Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Cardiol ; 410: 132179, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38761972

RESUMO

BACKGROUND: Optimal strategies to manage embolization of transcatheter aortic valve implantation (TAVI) devices are unclear; valve-in-valve (ViV) is often used. We aimed to describe through one-single center experience its rate, causes, consequences, and management as well as the rate and relevance of commissural alignment (CA) in this context. METHODS: We identified across 1038 TAVI cases, those cases requiring ViV for the management of first device embolization. CA (absence or mild misalignment) after first and second device was assessed by CT or fluoroscopy. RESULTS: A total of 23 cases (2.2%) were identified, 52.3% embolized towards the aorta and 47.7% towards the ventricle. Suboptimal implant height (38%) and embolization at the time of post-dilation (23%) were the most frequent mechanisms together with greater rate of bicuspid valve (p < 0.001) and a trend to greater annular eccentricity. Procedural and 1-year death occurred in 13% and 34%, respectively (vs. 1.1% and 7.8% in the global cohort, p < 0.001). CA was present in 76.9% of the prostheses initially implanted but was only spontaneously achieved in 30.8% of the second ViV device. Adequate CA of both prostheses was identified in only two cases (8.7%). There were no cases of coronary obstruction. CONCLUSIONS: TAVI device embolization mechanisms can often be predicted and prevented. Mortality following bail-out ViV is higher than in regular TAVI procedures but 2/3 of these patients survived beyond 1-year follow-up. In them, valve degeneration or coronary re-access might be particularly challenging since CA was rarely achieved with both devices suggesting that greater efforts should be made in this regard.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Seguimentos , Desenho de Prótese , Embolia/etiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem
2.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39395599

RESUMO

INTRODUCTION AND OBJECTIVES: Myval technology represents the first balloon-expandable alternative since the Edwards system became commercially available. Despite certain controversies, its use has rapidly expanded. We aimed to gather all the available literature regarding its indications and outcomes. METHODS: A comprehensive search of articles published between December 2016 and May 2024 was conducted using BioMedCentral, Google Scholar, and PubMed to evaluate the main outcomes of Myval for native aortic stenosis (AS) (meta-analysis) and off-label uses (systematic review). RESULTS: A total of 151 studies were identified, and 74 were included in the analysis, covering aortic (n = 51), mitral (n = 9), tricuspid (n = 6), and pulmonary (n = 8) valve positions. A meta-analysis of studies on native AS demonstrated that Myval is safe and effective, with a 30-day mortality rate of 1.3%, good hemodynamic performance, low rates of pacemaker implantation (8.8%), and ≥ moderate paravalvular regurgitation (1.3%). Compared with other contemporary devices, Myval was competitive and associated with lower rates of pacemaker implantation. In a systematic review of off-label indications, Myval was also found to be safe and effective. In bicuspid AS, pure regurgitation, and aortic valve-in-valve procedures, success rates were 100%, 92%, and 100%, respectively, with pacemaker rates of 9.9%, 22.2%, and 3%, respectively. For mitral valve-in-valve/in-ring procedures, the success rate was 96.9%, while in tricuspid and pulmonary positions, small case series reported 100% success rates for both, with minimal procedural complications. CONCLUSIONS: Myval technology is safe and effective for the treatment of native valvular disease and dysfunctional prostheses or rings in all heart valve positions, although larger scale studies are warranted.

3.
J Clin Med ; 13(15)2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39124675

RESUMO

Background: Patients with cardiogenic shock (CS) and mitral regurgitation (MI) have a prohibitive risk that contraindicates surgical treatment. Although the feasibility of transcatheter edge-to-edge therapy (TEER) has been demonstrated in this setting, the benefit of the combined use of TEER with mechanical circulatory support devices (MCS) has not been studied. The aim of this study was to evaluate the clinical outcomes of TEER in patients with MCS. Methods: The MITRA-ASSIST study is a retrospective multicentre Spanish registry that included patients with MR and CS who underwent TEER in combination with MCS. The primary endpoint was death from any cause at 12 months. The secondary endpoint was a composite of death from any cause or hospitalisation for heart failure at 12 months. Results: A total of twenty-four patients in nine high-volume Spanish centres (66.2 (51-82) years, 70.8% female, EuroSCORE II 20.4 ± 17.8) were included. Acute ST-elevation myocardial infarction was the main CS aetiology (56%), and the most implanted MCS was the intra-aortic balloon pump (82.6%), followed by ECMO (8.7%), IMPELLACP® (4.3%), or a combination of both (4.3%). Procedural success was 95.8%, with 87.5% in-hospital survival. At 12-month follow-up, 25.0% of patients died, and 33.3% had a composite event of death from any cause or hospitalisation for heart failure. Conclusions: TEER in patients with concomitant CS and MR who require MCS appears to be a promising therapeutic alternative with a high device procedural success rate and acceptable mortality and heart failure readmission rates at follow-up.

4.
Rev Esp Cardiol (Engl Ed) ; 76(1): 19-24, 2023 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35570121

RESUMO

INTRODUCTION AND OBJECTIVES: We aimed to describe the feasibility and preliminary outcomes of commissural alignment (CA) for the balloon-expandable transcatheter heart valve. METHODS: The relationship among native commissures and transcatheter aortic valve implantation neocommissures was analyzed in 10 consecutive patients with tricuspid severe aortic stenosis undergoing transcatheter aortic valve implantation after guided implantation based on computed tomography analysis with a self-developed software. CA was predicted by in silico bio-modelling in the 10 patients and the calculated rotation was applied during crimping. Degrees of CA and coronary overlap (CO) were measured through 1-month follow up computed tomography. Transvalvular residual gradients and the rate of paravalvular leak were also analyzed. RESULTS: Mean commissural misalignment was 16.7±8°. Four patients showed mild misalignment but none of them showed a moderate or severe degree of misalignment. The in silico model accurately predicted the final in vivo position with a correlation coefficient of 0.983 (95%CI, 0.966-0.992), P <.001. Severe CO with right coronary ostium occurred in 3 patients likely due to ostial eccentricity, and CO was not present with the left coronary artery in any of the patients. Mean transaortic gradient was 6.1±3.3mmHg and there were no moderate-severe paravalvular leaks. CONCLUSIONS: Patient-specific rotation during valve crimping based on preprocedural computed tomography is feasible with balloon-expandable devices and is associated with the absence of moderate or severe commissural misalignment and left main CO.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos , Desenho de Prótese
5.
Rev Esp Cardiol (Engl Ed) ; 76(7): 503-510, 2023 Jul.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35934294

RESUMO

INTRODUCTION AND OBJECTIVES: Transthyretin cardiac amyloidosis (ATTR-CA) patients often have atrial fibrillation and increased bleeding/thrombogenic risks. We aimed to evaluate outcomes of left atrial appendage closure (LAAC) compared with patients without a known diagnosis of CA. METHODS: Comparison at long-term of patients diagnosed with ATTR-CA who underwent LAAC between 2009 and 2020 and those without a known diagnosis of CA. RESULTS: We studied a total of 1159 patients. Forty patients (3.5%) were diagnosed with ATTR-CA; these patients were older and had more comorbidities, higher HAS-BLED and CHA2DS2-VASc scores, and lower left ventricular function. Successful LAAC was achieved in 1137 patients (98.1%) with no differences between groups. Regarding in-hospital and follow-up complications, there were no differences between the groups in ischemic stroke (5% vs 2.5% in those without a known diagnosis of CA; P=.283), hemorrhagic stroke (2.5% and 0.8% in the control group; P=.284), major or minor bleeding. At the 2-year follow-up, there were no significant differences in mortality (ATTR-CA: 20% vs those without known CA: 13.6%, 0.248); however, the at 5-year follow-up, ATTR-CA patients had higher mortality (40% vs 19.2%; P <.001) but this difference was unrelated to hemorrhagic complications or ischemic stroke. CONCLUSIONS: LAAC could reduce the risk of bleeding complications and ischemic cerebrovascular events without increasing the rate of early or mid-term complications. Although long-term survival was impaired in ATTR-CA patients, it was comparable to that of patients without a known diagnosis of CA at the 2-year follow-up, suggesting that LAAC for patients with ATTR-CA might not be futile.


Assuntos
Amiloidose , Apêndice Atrial , Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Hemorragia/complicações , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Amiloidose/complicações , Amiloidose/diagnóstico , Resultado do Tratamento
6.
Rev Esp Cardiol (Engl Ed) ; 75(8): 669-680, 2022 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35067471

RESUMO

INTRODUCTION AND OBJECTIVES: ST-segment elevation myocardial infarction (STEMI) networks should guarantee STEMI care with good clinical results and within the recommended time parameters. There is no contemporary information on the performance of these networks in Spain. The objective of this study was to analyze the clinical characteristics of patients, times to reperfusion, characteristics of the intervention performed, and 30-day mortality. METHODS: Prospective, observational, multicenter registry of consecutive patients treated in 17 STEMI networks in Spain (83 centers with the Infarction Code), between April 1 and June 30, 2019. RESULTS: A total of 5401 patients were attended (mean age, 64±13 years; 76.9% male), of which 4366 (80.8%) had confirmed STEMI. Of these, 87.5% were treated with primary angioplasty, 4.4% with fibrinolysis, and 8.1% did not receive reperfusion. In patients treated with primary angioplasty, the time between symptom onset and reperfusion was 193 [135-315] minutes and the time between first medical contact and reperfusion was 107 [80-146] minutes. Overall 30-day mortality due to STEMI was 7.9%, while mortality in patients treated with primary angioplasty was 6.8%. CONCLUSIONS: Most patients with STEMI were treated with primary angioplasty. In more than half of the patients, the time from first medical contact to reperfusion was <120 minutes. Mortality at 30 days was relatively low.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Espanha/epidemiologia
7.
Int J Cardiol ; 367: 90-98, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36030132

RESUMO

BACKGROUND: Sex and prior cardiovascular disease (CVD) are known independent prognostic factors following an ST-elevation myocardial infarction (STEMI). We aimed to examine whether the association between sex and 30-day mortality differ according to the presence of previous CVD in STEMI patients. METHODS: Prospective, observational, multicentre registry of consecutive patients managed in 17 STEMI networks in Spain (83 centres), between April and June 2019. Unadjusted and adjusted logistic regression models assessed the association of 30-day mortality with sex and prior CVD status, as well as their interaction. RESULTS: Among 4366 patients (mean age 63.7 ± 13.0 years; 78% male), there were 337 (8.1%) deaths within the first 30 days. There was an association between crude 30-day mortality and sex (women 10.4% vs. men 7.4%, p = 0.003), and prior CVD (CVD 13.7% vs non-CVD 6.8%, p < 0.001). After adjustment for potential confounding, neither sex nor prior CVD were apparently associated with mortality. Nevertheless, we found a significant sex-CVD interaction (p-interaction = 0.006), since women were at lower risk than men in the subset of patients with prior CVD (OR = 0.30, 95%CI = 0.12-0.80) but not in those without CVD (OR = 1.17, 95%CI = 0.79-1.74). CONCLUSIONS: Women as well as patients with prior CVD have an increased crude risk of 30-day mortality. However, sex-related differences in short term mortality are modulated by the interaction with CVD in STEMI patients. Compared to men, women had a similar prognosis in the subset of patients without CVD, whereas they were associated with a lower risk of mortality among those with prior CVD after adjusting for other prognostic factors.


Assuntos
Doenças Cardiovasculares , Infarto do Miocárdio com Supradesnível do Segmento ST , Idoso , Doenças Cardiovasculares/diagnóstico , Estudos de Coortes , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Fatores Sexuais
8.
Rev Esp Cardiol (Engl Ed) ; 75(3): 203-212, 2022 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33781722

RESUMO

INTRODUCTION AND OBJECTIVES: Final position of the neo-commissures is uncontrolled during transcatheter aortic valve implantation (TAVI), potentially hindering coronary access and future procedures. We aimed to develop a standard method to achieve commissural alignment with the ACURATE neo valve. METHODS: The relationship between native and TAVI neo-commissures was analyzed in 11 severe aortic stenosis patients undergoing TAVI. Based on computed tomography analysis, an in silico model was developed to predict final TAVI commissural posts position. A modified implantation technique, accurate commissural alignment (ACA) and a dedicated delivery system were developed. TAVI implants were tested in 3-dimensional (3D) printed models and in vivo. Commissural misalignment and coronary overlap (CO) were analyzed. RESULTS: The in silico model accurately predicted final position of commissural posts irrespective of the implantation technique performed (correlation coefficient, 0.994; 95%CI, 0.989-0.998; P<.001). TAVI implant with patient-specific rotation was simulated in 3D printed models and in 9 patients. ACA-oriented TAVI implants presented adequate commissural alignment in vivo (mean commissural misalignment of 7.7 ±3.9°). None of the ACA oriented implants showed CO, whereas in silico conventional implants predicted CO in 6 of the 9 cases. CONCLUSIONS: Accurate commissural alignment of the ACURATE neo device is feasible by inserting the delivery system with a patient-specific rotation based on computed tomography analysis. This is a simple and reproducible method for commissural alignment that can be potentially used for all kinds of TAVI devices.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
9.
Rev Esp Cardiol (Engl Ed) ; 75(10): 805-815, 2022 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35688688

RESUMO

INTRODUCTION AND OBJECTIVES: Equal opportunities to access technical advances with recognized clinical value should be a priority of the publicly-funded health system. We analyzed variability among all the Spanish autonomous communities in the use of cardiovascular techniques with an established indication and its relationship with economic indicators, burden of disease, and hospital mortality. METHODS: The activity registries of various Associations of the Spanish Society of Cardiology from 2011 to 2019 were analyzed for coronary angiography, overall percutaneous coronary intervention (PCI), primary PCI, implantable cardioverter-defibrillators (ICD), cardiac resynchronization therapy, and transcatheter aortic valve replacement (TAVR). Economic indices (gross domestic product and per capita health care expenditure) were obtained from public sources and data on attendance rates and mortality from the Resources and Quality in Cardiology (RECALCAR) reports of the Spanish Society of Cardiology. We analyzed the coefficient of variation for activity and the correlation of activity with regional economic indices, attendance rates, and risk-adjusted rates of in-hospital mortality. RESULTS: We identified wide variability in the use of technologies, especially for primary PCI (18%), ICD (22%), cardiac resynchronization therapy (36%), and TAVR (42%). A certain correlation with attendance rates was seen only for overall PCI and ICD. In general, no significant correlation was found between the use of the techniques and the economic indices of wealth and expenditure. The correlation with in-hospital mortality showed no significant results, although this was the analysis with the greatest limitations because the impact of these techniques on survival is exerted more in the mid- and long-term. CONCLUSIONS: The results of this study, despite its inherent limitations, show marked variability between autonomous communities in the use of cardiovascular technologies, which is not explained by economic differences or by hospital attendance rates due to the corresponding diseases.


Assuntos
Cardiologia , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Angiografia Coronária , Mortalidade Hospitalar , Humanos , Sistema de Registros , Resultado do Tratamento
10.
Int J Cardiol ; 351: 25-31, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-34979152

RESUMO

BACKGROUND: Several studies have compared surface electrocardiographic changes following different self-expandable (SE) (Evolut (Medtronic, USA); Acurate (Boston Scientific, USA); Portico (Abbott, USA); and Allegra (NVT, Germany)) and balloon-expandable (BE) Sapien-3 (Edwards Lifesciences, USA) transcatheter heart valves. We aimed to compare these prosthesis with the novel Myval BE prosthesis (Meril Life, India). METHODS: Academic European registry of consecutive patients with severe aortic stenosis who received any of the 6 aforementioned valves. Baseline, post-procedural, and discharge 12­leads electrocardiograms (ECG) were centrally analyzed and compared. RESULTS: A total of 1131 patients were included: 135 Myval (11.9%), 290 Sapien-3 (25.6%), 298 Evolut (26.3%), 180 Acurate (15.9%), 125 Portico (11.1%), and 103 Allegra (9.1%). There were no baseline differences in intraventricular conduction disturbances rate. Compared to the novel BE Myval, there were similar procedural and in-hospital outcomes. Similar rates of early new permanent pacemaker implant (PPI) were observed amongst Myval (7.4%), Sapien-3 (13.4%), and Acurate (9.1%), but Evolut, Portico, and Allegra presented significantly higher rates (18.5%, p = 0.003; 29.5% p < 0.001 and 22%, p = 0.001, respectively). Central analysis of ECGs, unraveled significant prolongation of the PR segment with Evolut, Portico and Allegra whereas Evolut, Acurate, and Portico showed significant QRS widening compared to Myval. However, at discharge no differences in PR segment duration were observed while, Evolut, and Portico- but not Acurate, Allegra or Sapien-3 - still presented significant widening of QRS segment compared to Myval. CONCLUSIONS: After blinded central ECG analysis, the novel Myval balloon-expandable prosthesis was associated with a low rate of early conduction disturbances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
11.
JACC Cardiovasc Interv ; 15(13): 1366-1377, 2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35583363

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) is frequently associated with significant morbidity and mortality; such patients are often deemed to be at high surgical risk. Heterotopic bicaval stenting is an emerging, attractive transcatheter solution for these patients. OBJECTIVES: The aim of this study was to evaluate the 30-day safety and 6-month efficacy outcomes of specifically designed bioprosthetic valves for the superior and inferior vena cava. METHODS: TRICUS EURO (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) is a nonblinded, nonrandomized, single-arm, multicenter, prospective trial that enrolled patients from 12 European centers between December 2019 and February 2021. High-risk individuals with severe symptomatic TR despite optimal medical therapy were included. The primary endpoint was quality-of-life (QOL) improvement measured by Kansas City Cardiomyopathy Questionnaire score and New York Heart Association (NYHA) functional class improvement at 6-month follow-up. RESULTS: Thirty-five patients (mean age 76 ± 6.8 years, 83% women) were treated using the TricValve system. All patients at baseline were in NYHA functional class III or IV. At 30 days, procedural success was 94%, with no procedural deaths or conversions to surgery. A significant increase in QOL at 6 months follow-up was observed (baseline and 6-month Kansas City Cardiomyopathy Questionnaire scores 42.01 ± 22.3 and 59.7 ± 23.6, respectively; P = 0.004), correlating with a significant improvement in NYHA functional class, with 79.4% of patients noted to be in functional class I or II at 6 months (P = 0.0006). The rates of 6-month all-cause mortality and heart failure hospitalization were 8.5% and 20%, respectively. CONCLUSIONS: The dedicated bicaval system for treating severe symptomatic TR was associated with a high procedural success rate and significant improvements in both QOL and functional classification at 6 months follow-up.


Assuntos
Cardiomiopatias , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
12.
Rev Esp Cardiol (Engl Ed) ; 75(12): 1001-1010, 2022 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35272968

RESUMO

INTRODUCTION AND OBJECTIVES: Transcatheter edge-to-edge repair (TEER) should be considered in patients with heart failure and secondary mitral regurgitation (MR). Angiotensin receptor-neprilysin inhibitors (ARNIs) have been demonstrated to improve prognosis in heart failure. We aimed to evaluate the impact ARNIs on patient selection and outcomes. METHODS: The population of the Spanish TEER prospective registry (March 2012 to January 2021) was divided into 2 groups: a) TEER before the ARNI era (n=450) and b) TEER after the recommendation of ARNIs by European Guidelines (n=639), with further analysis according to intake (n=52) or not (n=587) of ARNIs. RESULTS: A total of 1089 consecutive patients underwent TEER for secondary MR. In the ARNI era, there was a reduction in left ventricle dilation (82mL vs 100mL, P=.025), and better function (35% vs 38%, P=.011). At 2 years of follow-up, mortality (10.6% vs 17.3%, P <.001) and heart failure readmissions (16.6% vs 27.8%, P <.001) were lower in the ARNI era, but not recurrent MR. In the ARNI era, 1- and 2-year mortality were similar irrespective of ARNI intake but patients on ARNIs had a lower risk of readmission+mortality at 2 years (OR, 0.369; 95%CI, 0.137-0.992; P=.048), better NYHA class, and lower recurrence of MR III-IV (1.9% vs 14.3%, P=.011). CONCLUSIONS: Better patient selection for TEER has been achieved in the last few years with a parallel improvement in outcomes. The use of ARNIs was associated with a significant reduction in overall events, better NYHA class, and lower MR recurrence.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Neprilisina , Humanos , Insuficiência Cardíaca/tratamento farmacológico , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/tratamento farmacológico , Insuficiência da Valva Mitral/cirurgia , Neprilisina/antagonistas & inibidores , Receptores de Angiotensina , Resultado do Tratamento
13.
EuroIntervention ; 16(17): 1426-1433, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33164893

RESUMO

AIMS: The aim of this study was to assess clinical and prognosis differences in patients with COVID-19 and STEMI. METHODS AND RESULTS: Using a nationwide registry of consecutive patients managed within 42 specific STEMI care networks, we compared patient and procedure characteristics and in-hospital outcomes in two different cohorts, according to whether or not they had COVID-19. Among 1,010 consecutive STEMI patients, 91 were identified as having COVID-19 (9.0%). With the exception of smoking status (more frequent in non-COVID-19 patients) and previous coronary artery disease (more frequent in COVID-19 patients), clinical characteristics were similar between the groups, but COVID-19 patients had more heart failure on arrival (31.9% vs 18.4%, p=0.002). Mechanical thrombectomy (44% vs 33.5%, p=0.046) and GP IIb/IIIa inhibitor administration (20.9% vs 11.2%, p=0.007) were more frequent in COVID-19 patients, who had an increased in-hospital mortality (23.1% vs 5.7%, p<0.0001), that remained consistent after adjustment for age, sex, Killip class and ischaemic time (OR 4.85, 95% CI: 2.04-11.51; p<0.001). COVID-19 patients had an increase of stent thrombosis (3.3% vs 0.8%, p=0.020) and cardiogenic shock development after PCI (9.9% vs 3.8%, p=0.007). CONCLUSIONS: Our study revealed a significant increase in in-hospital mortality, stent thrombosis and cardiogenic shock development after PCI in patients with STEMI and COVID-19 in comparison with contemporaneous non-COVID-19 STEMI patients.


Assuntos
COVID-19 , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Mortalidade Hospitalar , Hospitais , Humanos , Intervenção Coronária Percutânea/efeitos adversos , SARS-CoV-2 , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Resultado do Tratamento
14.
Rev Esp Cardiol (Engl Ed) ; 74(12): 1032-1041, 2021 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33158760

RESUMO

INTRODUCTION AND OBJECTIVES: Aortic self-expandable (SE) transcatheter aortic valve implantation (TAVI) devices are particularly useful for patients with aortic stenosis and small/tortuous vessels, small aortic annuli, or low coronary ostia. However, it is unclear whether the growing range of SE devices shows comparable hemodynamic and clinical outcomes. We aimed to determine the differential hemodynamic (residual valve area and regurgitation) and clinical outcomes of these devices in comparable scenarios. METHODS: All patients were enrolled from 4 institutions and were managed with 4 different SE TAVI devices. Baseline and follow-up clinical data were collected and echocardiographic tests blindly and centrally analyzed. Patients were compared according to valve type and a 1:1 matched comparison was performed according to degree of calcification, aortic annulus dimensions, left ventricular ejection fraction, and body surface area. RESULTS: In total, 514 patients were included (Evolut R/PRO, 217; ACURATE neo, 107; ALLEGRA, 102; Portico, 88). Surgical risk scores were comparable in the unmatched population. No differences were observed in the post-TAVI regurgitation rate and in in-hospital mortality (2.7%). The rate of pacemaker implantation at discharge was significantly different among devices (P=.049), with Portico showing the highest rate (23%) and ACURATE neo the lowest (9.5%); Evolut R/PRO and ALLEGRA had rates of 15.9% and 21.2%, respectively. The adjusted comparison showed worse residual TAVI gradients and aortic valve area with ACURATE neo vs ALLEGRA (P=.001) but the latter had higher risk of valve embolization and a tendency for more cerebrovascular events. CONCLUSIONS: A matched comparison of 4 SE TAVI devices showed no differences regarding residual aortic regurgitation and in-hospital mortality.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
15.
J Clin Med ; 10(4)2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33673247

RESUMO

BACKGROUND AND AIM: Recent randomized data comparing percutaneous mitral valve repair (PMVR) versus optimal medical treatment in patients with functional MR (FMR) seemed to highlight the importance of the learning curve not only for procedural outcomes but also for patient selection. The aim of the study was to compare a contemporary series of patients undergoing PMVR using a second-generation Mitraclip device (Mitraclip NT) with previous cohorts treated with a first-generation system. METHODS: This multicenter study collected individual data from 18 centers between 2012 and 2017. The cohort was divided into three groups according to the use of the first-generation Mitraclip during the first (control-1) or second half (control-2) or the Mitraclip NT system. RESULTS: A total of 545 consecutive patients were included in the study. Among all, 182 (33.3%), 183 (33.3%), and 180 (33.3%) patients underwent mitral repair in the control-1, control-2, and NT cohorts, respectively. Procedural success was achieved in 93.3% of patients without differences between groups. Major adverse events did not statistically differ among groups, but there was a higher rate of pericardial effusion in the control-1 group (4.3%, 0.6%, and 2.6%, respectively; p = 0.025). The composite endpoint of death, surgery, and admission for congestive heart failure (CHF) at 12 months was lower in the NT group (23.5% in control-1, 22.5% in control-2, and 8.3% in the NT group; p = 0.032). CONCLUSIONS: The present paper shows that contemporary clinical outcomes of patients undergoing PMVR with the Mitraclip system have improved over time.

16.
Int J Cardiol ; 345: 29-35, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34610357

RESUMO

BACKGROUND: Isolated atrial fibrillation can cause mitral regurgitation (MR) in patients with normal left ventricular systolic function and no organic disease of the mitral valve. Little information is available regarding outcomes of Mitraclip in patients with atrial functional mitral regurgitation (AFMR). We aimed to evaluate 12-month clinical and echocardiographic outcomes of transcatheter mitral valve repair (TMVR) with MitraClip in patients with AFMR compared to those with ventricular functional or degenerative/mixed MR. METHODS: Registry-based analysis of all consecutive patients who underwent TMVR and were included in the Spanish Registry of Mitraclip. Changes in MR and NYHA functional class, and a combined endpoint including all-cause mortality and hospitalizations due to heart failure were the main outcomes. RESULTS: Overall, 1074 (69.1% male, 73.3 ± 10.2 years-old) patients were analyzed in this report. 48 patients (4.5%) presented AFMR. AFMR was significantly reduced after TMVR, with a procedural success rate of 91.7%, and this reduction persisted at 12-month (p < 0.001). Patients with AFMR showed a significant functional improvement at 6- and 12-month follow-up in our series (baseline: NYHA III 70.8% IV 18.8% vs. 1-year: NYHA III 21.7% IV 0%; p < 0.001). The probability of survival free of readmission for heart failure and all-cause mortality within the first year after TMVR was 74.9%. Procedural and clinical outcomes, as well as recurrent rates of MR were similar acutely and at 1-year compared to other etiologies. CONCLUSION: TMVR in patients with AFMR showed no significant differences compared to ventricular functional or degenerative/mixed MR regarding MR reduction or clinical outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Ecocardiografia , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
17.
Cardiol J ; 27(5): 524-532, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32329042

RESUMO

BACKGROUND: Atrial septal defect (ASD) is one of the most common congenital heart diseases. Percutaneous closure is the preferred treatment, but certain complications remain a concern. The most common devices are AMPLATZER™ (ASO) (St. Jude Medical, St. Paul, MN, USA) and Figulla Flex® septal occluders (FSO) (Occlutech GmbH, Jena, Germany). The present study aimed to assess main differences in outcomes. METHODS: A systematic search in Pubmed and Google scholarship was performed by two independent reviewers for any study comparing ASO and FSO. Searched terms were "Figulla", "Amplatzer", and "atrial septal defect". A random-effects model was used. RESULTS: A total of 11 studies including 1770 patients (897 ASO; 873 FSO) were gathered. Baseline clinical and echocardiographic characteristics were comparable although septal aneurysm was more often reported in patients treated with ASO (32% vs. 25%; p = 0.061). Success rate (94% vs. 95%; OR: 0.81; 95% CI: 0.38-1.71; p = 0.58) and peri-procedural complications were comparable. Procedures were shorter, requiring less fluoroscopy time with an FSO device (OR: 0.59; 95% CI: 0.20-0.97; p = 0.003). Although the global rate of complications in long-term was similar, the ASO device was associated with a higher rate of supraventricular arrhythmias (14.7% vs. 7.8%, p = 0.009). CONCLUSIONS: Percutaneous closure of ASD is a safe and effective, irrespective of the type of device. No differences exist regarding procedural success between the ASO and FSO devices but the last was associated to shorter procedure time, less radiation, and lower rate of supraventricular arrhythmias in follow-up. Late cardiac perforation did not occur and death in the follow-up was exceptional.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Cateterismo Cardíaco , Ecocardiografia , Alemanha , Humanos , Resultado do Tratamento
18.
Rev Esp Cardiol (Engl Ed) ; 73(8): 615-622, 2020 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31561981

RESUMO

INTRODUCTION AND OBJECTIVES: Renal denervation is a percutaneous intervention for the treatment of resistant hypertension. Randomized studies have shown contradictory results on its efficacy. We present the results of a renal denervation registry for the treatment of resistant hypertension in real-life patients in Spain. METHODS: Multicenter registry of consecutive patients with resistant hypertension treated with renal denervation in Spain between 2009 and 2018. RESULTS: We included 125 patients (mean age, 56 years; 41% female; mean onset of hypertension 14±9 years previously). Office systolic and diastolic blood pressure and ambulatory blood pressure monitoring decreased 6 months after the intervention (166±20/95±16 to 149±22/87±16 mmHg and 151±14/89±12 to 143±15/84±11, both P <.0001). At 12 months, the blood pressure reduction was maintained and the number of antihypertensive drugs decreased from 4.9±1.2 to 4.4±1.5 (P=.0001). There were no significant procedure-related complications. The response rate to denervation at 1 year was 80%, but there were wide differences between centers. CONCLUSIONS: In patients with resistant hypertension, treatment with renal denervation was related to a decrease in office blood pressure and, more importantly, in ambulatory blood pressure monitoring, with a significant reduction in pharmacological treatment.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea , Denervação , Feminino , Humanos , Hipertensão/tratamento farmacológico , Rim/cirurgia , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Espanha/epidemiologia , Simpatectomia , Resultado do Tratamento
19.
Ann Transl Med ; 8(15): 956, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32953756

RESUMO

BACKGROUND: Limited information has been reported regarding the impact of percutaneous mitral valve repair (PMVR) on ventricular arrhythmic (VA) burden. The aim of this study was to address the incidence of VA and appropriate antitachycardia implantable cardiac defibrillator (ICD) therapies before and after PMVR. METHODS: We retrospectively analyzed all consecutive patients with heart failure with reduce left ventricular ejection fraction (LVEF), functional mitral regurgitation (FMR) grade 3+ or 4+ and an active ICD or cardiac resynchronizer who underwent PMVR in any of the eleven recruiting centers. Only patients with complete available device VA monitoring from one-year before to one year after PMVR were included. Baseline clinical and echocardiographic characteristics were collected before PMVR and at 12-months follow-up. RESULTS: Ninety-three patients (68.2±10.9 years old, male 88.2%) were enrolled. PMVR was successfully performed in all patients and device success at discharge was 91.4%. At 12-month follow-up, we observed a significant reduction in mitral regurgitation severity, NT-proBNP and prevalence of severe pulmonary hypertension and severe kidney disease. Patients also referred a significant improvement in NYHA functional class and showed a non-significant trend to reserve left ventricular remodeling. After PMVR a significant decrease in the incidence of non-sustained ventricular tachycardia (VT) (5.0±17.8 vs. 2.7±13.5, P=0.002), sustained VT or ventricular fibrillation (0.9±2.5 vs. 0.5±2.9, P=0.012) and ICD antitachycardia therapies (2.5±12.0 vs. 0.9±5.0, P=0.033) were observed. CONCLUSIONS: PMVR was related to a reduction in arrhythmic burden and ICD therapies in our cohort.

20.
J Am Coll Cardiol ; 76(21): 2463-2473, 2020 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-33213725

RESUMO

BACKGROUND: In catheter-based procedures, acute kidney injury (AKI) is a frequent, serious complication ranging from 10% to 30%. In MitraClip (Abbott Vascular, Santa Clara, California), a usually contrast-free procedure, there is scarce data about its real incidence and impact. OBJECTIVES: This study aimed to evaluate incidence, predictive factors, and midterm outcomes of AKI in patients with significant mitral regurgitation (MR) undergoing transcatheter valve repair with MitraClip. METHODS: A total of 721 patients undergoing MitraClip were included. AKI was defined as an absolute or a relative increase in serum creatinine of >0.3 mg/dl or ≥50%, respectively, or the need for hemodialysis during index hospitalization. RESULTS: The mean age of the patients was 72 ± 11 years (28.3% women). Median estimated glomerular filtration rate (eGFR) was 43.7 ml/min/1.73 m2 (interquartile range: 30.9 to 60.1 ml/min/1.73 m2), and was <60 ml/min/1.73 m2 in 74.9% of the patients. AKI after MitraClip occurred in 106 patients (14.7%). Baseline hemoglobin (<11 g/dl) (odds ratio [OR]: 1.97; p = 0.003), urgent procedure (OR: 3.44; p = 0.003), and absence of device success (OR: 3.37; p < 0.001) were independent predictors of AKI. Patients with AKI had worse outcomes compared to those without AKI, including a higher proportion of in-hospital bleeding events (3.8% vs. 0.8%; p = 0.011), 2-year all-cause mortality (40.5% vs. 18.7%; p <0.001), and major adverse cardiac events (63.6% vs. 23.5%; p <0.001). Combination of AKI with significant residual MR after the procedure conferred even worst outcomes (2-year all-cause mortality 50.0% vs. 19.6%; p = 0.001, and major adverse cardiac events 70.0% vs. 18.9%; p < 0.001). CONCLUSIONS: Despite being a "zero-contrast" procedure, one-sixth of patients undergoing transcatheter mitral valve repair had AKI, linked to device failure or other severe conditions. The occurrence of AKI was associated with worse outcomes, highlighting the importance to detect and reduce this complication in high-risk population.


Assuntos
Injúria Renal Aguda/mortalidade , Anuloplastia da Valva Mitral/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/mortalidade , Injúria Renal Aguda/etiologia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/instrumentação , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Espanha/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA