Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Card Surg ; 35(11): 3235-3238, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32970354

RESUMO

Outflow graft complications after left ventricular assist device placement are infrequent but highly morbid. In this case report, we describe endovascular repair of multiple outflow graft defects with external hemorrhage in a complex patient using overlapping stent grafts. This approach successfully stopped the outflow graft hemorrhage and temporized the patient for subsequent cardiac transplantation.


Assuntos
Procedimentos Endovasculares/métodos , Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Hemorragia/cirurgia , Complicações Pós-Operatórias/cirurgia , Disfunção Ventricular/cirurgia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Resultado do Tratamento
2.
Cardiol Young ; 28(11): 1316-1322, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30220265

RESUMO

BACKGROUND: We reviewed all patients who were supported with extracorporeal membrane oxygenation and/or ventricular assist device at our institution in order to describe diagnostic characteristics and assess mortality. METHODS: A retrospective cohort study was performed including all patients supported with extracorporeal membrane oxygenation and/or ventricular assist device from our first case (8 October, 1998) through 25 July, 2016. The primary outcome of interest was mortality, which was modelled by the Kaplan-Meier method. RESULTS: A total of 223 patients underwent 241 extracorporeal membrane oxygenation runs. Median support time was 4.0 days, ranging from 0.04 to 55.8 days, with a mean of 6.4±7.0 days. Mean (±SD) age at initiation was 727.4 days (±146.9 days). Indications for extracorporeal membrane oxygenation were stratified by primary indication: cardiac extracorporeal membrane oxygenation (n=175; 72.6%) or respiratory extracorporeal membrane oxygenation (n=66; 27.4%). The most frequent diagnosis for cardiac extracorporeal membrane oxygenation patients was hypoplastic left heart syndrome or hypoplastic left heart syndrome-related malformation (n=55 patients with HLHS who underwent 64 extracorporeal membrane oxygenation runs). For respiratory extracorporeal membrane oxygenation, the most frequent diagnosis was congenital diaphragmatic hernia (n=22). A total of 24 patients underwent 26 ventricular assist device runs. Median support time was 7 days, ranging from 0 to 75 days, with a mean of 15.3±18.8 days. Mean age at initiation of ventricular assist device was 2530.8±660.2 days (6.93±1.81 years). Cardiomyopathy/myocarditis was the most frequent indication for ventricular assist device placement (n=14; 53.8%). Survival to discharge was 42.2% for extracorporeal membrane oxygenation patients and 54.2% for ventricular assist device patients. Kaplan-Meier 1-year survival was as follows: all patients, 41.0%; extracorporeal membrane oxygenation patients, 41.0%; and ventricular assist device patients, 43.2%. Kaplan-Meier 5-year survival was as follows: all patients, 39.7%; extracorporeal membrane oxygenation patients, 39.7%; and ventricular assist device patients, 43.2%. CONCLUSIONS: This single-institutional 18-year review documents the differential probability of survival for various sub-groups of patients who require support with extracorporeal membrane oxygenation or ventricular assist device. The indication for mechanical circulatory support, underlying diagnosis, age, and setting in which cannulation occurs may affect survival after extracorporeal membrane oxygenation and ventricular assist device. The Kaplan-Meier analyses in this study demonstrate that patients who survive to hospital discharge have an excellent chance of longer-term survival.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Previsões , Cardiopatias Congênitas/cirurgia , Coração Auxiliar , Feminino , Seguimentos , Cardiopatias Congênitas/mortalidade , Humanos , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Reino Unido/epidemiologia
3.
Ann Thorac Surg ; 106(1): e15-e17, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29530775

RESUMO

Utilization of a left ventricular assist device as a bridge to myocardial recovery is an established therapy for acute systolic heart failure. However, device removal can present a technical challenge, with no clear consensus on preferred method. In this case report, we describe a complex patient who underwent successful explantation of a left ventricular assist device using an intraoperatively constructed apical plug. This method utilizes inexpensive and easily accessible materials, minimizes ventricular distortion during device removal, and preserves the ventricular sewing ring for future reimplantation.


Assuntos
Remoção de Dispositivo/métodos , Insuficiência Cardíaca Sistólica/cirurgia , Coração Auxiliar , Ajuste de Prótese/métodos , Adulto , Bioprótese , Hemorragia Cerebral/etiologia , Hemorragia Cerebral/cirurgia , Craniectomia Descompressiva , Empiema Pleural/etiologia , Empiema Pleural/terapia , Insuficiência Cardíaca Sistólica/etiologia , Humanos , Abscesso Pulmonar/etiologia , Abscesso Pulmonar/cirurgia , Masculino , Miocardite/complicações , Politetrafluoretileno , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Volume Sistólico , Técnicas de Sutura , Toracotomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA