RESUMO
The local lymph node assay using 5-bromo-2-deoxyuridine with flow cytometry (LLNA: BrdU-FCM) is a modified LLNA used to identify skin sensitizers. This assay measures the proliferation of auricular lymph node cells (LNCs) during the induction phase of skin sensitization and the number of BrdU-positive LNCs using flow cytometry. We determined if LLNA: BrdU-FCM can evaluate the skin sensitization potential of 20 substances, including 16 sensitizers and 4 non-sensitizers, that were tested using LLNA: DA and LLNA: BrdU-ELISA but not listed in OECD TG 429. After selecting appropriate vehicles and conducting pre-screen tests in 2 phases, solvents and test concentrations for the main test were determined. In the main study, we measured changes in LN weight, the number of LNCs, and the proportion of BrdU incorporated into LNCs to calculate stimulation indexes (SI). SI was calculated based on the total number of LNCs and BrdU incorporation in LNCs. We found that all substances were correctly classified as sensitizers or non-sensitizers. Overall, we confirmed that the LLNA: BrdU-FCM can evaluate skin sensitization potential of the 20 substances. Additionally, our results of combining 22 reference substances listed in OECD TG 429 and 20 additional substances showed that concordance of LLNA: BrdU-FCM with the LLNA was higher than before.
Assuntos
Dermatite Alérgica de Contato , Haptenos/toxicidade , Ensaio Local de Linfonodo , Animais , Bromodesoxiuridina , Feminino , Citometria de Fluxo , Camundongos Endogâmicos BALB C , Pele/efeitos dos fármacosRESUMO
The local lymph node assay using 5-bromo-2-deoxyuridine (BrdU) with flow cytometry (LLNA: BrdU-FCM) is a modified LLNA that is used to identify skin sensitizers by counting BrdU-incorporated lymph node cells (LNCs) with flow cytometry. Unlike other LLNA methods (OECD TG 429, 442A and 442B) in which the CBA/J mouse strain is used, LLNA: BrdU-FCM was originally designed to be compatible with BALB/c, a mouse strain that is more widely used in many countries. To justify the substitution of CBA/J for BALB/c, the equivalence of the test results between two strains shall be established prior to the official implementation of LLNA: BrdU-FCM. This study aims to compare the test results of LLNA: BrdU-FCM produced in BALB/c mice with those in CBA/J mice for 18 reference substances, including 13 sensitizers and 5 non-sensitizers, listed in OECD Test Guideline 429. Based on the LLNA: BrdU-FCM test procedure, we selected an appropriate solvent and then performed preliminary tests to determine the non-irritating dose ranges for the main study, which revealed the difference in the irritation responses to 8 of the 18 chemicals between the two strains. In the main study, we measured the changes in the number of total LNCs, which indicated differences in the responses to test chemicals between the two strains. However, the stimulation index obtained with the counts of BrdU-incorporated LNCs with 7-AAD using flow cytometry yielded comparable results and 100% concordance between the BALB/c and CBA/J mouse strains was achieved, suggesting that the performance of LLNA: BrdU-FCM using BALB/c mice was equivalent to that with CBA/J mice.