industrial and biological processes. However, promising and sustainable systems and associated inspection devices that dynamically enable on-site quality monitoring of target chemicals confined inside transformable and opaque channels are yet to be investigated. This paper designs stretchable photo-sensor patch sheets for nonsampling, source-free, and label-free on-site dynamic chemical monitoring of liquids flowing inside soft tubes via simple deformable surface wrapping. The device integrates carbon nanotube-based broadband photo-absorbent thin films with multilayer-laminated stretchable electrodes and substrates. The patterned rigid-soft structure of the proposed device provides durability and optical stability against mechanical deformations with a stretchability range of 70 to 280%, enabling shape-conformable attachments to transformable objects. The effective use of omnidirectional and transparent blackbody radiation from free-form targets themselves allows compact measurement configuration and enhances the functionality and simplicity of this scheme, while the presenting technology monitors concentrations of arbitrary water-soluble chemicals.

15.
Nat Mater ; 9(12): 1015-22, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21057499

RESUMO

Flexible electronic circuits are an essential prerequisite for the development of rollable displays, conformable sensors, biodegradable electronics and other applications with unconventional form factors. The smallest radius into which a circuit can be bent is typically several millimetres, limited by strain-induced damage to the active circuit elements. Bending-induced damage can be avoided by placing the circuit elements on rigid islands connected by stretchable wires, but the presence of rigid areas within the substrate plane limits the bending radius. Here we demonstrate organic transistors and complementary circuits that continue to operate without degradation while being folded into a radius of 100 µm. This enormous flexibility and bending stability is enabled by a very thin plastic substrate (12.5 µm), an atomically smooth planarization coating and a hybrid encapsulation stack that places the transistors in the neutral strain position. We demonstrate a potential application as a catheter with a sheet of transistors and sensors wrapped around it that enables the spatially resolved measurement of physical or chemical properties inside long, narrow tubes.

16.
Proc Natl Acad Sci U S A ; 105(13): 4976-80, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18362348

RESUMO

A major obstacle to the development of organic transistors for large-area sensor, display, and circuit applications is the fundamental compromise between manufacturing efficiency, transistor performance, and power consumption. In the past, improving the manufacturing efficiency through the use of printing techniques has inevitably resulted in significantly lower performance and increased power consumption, while attempts to improve performance or reduce power have led to higher process temperatures and increased manufacturing cost. Here, we lift this fundamental limitation by demonstrating subfemtoliter inkjet printing to define metal contacts with single-micrometer resolution on the surface of high-mobility organic semiconductors to create high-performance p-channel and n-channel transistors and low-power complementary circuits. The transistors employ an ultrathin low-temperature gate dielectric based on a self-assembled monolayer that allows transistors and circuits on rigid and flexible substrates to operate with very low voltages.

17.
Nat Commun ; 12(1): 2399, 2021 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-33893292

RESUMO

Energy autonomy and conformability are essential elements in the next generation of wearable and flexible electronics for healthcare, robotics and cyber-physical systems. This study presents ferroelectric polymer transducers and organic diodes for imperceptible sensing and energy harvesting systems, which are integrated on ultrathin (1-µm) substrates, thus imparting them with excellent flexibility. Simulations show that the sensitivity of ultraflexible ferroelectric polymer transducers is strongly enhanced by using an ultrathin substrate, which allows the mounting on 3D-shaped objects and the stacking in multiple layers. Indeed, ultraflexible ferroelectric polymer transducers have improved sensitivity to strain and pressure, fast response and excellent mechanical stability, thus forming imperceptible wireless e-health patches for precise pulse and blood pressure monitoring. For harvesting biomechanical energy, the transducers are combined with rectifiers based on ultraflexible organic diodes thus comprising an imperceptible, 2.5-µm thin, energy harvesting device with an excellent peak power density of 3 mW·cm-3.


Assuntos
Fontes de Energia Bioelétrica , Técnicas Biossensoriais/instrumentação , Eletrônica Médica/instrumentação , Transdutores , Dispositivos Eletrônicos Vestíveis , Técnicas Biossensoriais/métodos , Eletrônica Médica/métodos , Humanos , Sistemas Microeletromecânicos/instrumentação , Sistemas Microeletromecânicos/métodos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes , Robótica/instrumentação , Robótica/métodos
18.
Adv Mater ; 33(45): e2104446, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34545628

RESUMO

Flexible electronics have gained considerable attention for application in wearable devices. Organic transistors are potential candidates to develop flexible integrated circuits (ICs). A primary technique for maximizing their reliability, gain, and operation speed is the modulation of charge-carrier behavior in the respective transistors fabricated on the same substrate. In this work, heterogeneous functional dielectric patterns (HFDP) of ultrathin polymer gate dielectrics of poly((±)endo,exo-bicyclo[2.2.1]hept-ene-2,3-dicarboxylic acid, diphenylester) (PNDPE) are introduced. The HFDP that are obtained via the photo-Fries rearrangement by ultraviolet radiation in the homogeneous PNDPE provide a functional area for charge-carrier modulation. This leads to programmable threshold voltage control over a wide range (-1.5 to +0.2 V) in the transistors with a high patterning resolution, at 2 V operational voltage. The transistors also exhibit high operational stability over 140 days and under the bias-stress duration of 1800 s. With the HFDP, the performance metrics of ICs, for example, the noise margin and gain of the zero-VGS load inverters and the oscillation frequency of ring oscillators are improved to 80%, 1200, and 2.5 kHz, respectively, which are the highest among the previously reported zero-VGS -based organic circuits. The HFDP can be applied to much complex and ultraflexible ICs.

19.
Nat Mater ; 8(6): 494-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19430465

RESUMO

Stretchability will significantly expand the applications scope of electronics, particularly for large-area electronic displays, sensors and actuators. Unlike for conventional devices, stretchable electronics can cover arbitrary surfaces and movable parts. However, a large hurdle is the manufacture of large-area highly stretchable electrical wirings with high conductivity. Here, we describe the manufacture of printable elastic conductors comprising single-walled carbon nanotubes (SWNTs) uniformly dispersed in a fluorinated rubber. Using an ionic liquid and jet-milling, we produce long and fine SWNT bundles that can form well-developed conducting networks in the rubber. Conductivity of more than 100 S cm(-1) and stretchability of more than 100% are obtained. Making full use of this extraordinary conductivity, we constructed a rubber-like stretchable active-matrix display comprising integrated printed elastic conductors, organic transistors and organic light-emitting diodes. The display could be stretched by 30-50% and spread over a hemisphere without any mechanical or electrical damage.

20.
Adv Mater ; 32(15): e1902684, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31782576

RESUMO

Mechanically and visually imperceptible sensor sheets integrated with lightweight wireless loggers are employed in ultimate flexible hybrid electronics (FHE) to reduce vital stress/nervousness and monitor natural biosignal responses. The key technologies and applications for conceptual sensor system fabrication are reported, as exemplified by the use of a stretchable sensor sheet completely conforming to an individual's body surface to realize a low-noise wireless monitoring system (<1 µV) that can be attached to the human forehead for recording electroencephalograms. The above system can discriminate between Alzheimer's disease and the healthy state, thus offering a rapid in-home brain diagnosis possibility. Moreover, the introduction of metal nanowires to improve the transparency of the biocompatible sensor sheet allows one to wirelessly acquire electrocorticograms of nonhuman primates and simultaneously offers optogenetic stimulation such as toward-the-brain-machine interface under free movement. Also discussed are effective methods of improving electrical reliability, biocompatibility, miniaturization, etc., for metal nanowire based tracks and exploring the use of an organic amplifier as an important component to realize a flexible active probe with a high signal-to-noise ratio. Overall, ultimate FHE technologies are demonstrated to achieve efficient closed-loop systems for healthcare management, medical diagnostics, and preclinical studies in neuroscience and neuroengineering.


Assuntos
Metais/química , Monitorização Fisiológica/métodos , Nanofios/química , Tecnologia sem Fio , Animais , Encefalopatias/diagnóstico , Interfaces Cérebro-Computador , Eletroencefalografia , Humanos , Monitorização Fisiológica/instrumentação , Dispositivos Eletrônicos Vestíveis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA